993 resultados para VARIABLE MASS
Resumo:
OBJECTVE: To objectively and critically assess body mass index and to propose alternatives for relating body weight and height that are evidence-based and that eliminate or reduce the limitations of the body mass index. METHODS: To analyze the relations involving weight and height, we used 2 databases as follows: 1) children and adolescents from Brazil, the United States, and Switzerland; and 2) 538 university students. We performed mathematical simulations with height data ranging from 115 to 190 cm and weight data ranging from 25 to 105 kg. We selected 3 methods to analyze the relation of weight and height as follows: body mass index - weight (kg)/height (m²); reciprocal of the ponderal index - height (cm)/weight1/3 (kg); and ectomorphy. Using the normal range from 20 to 25 kg/m² for the body mass index in the reference height of 170 cm, we identified the corresponding ranges of 41 to 44 cm/kg1/3 for the reciprocal of the ponderal index, and of 1.45 to 3.60 for ectomorphy. RESULTS: The mathematical simulations showed a strong association among the 3 methods with an absolute concordance to a height of 170 cm, but with a tendency towards discrepancy in the normal ranges, which had already been observed for the heights of 165 and 175 cm. This made the direct convertibility between the indices unfeasible. The reciprocal of the ponderal index and ectomorphy with their cut points comprised a larger age range in children and adolescents and a wider and more central range in the university students, both for the reported (current) and desired weights. CONCLUSION: The reciprocal of the ponderal index and ectomorphy are stronger and are more mathematically logical than body mass index; in addition, they may be applied with the same cut points for normal from the age of 5 ½ years on.
Resumo:
Dissertação de mestrado em Bioengenharia
Resumo:
OBJECTIVE: To assess the influence of skeletal muscle mass on ventilatory and hemodynamic variables during exercise in patients with chronic heart failure (CHF). METHODS: Twenty-five male patients underwent maximum cardiopulmonary exercise testing on a treadmill with a ramp protocol and measurement of the skeletal muscle mass of their thighs by using magnetic resonance imaging. The clinically stable, noncachectic patients were assessed and compared with 14 healthy individuals (S) paired by age and body mass index, who underwent the same examinations. RESULTS: Similar values of skeletal muscle mass were found in both groups (CHF group: 3863 ± 874 g; S group: 3743 ± 540 g; p = 0.32). Significant correlations of oxygen consumption in the anaerobic threshold (CHF: r = 0.39; P= 0.02 and S: r = 0.14; P = 0.31) and of oxygen pulse also in the anaerobic threshold (CHF: r = 0.49; P = 0.01 and S: r =0.12; P = 0.36) were found only in the group of patients with chronic heart failure. CONCLUSION: The results obtained indicate that skeletal muscle mass may influence the capacity of patients with CHF to withstand submaximal effort, due to limitations in their physical condition, even maintaining a value similar to that of healthy individuals. This suggests qualitative changes in the musculature.
Resumo:
Membrane reactor, reactive membrane separation, arrheotrope, azeotrope, dusty gas model, esterification, residue curve map, distillation, kinetics, singular point, bifurcation
Resumo:
Inorganic membranes, permeation, diffusion, heat transfer, mass transfer, axial dispersion
Resumo:
Background: Echocardiography, though non-invasive and having relatively low-cost, presents issues of variability which can limit its use in epidemiological studies. Objective: To evaluate left ventricular mass reproducibility when assessed at acquisition (online) compared to when assessed at a reading center after electronic transmission (offline) and also when assessed by different readers at the reading center. Methods: Echocardiographers from the 6 ELSA-Brasil study investigation centers measured the left ventricular mass online during the acquisition from 124 studies before transmitting to the reading center, where studies were read according to the study protocol. Half of these studies were blindly read by a second reader in the reading center. Results: From the 124 echocardiograms, 5 (4%) were considered not measurable. Among the remaining 119, 72 (61%) were women, mean age was 50.2 ± 7.0 years and 2 had structural myocardial abnormalities. Images were considered to be optimal/ good by the reading center for 110 (92.4%) cases. No significant difference existed between online and offline measurements (1,29 g, CI 95% −3.60-6.19), and the intraclass correlation coefficient between them was 0.79 (CI 95% 0.71-0.85). For images read by two readers, the intraclass correlation coefficient was 0.86 (CI 95% 0.78-0.91). Conclusion: There were no significant drifts between online and offline left ventricular mass measurements, and reproducibility was similar to that described in previous studies. Central quantitative assessment of echocardiographic studies in reading centers, as performed in the ELSA-Brasil study, is feasible and useful in clinical and epidemiological studies performed in our setting.
Resumo:
Dieselmotor, Brennverfahren, Ventilsteuerung, Ladungswechsel
Resumo:
Background:Studies show an association between changes in apolipoprotein E (ApoE) and LDLR receptor with the occurrence of dyslipidemia.Objectives:To investigate the association between polymorphisms of the APOE (ε2, ε3, ε4) and LDLR (A370T) genes with the persistence of abnormal serum lipid levels in young individuals followed up for 17 years in the Rio de Janeiro Study.Methods:The study included 56 individuals (35 males) who underwent three assessments at different ages: A1 (mean age 13.30 ± 1.53 years), A2 (22.09 ± 1.91 years) and A3 (31.23 ± 1.99 years). Clinical evaluation with measurement of blood pressure (BP) and body mass index (BMI) was conducted at all three assessments. Measurement of waist circumference (WC) and serum lipids, and analysis of genetic polymorphisms by PCR-RFLP were performed at A2 and A3. Based on dyslipidemia tracking, three groups were established: 0 (no abnormal lipid value at A2 and A3), 1 (up to one abnormal lipid value at A2 or A3) and 2 (one or more abnormal lipid values at A2 and A3).Results:Compared with groups 0 and 1, group 2 presented higher mean values of BP, BMI, WC, LDL-c and TG (p < 0.01) and lower mean values of HDL-c (p = 0.001). Across the assessments, all individuals with APOE genotypes ε2/ε4 and ε4/ε4 maintained at least one abnormal lipid variable, whereas those with genotype ε2/ε3 did not show abnormal values (χ2 = 16.848, p = 0.032). For the LDLR genotypes, there was no significant difference among the groups.Conclusions:APOE gene polymorphisms were associated with dyslipidemia in young individuals followed up longitudinally from childhood.
Resumo:
Magdeburg, Univ., Med. Fak., Diss., 2014
Resumo:
Since the specific heat transfer coefficient (UA) and the volumetric mass transfer coefficient (kLa) play an important role for the design of biotechnological processes, different techniques were developed in the past for the determination of these parameters. However, these approaches often use imprecise dynamic methods for the description of stationary processes and are limited towards scale and geometry of the bioreactor. Therefore, the aim of this thesis was to develop a new method, which overcomes these restrictions. This new approach is based on a permanent production of heat and oxygen by the constant decomposition of hydrogen peroxide in continuous mode. Since the degradation of H2O2 at standard conditions only takes place by the support of a catalyst, different candidates were investigated for their potential (regarding safety issues and reaction kinetic). Manganese-(IV)-oxide was found to be suitable. To compensate the inactivation of MnO2, a continuous process with repeated feeds of fresh MnO2 was established. Subsequently, a scale-up was successfully carried out from 100 mL to a 5 litre glass bioreactor (UniVessel®)To show the applicability of this new method for the characterisation of bioreactors, it was compared with common approaches. With the newly established technique as well as with a conventional procedure, which is based on an electrical heat source, specific heat transfer coefficients were measured in the range of 17.1 – 24.8 W/K for power inputs of about 50 – 70 W/L. However, a first proof of concept regarding the mass transfer showed no constant kLa for different dilution rates up to 0.04 h-1.Based on this, consecutive studies concerning the mass transfer should be made with higher volume flows, due to more even inflow rates. In addition, further experiments are advisable, to analyse the heat transfer in single-use bioreactors and in larger common systems.
Resumo:
v.20:no.27(1937)