869 resultados para Tomografia poço-a-poço


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ichthyofaunistic studies aims to broad the knowledge of composition, abundance and distribution of species in certain areas, and when possible, to infer patterns of distribution, as well as extrinsic factors that affect these patterns in space and time. The Paranapanema River suffers the impact of the construction of hydroelectric power plants in cascade system along its main channel, changing the characteristics of lotic to lentic and semi-lentic. These changes affect the entire biocenosis and the surroundings of the reservoir and, in particular, the fish fauna. In this context, the aim of this study was to characterize the fish assemblage in two lakes and stretches of the main channel, located near the outfall of the Paranapanema River, Jurumirim reservoir area, comparing them to their composition and structure, using ecological indices as tools. Fish were caught every three months from April 2011 to January 2013, using gill nets of various mesh openings in four stretches: Environment 1 - Calha Sete Ilhas, Environment 2 - Calha Poço da Pedra, Environment 3 - Lagoa Sete Ilhas and Environment 4 - Lagoa Poço de Pedra. After the capture, the specimens were identified and biometric analysis was performed (total and standard length weight). We captured 4,006 individuals belonging to four orders and 34 species, 31 native species and three non-native species. In abundance (n) and number of species (S), there was a predominance of Characiformes (57 %) followed by Siluriformes (31%). Overall, most of the species was constant concerning the frequency of capture. The five most representative species in abundance were Schizodon intermedius, Cyphocarax modestus, Pimelodus maculatus, Hoplosternum littorale and Serrasalmus maculatus, contributing with 60% of total individuals captured. Regarding the stretches, these species present diversity (H'), evenness (E), dominance (D) and richness (d) of similar species, since the abundance was higher in ...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work focuses on a study on the fatigue behavior of a microalloyed steel API 5L X70, used in pipes lines to transport oil and gas. These types of steels have excellent mechanical resistance values and ductility and therefore increased their study driven by increased demand for oil and especially natural gas, which consequently raises the need to build new pipelines to transport these products. The oil extraction units, composed of the risers (pipelines connecting the oil well to the ship), are dimensioned to remain installed for periods of 20 to 30 years in the marine environment, a hostile environment for high pressure, corrosion, low temperatures and the stresses caused by the movement of water and tides. For analysis, the S-N (stress versus number of cycles) curves were obtained from data collected from bodies-of-proof cylindrical longitudinal, transverse and that one removed from the weld area of the pipe, tested in accordance with ASTM E466. Tensile tests were performed for characterizing the mechanical properties of the samples and welded joints, concluded that the values meet the specifications of the standard API 5L. To characterize microstructural material, also metallographic analysis was made of regions of the base metal and the HAZ. The results of fatigue tests demonstrated a higher life for the specimens removed from the longitudinal direction the pipe, followed by those in the transverse direction and, finally, the welded joint. The origins of the fatigue cracks were determined by scanning electron microscopy (SEM)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ability to tridimensionally evaluate pathological and anatomical areas, in apical surgery planning, presents a number of advantages. Cone beam computed tomography (CBCT) was developed for dental applications. This paper aims to present a literature review on CBCT, highlighting its advantages over both conventional computed tomography (CT) and radiography. Moreover, its clinical applications in apical surgery are discussed. LITERATURE REVIEW AND CONCLUSION: Unlikely CT, CBCT captures a volume of data in a single 360º rotation, providing benefits such as higher accuracy, better resolution, reduced scanning time and reduced radiation dose. In the maxillofacial region, CBCT has been mainly used in the assessment of dento-alveolar pathology and oral traumatology. CBCT provides a better diagnosis and quantitative information on periodontal bone levels than conventional radiography. It has also been used for patients requiring surgical facial reconstruction, orthognathic surgery, dental implants, and more complex tooth extractions. Besides that, it seems to be a significant tool in modern endodontic practice, presenting useful applications in apical surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Cirurgia Veterinária - FCAV

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work aimed to evaluate some aspects of construction and operation of full-scale best management practices and their effects on infiltration loading rate. Two systems were studied: i) filter-swale-trench (FST) and ii) infiltration well (IW). In these units, field essays and full-scale measurements were made in order to assess the soil permeability. Further, the fine particles transportation and the geotextile blanket permeability were determined before and after operation. The results pointed out that there were soil transportation to inside the FST and IW systems, despite of the installed protections, and that these material were responsible for diminishing the geotextile (reduction from 30 to 90% for FST and 40 to 70% for IW) and the full-scale infiltration loading rates (varying from 4,7 x 10-6 to 10-5 m.s-1).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Microbiologia Agropecuária - FCAV

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mouthwashes are used as an adjunct to tooth brushing for improving breath and preventing oral diseases. The aim of this study was to compare the in vitro Maximum Inhibitory Dilution (MID) of 3 mouthwashes with different active ingredients against mutans streptococci (MS). The products analyzed were PeriogardR, CepacolR and PlaxR Fresh Mint. Their antibacterial activity was assessed in duplicate in 96-well microtiter plates against 36 clinical isolates of MS. Each mouthwash was submitted to a serial two-fold dilution (1/2.5 to 1/5120) using double concentration of Tryptose Soy Broth with 1.0% yeast extract. The final volume in each well was 100 mL plus 5 mL of a bacterial suspension, equivalent to 107 CFU/mL. They were incubated microaerobically at 37oC for 48 hours and the MIDs determined. MID was 1/320 for PeriogardR and CepacolR, and 1/20 for PlaxR. Statistical analysis revealed that the MID of PeriogardR MID did not differ from that of CepacolR (p>0.05), and was higher than that of PlaxR (p<0.05). In conclusion, the antiseptic mouthwashes containing chlorhexidine (PeriogardR) and cetylpyridinium chloride (CepacolR) had higher in vitroantibacterial activity (MID) against MS than the antiseptic mouthwash containing triclosan (PlaxR), according to microbiological method employed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present work was to study the control of the dynamics of diatomic heteronuclear molecules interacting with electric fields created by lasers. Specifically in this work, the molecular photoassociation phenomenon will be analyzed. At this phenomenon, the atom's relative movement is described by a particle that moves in a morse potential well under the influence of an external time dependant force related to the external field. Based on the optimum control theory (OCT), it is presented at the present work laser pulses that alternate a given initial molecular state to a desirable end state, wich in this work was represented by the minimization of a cost functional that indicates how close. To do so, a computational sistem know as Genetic Algorithm (GA) was developed that can be characterizes as an extremelly eficient technique capable of scanning the solutions space and find results close to the optimum solutions

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The request of three-dimensional images (3D) of the dentomaxillofacial complex has increased. Hence, new possibilities for assessment, treatment as well as follow-up after treatment have increased their importance with the use of cone beam computed tomography (CBCT). The images in two dimensions (2D) have inherent problems that can be solved with treedimensional images assessment. Objectives: To clarify the main doubts about the operational mechanism of complementary diagnostic method; to explain the advantages and disadvantages, to discuss the effective radiation dose and possible applications in orthodontia. Conclusion: The information generated by 2D images from the CBCT does not show differences that may endanger the orthodontic planning when compared with the images of 2D conventional radiographs. The effective radiation dose received by the patient should not be considered as a limiting factor of the tomography exam request.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Civil e Ambiental - FEB

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Geociências e Meio Ambiente - IGCE