947 resultados para common method variance


Relevância:

20.00% 20.00%

Publicador:

Resumo:

To determine the most adequate number and size of tissue microarray (TMA) cores for pleomorphic adenoma immunohistochemical studies. Eighty-two pleomorphic adenoma cases were distributed in 3 TMA blocks assembled in triplicate containing 1.0-, 2.0-, and 3.0-mm cores. Immunohistochemical analysis against cytokeratin 7, Ki67, p63, and CD34 were performed and subsequently evaluated with PixelCount, nuclear, and microvessel software applications. The 1.0-mm TMA presented lower results than 2.0- and 3.0-mm TMAs versus conventional whole section slides. Possibly because of an increased amount of stromal tissue, 3.0-mm cores presented a higher microvessel density. Comparing the results obtained with one, two, and three 2.0-mm cores, there was no difference between triplicate or duplicate TMAs and a single-core TMA. Considering the possible loss of cylinders during immunohistochemical reactions, 2.0-mm TMAs in duplicate are a more reliable approach for pleomorphic adenoma immunohistochemical study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An HPLC-PAD method using a gold working electrode and a triple-potential waveform was developed for the simultaneous determination of streptomycin and dihydrostreptomycin in veterinary drugs. Glucose was used as the internal standard, and the triple-potential waveform was optimized using a factorial and a central composite design. The optimum potentials were as follows: amperometric detection, E1=-0.15V; cleaning potential, E2=+0.85V; and reactivation of the electrode surface, E3=-0.65V. For the separation of the aminoglycosides and the internal standard of glucose, a CarboPac™ PA1 anion exchange column was used together with a mobile phase consisting of a 0.070 mol L(-1) sodium hydroxide solution in the isocratic elution mode with a flow rate of 0.8 mL min(-1). The method was validated and applied to the determination of streptomycin and dihydrostreptomycin in veterinary formulations (injection, suspension and ointment) without any previous sample pretreatment, except for the ointments, for which a liquid-liquid extraction was required before HPLC-PAD analysis. The method showed adequate selectivity, with an accuracy of 98-107% and a precision of less than 3.9%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to develop a methodology using Raman hyperspectral imaging and chemometric methods for identification of pre- and post-blast explosive residues on banknote surfaces. The explosives studied were of military, commercial and propellant uses. After the acquisition of the hyperspectral imaging, independent component analysis (ICA) was applied to extract the pure spectra and the distribution of the corresponding image constituents. The performance of the methodology was evaluated by the explained variance and the lack of fit of the models, by comparing the ICA recovered spectra with the reference spectra using correlation coefficients and by the presence of rotational ambiguity in the ICA solutions. The methodology was applied to forensic samples to solve an automated teller machine explosion case. Independent component analysis proved to be a suitable method of resolving curves, achieving equivalent performance with the multivariate curve resolution with alternating least squares (MCR-ALS) method. At low concentrations, MCR-ALS presents some limitations, as it did not provide the correct solution. The detection limit of the methodology presented in this study was 50μgcm(-2).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the most important properties of quantum dots (QDs) is their size. Their size will determine optical properties and in a colloidal medium their range of interaction. The most common techniques used to measure QD size are transmission electron microscopy (TEM) and X-ray diffraction. However, these techniques demand the sample to be dried and under a vacuum. This way any hydrodynamic information is excluded and the preparation process may alter even the size of the QDs. Fluorescence correlation spectroscopy (FCS) is an optical technique with single molecule sensitivity capable of extracting the hydrodynamic radius (HR) of the QDs. The main drawback of FCS is the blinking phenomenon that alters the correlation function implicating in a QD apparent size smaller than it really is. In this work, we developed a method to exclude blinking of the FCS and measured the HR of colloidal QDs. We compared our results with TEM images, and the HR obtained by FCS is higher than the radius measured by TEM. We attribute this difference to the cap layer of the QD that cannot be seen in the TEM images.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A capillary zone electrophoresis (CE) method was developed for the determination of the biocide 2,2-dibromo-3-nitrilo-propionamide (DBNPA) in water used in cooling systems. The biocide is indirectly determined by CE measurement of the concentration of bromide ions produced by the reaction between the DBNPA and bisulfite. The relationship between the bromide peak areas and the DBNPA concentrations showed a good linearity and a coefficient of determination (R(2)) of 0.9997 in the evaluated concentration range of 0-75 μmol L(-1). The detection and quantification limits for DBNPA were 0.23 and 0.75 μmol L(-1), respectively. The proposed CE method was successfully applied for the analysis of samples of tap water and cooling water spiked with DBNPA. The intra-day and inter-day (intermediary) precisions were lower than 2.8 and 6.2%, respectively. The DBNPA concentrations measured by the CE method were compared to the values obtained by a spectrophotometric method and were found to agree well.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective Patients with mesial temporal lobe epilepsy (MTLE) may present unstable pattern of seizures. We aimed to evaluate the occurrence of relapse-remitting seizures in MTLE with (MTLE-HS) and without (MTLE-NL) hippocampal sclerosis. Method We evaluated 172 patients with MTLE-HS (122) or MTLE-NL (50). Relapse-remitting pattern was defined as periods longer than two years of seizure-freedom intercalated with seizure recurrence. Infrequent seizures was considered as up to three seizures per year and frequent seizures as any period of seizures higher than that. Results Thirty-seven (30%) MTLE-HS and 18 (36%) MTLE-NL patients had relapse-remitting pattern (X2, p = 0.470). This was more common in those with infrequent seizures (X2, p < 0.001). Twelve MTLE-HS and one MTLE-NL patients had prolonged seizure remission between the first and second decade of life (X2, p = 0.06). Conclusion Similar proportion of MTLE-HS or MTLE-NL patients present relapse-remitting seizures and this occurs more often in those with infrequent seizures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sunlight exposure causes several types of injury to humans, especially on the skin; among the most common harmful effects due to ultraviolet (UV) exposure are erythema, pigmentation and lesions in DNA, which may lead to cancer. These long-term effects are minimized with the use of sunscreens, a class of cosmetic products that contains UV filters as the main component in the formulation; such molecules can absorb, reflect or diffuse UV rays, and can be used alone or as a combination to broaden the protection on different wavelengths. Currently, worldwide regulatory agencies define which ingredients and what quantities must be used in each country, and enforce companies to conduct tests that confirm the Sun Protection Factor (SPF) and the UVA (Ultraviolet A) factor. Standard SPF determination tests are currently conducted in vivo, using human subjects. In an industrial mindset, apart from economic and ethical reasons, the introduction of an in vitro method emerges as an interesting alternative by reducing risks associated to UV exposure on tests, as well as providing assertive analytical results. The present work aims to describe a novel methodology for SPF determination directly from sunscreen formulations using the previously described cosmetomics platform and mass spectrometry as the analytical methods of choice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lateral pterygoid muscle (LPM) plays an important role in jaw movement and has been implicated in Temporomandibular disorders (TMDs). Migraine has been described as a common symptom in patients with TMDs and may be related to muscle hyperactivity. This study aimed to compare LPM volume in individuals with and without migraine, using segmentation of the LPM in magnetic resonance (MR) imaging of the TMJ. Twenty patients with migraine and 20 volunteers without migraine underwent a clinical examination of the TMJ, according to the Research Diagnostic Criteria for TMDs. MR imaging was performed and the LPM was segmented using the ITK-SNAP 1.4.1 software, which calculates the volume of each segmented structure in voxels per cubic millimeter. The chi-squared test and the Fisher's exact test were used to relate the TMD variables obtained from the MR images and clinical examinations to the presence of migraine. Logistic binary regression was used to determine the importance of each factor for predicting the presence of a migraine headache. Patients with TMDs and migraine tended to have hypertrophy of the LPM (58.7%). In addition, abnormal mandibular movements (61.2%) and disc displacement (70.0%) were found to be the most common signs in patients with TMDs and migraine. In patients with TMDs and simultaneous migraine, the LPM tends to be hypertrophic. LPM segmentation on MR imaging may be an alternative method to study this muscle in such patients because the hypertrophic LPM is not always palpable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The interactions of carbon nanotubes with pesticides, such as carbofuran, classical contaminants (e.g., pesticides, polyaromatic hydrocarbons, heavy metals, and dyes) and emerging contaminants, including endocrine disruptors, are critical components of the environmental risks of this important class of carbon-based nanomaterials. In this work, we studied the modulation of acute carbofuran toxicity to the freshwater fish Nile tilapia (Oreochromis niloticus) by nitric acid treated multiwalled carbon nanotubes, termed HNO3-MWCNT. Nitric acid oxidation is a common chemical method employed for the purification, functionalisation and aqueous dispersion of carbon nanotubes. HNO3-MWCNT were not toxic to Nile tilapia at concentrations ranging from 0.1 to 3.0 mg/L for exposure times of up to 96 h. After 24, 48, 72 and 96 h, the LC50 values of carbofuran were 4.0, 3.2, 3.0 and 2.4 mg/mL, respectively. To evaluate the influence of carbofuran-nanotube interactions on ecotoxicity, we exposed the Nile tilapia to different concentrations of carbofuran mixed together with a non-toxic concentration of HNO3-MWCNT (1.0 mg/L). After 24, 48, 72, and 96 h of exposure, the LC50 values of carbofuran plus nanotubes were 3.7, 1.6, 0.7 and 0.5 mg/L, respectively. These results demonstrate that HNO3-MWCNT potentiate the acute toxicity of carbofuran, leading to a more than five-fold increase in the LC50 values. Furthermore, the exposure of Nile tilapia to carbofuran plus nanotubes led to decreases in both oxygen consumption and swimming capacity compared to the control. These findings indicate that carbon nanotubes could act as pesticide carriers affecting fish survival, metabolism and behaviour.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flow injection method for the quantitative analysis of ketoconazole in tablets, based on the reaction with iron (III) ions, is presented. Ketoconazole forms a red complex with iron ions in an acid medium, with maximum absorbance at 495 nm. The detection limit was estimated to be 1×10--4 mol L-1; the quantitation limit is about 3×10--4 mol L-1 and approximately 30 determinations can be performed in an hour. The results were compared with those obtained with a reference HPLC method. Statistical comparisons were done using the Student's t procedure and the F test. Complete agreement was found at the 0.95 significance level between the proposed flow injection and the HPLC procedures. The two methods present similar precision, i.e., for HPLC the mean relative standard deviation was ca. 1.2% and for FIA ca. 1.6%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A rapid and low cost method to determine Cr(VI) in soils based upon alkaline metal extraction at room temperature is proposed as a semi-quantitative procedure to be performed in the field. A color comparison with standards with contents of Cr(VI) in the range of 10 to 150 mg kg-1 was used throughout. For the different types of soils studied, more than 75% of the fortified soluble Cr(VI) were recovered for all levels of spike tested for both the proposed and standard methods. Recoveries of 83 and 99% were obtained for the proposed and the standard methods, respectively, taking into account the analysis of a heavily contaminated soil sample.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Antimony is a common catalyst in the synthesis of polyethylene terephthalate used for food-grade bottles manufacturing. However, antimony residues in final products are transferred to juices, soft drinks or water. The literature reports mentions of toxicity associated to antimony. In this work, a green, fast and direct method to quantify antimony, sulfur, iron and copper, in PET bottles by X-ray fluorescence spectrometry is presented. 2.4 to 11 mg Sb kg-1 were found in 20 samples analyzed. The coupling of the multielemental technique to chemometric treatment provided also the possibility to classify PET samples between bottle-grade PET/recycled PET blends by Fe content.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work aimed to create a methodology to evaluate the pulverization process with the use of quality tools. It was listed the primary factors, secondary factors, tertiary factors and, with the check list tool support, the list was elaborated. It was evaluated the factors labor, agriculture machine, material and method of 32 pulverization process before pesticide application, in that each factor received a punctuation, having as total sum of 750 points. The medium punctuation to the factors labor, agriculture machine, material and method was 78; 211; 49; 20 and 94 points, respectively. The sum of the factors points for the 32 processes, the minimum value found was 230 and maximum was 620 points. With the proposed methodology, can be identify which common causes of the processes can affect its result.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mental health problems are common in primary health care, particularly anxiety and depression. This study aims to estimate the prevalence of common mental disorders and their associations with socio-demographic characteristics in primary care in Brazil (Family Health Strategy). It involved a multicenter cross-sectional study with patients from Rio de Janeiro, São Paulo, Fortaleza (Ceará State) and Porto Alegre (Rio Grande do Sul State), assessed using the General Health Questionnaire (GHQ-12) and the Hospital Anxiety and Depression Scale (HAD). The rate of mental disorders in patients from Rio de Janeiro, São Paulo, Fortaleza and Porto Alegre were found to be, respectively, 51.9%, 53.3%, 64.3% and 57.7% with significant differences between Porto Alegre and Fortaleza compared to Rio de Janeiro after adjusting for confounders. Prevalence proportions of mental problems were especially common for females, the unemployed, those with less education and those with lower incomes. In the context of the Brazilian government's moves towards developing primary health care and reorganizing mental health policies it is relevant to consider common mental disorders as a priority alongside other chronic health conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The point-centred quarter method (63 points) was applied in Porto Ferreira State Reserve (21º49'S and 47º25'W) in an area (1.08ha) on the right margin of Moji Guaçu river, including two woody individuals per quarter - one with DBH < 10cm and at least 130cm high, the other with DBH > 10cm. The results obtained were compared with those published by other authors for a riparian forest (Mata da Figueira) at Moji Guaçu Ecological Station (about 100 km upstream on the same river). At Porto Ferreira 107 species were found, of which 80 were exclusive, compared with the Mata da Figueira where of the 59 species listed, 31 were exclusive. The two area shared 27 common species, thus accounting for a low Sørensen similarity of 48.6%. The great environmental heterogeneity of the floodplains, as well as the degree of anthropic disturbance, could account for this floristic variation. The greatest numbers of species were shown by Leguminosae (20), Myrtaceae (17), Rutaceae (9), Euphorbiaceae (7), and Lauraceae, Meliaceae, Moraceae and Rubiaceae (6 species each). There appears to be little difference at the family level among the periodically flooded and non-flooded forests of the State of São Paulo, but the species show different degreees of preference for habitat. The floristic composition of the two areas presented a mixture of typical species with others of non-flooded forests. The latter would occur on the floodplain probably by a) adaptation of the root system to relatively short flooding periods; b) shorter periods of flooding on the higher points of the microrelief of the floodplain, and c) greater aeration due to running water.