936 resultados para divergence angle


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Literature dealing with the history of Chinese printed books and printing is voluminous. Yet studies of how knowledge in general and utilitarian forms of knowledge in particular were generated, accumulated and circulated by printed books and their relationship with the long-term socio-economic transformation of China are rare. This paper aims to open up the subject by examining the long-term trends in the production of manuscripts and books and focusing on the connections between the generation and dissemination of useful knowledge in China and the production and circulation of printed books over the centuries and dynasties from circa 581 to 1840 compared to Europe. It connects trends in this indicator for knowledge formation and diffusion to economic growth, urbanization, changes in higher forms of education, the rise of literacy, the development of printing technologies, and changes in perceptions of the natural world. It concludes that human capital formation in China probably proceeded at a slower rate,which is relevant for narratives of the “divergence” between China and Europe.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Phylogenetic analysis of the sequence of the H gene of 75 measles virus (MV) strains (32 published and 43 new sequences) was carried out. The lineage groups described from comparison of the nucleotide sequences encoding the C-terminal regions of the N protein of MV were the same as those derived from the H gene sequences in almost all cases. The databases document a number of distinct genotype switches that have occurred in Madrid (Spain). Well-documented is the complete replacement of lineage group C2, the common European genotype at that time, with that of group D3 around the autumn of 1993. No further isolations of group C2 took place in Madrid after this time. The rate of mutation of the H gene sequences of MV genotype D3 circulating in Madrid from 1993 to 1996 was very low (5 x 10(-4) per annum for a given nucleotide position). This is an order of magnitude lower than the rates of mutation observed in the HN genes of human influenza A viruses. The ratio of expressed over silent mutations indicated that the divergence was not driven by immune selection in this gene. Variations in amino acid 117 of the H protein (F or L) may be related to the ability of some strains to haemagglutinate only in the presence of salt. Adaptation of MV to different primate cell types was associated with very small numbers of mutations in the H gene. The changes could not be predicted when virus previously grown in human B cell lines was adapted to monkey Vero cells. In contrast, rodent brain-adapted viruses displayed a lot of amino acid sequence variation from normal MV strains. There was no convincing evidence for recombination between MV genotypes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To assess the comparative accuracy of potential screening tests for open angle glaucoma (OAG).

METHODS: Medline, Embase, Biosis (to November 2005), Science Citation Index (to December 2005), and The Cochrane Library (Issue 4, 2005) were searched. Studies assessing candidate screening tests for detecting OAG in persons older than 40 years that reported true and false positives and negatives were included. Meta-analysis was undertaken using the hierarchical summary receiver operating characteristic model.

RESULTS: Forty studies enrolling over 48,000 people reported nine tests. Most tests were reported by only a few studies. Frequency-doubling technology (FDT; C-20-1) was significantly more sensitive than ophthalmoscopy (30, 95% credible interval [CrI] 0-62) and Goldmann applanation tonometry (GAT; 45, 95% CrI 17-68), whereas threshold standard automated perimetry (SAP) and Heidelberg Retinal Tomograph (HRT II) were both more sensitive than GAT (41, 95% CrI 14-64 and 39, 95% CrI 3-64, respectively). GAT was more specific than both FDT C-20-5 (19, 95% CrI 0-53) and threshold SAP (14, 95% CrI 1-37). Judging performance by diagnostic odds ratio, FDT, oculokinetic perimetry, and HRT II are promising tests. Ophthalmoscopy, SAP, retinal photography, and GAT had relatively poor performance as single tests. These findings are based on heterogeneous data of limited quality and as such are associated with considerable uncertainty.

CONCLUSIONS: No test or group of tests was clearly superior for glaucoma screening. Further research is needed to evaluate the comparative accuracy of the most promising tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Open angle glaucoma (OAG) is a common cause of blindness.

OBJECTIVES: To assess the effects of medication compared with initial surgery in adults with OAG.

SEARCH METHODS: We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2012, Issue 7), Ovid MEDLINE, Ovid MEDLINE In-Process and Other Non-Indexed Citations, Ovid MEDLINE Daily, Ovid OLDMEDLINE (January 1946 to August 2012), EMBASE (January 1980 to August 2012), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to August 2012), Biosciences Information Service (BIOSIS) (January 1969 to August 2012), Cumulative Index to Nursing and Allied Health Literature (CINAHL) (January 1937 to August 2012), OpenGrey (System for Information on Grey Literature in Europe) (www.opengrey.eu/), Zetoc, the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). We did not use any date or language restrictions in the electronic searches for trials. We last searched the electronic databases on 1 August 2012. The National Research Register (NRR) was last searched in 2007 after which the database was archived. We also checked the reference lists of articles and contacted researchers in the field.

SELECTION CRITERIA: We included randomised controlled trials (RCTs) comparing medications with surgery in adults with OAG.

DATA COLLECTION AND ANALYSIS: Two authors independently assessed trial quality and extracted data. We contacted study authors for missing information.

MAIN RESULTS: Four trials involving 888 participants with previously untreated OAG were included. Surgery was Scheie's procedure in one trial and trabeculectomy in three trials. In three trials, primary medication was usually pilocarpine, in one trial it was a beta-blocker.The most recent trial included participants with on average mild OAG. At five years, the risk of progressive visual field loss, based on a three unit change of a composite visual field score, was not significantly different according to initial medication or initial trabeculectomy (odds ratio (OR) 0.74, 95% confidence interval (CI) 0.54 to 1.01). In an analysis based on mean difference (MD) as a single index of visual field loss, the between treatment group difference in MD was -0.20 decibel (dB) (95% CI -1.31 to 0.91). For a subgroup with more severe glaucoma (MD -10 dB), findings from an exploratory analysis suggest that initial trabeculectomy was associated with marginally less visual field loss at five years than initial medication, (mean difference 0.74 dB (95% CI -0.00 to 1.48). Initial trabeculectomy was associated with lower average intraocular pressure (IOP) (mean difference 2.20 mmHg (95% CI 1.63 to 2.77) but more eye symptoms than medication (P = 0.0053). Beyond five years, visual acuity did not differ according to initial treatment (OR 1.48, 95% CI 0.58 to 3.81).From three trials in more severe OAG, there is some evidence that medication was associated with more progressive visual field loss and 3 to 8 mmHg less IOP lowering than surgery. In the longer-term (two trials) the risk of failure of the randomised treatment was greater with medication than trabeculectomy (OR 3.90, 95% CI 1.60 to 9.53; hazard ratio (HR) 7.27, 95% CI 2.23 to 25.71). Medications and surgery have evolved since these trials were undertaken.In three trials the risk of developing cataract was higher with trabeculectomy (OR 2.69, 95% CI 1.64 to 4.42). Evidence from one trial suggests that, beyond five years, the risk of needing cataract surgery did not differ according to initial treatment policy (OR 0.63, 95% CI 0.15 to 2.62).Methodological weaknesses were identified in all the trials.

AUTHORS' CONCLUSIONS: Primary surgery lowers IOP more than primary medication but is associated with more eye discomfort. One trial suggests that visual field restriction at five years is not significantly different whether initial treatment is medication or trabeculectomy. There is some evidence from two small trials in more severe OAG, that initial medication (pilocarpine, now rarely used as first line medication) is associated with more glaucoma progression than surgery. Beyond five years, there is no evidence of a difference in the need for cataract surgery according to initial treatment.The clinical and cost-effectiveness of contemporary medication (prostaglandin analogues, alpha2-agonists and topical carbonic anhydrase inhibitors) compared with primary surgery is not known.Further RCTs of current medical treatments compared with surgery are required, particularly for people with severe glaucoma and in black ethnic groups. Outcomes should include those reported by patients. Economic evaluations are required to inform treatment policy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract
BACKGROUND:
Glaucoma is a leading cause of blindness. Early detection is advocated but there is insufficient evidence from randomized controlled trials (RCTs) to inform health policy on population screening. Primarily, there is no agreed screening intervention. For a screening programme, agreement is required on the screening tests to be used, either individually or in combination, the person to deliver the test and the location where testing should take place. This study aimed to use ophthalmologists (who were experienced glaucoma subspecialists), optometrists, ophthalmic nurses and patients to develop a reduced set of potential screening tests and testing arrangements that could then be explored in depth in a further study of their feasibility for evaluation in a glaucoma screening RCT.
METHODS:
A two-round Delphi survey involving 38 participants was conducted. Materials were developed from a prior evidence synthesis. For round one, after some initial priming questions in four domains, specialists were asked to nominate three screening interventions, the intervention being a combination of the four domains; target population, (age and higher risk groups), site, screening test and test operator (provider). More than 250 screening interventions were identified. For round two, responses were condensed into 72 interventions and each was rated by participants on a 0-10 scale in terms of feasibility.
RESULTS:
Using a cut-off of a median rating of feasibility of =5.5 as evidence of agreement of intervention feasibility, six interventions were identified from round 2. These were initiating screening at age 50, with a combination of two or three screening tests (varying combinations of tonometry/measures of visual function/optic nerve damage) organized in a community setting with an ophthalmic trained technical assistant delivering the tests. An alternative intervention was a 'glaucoma risk score' ascertained by questionnaire. The advisory panel recommended that further exploration of the feasibility of screening higher risk populations and detailed specification of the screening tests was required.
CONCLUSIONS:
With systematic use of expert opinions, a shortlist of potential screening interventions was identified. Views of users, service providers and cost-effectiveness modeling are now required to identify a feasible intervention to evaluate in a future glaucoma screening trial.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: To estimate the prevalence of primary angle closure glaucoma (PACG) in European derived populations.

METHOD: Systematic review and modelling of PACG prevalence data from population studies. PACG was defined according to the ISGEO definition requiring structural and/or functional evidence of glaucomatous optic neuropathy. Prevalence estimates were applied to the 2010 United Nations projected population figures to estimate case numbers.

RESULTS: The prevalence of PACG in those 40 years or more is 0.4% (95% CI 0.3% to 0.5%). Age-specific prevalence values are 0.02% (CI 0.00 to 0.08) for those 40-49 years, 0.60% (0.27 to 1.00) for those 50-59 years, 0.20% (0.06 to 0.42) for those 60-69 years and 0.94% (0.63 to 1.35) for those 70 years and older. Three-quarters of all cases occur in female subjects (3.25 female to 1 male; CI 1.76 to 5.94).

CONCLUSION: This analysis provides a current evidence-based estimate of PACG prevalence in European derived populations and suggests there are 130,000 people in the UK, 1.60 million people in Europe and 581,000 people in the USA with PACG today. Accounting for ageing population structures, cases are predicted to increase by 19% in the UK, 9% in Europe and 18% in the USA within the next decade. PACG is more common than previously thought, and all primary glaucoma cases should be considered to be PACG until the anterior chamber angle is shown to be open on gonioscopy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The purpose of this study was to estimate costs and quality of life (QoL) of late-stage glaucoma patients in 4 European countries. Methods: Retrospective review of medical charts of patients with POAG who were followed in a low-vision or vision rehabilitation center in one of 4 countries for at least 1 year was used to determine patient characteristics, health status, and health care resource use. Visual impairment was measured by best-corrected visual acuity (Snellen score). Patients were also interviewed over the telephone in order to assess their health-related QoL (using EuroQol EQ-5D) and use of resources including: the number of visits to rehabilitation centers, visits to hospital and non-hospital specialists, the use of low-vision devices, medication, tests, and the use of hired home help. The costs associated with resource use were calculated from the perspective of a third-party payer of health and social care based on resource usage and unit costs in each country. Results: Patients undergoing visual rehabilitation in France (n=21), Denmark (n=59), Germany (n=60), and the United Kingdom (n=22) were identified, interviewed and had their medical charts reviewed. Annual maintenance costs of late-stage glaucoma amounted to €830 (±445) on average. Average home help costs were more than 3 times higher. QoL, on average, was 0.65 (±0.28). QoL was positively correlated with the level of visual acuity in the patients' best eye. On the other hand, visual acuity was also positively correlated to health care costs, but negatively correlated to costs of home help. Conclusions: The study was limited by its observational, uncontrolled design. The finding that late-stage glaucoma is associated with higher home help costs than health care maintenance costs suggests that potential savings from a better preventive treatment are to be found for social care payers rather than health care payers. © 2008 Informa UK Ltd All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To assess whether open angle glaucoma (OAG) screening meets the UK National Screening Committee criteria, to compare screening strategies with case finding, to estimate test parameters, to model estimates of cost and cost-effectiveness, and to identify areas for future research. Data sources: Major electronic databases were searched up to December 2005. Review methods: Screening strategies were developed by wide consultation. Markov submodels were developed to represent screening strategies. Parameter estimates were determined by systematic reviews of epidemiology, economic evaluations of screening, and effectiveness (test accuracy, screening and treatment). Tailored highly sensitive electronic searches were undertaken. Results: Most potential screening tests reviewed had an estimated specificity of 85% or higher. No test was clearly most accurate, with only a few, heterogeneous studies for each test. No randomised controlled trials (RCTs) of screening were identified. Based on two treatment RCTs, early treatment reduces the risk of progression. Extrapolating from this, and assuming accelerated progression with advancing disease severity, without treatment the mean time to blindness in at least one eye was approximately 23 years, compared to 35 years with treatment. Prevalence would have to be about 3-4% in 40 year olds with a screening interval of 10 years to approach cost-effectiveness. It is predicted that screening might be cost-effective in a 50-year-old cohort at a prevalence of 4% with a 10-year screening interval. General population screening at any age, thus, appears not to be cost-effective. Selective screening of groups with higher prevalence (family history, black ethnicity) might be worthwhile, although this would only cover 6% of the population. Extension to include other at-risk cohorts (e.g. myopia and diabetes) would include 37% of the general population, but the prevalence is then too low for screening to be considered cost-effective. Screening using a test with initial automated classification followed by assessment by a specialised optometrist, for test positives, was more cost-effective than initial specialised optometric assessment. The cost-effectiveness of the screening programme was highly sensitive to the perspective on costs (NHS or societal). In the base-case model, the NHS costs of visual impairment were estimated as £669. If annual societal costs were £8800, then screening might be considered cost-effective for a 40-year-old cohort with 1% OAG prevalence assuming a willingness to pay of £30,000 per quality-adjusted life-year. Of lesser importance were changes to estimates of attendance for sight tests, incidence of OAG, rate of progression and utility values for each stage of OAG severity. Cost-effectiveness was not particularly sensitive to the accuracy of screening tests within the ranges observed. However, a highly specific test is required to reduce large numbers of false-positive referrals. The findings that population screening is unlikely to be cost-effective are based on an economic model whose parameter estimates have considerable uncertainty, in particular, if rate of progression and/or costs of visual impairment are higher than estimated then screening could be cost-effective. Conclusions: While population screening is not cost-effective, the targeted screening of high-risk groups may be. Procedures for identifying those at risk, for quality assuring the programme, as well as adequate service provision for those screened positive would all be needed. Glaucoma detection can be improved by increasing attendance for eye examination, and improving the performance of current testing by either refining practice or adding in a technology-based first assessment, the latter being the more cost-effective option. This has implications for any future organisational changes in community eye-care services. Further research should aim to develop and provide quality data to populate the economic model, by conducting a feasibility study of interventions to improve detection, by obtaining further data on costs of blindness, risk of progression and health outcomes, and by conducting an RCT of interventions to improve the uptake of glaucoma testing. © Queen's Printer and Controller of HMSO 2007. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. To determine the agreement between observers in estimating the configuration of the human anterior chamber angle (ACA) using ultrasound biomicroscopy (UBM). Methods. Two masked clinicians used UBM images to estimate, in 41 eyes, the configuration of the ACA, especially (1) the position of contact between the peripheral iris and the inside of the eye wall, (2) the angularity of the approach to the ACA, and (3) the curvature of the peripheral iris. Agreement between observers was evaluated by the kappa statistic. Results. Inter-observer agreement in assessing the iris insertion (kappa = 0.79), angular width (Kappa = 0.95), and the peripheral iris curvature (kappa = 0.84) was high. Conclusions. The agreement between observers in evaluating the anterior chamber angle configuration by UBM was excellent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: A peripheral iridotomy (PI) is the treatment of choice for pupillary block. In this study we investigated the effect of enlarging the size of a small PI on the anterior chamber angle in patients with angle closure using ultrasound biomicroscopy (UBM). Patients and Methods: Patients who had been treated with laser peripheral iridotomy for angle closure and were identified to have a small patent PI (<100 µm) with still appositionally closed anterior chamber angle were selected prospectively. The anterior chamber angle was assessed using UBM. The angle opening distance 500 µm from the scleral spur (AOD500) as well as the anterior and posterior chamber depth (ACD and PCD) 1000 µm from the scleral spur was measured. In addition, the ACD/PCD ratio was calculated. Afterwards, the PI was enlarged using an Nd: YAG laser and the UBM measurements were repeated as described above. Results: Six eyes of six patients were examined. After the enlargement of the PI the average AOD500 increased from 109 µm (±36) to 147 µm (±40) (p

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To determine and compare the corneal biomechanical properties between eyes with primary open angle glaucoma (POAG) and eyes with normal tension glaucoma (NTG). PATIENTS AND METHODS: Prospective cross-sectional study. Consecutive eligible POAG and NTG patients attending the Glaucoma Clinic had assessment of their corneal biomechanical properties-corneal hysteresis (CH) and corneal resistance factor (CRF)-using the Ocular Response Analyzer by an observer masked to the diagnosis. Exclusion criteria included previous intraocular surgery, corneal pathology, inflammatory connective tissue disease, and refraction of 5-dimensional or over. If both eyes were eligible, then the right eye was used for analysis. The main outcome measures were corneal hysteresis and CRF measurements. Data analysis was performed using the t test and general linear model. RESULTS: Eighty-one patients (80 whites) were analyzed. Forty had NTG, whereas 41 had POAG. Thirty-five were females. There was a statistically significant difference in mean CH (NTG 9.6±1.3 mm Hg; POAG 9.0±1.4 mm Hg; P=0.01), but not in mean CRF (NTG 9.9±1.4; POAG 10.8±1.7; P=0.06). The highest recorded Goldmann applanation intraocular pressure (IOP) was statistically significantly associated with lower CH (P=0.01) and higher CRF (P=0.02). CONCLUSIONS: There was a small but statistically significant difference in the mean CH between POAG and NTG (CH was higher in NTG). The highest recorded Goldmann applanation IOP was also statistically significantly correlated with lower CH and higher CRF, suggesting that alterations to the corneal biomechanical properties may occur as a result of chronic raised IOP in POAG. © 2008 by Lippincott Williams & Wilkins.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study is to describe the ocular and demographic features of Caucasian patients newly presenting with primary angle closure glaucoma and the proportion of workload it represents at a tertiary university hospital glaucoma service. Methods: A retrospective case notes review was conducted for all Caucasian patients newly diagnosed with narrow angles, primary angle closure, acute primary angle closure and primary angle closure glaucoma that were seen over a period of 2 years. Demographic and ocular variables were compared and statistical analysis was carried out with the paired t -test and chi-squared test. Number of primary open angle closure glaucoma and acute angle closure cases were compared with total number of new referrals to the department, new patients diagnosed with glaucoma and population numbers for the North East of Scotland. Results: One hundred and four patients were analysed. Twenty-four (23.1%) had narrow angles, 30 (28.8%) had primary angle closure and 50 (48.1%) had primary angle closure glaucoma. Twelve (11.5%) presented with acute primary angle closure. There was no significant difference for gender, age, hypermetropia or visual acuity between groups. Primary angle closure glaucoma constituted 22.9% (50/128) of newly diagnosed glaucoma cases. Based on the 2001 Scotland census, the crude annual incidence of newly diagnosed primary angle closure glaucoma was estimated at 14.8 per 100000 and 3.6 per 100000 for acute primary angle closure in the over-45-year-old population. Conclusion: Our study confirms that primary angle closure glaucoma is uncommon in Caucasians, but not as rare as originally perceived as it makes up a fair proportion (22.9%) of glaucoma workload. © 2009 The Authors Journal Compilation © 2009 Royal Australian and New Zealand College of Ophthalmologists.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Angle-closure glaucoma is a leading cause of irreversible blindness in the world. Treatment is aimed at opening the anterior chamber angle and lowering the IOP with medical and/or surgical treatment (e.g. trabeculectomy, lens extraction). Laser iridotomy works by eliminating pupillary block and widens the anterior chamber angle in the majority of patients. When laser iridotomy fails to open the anterior chamber angle, laser iridoplasty may be recommended as one of the options in current standard treatment for angle-closure. Laser peripheral iridoplasty works by shrinking and pulling the peripheral iris tissue away from the trabecular meshwork. Laser peripheral iridoplasty can be used for crisis of acute angle-closure and also in non-acute situations.

OBJECTIVES: To assess the effectiveness of laser peripheral iridoplasty in the treatment of narrow angles (i.e. primary angle-closure suspect), primary angle-closure (PAC) or primary angle-closure glaucoma (PACG) in non-acute situations when compared with any other intervention. In this review, angle-closure will refer to patients with narrow angles (PACs), PAC and PACG.

SEARCH METHODS: We searched CENTRAL (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library 2011, Issue 12), MEDLINE (January 1950 to January 2012), EMBASE (January 1980 to January 2012), Latin American and Caribbean Literature on Health Sciences (LILACS) (January 1982 to January 2012), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com), ClinicalTrials.gov (www.clinicaltrials.gov) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en). There were no date or language restrictions in the electronic searches for trials. The electronic databases were last searched on 5 January 2012.

SELECTION CRITERIA: We included only randomised controlled trials (RCTs) in this review. Patients with narrow angles, PAC or PACG were eligible. We excluded studies that included only patients with acute presentations, using laser peripheral iridoplasty to break acute crisis.

DATA COLLECTION AND ANALYSIS: No analysis was carried out as only one trial was included in the review.

MAIN RESULTS: We included one RCT with 158 participants. The trial reported laser peripheral iridoplasty as an adjunct to laser peripheral iridotomy compared to iridotomy alone. The authors report no superiority in using iridoplasty as an adjunct to iridotomy for IOP, number of medications or need for surgery.

AUTHORS' CONCLUSIONS: There is currently no strong evidence for laser peripheral iridoplasty's use in treating angle-closure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Angle-closure glaucoma is a leading cause of irreversible blindness in the world. Treatment is aimed at opening the anterior chamber angle and lowering the IOP with medical and/or surgical treatment (e.g. trabeculectomy, lens extraction). Laser iridotomy works by eliminating pupillary block and widens the anterior chamber angle in the majority of patients. When laser iridotomy fails to open the anterior chamber angle, laser iridoplasty may be recommended as one of the options in current standard treatment for angle-closure. Laser peripheral iridoplasty works by shrinking and pulling the peripheral iris tissue away from the trabecular meshwork. Laser peripheral iridoplasty can be used for crisis of acute angle-closure and also in non-acute situations. OBJECTIVES: To assess the effectiveness of laser peripheral iridoplasty in the treatment of narrow angles (i.e. primary angle-closure suspect), primary angle-closure (PAC) or primary angle-closure glaucoma (PACG) in non-acute situations when compared with any other intervention. In this review, angle-closure will refer to patients with narrow angles, PAC and PACG. SEARCH STRATEGY: We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (which contains the Cochrane Eyes and Vision Group Trials Register) (The Cochrane Library), MEDLINE, EMBASE and LILACS (Latin American and Caribbean Literature on Health Sciences). The databases were last searched on 11 February 2008. SELECTION CRITERIA: Only randomised controlled trials (RCTs) were eligible for inclusion in this review. Patients with narrow angles, PAC or PACG were eligible. Studies that included only patients with acute presentations, using laser peripheral iridoplasty to break acute crisis were excluded. DATA COLLECTION AND ANALYSIS: No analysis was carried out due to lack of trials. MAIN RESULTS: There were no RCTs assessing laser peripheral iridoplasty in the non-acute setting of angle-closure. AUTHORS' CONCLUSIONS: There is currently no strong evidence for laser peripheral iridoplasty's use in treating angle-closure.