827 resultados para calibração de TDR


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of treated sewage effluent (TSE) combined with the subsurface drip irrigation (SDI) method in agriculture can decrease the costs of agricultural production, in attempts to fertigate crops more efficiently. In this study it was compared the dimensions of the wet bulb formed by the application of TSE and municipal water supply (MWS) in an Oxisoil. We have evaluated the effect of water quality and discharge between drippers used in sugarcane crop. Three trenches were opened and 21 three-rod TDR probes were setup in a mesh and a dripper was buried at 0.30 m, for each constant discharge of 1.0 L h-1and 1.6 L h-1. Comparing results from different wetted soil profiles it was observed that the vertical and horizontal dimensions of the wet bulb are similar for both MWS and TSE, being peculiars according to the discharges used and volume applied. Regardless the water quality, an increase of 60% in discharge decreased the deepest infiltration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RESUMO Visando à otimização do uso da água na produção de alimentos, este artigo teve como objetivo avaliar o desempenho da TDR e de um acionador automático para irrigação na produção da alface em solos com diferentes doses de um polímero hidrofílico. Em casa de vegetação, foram realizados dois ensaios em vasos de 3 litros cultivados com alface. O primeiro foi realizado na primavera de 2011, utilizando 2 texturas de solo (arenosa e argilosa) e a presença/ausência do hidrogel. O segundo ensaio foi realizado no outono de 2012, utilizando 4 doses de hidrogel (0; 8; 16 e 24 g por vaso) no solo de textura arenosa. Aos 38 (2011) e 44 (2012) dias após o transplantio (DAT) das mudas, foram realizadas as colheitas e a avaliação das plantas cultivadas. O hidrogel não representou uma fonte de erros para o funcionamento da TDR, e o dispositivo acionador automático para irrigação respondeu adequadamente à presença do hidrogel nos solos com diferentes texturas. Em geral, foi verificada maior eficiência do uso da água nas plantas desenvolvidas na presença do hidrogel. As plantas cultivadas em solo com 16 g por vaso de hidrogel destacaram-se em massa seca e fresca da parte aérea.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A utilização de sacos plásticos graduados para a medida da vazão de pulverizadores está ba stante di fundida entre técnicos e agricultores. 0 seu emprego é simples, consistindo, basicamente, em se coletar o líquido pulverizado por um bico durante o período equivalente ao deslocamento de 50 metros. O volume coletado é indicado numa escala graduada impr essa nos sacos calib rad ores e fornece diretament e a vazão em 1/ha. Firmas que comercializam os agro fármacos distribuem esses instrumentos aos agricultores, muitas vezes com propósitos puramente promocionais. Cinco sacos graduados de cada uma das 6 marcas diferentes foram aferidos. Agua a 20°C foi adicionada até as marcas de 100 1/ha, 250 1/ha e 400 1/ha. Esses volumes foram medidos em pro veta graduada e o volume real de pulverização foi calculado. Todos os saquinhos testados mostraram erros, em alguns bastante elevados, atingindo desvios de até 35,2%. Considerando esses resultados, é recomendada maior atenção na fabricação desses instrumentos. São sugeridas também algumas modificações da maneira de imprimir a escala e no conteúdo das instruções de uso.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabalho teve como objetivo analisar a metodologia para avaliação do impacto ambiental causado pelo uso de herbicidas no controle de macrófitas. O desenho e a construção dos mesocosmos são descritos em detalhes, como também a forma como foram inseridos lâminas para coleta e medida da comunidade perifítica e sedimento para avaliação da comunidade bentônica. O método utilizado foi o de fluxo contínuo, e vários parâmetros de qualidade de água foram medidos, além da determinação de resíduos na coluna d'água e no sedimento. A intenção de se utilizar um método de fluxo contínuo foi buscar uma situação mais próxima da realidade, a fim de que os resultados obtidos possam espelhar com maior exatidão os possíveis riscos provenientes do uso de substâncias químicas no controle das macrófitas. Alguns ajustes devem ser feitos nessa metodologia para melhor caracterização dos efluentes e calibração do sistema.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Neste trabalho, foi realizada a purificação, a obtenção do padrão de sorgoleone (2 - hidroxi - 5 - metoxi - 3 - [(8'Z,11'Z)-8',11',14'-pentadecatrieno]-p-benzoquinona) e a quantificação desse marcador em raízes primárias de sorgo. As sementes de sorgo foram desinfectadas, colocadas em placas gerbox opacas e acondicionadas em câmara de germinação a 30 ºC durante sete dias no escuro. Posteriormente, a extração foi feita mergulhando-se as raízes por 5 min em solução de ácido acético glacial em diclorometano 0,0025% v/v. A quantificação de sorgoleone nos extratos obtidos foi feita por cromatografia líquida de alta eficiência (HPLC), utilizando-se uma curva de calibração. Foi avaliado o efeito do armazenamento de extratos e de raízes, utilizando-se três repetições para cada tratamento. Os extratos de raízes recém-coletadas foram armazenados a -20 ºC por 0, 1, 3, 5, 7, 14 e 21 dias. As raízes foram coletadas e imediatamente congeladas (20 ºC) e armazenadas pelo mesmo período, quando foram submetidas à extração. Não foi observada diferença significativa entre a quantidade de sorgoleone em extratos armazenados e a de não armazenados, sendo observado o mesmo resultado em extratos obtidos de raízes frescas e armazenadas. Os resultados obtidos mostram que o armazenamento por até 21 dias não altera o conteúdo de sorgoleone nos extratos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RESUMOO potencial de cobertura vegetal do solo por plantas cultivadas é um parâmetro importante para a seleção de espécies forrageiras adaptadas a uma determinada região. Contudo, uma das restrições de uso dessa variável está associada à adoção da técnica de estimativa, uma vez que existem diferentes formas de cálculo. Diante disso, objetivou-se comparar as frações de cobertura do solo cultivado com Urochloa ruziziensis e Urochloa spp., utilizando-se três técnicas de medida: avaliação visual, avaliação por intercepto ou transecto e avaliação por imagens fotográficas. Para isso, foram conduzidos seis ensaios em campo, em delineamento de blocos casualizados. Os ensaios 1, 2 e 3 foram formados pela espécie Urochloa ruziziensis e compostos por três tratamentos, representados pelas três técnicas de medida (visual, por intercepto ou transecto e por imagens fotográficas), com oito repetições. Os ensaios 4, 5 e 6 tiveram arranjo fatorial 2 x 3, sendo o fator A formado por duas espécies de capim-braquiária (Urochloa ruziziensis e Urochloa spp. cv. Mulato II) e o fator B pelas três técnicas de medida (visual, por transecto e por imagens fotográficas), com quatro repetições. As medidas das frações de cobertura do solo foram tomadas aos 30, 60 e 90 dias após a semeadura. Constatou-se que, quanto maior a uniformidade da cobertura do solo pelas plantas forrageiras, mais próximos são os valores das frações de cobertura vegetal obtidas pelas três técnicas de estimativa. As técnicas de estimativa visual e por transecto da fração de cobertura do solo foram consideradas semelhantes, já a eficiência da medida pela técnica com imagens fotográficas depende da calibração individual de cada imagem.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cell proliferation and migration in the intestinal crypts, and cell migration in the villus are controlled by different mechanisms in adult rats. In the present study, weanling rats and fasting rats were used to quantitatively study the correlation of cell cycle parameters and epithelial cell migration in crypts and intestinal villi. Eighteen-day-old rats received a single injection of tritiated thymidine [3H]TdR (23:00 h); half of the pups were submitted to fasting 5 h earlier. Cell proliferation was determined in radioautographs of jejunal crypts, on the basis of the labeling indices (LI) taken 1, 8, 13 and 19 h after [3H]TdR. The results showed that the labeling index did not differ 1 h or 19 h after [3H]TdR between the fed (38.7% or 48%) and fasting groups (34.6% or 50.4%). The modified method of grain count halving indicated that cell cycle time did not differ between fed (16.5 h) and fasting rats (17.8 h); the growth fraction, however, had lower values in fasting (59%) than in fed rats (77%). Cell migration in the crypt, estimated by the LI obtained for each cell position, did not change with treatment. As for the villi, the cell migration rate was significantly retarded by 3 cell positions (8%). These results suggest that the cell migration in the villi of weanling pups does not depend directly on the cell proliferation and migration in the intestinal crypt, but is directly affected by the absence of food in the lumen

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As técnicas de espectroscopia por reflexão no infravermelho próximo (NIRRS) e por reflexão difusa no infravermelho médio com transformada de Fourier (DRIFTS) foram empregadas com o método de regressão multivariado por mínimos quadrados parciais (PLS) para a determinação simultânea dos teores de proteína e cinza em amostras de farinha de trigo da variedade Triticum aestivum L. Foram coletados espectros no infravermelho em duplicata de 100 amostras, empregando-se acessórios de reflexão difusa. Os teores de proteína (8,85-13,23%) e cinza (0,330-1,287%), empregados como referência, foram determinados pelo método Kjeldhal e método gravimétrico, respectivamente. Os dados espectrais foram utilizados no formato log(1/R), bem como suas derivadas de primeira e segunda ordem, sendo pré-processados usando-se os dados centrados na média (MC) ou escalados pela variância (VS) ou ambos. Cinqüenta e cinco amostras foram usadas para calibração e 45 para validação dos modelos, adotando-se como critério de construção os valores mínimos do erro padrão de calibração (SEC) e do erro padrão de validação (SEV). Estes valores foram inferiores a 0,33% para proteína e a 0,07% para cinza. Os métodos desenvolvidos apresentam como vantagens a não agressão ao ambiente, bem como permitem uma determinação direta, simultânea, rápida e não destrutiva dos teores de proteína e cinza em amostras de farinha de trigo.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A combinação da espectroscopia no infravermelho próximo (NIR) e calibração multivariada (método dos mínimos quadrados parciais - PLS) para a determinação do teor de proteína total em amostras de café cru, foi investigada. Os teores de proteína total foram inicialmente determinados usando-se como método de referência o de Kjeldhal, e, posteriormente foram construídos modelos de regressão a partir dos espectros na região do infravermelho próximo das amostras de café cru. Foram coletados 159 espectros das amostras de café cru utilizando um acessório de reflectância difusa, na faixa espectral de 4500 a 10000cm-1. Os espectros originais no NIR sofreram diferentes transformações e pré-tratamento matemático, como a transformação Kubelka-Munk; correção multiplicativa de sinal (MSC); alisamento (SPLINE); derivada primeira; média móvel e o pré-tratamento dos dados escalados pela variância. O método analítico proposto possibilitou a determinação direta, sem destruição da amostra, com obtenção de resultados rápidos e sem o consumo de reagentes químicos de forma a preservar o meio ambiente. O método proposto forneceu resultados com boa capacidade de previsão do teor de proteína total, sendo que os erros médios foram inferiores a 6,7%.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A espectroscopia na região do infravermelho próximo (NIR) foi usada para determinar o teor de umidade em amostras de café cru. Foram construídos modelos de regressão usando o método dos mínimos quadrados parciais (PLS) com diferentes pré-tratamentos de dados e 157 espectros NIR coletados de amostras de café usando um acessório de reflectância difusa, na região entre 4500 e 10000 cm-1. Os espectros originais passaram por diferentes transformações e pré-tratamentos matemáticos, como a transformação Kubelka-Munk; a correção multiplicativa de sinal (MSC); o alisamento com SPLINE e a média móvel, e os dados foram escalados pela variância. O modelo de regressão permitiu determinar o teor de umidade nas amostras de café cru com erro quadrático médio de calibração (SEC) de 0,569 g.100 g -1; erro quadrático médio de validação de 0,298 g.100 g -1; coeficiente de correlação (r) 0,712 e 0,818 para calibração e validação, respectivamente; e erro relativo médio de 4,1% para amostras de validação.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este artigo questiona a validade de estimativas de incerteza (dispersão, variância e seus correlatos, como precisão, desvio padrão, etc.) de medição e incerteza de amostragem, bem como sua validade em verificações de conformidade. Obteve tendências de acréscimo ou comportamento em leque em micotoxinas, sódio, óleos graxos e curvas de calibração para carotenoides em ensaios de proficiência, experimentos de precisão de instituições consagradas ou acreditadas e curvas de calibração, o que invalida diversas estimativas de incerteza de medição. Questionou e recalculou resultados do Guia de Incerteza de Amostragem, demonstrando inadequações teóricas e concluiu por sua invalidade. Propôs sistema de estimação voltada para o alimento/processo que se pesquisa através de plano amostral normalizado ou especificamente elaborado para fim de verificação de conformidade. Finalmente, traz as regras decisórias estocásticas para verificação de conformidade em alimentos e diversos outros produtos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Resumo Introdução: Indivíduos com doença renal crônica (DRC) têm grande risco de desenvolver comprometimento cognitivo (CC), inicialmente leve (CCL), passível de identificação, mas ainda subdiagnosticado e subtratado. O Montreal Cognitive Assessment (MoCA) vem sendo indicado para rastreio de CCL na DRC. Objetivo: Avaliar o CCL em indivíduos com DRC pré-dialítica. Métodos: O estudo foi realizado em 72 indivíduos, não idosos, com DRC nos estágios pré-dialíticos. A avaliação neuropsicológica incluiu: o teste de cognição global MoCA; o teste do relógio (TDR); o Digit Span ordem direta (DOD) e inversa (DOI); o teste de fluência verbal (FV), fonêmica (FAS) e semântica (animais); o punho-borda-mão (PBM); e de memória 10 figuras. Resultados: A média de idade dos participantes foi de 56,74 ± 7,63 anos, com predominância de homens (55,6%), com escolaridade ≥ 4 anos (84,3%), a maioria com DRC 1, 2 e 3a e 3b (67,6%), hipertensa (93,1%) e diabética (52,1%). O CC (MoCA ≤ 24) foi observado em 73,6% dos usuários. Não encontramos associação das variáveis demográficas e clínicas com CC, mas tendência de associação com a idade (p = 0,07), com a escolaridade (p = 0,06) e com o DM (0,06). Os testes de função executiva, TDR, DOI e PBM, isoladamente, apresentaram boa sensibilidade e valor preditivo negativo comparados ao MoCA para a identificação de CC e, em conjunto, foram capazes de predizer o resultado do MoCA. Conclusão: O CCL é frequente em usuários não idosos com DRC pré-dialítica. O TDR, DOI e PBM associados são equivalentes ao MoCA na identificação do CC nessa população, sugerindo comprometimento de funções executivas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O desenvolvimento de modelos matemáticos que correlacionem a permissividade elétrica relativa épsilon' e o fator de perda dielétrica épsilon" à quantidade de água presente em amostras de sementes é um passo fundamental no desenvolvimento de medidores em linha do teor de água que possam ser empregados no controle automático de processos como colheita, secagem e aeração. Esse trabalho consistiu na avaliação de três modelos dielétricos para determinação do teor de água de sementes de café, sem a influência do fluxo de massa. Foram utilizadas amostras das variedades Catuaí Amarelo, Catuaí Vermelho e Mundo Novo, com teores de água entre 11 e 23% b.u. e massa específica aparente no intervalo 326 kg m-3 < r < 455 kg m-3. Dos modelos obtidos, apenas aquele que utiliza a medição simultânea de épsilon' e épsilon", a 0,5 e 5,0 MHz, permite estimar o teor de água de sementes de café com o grau de acurácia desejado. Os erros padrão de calibração e predição foram de 1,3 e 1,2 pontos percentuais, respectivamente.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El análisis de la política exterior de EE.UU hacia Colombia en el tema de las drogas ilícitas, revela en qué consiste el prohibicionismo y cuáles han sido sus resultados en Colombia y los países vecinos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We aimed to characterize the HIV-1 epidemic of the Belgian and Colombian cohorts using an integrated approach that includes socio-demographic information, clinical data, and viral sequences, analyzed with statistical and phylogenetic approaches.