893 resultados para axial loading


Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: In highly emetogenic chemotherapy, the recommended dose of the serotonin-receptor antagonist ondansetron (5 mg/m(2) q8h) may be insufficient to prevent chemotherapy-induced nausea and vomiting. In adults, ondansetron-loading doses (OLD) of 32 mg are safe. We aimed to evaluate in children the safety of an OLD of 16 mg/m(2) (top, 24 mg) i.v., followed by two doses of 5 mg/m(2) q8h. MATERIALS AND METHODS: This retrospective single-center study included all pediatric oncology patients having received >/=1 OLD between 2002 and 2005. Adverse events (AE) definitely, probably, or possibly related to OLD were studied, excluding AE not or unlikely related to the OLD. Associations between potential predictors and at least moderate AE were analyzed by mixed logistic regression. RESULTS: Of 167 patients treated with chemotherapy, 37 (22%) received 543 OLD. The most common AE were hypotension, fatigue, injection site reaction, headache, hot flashes/flushes, and dizziness. At least mild AE were described in 139 OLD (26%), at least moderate AE in 23 (4.2%), and severe AE in 5 (0.9%; exact 95% confidence interval [CI], 0.4-2.1). Life-threatening or lethal AE were not observed (0.0%; 0.0-0.6). At least moderate AE were significantly more frequent in female patients (odds ratio [OR] 3.5; 95% CI 1.4-8.8; p = 0.010), after erroneously given second OLD (17.0; 1.9-154; p = 0.012) and higher 24 h cumulative surface corrected dose (1.26 per mg/m(2); 1.06-1.51; p = 0.009). OLD given to infants below 2 years were not associated with more frequent AE. CONCLUSIONS: Ondansetron-loading doses of 16 mg/m(2) (top, 24 mg) i.v. seem to be safe in infants, children, and adolescents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to establish an MRI classification system for intervertebral disks using axial T2 mapping, with a special focus on evaluating early degenerative intervertebral disks. MATERIALS AND METHODS: Twenty-nine healthy volunteers (19 men, 10 women; age range, 20-44 years; mean age, 31.8 years) were studied, and axial T2 mapping was performed for the L3-L4, L4-L5, and L5-S1 intervertebral disks. Grading was performed using three classification systems for degenerative disks: our system using axial T2 mapping and two other conventional classification systems that focused on the signal intensity of the nucleus pulposus or the structural morphology in sagittal T2-weighted MR images. We analyzed the relationship between T2, which is known to correlate with change in composition of intervertebral disks, and degenerative grade determined using the three classification systems. RESULTS: With axial T2 mapping, differences in T2 between grades I and II were smaller and those between grades II and III, and between grades III and IV, were larger than those with the other grading systems. The ratio of intervertebral disks classified as grade I was higher with the conventional classification systems than that with axial T2 mapping. In contrast, the ratio of intervertebral disks classified as grade II or III was higher with axial T2 mapping than that with the conventional classification systems. CONCLUSION: Axial T2 mapping provides a more T2-based classification. The new system may be able to detect early degenerative changes before the conventional classification systems can.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the diagnostic accuracy of in situ postmortem multislice computed tomography (MSCT) and magnetic resonance imaging (MRI) in the detection of primary traumatic extra-axial hemorrhage. MATERIALS AND METHODS: Thirty forensic neurotrauma cases and 10 nontraumatic controls who underwent both in situ postmortem cranial MSCT and MR imaging before autopsy were retrospectively reviewed. Both imaging modalities were analyzed in view of their accuracy, sensitivity, and specificity concerning the detection of extra-axial hemorrhage. Statistical significance was calculated using the McNemar test. kappa values for interobserver agreement were calculated for extra-axial hemorrhage types and to quantify the agreement between both modalities as well as MRI, CT, and forensics, respectively. RESULTS: Analysis of the detection of hemorrhagic localizations showed an accuracy, sensitivity, and specificity of 89%, 82%, and 92% using CT, and 90%, 83%, and 94% using MRI, respectively. MRI was more sensitive than CT in the detection of subarachnoid hemorrhagic localizations (P = 0.001), whereas no significant difference resulted from the detection of epidural and subdural hemorrhagic findings (P = 0.248 and P = 0.104, respectively). Interobserver agreement for all extra-axial hemorrhage types was substantial (CT kappa = 0.76; MRI kappa = 0.77). The agreement of both modalitites was almost perfect (readers 1 and 2 kappa = 0.88). CONCLUSION: CT and MRI are of comparable potential as forensic diagnostic tools for traumatic extra-axial hemorrhage. Not only of forensic, but also of clinical interest is the observation that most thin blood layers escape the radiological evaluation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Immediate and early loading of dental implants can simplify treatment and increase overall patient satisfaction. The purpose of this 3-year prospective randomized-controlled multicenter study was to assess the differences in survival rates and bone level changes between immediately and early-loaded implants with a new chemically modified surface (SLActive). This investigation shows interim results obtained after 5 months. MATERIAL AND METHODS: Patients > or =18 years of age missing at least one tooth in the posterior maxilla or mandible were enrolled in the study. Following implant placement, patients received a temporary restoration either on the day of surgery (immediate loading) or 28-34 days after surgery (early loading); restorations consisted of single crowns or two to four unit fixed dental prostheses. Permanent restorations were placed 20-23 weeks following surgery. The primary efficacy variable was change in bone level (assessed by standardized radiographs) from baseline to 5 months; secondary variables included implant survival and success rates. RESULTS: A total of 266 patients were enrolled (118 males and 148 females), and a total of 383 implants were placed (197 and 186 in the immediate and early loading groups, respectively). Mean patient age was 46.3+/-12.8 years. After 5 months, implant survival rates were 98% in the immediate group and 97% in the early group. Mean bone level change from baseline was 0.81+/-0.89 mm in the immediate group and 0.56+/-0.73 mm in the early group (P<0.05). Statistical analysis revealed a significant center effect (P<0.0001) and a significant treatment x center interaction (P=0.008). CONCLUSIONS: The results suggested that Straumann implants with an SLActive can be used predictably in time-critical (early or immediate) loading treatment protocols when appropriate patient selection criteria are observed. The mean bone level changes observed from baseline to 5 months (0.56 and 0.81 mm) corresponded to physiological observations from other studies, i.e., were not clinically significant. The presence of a significant center effect and treatment x center interaction indicated that the differences in bone level changes between the two groups were center dependent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The rehabilitation of concrete structures, especially concrete bridge decks, is a major challenge for transportation agencies in the United States. Often, the most appropriate strategy to preserve or rehabilitate these structures is to provide some form of a protective coating or barrier. These surface treatments have typically been some form of polymer, asphalt, or low-permeability concrete, but the application of UHPC has shown promise for this application mainly due to its negligible permeability, but also as a result of its excellent mechanical properties, self-consolidating nature, rapid gain strength, and minimal creep and shrinkage characteristics. However, for widespread acceptance, durability and performance of the composite system must be fully understood, specifically the bond between UHPC and NSC often used in bridge decks. It is essential that the bond offers enough strength to resist the stress due to mechanical loading or thermal effects, while also maintaining an extended service-life performance. This report attempts to assess the bond strength between UHPC and NSC under different loading configurations. Different variables, such as roughness degree of the concrete substrates, age of bond, exposure to freeze-thaw cycles and wetting conditions of the concrete substrate, were included in this study. The combination of splitting tensile test with 0, 300, 600 and 900 freeze-thaw cycles was carried out to assess the bond performance under severe ambient conditions. The slant-shear test was utilized with different interface angles to provide a wide understanding of the bond performance under different combinations of compression and shear stresses. The pull-off test is the most accepted method to evaluate the bond strength in the field. This test which studies the direct tensile strength of the bond, the most severe loading condition, was used to provide data that can be correlated with the other tests that only can be used in the laboratory. The experimental program showed that the bond performance between UHPC and NSC is successful, as the strength regardless the different degree of roughness of the concrete substrate, the age of the composite specimens, the exposure to freeze-thaw cycles and the different loading configurations, is greater than that of concrete substrate and largely satisfies with ACI 546.3R-06.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This Ultra High Performance Concrete research involves observing early-age creep and shrinkage under a compressive load throughout multiple thermal curing regimes. The goal was to mimic the conditions that would be expected of a precast/prestressing plant in the United States, where UHPC beams would be produced quickly to maximize a manufacturing plant’s output. The practice of steam curing green concrete to accelerate compressive strengths for early release of the prestressing tendons was utilized (140°F [60°C], 95% RH, 14 hrs), in addition to the full thermal treatment (195°F [90°C], 95% RH, 48 hrs) while the specimens were under compressive loading. Past experimental studies on creep and shrinkage characteristics of UHPC have only looked at applying a creep load after the thermal treatment had been administered to the specimens, or on ambient cured specimens. However, this research looked at mimicking current U.S. precast/prestressed plant procedures, and thus characterized the creep and shrinkage characteristics of UHPC as it is thermally treated under a compressive load. Michigan Tech has three moveable creep frames to accommodate two loading criteria per frame of 0.2f’ci and 0.6f’ci. Specimens were loaded in the creep frames and moved into a custom built curing chamber at different times, mimicking a precast plant producing several beams throughout the week and applying a thermal cure to all of the beams over the weekend. This thesis presents the effects of creep strain due to the varying curing regimes. An ambient cure regime was used as a baseline for the comparison against the varying thermal curing regimes. In all cases of thermally cured specimens, the compressive creep and shrinkage strains are accelerated to a maximum strain value, and remain consistent after the administration of the thermal cure. An average creep coefficient for specimens subjected to a thermal cure was found to be 1.12 and 0.78 for the high and low load levels, respectively. Precast/pressed plants can expect that simultaneously thermally curing UHPC elements that are produced throughout the week does not impact the post-cure creep coefficient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The aim of the present split-mouth study is to assess the peri-implant conditions around early-loaded sandblasted and acid-etched (SLA) implants, 5 years after abutment connection and to compare, in the same patients, the results obtained with a standard protocol using identical implants with a TPS surface. MATERIAL AND METHODS: Surgical procedure was performed by the same operator and was identical at test (SLA) and control (TPS) sites, in 32 healthy patients. Abutment connection was carried out at 35 N cm 6 weeks postsurgery for test sites and 12 weeks for the controls. Patients were seen regularly, for control and professional cleaning. At 60 months, clinical measures and radiographic bone changes were recorded by the same operator, blind to the type of surface of the implant, on 27 patients, as five patients were lost to follow-up. RESULTS: A total number of 106 implants were examined. No implant was lost. No significant differences were found with respect to the presence of plaque [modified plaque index (mPI) 0.27+/-0.56 vs. 0.32+/-0.54], bleeding on probing (29% vs. 32%), mean pocket depth (3.2+/-1 vs. 3.2+/-1 mm) or mean marginal bone loss (0.32+/-1.04 vs. 0.44+/-1.12 mm) between test and control. Four implants that presented 'spinning' at the time of abutment connection presented no significant differences from the rest of the test sites. CONCLUSION: The results of this prospective study confirm that SLA implants, under defined conditions, are suitable for early loading at 6 weeks in both the mandible and the maxilla. Limited implant spinning, occasionally found at abutment connection, produces no detrimental effect on the clinical outcome when properly handled.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nearly half of the US population faces the risk of developing knee osteoarthritis (OA). Both in vitro and in vivo studies can aid in a better understanding of the etiology, progression, and advancement of this debilitating disorder. The knee menisci are fibrocartilagenous structures that aid in the distribution of load, attenuation of shock, alignment and lubrication of the knee. Little is known about the biochemical and morphological changes associated with knee menisci following altered loading and traumatic impaction, and investigations are needed to further elucidate how degradation of this soft tissue advances over time. The biochemical response of porcine meniscal explants was investigated following a single bout of dynamic compression with and without the treatment of the pharmaceutical drug, anakinra (IL-1RA). Dynamic loading led to a strain-dependent response in both anabolic and catabolic gene expression of meniscal explants. By inhibiting the Interleukin-1 pathway with IL-1RA, a marked decrease in several catabolic molecules was found. From these studies, future developments in OA treatments may be developed. The implementation of an in vivo animal model contributes to the understanding of how the knee joint behaves as a whole. A novel closed-joint in vivo model that induces anterior cruciate ligament (ACL) rupture has been developed to better understand how traumatic injury leads to OA. The menisci of knees from three different groups (healthy, ACL transected, and traumatically impacted) were characterized using histomorphometry. The acute and chronic changes within the knee following traumatic impaction were investigated. The works presented in this dissertation have focused on the characterization, implementation, and development of mechanically-induced changes to the knee menisci.