605 resultados para bronchus stenosis
Resumo:
BACKGROUND AND PURPOSE: We set out to investigate the predictors and time course for recanalization of spontaneous dissection of the cervical internal carotid artery (SICAD). METHODS: We prospectively included 249 consecutive patients (mean age, 45+/-11 years) with 268 SICAD. Ultrasound examinations were performed at presentation, during the first month, and then at 3, 6, and 12 months, and clinical follow-ups after 3, 6, and 12 months. RESULTS: Of 268 SICADs, 20 (7.5%) presented with
Resumo:
Strictures are a frequent complication of eosinophilic esophagitis. The efficacy and safety of topical corticosteroids and of dilation of eosinophilic esophagitis-associated strictures have not yet been thoroughly clarified. We present a retrospective analysis of 10 adult patients with eosinophilic esophagitis who had symptomatic esophageal stenosis that was unresponsive to topical corticosteroids, and who were treated using bougienage. Eight patients had one single stricture, one patient had two, and another had three strictures; mean stricture length was 2.1 cm (range 1 - 6 cm). Bougienage led to prompt symptom relief. Apart from transient postprocedural odynophagia, no severe complications occurred. During the follow-up (mean 6 months; range 2 - 11 months), all patients enjoyed sustained treatment response.
Resumo:
Objective: Whether or not a protective stoma reduces the rate of anastomotic leakage after distal colorectal anastomosis is still discussed controversially. It does however facilitate clinical management once leakage has occurred. Loop ileostomies seem to be associated with a lower morbidity and a better quality of life compared to loop colostomies. Generally, diverting loop ileostomies are secured at skin level by means of a supporting device in order to prevent retraction of the ileostomy into the abdomen. However, due to the supporting rod, difficulties may occur in applying a stoma bag correctly and leakage of faeces onto the skin may occur even with correct eversion of the afferent limb. Our aim was to compare morbidity and time to self-sufficient stoma-care in patients having a loop ileostomy with rod to those without rod. Methods: A total of 60 patients necessitating loop ileostomy were analyzed. Patients received surgery in of the two involved institutions according to inhouse standard procedures. 30 patients had an ileostomy with rod (VCHK Inselspital) and a further 30 without rod (KSW Winterthur). Morbidity and time to self-sufficiency regarding stoma care was analyzed during the first 90 postoperative days. Morbidity was determined according to a scoring system ranging from 0 to 4 points for any given set of possible complications (bleeding, necrosis, skin irritation, abscess, stenosis, retraction, fistula, prolapse, parastomal hernia, incomplete diversion), where 0 = no complication and 4 = severe complication. Continuous variables were expressed as median (95% Confidence Interval). For comparisons between the groups the Mann-Whitney U test was used, between categorical variables the X2 test was applied. Results: There were no significant differences in length of hospital stay or time to self-sufficient stoma-care between the groups. Although not significant, patients with a rod ileostomy had a tendency towards more stoma-related complications as well as stoma-related reoperations. The number of patients reaching total self-sufficiency regarding stoma care was higher after rodless ileostomy. Conclusion: According to our data, rodless ileostomies seemto fare just as well as those with a supporting rod, with equal morbidity rates and more patients reaching self-sufficient stoma care. Therefore routine application of a rod for diverting loop ileostomy seems unnecessary
Resumo:
PURPOSE: The aim of this retrospective study was to determine optimal duplex sonographic criteria for use in our institution for diagnosing severe carotid stenoses and to correlate those findings with angiographic measurements obtained by the European Carotid Surgery Trial (ECST), North American Symptomatic Carotid Endarterectomy Trial (NASCET), and Common Carotid (CC) methods of grading carotid stenoses. METHODS: We analyzed the angiographic data using the ECST, NASCET, and CC methods and compared the results with the duplex sonographic findings. We then calculated the sensitivity, specificity, positive and negative predictive values, and accuracy of the duplex sonographic method. Taking these parameters into account, the optimal intrastenotic peak systolic velocity (PSV) and end diastolic velocity (EDV) were derived for diagnosing severe stenoses according to the 3 angiographic methods. RESULTS: Optimal PSV and EDV values for diagnosing a 70% or greater stenosis in our laboratory were as follows: with the NASCET method of angiographic grading of stenoses, PSV 220 cm/second or greater and EDV 80 cm/second or greater, and with the ECST and CC methods, PSV 190 cm/second or greater, and EDV 65 cm/second or greater. The optimal PSV and EDV for diagnosing a stenosis of 80% or greater with the ECST grading method were 215 cm/second or greater and 90 cm/second or greater, respectively. CONCLUSIONS: Duplex sonography is a sensitive and accurate tool for evaluating severe carotid stenoses. Optimal PSVs and EDVs vary according to the angiographic method used to grade the stenosis. They are similar for stenoses 70% or greater with the NASCET method and for stenoses 80% or greater with the ECST method.
Resumo:
PURPOSE: To prospectively assess the diagnostic accuracy of nonenhanced three-dimensional (3D) steady-state free precession (SSFP) magnetic resonance (MR) angiography for detection of renal artery stenosis (RAS), with breath-hold contrast material-enhanced MR angiography performed as the reference standard. MATERIALS AND METHODS: The study was local ethics committee approved; all patients gave written informed consent. Fifty-three patients (30 male, 23 female; mean age, 58 years) with arterial hypertension and suspected of having RAS were examined with 1.5-T 3D SSFP renal MR angiography. Stenosis grade, maximal visible vessel length, and subjective image quality were compared. Sensitivity, specificity, accuracy, and negative predictive value (NPV) were calculated on artery-by-artery and patient-by-patient bases. The significance of the results was assessed with the paired two-sided t test for continuous variables and with the marginal homogeneity test for categorical variables. Cohen kappa statistics were used to estimate interobserver agreement. RESULTS: One hundred eight renal arteries with 20 significant (>or=50%) stenoses were detected with contrast-enhanced MR angiography. At artery-by-artery analysis, sensitivity, specificity, accuracy, and NPV of nonenhanced SSFP MR angiography for RAS detection were 100%, 93%, 94%, and 100%, respectively, for observer 1 and 95%, 95%, 95%, and 99%, respectively, for observer 2. Corresponding patient-by-patient values were 100%, 92%, 94%, and 100%, respectively, for observer 1 and 100%, 95%, 96%, and 100%, respectively, for observer 2. Overestimation of stenosis grade with SSFP MR angiography resulted in six and four false-positive findings for readers 1 and 2, respectively. Mean maximal visible lengths of the renal arteries were 69.9 mm at contrast-enhanced MR angiography and 61.1 mm at SSFP MR angiography (P<.001). Both techniques yielded good to excellent image quality. CONCLUSION: Slab-selective inversion-prepared 3D SSFP MR angiography had high sensitivity, specificity, accuracy, and NPV for RAS detection, without the need for contrast material. However, RAS severity was overestimated in some patients.
Resumo:
BACKGROUND: Activation of the complement system and polymorphonuclear neutrophilic leukocytes plays a major role in mediating reperfusion injury after lung transplantation. We hypothesized that early interference with complement activation would reduce lung reperfusion injury after transplantation. METHODS: Unilateral left lung autotransplantation was performed in 6 sheep. After hilar stripping the left lung was flushed with Euro-Collins solution and preserved for 2 hours in situ at 15 degrees C. After reperfusion the right main bronchus and pulmonary artery were occluded, leaving the animal dependent on the reperfused lung (reperfused group). C1-esterase inhibitor group animals (n = 6) received 200 U/kg body weight of C1-esterase inhibitor as a short infusion, half 10 minutes before, the other half 10 minutes after reperfusion. Controls (n = 6) underwent hilar preparation only. Pulmonary function was assessed by alveolar-arterial oxygen difference and pulmonary vascular resistance. The release of beta-N-acetylglucosaminidase served as indicator of polymorphonuclear neutrophilic leukocyte activation. Extravascular lung water was an indicator for pulmonary edema formation. Biopsy specimens were taken from all groups 3 hours after reperfusion for light and electron microscopy. RESULTS: In the reperfused group, alveolar-arterial oxygen difference and pulmonary vascular resistance were significantly elevated after reperfusion. All animals developed frank alveolar edema. The biochemical marker beta-N-acetylglucosaminidase showed significant leukocyte activation. In the C1-esterase inhibitor group, alveolar-arterial oxygen difference, pulmonary vascular resistance, and the level of polymorphonuclear neutrophilic leukocyte activation were significantly lower. CONCLUSIONS: Treatment with C1-esterase inhibitor reduces reperfusion injury and improves pulmonary function in this experimental model.
Resumo:
OBJECTIVE: Reperfusion injury is the main reason for early graft failure after lung transplantation. Inhibition of the adherence of polymorphonuclear leukocytes to activated endothelium by blocking L- and E-selectins (antibody EL-246) could potentially inhibit reperfusion injury. METHODS: Reperfusion injury was induced in a left lung autotransplant model in sheep. After hilar stripping the left lung was flushed with Euro-Collins solution and preserved for 2 h in situ at 15 degrees C. After reperfusion right main bronchus and pulmonary artery were occluded leaving the animal dependent on the reperfused lung (control, n = 6). Pulmonary function was assessed by alveolo-arterial oxygen difference (AaDO2) and pulmonary vascular resistance (PVR), the chemiluminescence of isolated neutrophils, as well as the release of beta-N-acetyl-glucosaminidase (beta-NAG) served as indicator of neutrophilic activation. Extravascular lung water was an indicator for pulmonary edema formation. EL-246 group animals (n = 6) were treated additionally with 1 mg/kg BW of EL-246 given prior and during reperfusion. RESULTS: After 3 h of reperfusion five control animals developed alveolar edema compared to one animal in the EL-246 group (P = 0.08). AaDO2 (mm Hg) was significantly higher in the control compared to the EL-246 group (510 +/- 148 vs. 214 +/- 86). PVR (dyn x s x cm(-5)) was significantly increased in the control compared to the EL-246 group (656 +/- 240 vs. 317 +/- 87). Neutrophilic activation was significantly lower in the EL-246 group. Extravascular lung water was significantly lower compared to control (6.88 +/- 1.0 vs. 13.4 +/- 2.8 g/g blood-free lung weight). CONCLUSIONS: Treatment with EL-246 results in improved pulmonary function and less in vivo PMN activation in this experimental model. Further studies are necessary to evaluate the possible role of selectin blockade in amelioration of reperfusion injury in human lung transplantation.
Resumo:
BACKGROUND AND OBJECTIVE: The standard surgical repair of disease of the aortic valve and the ascending aorta has been combined replacement, which includes the disadvantage of inserting a mechanical valve. We have investigated an individualized approach which preserves the native valve. PATIENTS AND METHODS: Between October 1995 and October 1997, a consecutive total of 101 patients (72 men, 29 women, aged 21-83 years) underwent operations for disease of the ascending aorta: aortic dissection type A in 34 patients, aneurysmal dilatation in 67. Dilatation of the aortic arch was associated with aortic regurgitation in 58 patients. There were 11 patients with aortic valve stenosis or previously implanted aortic valve prosthesis among a total of 46 whose aortic valve was replaced (group II). Supracommissural aortic replacement with a Dacron tube was performed in 16 patients (group I) with normal valve cusps and an aortic root diameter < 3.5 cm. In 28 patients with an aortic root diameter of 3.5-5.0 cm the aortic root was remodelled (group III). Resuspension of the native aortic valve was undertaken in 11 patients with aortic root dilatation of > 5.0 cm (group IV). RESULTS: Operative intervention was electively performed in 72 patients, without any death. Of 29 patients operated as an emergency for acute type A dissection four died (14%). In 55 of the 58 patients with aortic regurgitation in proved possible to preserve native aortic valve (95%). In the early postoperative phase and after an average follow-up time of 11.8 months, transthoracic echocardiography demonstrated good aortic valve function, except in one patient each of groups III and IV who developed aortic regurgitation grades I or II. CONCLUSION: The described individualized approach makes it possible to preserve the native aortic valve in most patients with aortic regurgitation, at a low risk. Follow-up observations so far indicate good results of the reconstruction.
Resumo:
Regular preoperative application of corticosteroids has been considered as a contraindication to lung transplantation for fear of an increased risk of postoperative morbidity and mortality. Recently, however, we have accepted patients for transplantation in whom treatment with steroid medication could not be terminated preoperatively. Up to February 1991, 27 unilateral and bilateral transplantations in 26 patients were analyzed. Corticosteroid therapy was discontinued at least three months prior to transplantation in 13 patients (group 1), whereas in 14 cases, the patients continued their daily corticosteroid therapy to the time of transplantation (prednisolone, 0.1 to 0.3 mg/kg/day; group 2). There were no significant differences between the groups with respect to sex, age, diagnosis, or type of transplantation. One limited bronchial dehiscence occurred; the incidence of postoperative bronchial stenosis was identical in both cohorts; one patient died in each group. In conclusion, no increased morbidity or mortality could be found following lung transplantation with regular preoperative administration of prednisolone up to 0.3 mg/kg/day. Thus, patients who cannot be weaned from their steroid medication but who otherwise are acceptable candidates should not be excluded from lung transplantation.
Resumo:
Replacement of the heart and both lungs or single lung transplantation has been performed in a few cases of terminal (cardio) pulmonary disease in childhood. It remains unclear whether pulmonary allografts will meet the demands of a growing organism. Six domestic pigs (mean body weight, 24 kg) underwent left lung transplantation from donors of equal weight. Immunosuppression consisted of cyclosporine, azathioprine, and corticosteroids. After the pigs doubled their body weight, growth of the lung was assessed by bronchography and pulmonary angiography. In transplant animals it took 11 weeks (normal animals, 6 weeks) for their weight to double. At that time, the bronchial tree showed similar growth when compared with nontransplant animals of equal weight. The diameter of the left lower lobe bronchus (9.2 +/- 0.4 mm) was significantly greater than that of animals of 24 kg body weight (7.5 +/- 0.3 mm; p less than 0.01) but comparable to that of normal pigs of similar weight (9.0 +/- 0.5 mm). The same applied for length of the left lower lobe bronchus (transplants, 95 +/- 6.7 mm; controls 24 kg, 67 +/- 2 mm [p less than 0.01]; controls 48 kg, 93 +/- 3 mm). Similar growth tendencies were observed in the pulmonary vascular tree. The diameter of the left lower lobe artery was 9.4 +/- 98 mm in 48 kg transplant pigs, compared with 9.7 +/- 1.2 mm in 24 kg control pigs and 8.5 +/- 0.8 mm in 48 kg control pigs. In one case of recurrent severe pulmonary rejection, the lung did not grow. We conclude from this study that growth is retarded by immunosuppression.(ABSTRACT TRUNCATED AT 250 WORDS)
Resumo:
Direct revascularization of a bronchial artery has been proposed as a measure to alleviate the problem of bronchial ischemia after lung transplantation. To assess the effect of restoration of arterial blood flow to the transplanted bronchus, bronchial mucosal blood flow was measured in a model of modified unilateral lung transplantation in pigs. Laser Doppler velocimetry (LDV) and radioisotope studies using radio-labeled erythrocytes (RI) were used to measure blood flow at the donor main carina (DC) and upper lobe carina (DUC) after 3 h of reperfusion. The recipient carina was used as a reference point; values obtained by LDV and RI were expressed as percentage of blood flow at the recipient carina. Two groups of animals were studied. In group 1 (n = 6) standard unilateral transplantation was performed; in group 2 (n = 6) a left bronchial artery was reimplanted into the descending thoracic aorta of the recipient. No differences were observed between the two groups with respect to preoperative or postoperative gas exchange or hemodynamics. In group 1, bronchial blood flow at the DC was 37.6 +/- 2.2% (LDV) and 44.1 +/- 14.8% (RI) of reference blood flow. At the DUC, blood flow was 54.9 +/- 7.7% (LDV) and 61.6 +/- 25.7% (RI) of normal flow. In group 2, blood flow was increased at the DC as measured by LDV (55.3 +/- 17.1%; p less than 0.05) and by RI (60.8 +/- 25.3%; p less than 0.2). A similar increase was found at the DUC (LDV: 81.8 +/- 19.3%; p less than 0.05; RI: 88.6 +/- 31.0%; p less than 0.2). It is concluded that there is a significant gradient of blood flow from intra- to extrapulmonary airways after lung transplantation. Reimplantation of a bronchial artery results in significant improvement of graft bronchial blood flow. Restoration of bronchial perfusion to normal levels, however, cannot be achieved, suggesting a possible defect in the microcirculation of the donor airways.
Resumo:
Flash pulmonary edema (FPE) is a general clinical term used to describe a particularly dramatic form of acute decompensated heart failure. Well-established risk factors for heart failure such as hypertension, coronary ischemia, valvular heart disease, and diastolic dysfunction are associated with acute decompensated heart failure as well as with FPE. However, endothelial dysfunction possibly secondary to an excessive activity of renin-angiotensin-aldosterone system, impaired nitric oxide synthesis, increased endothelin levels, and/or excessive circulating catecholamines may cause excessive pulmonary capillary permeability and facilitate FPE formation. Renal artery stenosis particularly when bilateral has been identified has a common cause of FPE. Lack of diurnal variation in blood pressure and a widened pulse pressure have been identified as risk factors for FPE. This review is an attempt to delineate clinical and pathophysiological mechanisms responsible for FPE and to distinguish pathophysiologic, clinical, and therapeutic aspects of FPE from those of acute decompensated heart failure.
Resumo:
AIMS: Lesion length remains a predictor of target lesion revascularisation and results of long lesion stenting remain poor. Sirolimus-eluting stents have been shown to perform better than paclitaxel eluting stents in long lesions. In this substudy of the LEADERS trial, we compared the performance of biolimus biodegradable polymer (BES) and sirolimus permanent polymer stents (SES) in long lesions. METHODS AND RESULTS: A total of 1,707 'all-comer' patients were randomly allocated to treatment with BES and SES. A stratified analysis of angiographic and clinical outcomes at nine months and one year, respectively was performed for vessels with lesion length <20 mm versus >20 mm (as measured by quantitative angiography).Of 1,707 patients, 592 BES patients with 831 lesions and 619 SES patients with 876 lesions had only short lesions treated. One hundred and fifty-three BES patients with 166 lesions and 151 SES patients with 162 lesions had long lesions. There were no significant differences in baseline clinical characteristics, except for higher number of patients with long lesions presenting with acute myocardial infarction in both stent groups. Long lesions tended to have lower MLD and greater percent diameter stenosis at baseline than short lesions. Late loss was greater for long lesions than short lesions. There was no statistically significant difference in late loss between BES and SES stents (0.32+/-0.69 vs 0.24+/-0.57, p=0.59). Binary in-segment restenosis was present in 23.2% versus 13.1% of long lesions treated with BES and SES, respectively (p=0.042). In patients with long lesions, the overall MACE rate was similar for BES and SES (17% vs 14.6%; p=0.62). There was a trend towards higher overall TLR rate with BES (12.4 % vs 6.0%; HR=2.06; p=0.07) and clinically driven TLR (10.5% vs 5.3%: HR 1.94; p=0.13). Rates of definite stent thrombosis were 3.3% in the long lesion group and 1.3-1.7 % in the short lesion group. CONCLUSIONS: BES and SES appear similar with respect to MACE in long lesions in this "all-comer" patient population. However, long lesions tended to have a higher rate of binary in-segment restenosis and TLR following BES than SES treatment.
Resumo:
BACKGROUND: Regression of left ventricular (LV) hypertrophy with normalization of diastolic function has been reported in patients with aortic stenosis late after aortic valve replacement (AVR). The purpose of the present study was to evaluate the effect of AVR on LV function and structure in chronic aortic regurgitation early and late after AVR. METHODS AND RESULTS: Twenty-six patients were included in the present analysis. Eleven patients with severe aortic regurgitation were studied before, early (21 months) and late (89 months) after AVR through the use of LV biplane angiograms, high-fidelity pressure measurements, and LV endomyocardial biopsies. Fifteen healthy subjects were used as controls. LV systolic function was determined from biplane ejection fraction and midwall fractional shortening. LV diastolic function was calculated from the time constant of LV relaxation, peak filling rates, and myocardial stiffness constant. LV structure was assessed from muscle fiber diameter, interstitial fibrosis, and fibrous content. LV muscle mass decreased significantly by 38% early and 55% late after surgery. Ejection fraction was significantly reduced preoperatively and did not change after AVR (P=NS). LV relaxation was significantly prolonged before surgery (89+/-28 ms) but was normalized late after AVR (42+/-14 ms). Early and late peak filling rates were increased preoperatively but normalized postoperatively. Diastolic stiffness constant was increased before surgery (22+/-6 versus 9+/-3 in control subjects; P=0.0003) and remained elevated early and late after AVR (23+/-4; P=0.002). Muscle fiber diameter decreased significantly after AVR but remained increased at late follow-up. Interstitial fibrosis was increased preoperatively and increased even further early but decreased late after AVR. Fibrosis was positively linearly correlated to myocardial stiffness and inversely correlated to LV ejection fraction. CONCLUSIONS: Patients with aortic regurgitation show normalization of macroscopic LV hypertrophy late after AVR, although fiber hypertrophy persists. These changes in LV myocardial structure late after AVR are accompanied by a change in passive elastic properties with persistent diastolic dysfunction.
Resumo:
We compared spot drug-eluting stenting (DES) to full stent coverage for treatment of long coronary stenoses. Consecutive, consenting patients with a long (>20 mm) coronary lesion of nonuniform severity and indication for percutaneous coronary intervention were randomized to full stent coverage of the atherosclerotic lesion with multiple, overlapping stenting (full DES group, n = 90) or spot stenting of hemodynamically significant parts of the lesion only (defined as diameter stenosis >50%; spot DES group, n = 89). At 1-year follow-up, 14 patients with full DES (15.6%) and 5 patients (5.6%) with spot DES had a major adverse cardiac event (MACE; p = 0.031). At 3 years, MACEs occurred in 18 patients with full DES (20%) and 7 patients (7.8%) with spot DES (p = 0.019). Cox proportional hazard model showed that the risk for MACEs was almost 60% lower in patients with spot DES compared to those with full DES (hazard ratio 0.41, 95% confidence interval 0.17 to 0.98, p = 0.044). This association remained even after controlling for age, gender, lesion length, and type of stent used (hazard ratio 0.42, 95% confidence interval 0.17 to 1.00, p = 0.05). In conclusion, total lesion coverage with DES is not necessary in the presence of diffuse disease of nonuniform severity. Selective stenting of only the significantly stenosed parts of the lesion is an appropriate therapeutic alternative in this setting, offering a favorable clinical outcome.