977 resultados para electroosmotic pump


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thesis (Master's)--University of Washington, 2016-06

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thesis (Ph.D.)--University of Washington, 2016-05

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Current evidence supports parenteral infusion of proton pump inhibitors (PPI) after endoscopic treatment of bleeding peptic ulcers and such treatment seems reasonable where there is active bleeding or visible vessel on endoscopy. Parenteral boluses of PPI can be used in patients nil by mouth who cannot tolerate oral therapy. We sought to examine the appropriateness of parenteral PPI use. Drug utilisation evaluation was performed on 94 patients admitted to a 500 bed metropolitan hospital. 39 patients received continuous parenteral infusion of omeprazole (8 mg/ h) over a mean of 60 ± 29 h. 55 patients had parenteral boluses (40 mg bd) of omeprazole over a mean of 5 ± 4 days. Indications for PPI infusion (n = 39) were: major haemorrhage requiring transfusion (23), minor haemorrhage (8), dyspepsia (4) and others (4). 31 of the 39 patients on PPI infusion had upper gastrointestinal (GI) endoscopy. PPI infusion was commenced prior to endoscopy in 26 (84%) patients. 13 patients (33%) had active bleeding or visible non bleeding vessels at endoscopy. Only 11 patients (28%) had endoscopically treated peptic ulcers. Indications for parenteral PPI boluses (n = 55) included patients nil by mouth unable to take maintenance PPI orally (21), minor haemorrhage (8), peptic ulcer prophylaxis in seriously unwell (6), major haemorrhage (4), dyspepsia (2), postoprative period following peptic ulcer surgery (2) and others (12). Endoscopy was performed in 10 patients (18%) with only 1 endoscopically treated peptic ulcer. Our data suggest significant inappropriate use of parenteral PPI, which may be used for minor GI bleeding and dyspepsia and are typically commenced prior to endoscopy. These findings can explain the costly hospital expenditure on PPI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Performance optimisation of ultra-long Raman laser links is studied theoretically and experimentally. We observe that it is possible to reduce signal power excursion by adjusting FBG reflectivity without compromising pump efficiency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of the work described here has been to seek methods of narrowing the present gap between currently realised heat pump performance and the theoretical limit. The single most important pre-requisite to this objective is the identification and quantitative assessment of the various non-idealities and degradative phenomena responsible for the present shortfall. The use of availability analysis has been introduced as a diagnostic tool, and applied to a few very simple, highly idealised Rankine cycle optimisation problems. From this work, it has been demonstrated that the scope for improvement through optimisation is small in comparison with the extensive potential for improvement by reducing the compressor's losses. A fully instrumented heat pump was assembled and extensively tested. This furnished performance data, and led to an improved understanding of the systems behaviour. From a very simple analysis of the resulting compressor performance data, confirmation of the compressor's low efficiency was obtained. In addition, in order to obtain experimental data concerning specific details of the heat pump's operation, several novel experiments were performed. The experimental work was concluded with a set of tests which attempted to obtain definitive performance data for a small set of discrete operating conditions. These tests included an investigation of the effect of two compressor modifications. The resulting performance data was analysed by a sophisticated calculation which used that measurements to quantify each dagradative phenomenon occurring in that compressor, and so indicate where the greatest potential for improvement lies. Finally, in the light of everything that was learnt, specific technical suggestions have been made, to reduce the losses associated with both the refrigerant circuit and the compressor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this investigation was to design a novel magnetic drive and bearing system for a new centrifugal rotary blood pump (CRBP). The drive system consists of two components: (i) permanent magnets within the impeller of the CRBP; and (ii) the driving electromagnets. Orientation of the magnets varies from axial through to 60° included out-lean (conical configuration). Permanent magnets replace the electromagnet drive to allow easier characterization. The performance characteristics tested were the axial force of attraction between the stator and rotor at angles of rotational alignment, Ø, and the corresponding torque at those angles. The drive components were tested for various magnetic cone angles, ?. The test was repeated for three backing conditions: (i) non-backed; (ii) steel-cupped; and (iii) steel plate back-iron, performed on an Instron tensile testing machine. Experimental results were expanded upon through finite element and boundary element analysis (BEM). The force/torque characteristics were maximal for a 12-magnet configuration at 0° cone angle with steel-back iron (axial force = 60 N, torque = 0.375 Nm). BEM showed how introducing a cone angle increases the radial restoring force threefold while not compromising axial bearing force. Magnets in the drive system may be orientated not only to provide adequate coupling to drive the CRBP, but to provide significant axial and radial bearing forces capable of withstanding over 100 m/s2 shock excitation on the impeller. Although the 12 magnet 0° (?) configuration yielded the greatest force/torque characteristic, this was seen as potentially unattractive as this magnetic cone angle yielded poor radial restoring force characteristics.