902 resultados para Threshold voltage
Resumo:
The purpose of this work is to study voltage control and energy balance of a split DC bus topology within a power electronics equipment connected to the AC mains, such as UPS systems, wind power generators, active filters and FACTS devices. A typical configuration in such equipment has two mains connected converters sharing a common DC bus, one series connected and the other parallel connected. The DC bus is usually composed by a battery or a capacitor bank. In the proposed topology, the DC bus is divided in two sides, interconnected with a buck-boost converter, which controls power flow and DC voltage on both sides. © 2009 IEEE.
Resumo:
This paper deals with the subject-matter of teaching immaterial issues like power system dynamics where the phenomena and events are not sense-perceptible. The dynamics of the power system are recognized as analogous to the dynamics of a simple mechanical pendulum taken into account the well-known classical model for the synchronous machine. It is shown that even for more sophisticated models including flux decay and Automatic Voltage Regulator the mechanical device can be taken as an analogous, since provided some considerations about variation and control of the pendulum length using certain control laws. The resulting mathematical model represents a mechanical system that can be built for use in laboratory teaching of power system dynamics. © 2010 Praise Worthy Prize S.r.l. - All rights reserved.
Resumo:
To evaluate the effect of acute exercise and exercise training at the anaerobic threshold (AT) intensity on aerobic conditioning and insulin secretion by pancreatic islets, adult male Wistar rats were submitted to the lactate minimum test (LMT) for AT determination. Half of the animals were submitted to swimming exercise training (trained), 1 h/day, 5 days/week during 8 weeks, with an overload equivalent to the AT. The other half was kept sedentary. At the end of the experimental period, the rats were submitted to an oral glucose tolerance test and to another LMT. Then, the animals were sacrificed at rest or immediately after 20 minutes of swimming exercise at the AT intensity for pancreatic islets isolation. At the end of the experiment mean workload (% bw) at AT was higher and blood lactate concentration (mmol/L) was lower in the trained than in the control group. Rats trained at the AT intensity showed no alteration in the areas under blood glucose and insulin during OGTT test. Islet insulin content of trained rats was higher than in the sedentary rats while islet glucose uptake did not differ among the groups. The static insulin secretion in response to the high glucose concentration (16.7 mM) of the sedentary group at rest was lower than the sedentary group submitted to the acute exercise and the inverse was observed in relation to the trained groups. physical training at the AT intensity improved the aerobic condition and altered insulin secretory pattern by pancreatic islets. © 2010 Landes Bioscience.
Resumo:
Aim. The purpose of this study was to compare the anaerobic threshold speed (AT) obtained from fixed lactate blood concentrations (AT 4 mM and AT 3.5 mM), lactate minimum speed (LM) and critical speed (CS), determined from different distances in fifteen Brazilian national level swimmers (10 boys = 14.8 ± 0.6 years old and 5 girls = 14.6 ±0.8 year-old). Methods. The tests to determine the AT 4 mM, AT 3.5 mM, LM and CS were performed in a 25 m swimming pool and consisted of 7 or 8 evaluations separated by 24-48 h intervals. Data were submitted to analysis of variance (ANOVA) for repeated measures, followed by the post hoc Scheffé test and Pearson correlation coefficients. Significance was set at P<0.01. Results. There were no significant differences among the values for AT 4 mM and CS1 (1.34 ± 0.05 vs. 1.33 ± 0.05 m.s -1, respectively). However, AT 4 mM and CS1 were significantly higher than AT 3.5 mM (1.28 ± 0.04 m.s -1), LM (1.27 ± 0.05 m.s -1), CS2 (1.26 ± 0.06 m.s -1), CS3 (1.27 ± 0.06 m.s -1) and CS4 (1.25 ± 0.07 m.s -1). There were no significant differences among the values for AT 3.5 mM, LM, CS2, CS3 and CS4. Conclusion. The results obtained in this study suggest that the anaerobic threshold determined by a fixed lactate concentration of 3.5 mM, as well as the LM and the CS methods determined by different distances, seem to be the most appropriate indexes for the evaluation of aerobic capacity in adolescent swimmers.
Resumo:
In the last 20 years immense efforts have been made to utilize renewable energy sources for electric power generation. This paper investigates some aspects of integration of the distributed generators into the low voltage distribution network. An assessment of impact of the distributed generators on the voltage and current harmonic distortion in the low voltage network is performed. Results obtained from a case study, using real-life low voltage network, are presented and discussed.
Resumo:
Includes bibliography
Resumo:
Includes bibliography
Resumo:
In a general way, in an electric power utility the current transformers (CT) are used to measurement and protection of transmission lines (TL) 1 The Power Line Carriers systems (PLC) are used for communication between electrical substations and transmission line protection. However, with the increasing use of optical fiber to communication (due mainly to its high data transmission rate and low signal-noise relation) this application loses potentiality. Therefore, other functions must be defined to equipments that are still in using, one of them is detecting faults (short-circuits) and transmission lines insulator strings damages 2. The purpose of this paper is to verify the possibility of using the path to the ground offered by the CTs instead of capacitive couplings / capacitive potential transformers to detect damaged insulators, since the current transformers are always present in all transmission lines (TL's) bays. To this a comparison between this new proposal and the PLC previous proposed system 2 is shown, evaluating the economical and technical points of view. ©2010 IEEE.
Resumo:
Two experiments evaluated an operant procedure for establishing stimulus control using auditory and electrical stimuli as a baseline for measuring the electrical current threshold of electrodes implanted in the cochlea. Twenty-one prelingually deaf children, users of cochlear implants, learned a Go/No Go auditory discrimination task (i.e., pressing a button in the presence of the stimulus but not in its absence). When the simple discrimination baseline became stable, the electrical current was manipulated in descending and ascending series according to an adapted staircase method. Thresholds were determined for three electrodes, one in each location in the cochlea (basal, medial, and apical). Stimulus control was maintained within a certain range of decreasing electrical current but was eventually disrupted. Increasing the current recovered stimulus control, thus allowing the determination of a range of electrical currents that could be defined as the threshold. The present study demonstrated the feasibility of the operant procedure combined with a psychophysical method for threshold assessment, thus contributing to the routine fitting and maintenance of cochlear implants within the limitations of a hospital setting.
Resumo:
A voltage reference with low sensibility to temperature and power-supply that can generate flexible reference values (from milivolts to several volts) is proposed. Designed for AMS 0.35μm CMOS process, the circuit provides a stable output voltage working in the temperature range of -40-150°C. The proposed reference provides a nominal output voltage of 1.358V with a power-supply of 3.3V. © 2011 IEEE.
Resumo:
Includes bibliography
Resumo:
This study analyzed the effects of overground walking training at ventilatory threshold (VT) velocity on glycaemic control, body composition, physical fitness and lipid profile in DM2 women. Nineteen sedentary patients were randomly assigned to a control group (CG; n=10, 55.9±2.2 years) or a trained group (TG; n=9, 53.4±2.3 years). Both groups were subjected to anthropometric measures, a 12-h fasting blood sampling and a graded treadmill exercise test at baseline and after a 12-week period, during which TG followed a training program involving overground walking at VT velocity for 20-60min/session three times/week. Significant group×time interactions (P<0.05) in glycated hemoglobin (HbA1c), body mass, body mass index (BMI), peak oxygen uptake (VO 2peak) and exercise duration were observed as effects of training exercise, whereas intervention did not induced significant changes (P>0.05) in fasting blood glucose, submaximal fitness parameters and lipid profile. Our results suggest that overground walking training at VT velocity improves long term glycaemic control, body composition and exercise capacity, attesting for the relevance of this parameter as an effective strategy for the exercise intensity prescription in DM2 population. © 2011 Elsevier B.V.
Resumo:
In this paper, the susceptibility of a current-mode bandgap voltage reference to electromagnetic interference (EMI) superimposed to the power supply is investigated by simulation. Designed for AMS 0.35 CMOS process, the circuit provides a stable voltage reference in the temperature range of -40-150°C. When EMI disturbances are present, the circuit exhibits only 6.7 mV of offset for interfering signals in the frequency range of 150 kHz-1 GHz. © 2011 ACM.
Resumo:
Includes bibliography
Resumo:
Maximum Power Point tracking (MPPT) in photovoltaic (PV) systems may be achieved by controlling either the voltage or current of the PV device. There is no consensus in the technical literature about how is the best choice. This paper provides a comparative analysis performance among current and voltage control using two different MPPT strategies: the perturb and observe (P&O) and the incremental conductance techniques. © 2011 IEEE.