927 resultados para Tube-in-tube-reactor


Relevância:

50.00% 50.00%

Publicador:

Resumo:

This paper presents an analysis of the transport of electric current in a jet of an electrically conducting liquid discharging from a metallic tube into a gas or a vacuum, and subject to an electric field due to a high voltage applied between the tube and a far electrode. The flow, the surface charge and the electric field are computed in the current transfer region of the jet, where conduction current in the liquid becomes surface current due to the convection of electric charge accumulated at its surface. The electric current computed as a function of the flow rate of the liquid injected through the tube increases first as the square root of this flow rate, levels to a nearly constant value when the flow rate is increased and finally sets to a linear increase when the flow rate is further increased. The current increases linearly with the applied voltage at small and moderate values of this variable, and faster than linearly at high voltages. The characteristic length and structure of the current transfer region are determined. Order-of-magnitude estimates for jets which are only weakly stretched by the electric stresses are worked out that qualitatively account for some of the numerical results.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

El accidente de rotura de tubos de un generador de vapor (Steam Generator Tube Rupture, SGTR) en los reactores de agua a presión es uno de los transitorios más exigentes desde el punto de vista de operación. Los transitorios de SGTR son especiales, ya que podría dar lugar a emisiones radiológicas al exterior sin necesidad de daño en el núcleo previo o sin que falle la contención, ya que los SG pueden constituir una vía directa desde el reactor al medio ambiente en este transitorio. En los análisis de seguridad, el SGTR se analiza desde un punto determinista y probabilista, con distintos enfoques con respecto a las acciones del operador y las consecuencias analizadas. Cuando comenzaron los Análisis Deterministas de Seguridad (DSA), la forma de analizar el SGTR fue sin dar crédito a la acción del operador durante los primeros 30 min del transitorio, lo que suponía que el grupo de operación era capaz de detener la fuga por el tubo roto dentro de ese tiempo. Sin embargo, los diferentes casos reales de accidentes de SGTR sucedidos en los EE.UU. y alrededor del mundo demostraron que los operadores pueden emplear más de 30 minutos para detener la fuga en la vida real. Algunas metodologías fueron desarrolladas en los EEUU y en Europa para abordar esa cuestión. En el Análisis Probabilista de Seguridad (PSA), las acciones del operador se tienen en cuenta para diseñar los cabeceros en el árbol de sucesos. Los tiempos disponibles se utilizan para establecer los criterios de éxito para dichos cabeceros. Sin embargo, en una secuencia dinámica como el SGTR, las acciones de un operador son muy dependientes del tiempo disponible por las acciones humanas anteriores. Además, algunas de las secuencias de SGTR puede conducir a la liberación de actividad radiológica al exterior sin daño previo en el núcleo y que no se tienen en cuenta en el APS, ya que desde el punto de vista de la integridad de núcleo son de éxito. Para ello, para analizar todos estos factores, la forma adecuada de analizar este tipo de secuencias pueden ser a través de una metodología que contemple Árboles de Sucesos Dinámicos (Dynamic Event Trees, DET). En esta Tesis Doctoral se compara el impacto en la evolución temporal y la dosis al exterior de la hipótesis más relevantes encontradas en los Análisis Deterministas a nivel mundial. La comparación se realiza con un modelo PWR Westinghouse de tres lazos (CN Almaraz) con el código termohidráulico TRACE, con hipótesis de estimación óptima, pero con hipótesis deterministas como criterio de fallo único o pérdida de energía eléctrica exterior. Las dosis al exterior se calculan con RADTRAD, ya que es uno de los códigos utilizados normalmente para los cálculos de dosis del SGTR. El comportamiento del reactor y las dosis al exterior son muy diversas, según las diferentes hipótesis en cada metodología. Por otra parte, los resultados están bastante lejos de los límites de regulación, pese a los conservadurismos introducidos. En el siguiente paso de la Tesis Doctoral, se ha realizado un análisis de seguridad integrado del SGTR según la metodología ISA, desarrollada por el Consejo de Seguridad Nuclear español (CSN). Para ello, se ha realizado un análisis termo-hidráulico con un modelo de PWR Westinghouse de 3 lazos con el código MAAP. La metodología ISA permite la obtención del árbol de eventos dinámico del SGTR, teniendo en cuenta las incertidumbres en los tiempos de actuación del operador. Las simulaciones se realizaron con SCAIS (sistema de simulación de códigos para la evaluación de la seguridad integrada), que incluye un acoplamiento dinámico con MAAP. Las dosis al exterior se calcularon también con RADTRAD. En los resultados, se han tenido en cuenta, por primera vez en la literatura, las consecuencias de las secuencias en términos no sólo de daños en el núcleo sino de dosis al exterior. Esta tesis doctoral demuestra la necesidad de analizar todas las consecuencias que contribuyen al riesgo en un accidente como el SGTR. Para ello se ha hecho uso de una metodología integrada como ISA-CSN. Con este enfoque, la visión del DSA del SGTR (consecuencias radiológicas) se une con la visión del PSA del SGTR (consecuencias de daño al núcleo) para evaluar el riesgo total del accidente. Abstract Steam Generator Tube Rupture accidents in Pressurized Water Reactors are known to be one of the most demanding transients for the operating crew. SGTR are special transient as they could lead to radiological releases without core damage or containment failure, as they can constitute a direct path to the environment. The SGTR is analyzed from a Deterministic and Probabilistic point of view in the Safety Analysis, although the assumptions of the different approaches regarding the operator actions are quite different. In the beginning of Deterministic Safety Analysis, the way of analyzing the SGTR was not crediting the operator action for the first 30 min of the transient, assuming that the operating crew was able to stop the primary to secondary leakage within that time. However, the different real SGTR accident cases happened in the USA and over the world demonstrated that operators can took more than 30 min to stop the leakage in actual sequences. Some methodologies were raised in the USA and in Europe to cover that issue. In the Probabilistic Safety Analysis, the operator actions are taken into account to set the headers in the event tree. The available times are used to establish the success criteria for the headers. However, in such a dynamic sequence as SGTR, the operator actions are very dependent on the time available left by the other human actions. Moreover, some of the SGTR sequences can lead to offsite doses without previous core damage and they are not taken into account in PSA as from the point of view of core integrity are successful. Therefore, to analyze all this factors, the appropriate way of analyzing that kind of sequences could be through a Dynamic Event Tree methodology. This Thesis compares the impact on transient evolution and the offsite dose of the most relevant hypothesis of the different SGTR analysis included in the Deterministic Safety Analysis. The comparison is done with a PWR Westinghouse three loop model in TRACE code (Almaraz NPP), with best estimate assumptions but including deterministic hypothesis such as single failure criteria or loss of offsite power. The offsite doses are calculated with RADTRAD code, as it is one of the codes normally used for SGTR offsite dose calculations. The behaviour of the reactor and the offsite doses are quite diverse depending on the different assumptions made in each methodology. On the other hand, although the high conservatism, such as the single failure criteria, the results are quite far from the regulatory limits. In the next stage of the Thesis, the Integrated Safety Assessment (ISA) methodology, developed by the Spanish Nuclear Safety Council (CSN), has been applied to a thermohydraulical analysis of a Westinghouse 3-loop PWR plant with the MAAP code. The ISA methodology allows obtaining the SGTR Dynamic Event Tree taking into account the uncertainties on the operator actuation times. Simulations are performed with SCAIS (Simulation Code system for Integrated Safety Assessment), which includes a dynamic coupling with MAAP thermal hydraulic code. The offsite doses are calculated also with RADTRAD. The results shows the consequences of the sequences in terms not only of core damage but of offsite doses. This Thesis shows the need of analyzing all the consequences in an accident such as SGTR. For that, an it has been used an integral methodology like ISA-CSN. With this approach, the DSA vision of the SGTR (radiological consequences) is joined with the PSA vision of the SGTR (core damage consequences) to measure the total risk of the accident.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Steam Generator Tube Rupture (SGTR) sequences in Pressurized Water Reactors are known to be one of the most demanding transients for the operating crew. SGTR are a special kind of transient as they could lead to radiological releases without core damage or containment failure, as they can constitute a direct path from the reactor coolant system to the environment. The first methodology used to perform the Deterministic Safety Analysis (DSA) of a SGTR did not credit the operator action for the first 30 min of the transient, assuming that the operating crew was able to stop the primary to secondary leakage within that period of time. However, the different real SGTR accident cases happened in the USA and over the world demonstrated that the operators usually take more than 30 min to stop the leakage in actual sequences. Some methodologies were raised to overcome that fact, considering operator actions from the beginning of the transient, as it is done in Probabilistic Safety Analysis. This paper presents the results of comparing different assumptions regarding the single failure criteria and the operator action taken from the most common methodologies included in the different Deterministic Safety Analysis. One single failure criteria that has not been analysed previously in the literature is proposed and analysed in this paper too. The comparison is done with a PWR Westinghouse three loop model in TRACE code (Almaraz NPP) with best estimate assumptions but including deterministic hypothesis such as single failure criteria or loss of offsite power. The behaviour of the reactor is quite diverse depending on the different assumptions made regarding the operator actions. On the other hand, although there are high conservatisms included in the hypothesis, as the single failure criteria, all the results are quite far from the regulatory limits. In addition, some improvements to the Emergency Operating Procedures to minimize the offsite release from the damaged SG in case of a SGTR are outlined taking into account the offsite dose sensitivity results.