983 resultados para URBAN AIR
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização de Vias de Comunicação e Transportes
Resumo:
The goal of this work was the treatment of polluted waste gases in a bubble column reactor (BCR), in order to determinate the maximum value of reactor’s efficiency (RE), varying the inlet concentration (C in) of the pollutants. The gaseous mixtures studied were: (i) air with styrene and (ii) air with styrene and acetone. The liquid phase used to contain the biomass in the reactor was a basal salt medium (BSM), fundamental for the microorganisms’ development. The reactor used in this project consists of a glass column of 620mm height and inside diameter 75mm. In all essays there were continually measured: pH, dissolved oxygen and liquid’s temperature. Temperature and pH were controlled (T=24ºC, 7.0 ≤ pH ≤ 7.7). In all experiments the liquid volume (including the biomass) used in the reactor was kept constant (1.5L) as well as the total gas flowrate (1 L/min). Concerning the goal of the work, some parameters were calculated: the organic load (OL), removal efficiency (RE), elimination capacity (EC), biomass concentration (xf) and dry biomass concentration (Xdw). In a first series of experiments, the gas mixture used was air with styrene, varying its concentration from 191 mg.m-3 to 6500 mg.m-3.It was concluded that the RE maximum value (97%) was obtained for C in Sty = 4200 mg.m-3. For the maximum tested value of C in Sty, RE obtained was 20%. In a second step, the gaseous mixture included acetone, varying C in Sty between 225 mg.m-3 and 2659 mg.m-3 and C in Ac between 153mg.m-3 and 1389 mg.m-3. The aim of these tests was the determination of C in Ac for which RE was maximum, obtaining C in Ac = 750 mg.m-3. A third series of experiments was performed, in which C in Ac was maintained equal to that value and C in Sty was varied until higher values (5422 mg.m-3). RE maximum values obtained in this last series were 100% for styrene and 40% for acetone. One important conclusion is the fact that the microorganisms available degrade better styrene than acetone. On the ambit of this study, it was possible to identify the species available in biomass: Xanthobacter antotrophicus py2, Enterobacter aerogenes, Nocardia, Corynebacterium Spp., Rhodococcus rhodochrous e Pseudomonas Sp.
Resumo:
The evaluation of benzene in different environments such as indoor (with and without tobacco smoke), a city area, countryside, gas stations and near exhaust pipes from cars running on different types of fuels was performed. The samples were analyzed using gas chromatography (GC) with flame ionization detection (FID) and tandem mass spectrometric detection (MS/MS) (to confirm the identification of benzene in the air samples). Operating conditions for the GC-MS analysis were optimized as well as the sampling and sample preparation. The results obtained in this work indicate that i) the type of fuel directly influences the benzene concentration in the air. Gasoline with additives provided the highest amount of benzene followed by unleaded gasoline and diesel; ii) the benzene concentration in the gas station was always higher than the advisable limit established by law (5 μg m−3) and during the unloading of gasoline the achieved concentration was 8371 μg m−3; iii) the data from the countryside (Taliscas) and the urban city (Matosinhos) were below 5 μg m−3 except 5 days after a fire on a petroleum refinery plant located near the city; iv) it was proven that in coffee shops where smoking is allowed the benzene concentration is higher (6 μg m−3) than in coffee shops where this is forbidden (4 μg m−3). This method may also be helpful for environmental analytical chemists who use GC-MS/MS for the confirmation or/and quantification of benzene.
Resumo:
Abstract This work reports the analysis of the efficiency and time of soil remediation using vapour extraction as well as provides comparison of results using both, prepared and real soils. The main objectives were: (i) to analyse the efficiency and time of remediation according to the water and natural organic matter content of the soil; and (ii) to assess if a previous study, performed using prepared soils, could help to preview the process viability in real conditions. For sandy soils with negligible clay content, artificially contaminated with cyclohexane before vapour extraction, it was concluded that (i) the increase of soil water content and mainly of natural organic matter content influenced negatively the remediation process, making it less efficient, more time consuming, and consequently more expensive; and (ii) a previous study using prepared soils of similar characteristics has proven helpful for previewing the process viability in real conditions.
Resumo:
The impact of effluent wastewaters from four different hospitals: a university (1456 beds), a general (350 beds), a pediatric (110 beds) and a maternity hospital (96 beds), which are conveyed to the same wastewater treatment plant (WWTP), was evaluated in the receiving urban wastewaters. The occurrence of 78 pharmaceuticals belonging to several therapeutic classes was assessed in hospital effluents and WWTP wastewaters (influent and effluent) as well as the contribution of each hospital in WWTP influent in terms of pharmaceutical load. Results indicate that pharmaceuticals are widespread pollutants in both hospital and urban wastewaters. The contribution of hospitals to the input of pharmaceuticals in urban wastewaters widely varies, according to their dimension. The estimated total mass loadings were 306 g d− 1 for the university hospital, 155 g d− 1 for the general one, 14 g d− 1 for the pediatric hospital and 1.5 g d− 1 for the maternity hospital, showing that the biggest hospitals have a greater contribution to the total mass load of pharmaceuticals. Furthermore, analysis of individual contributions of each therapeutic group showed that NSAIDs, analgesics and antibiotics are among the groups with the highest inputs. Removal efficiency can go from over 90% for pharmaceuticals like acetaminophen and ibuprofen to not removal for β-blockers and salbutamol. Total mass load of pharmaceuticals into receiving surface waters was estimated between 5 and 14 g/d/1000 inhabitants. Finally, the environmental risk posed by pharmaceuticals detected in hospital and WWTP effluents was assessed by means of hazard quotients toward different trophic levels (algae, daphnids and fish). Several pharmaceuticals present in the different matrices were identified as potentially hazardous to aquatic organisms, showing that especial attention should be paid to antibiotics such as ciprofloxacin, ofloxacin, sulfamethoxazole, azithromycin and clarithromycin, since their hazard quotients in WWTP effluent revealed that they could pose an ecotoxicological risk to algae.
Resumo:
Polyaromatic hydrocarbon (PAH) sorption to soil is a key process deciding the transport and fate of PAH, and potential toxic impacts in the soil and groundwater ecosystems, for example in connection with atmospheric PAH deposition on soils. There are numerous studies on PAH sorption in relatively low organic porous media such as urban soils and groundwater sediments, but less attention has been given to cultivated soils. In this study, the phenanthrene partition coefficient, KD (liter per kilogram), was measured on 143 cultivated Danish soils (115 topsoils, 0–0.25-m soil depth and 28 subsoils, 0.25–1-m depth) by the single-point adsorption method. The organic carbon partition coefficient, KOC (liter per kilogram) for topsoils was found generally to fall between the KOC values estimated by the two most frequently used models for PAH partitioning, the Abdul et al. (Hazardous Waste & Hazardous Materials 4(3):211– 222, 1987) model and Karickhoff et al. (Water Research 13:241–248, 1979) model. A less-recognized model by Karickhoff (Chemosphere 10:833–846, 1981), yielding a KOC of 14,918 Lkg−1, closely corresponded to the average measured KOC value for the topsoils, and this model is therefore recommended for prediction of phenanthrene mobility in cultivated topsoils. For lower subsoils (0.25–1-m depth), the KOC values were closer to and mostly below the estimate by the Abdul et al. (Hazardous Waste & Hazardous Materials 4(3):211–222, 1987) model. This implies a different organic matter composition and higher PAH sorption strength in cultivated topsoils, likely due to management effects including more rapid carbon turnover. Finally, we applied the recent Dexter et al. (Geoderma 144:620–627, 2008) theorem, and calculated the complexed organic carbon and non-complexed organic carbon fractions (COC and NCOC, grams per gram). Multiple regression analyses showed that the NCOC-based phenanthrene partition coefficient (KNCOC) could be markedly higher than the COCbased partition coefficient (KCOC) for soils with a clay/OC ratio <10. This possibly higher PAH sorption affinity to the NCOC fraction needs further investigations to develop more realistic and accurate models for PAH mobility and effects in the environment, also with regard to colloid-facilitated PAH transport.
Resumo:
Every year European citizens become victims of devastating fires, which are especially disastrous for Southern European countries. Apart from the numerous health and economic consequences, fires generate hazardous pollutants that are introduced into the environment, thus representing serious risks for public health. In that regard, particulate matter (PM) is of amajor concern. Thus, the objectives of thisworkwere to characterize the trend of forest fire occurrences and burnt area during the period of 2005 and 2010 and to study the influence of forest fires on levels of particulatematter PM10 and PM2.5. In 2010, 22,026 forest fires occurred in Portugal. The northern region was the most affected by forest fires, with 27% of occurrences in Oporto district. The annual means of PM10 and PM2.5 concentrations at two urban background sites were 25±14 μg m−3 and 8.2±4.9 μg m−3, and 17±13 μg m−3 and 7.3±5.9 μg m−3, respectively. At both sites the highest levels of PMfractionswere observed during July and August of 2010, corresponding to the periods when majority (66%) of forest fires occurred. Furthermore, PM10 daily limit at the two sites was exceeded during 20 and 5 days, respectively; 56%, and respectively 60% of those exceedances occurred during the forest fire season. Considering that the risks of forest fire ignition and severity are enhanced with elevated temperatures, the climate change might increase the environmental impacts of forest fires.
Resumo:
Atmospheric pollution by motor vehicles is considered a relevant source of damage to architectural heritage. Thus the aim of this work was to assess the atmospheric depositions and patterns of polycyclic aromatic hydrocarbons (PAHs) in façades of historical monuments. Eighteen PAHs (16 PAHs considered by US EPA as priority pollutants, dibenzo[a,l]pyrene and benzo[j]fluoranthene) were determined in thin black layers collected from façades of two historical monuments: Hospital Santo António and Lapa Church (Oporto, Portugal). Scanning electron microscopy (SEM) was used for morphological and elemental characterisation of thin black layers; PAHs were quantified by microwave-assisted extraction combined with liquid chromatography (MAE-LC). The thickness of thin black layers were 80–110 μm and they contained significant levels of iron, sulfur, calcium and phosphorus. Total concentrations of 18 PAHs ranged from 7.74 to 147.92 ng/g (mean of 45.52 ng/g) in thin black layers of Hospital Santo António, giving a range three times lower than at Lapa Church (5.44– 429.26 ng/g; mean of 110.25 ng/g); four to six rings compounds accounted at both monuments approximately for 80–85% of ΣPAHs. The diagnostic ratios showed that traffic emissions were significant source of PAHs in thin black layers. Composition profiles of PAHs in thin black layers of both monuments were similar to those of ambient air, thus showing that air pollution has a significant impact on the conditions and stone decay of historical building façades. The obtained results confirm that historical monuments in urban areas act as passive repositories for air pollutants present in the surrounding atmosphere.
Resumo:
The relation between the information/knowledge expression and the physical expression can be involved as one of items for an ambient intelligent computing [2],[3]. Moreover, because there are so many contexts around user/spaces during a user movement, all appplcation which are using AmI for users are based on the relation between user devices and environments. In these situations, it is possible that the AmI may output the wrong result from unreliable contexts by attackers. Recently, establishing a server have been utilizes, so finding secure contexts and make contexts of higher security level for save communication have been given importance. Attackers try to put their devices on the expected path of all users in order to obtain users informationillegally or they may try to broadcast their SPAMS to users. This paper is an extensionof [11] which studies the Security Grade Assignment Model (SGAM) to set Cyber-Society Organization (CSO).
Resumo:
OBJECTIVE: To evaluate density, parity rates, daily survival and longevity of natural populations of Culex quinquefasciatus in three neighborhoods with distinct socio-economic and infrastructure profiles. METHODS: Mosquito collections of the Culex quinquefasciatus species were performed weekly during two four month periods, from August to November 2008 (spring) and March to June 2009 (fall), in a favela (slum), a suburban area and a middle class area of Rio de Janeiro, Southeastern Brazil. Collections were performed with backpack aspirators, in 20 randomly selected houses in each area per week, during 15-20 minutes per house. Ovaries were removed from captured females and classified as initial, intermediary or final stage. Furthermore, females were dissected for determination of parity based on the condition of the tracheal system. Mosquito survival rate and longevity were estimated on a per month basis for each neighborhood. RESULTS: We collected a total of 2,062 Culex quinquefasciatus, but monthly vector density was not correlated with temperature and rainfall. We dissected the ovaries of 625 Culex quinquefasciatus, and overall, there was a higher proportion of nulliparous females during the dryer months, while gravid females were more frequent in rainy months. In the middle class neighborhood, the parity rate reached up to 93.75% with survivorship of 0.979. Lower parity and survival rates were obtained in the suburban area (as low as 36.4% parity and 0.711 daily survival). Up to 84.7% of Culex quinquefasciatus females could survive the eight day period needed to complete West Nile Virus incubation. CONCLUSIONS: The survival rate of Culex quinquefasciatus varied significantly between the neighborhoods. This suggests that vectorial capacity and disease transmission risk may vary greatly between different urban areas, which is potentially useful information for vector control programs.
Resumo:
OBJECTIVE: To identify the prevalence of hearing loss for the population in the urban area. METHODS: A cross-sectional household survey based on the World Health Organization Ear and Hearing Disorders Survey Protocol was conducted in 298 households in the urban area of Monte Negro, Rondonia, Northern Brazil, from 2005 to 2007. Ear examinations, behavioral audiometry and pure tone audiometry were conducted on 577 individuals. RESULTS: The results showed that 3.8% (95%CI 2.17;5.45) of population were classified in the disabling hearing impairment category. The prevalence of moderate hearing impairment was 3.4%; severe impairment was 0.4%; and profound hearing impairment was not found. CONCLUSIONS: The impairing hearing loss prevalence found in this study is within of the international prevalence for this level of hearing loss and smaller than observed in a previous study in the South region of Brazil.
Resumo:
OBJECTIVE To analyze the association between concentrations of air pollutants and admissions for respiratory causes in children. METHODS Ecological time series study. Daily figures for hospital admissions of children aged < 6, and daily concentrations of air pollutants (PM10, SO2, NO2, O3 and CO) were analyzed in the Região da Grande Vitória, ES, Southeastern Brazil, from January 2005 to December 2010. For statistical analysis, two techniques were combined: Poisson regression with generalized additive models and principal model component analysis. Those analysis techniques complemented each other and provided more significant estimates in the estimation of relative risk. The models were adjusted for temporal trend, seasonality, day of the week, meteorological factors and autocorrelation. In the final adjustment of the model, it was necessary to include models of the Autoregressive Moving Average Models (p, q) type in the residuals in order to eliminate the autocorrelation structures present in the components. RESULTS For every 10:49 μg/m3 increase (interquartile range) in levels of the pollutant PM10 there was a 3.0% increase in the relative risk estimated using the generalized additive model analysis of main components-seasonal autoregressive – while in the usual generalized additive model, the estimate was 2.0%. CONCLUSIONS Compared to the usual generalized additive model, in general, the proposed aspect of generalized additive model − principal component analysis, showed better results in estimating relative risk and quality of fit.
Resumo:
This paper presents the recent research results about the development of a Observed Time Difference (OTD) based geolocation algorithm based on network trace data, for a real Universal Mobile Telecommunication System (UMTS) Network. The initial results have been published in [1], the current paper focus on increasing the sample convergence rate, and introducing a new filtering approach based on a moving average spatial filter, to increase accuracy. Field tests have been carried out for two radio environments (urban and suburban) in the Lisbon area, Portugal. The new enhancements produced a geopositioning success rate of 47% and 31%, and a median accuracy of 151 m and 337 m, for the urban and suburban environments, respectively. The implemented filter produced a 16% and 20% increase on accuracy, when compared with the geopositioned raw data. The obtained results are rather promising in accuracy and geolocation success rate. OTD positioning smoothed by moving average spatial filtering reveals a strong approach for positioning trace extracted events, vital for boosting Self-Organizing Networks (SON) over a 3G network.
Resumo:
According to numerous studies, airborne nanoparticles have a potential to produce serious adverse human health effects when deposited into the respiratory tract. The most important parts of the lung are the alveolar regions with their enormous surface areas and potential to transfer nanoparticles into the blood stream. These effects may be potentiated in case of the elderly, since this population is more susceptible to air pollutants in general and more to nanoparticles than larger particles. The main goal of this investigation was to determine the exposure of institutionalized elders to nanoparticles using Nanoparticle Surface Area Monitor (NSAM) equipment to calculate the deposited surface area (DSA) of nanoparticles into elderly lungs. In total, 193 institutionalized individuals over 65 yr of age were examined in four elderly care centers (ECC). The occupancy daily pattern was achieved by applying a questionnaire, and it was concluded that these subjects spent most of their time indoors, including the bedroom and living room, the indoor microenvironments with higher prevalence of elderly occupancy. The deposited surface area ranged from 10 to 46 mu m(2)/cm(3). The living rooms presented significantly higher levels compared with bedrooms. Comparing PM10 concentrations with nanoparticles deposited surface area in elderly lungs, it is conceivable that living rooms presented the highest concentration of PM10 and were similar to the highest average DSA. The temporal distribution of DSA was also assessed. While data showed a quantitative fluctuation in values in bedrooms, high peaks were detected in living rooms.