978 resultados para Testing Power
Resumo:
Electric vehicles (EV) offer a great potential to address the integration of renewable energy sources (RES) in the power grid, and thus reduce the dependence on oil as well as the greenhouse gases (GHG) emissions. The high share of wind energy in the Portuguese energy mix expected for 2020 can led to eventual curtailment, especially during the winter when high levels of hydro generation occur. In this paper a methodology based on a unit commitment and economic dispatch is implemented, and a hydro-thermal dispatch is performed in order to evaluate the impact of the EVs integration into the grid. Results show that the considered 10 % penetration of EVs in the Portuguese fleet would increase load in 3 % and would not integrate a significant amount of wind energy because curtailment is already reduced in the absence of EVs. According to the results, the EV is charged mostly with thermal generation and the associated emissions are much higher than if they were calculated based on the generation mix.
Resumo:
The aim of the present work was to investigate the wetting behaviour of biomedical grade Ti-6Al-4V alloy surfaces textured by a femtosecond laser treatment. The material was treated in ambient atmosphere using an Yb: KYW chirped-pulse-regenerative amplification laser with a wavelength of 1030 nm and a pulse duration of 500 fs. Four main types of surface textures were obtained depending on the processing parameters and laser treatment method. These textures consist of: (1) nanoscale laser-induced periodic surface structures (LIPSS); (2) nanopillars; (3) a bimodal roughness distribution texture formed of LIPSS overlapping microcolumns; (4) a complex texture formed of LIPSS overlapping microcolumns with a periodic variation of the columns size in the laser scanning direction. The wettability of the surfaces was evaluated by the sessile drop method using distilled-deionized (DD) water and Hank's balanced salt solution (HBSS) as testing liquids. The laser treated surfaces present a hydrophilic behaviour as well as a high affinity for the saline solution, with equilibrium contact angles in the ranges 24.1-76.2. for DD water and 8.4-61.8. for HBSS. The wetting behaviour is anisotropic, reflecting the anisotropy of the surface textures. (c) 2012 Elsevier B.V. All rights reserved.
Resumo:
A start-up circuit, used in a micro-power indoor light energy harvesting system, is described. This start-up circuit achieves two goals: first, to produce a reset signal, power-on-reset (POR), for the energy harvesting system, and secondly, to temporarily shunt the output of the photovoltaic (PV) cells, to the output node of the system, which is connected to a capacitor. This capacitor is charged to a suitable value, so that a voltage step-up converter starts operating, thus increasing the output voltage to a larger value than the one provided by the PV cells. A prototype of the circuit was manufactured in a 130 nm CMOS technology, occupying an area of only 0.019 mm(2). Experimental results demonstrate the correct operation of the circuit, being able to correctly start-up the system, even when having an input as low as 390 mV using, in this case, an estimated energy of only 5.3 pJ to produce the start-up.
Resumo:
Mestrado em Engenharia Electrotécnica – Sistemas Eléctricos de Energia
Resumo:
Wireless local-area networks (WLANs) have been deployed as office and home communications infrastructures worldwide. The diversification of the standards, such as IEEE 802.11 series demands the design of RF front-ends. Low power consumption is one of the most important design concerns in the application of those technologies. To maintain competitive hardware costs, CMOS has been used since it is the best solution for low cost and high integration processing, allowing analog circuits to be mixed with digital ones. In the receiver chain, the low noise amplifier (LNA) is one of the most critical blocks in a transceiver design. The sensitivity is mainly determined by the LNA noise figure and gain. It interfaces with the pre-select filter and the mixer. Furthermore, since it is the first gain stage, care must be taken to provide accurate input match, low-noise figure, good linearity and a sufficient gain over a wide band of operation. Several CMOS LNAs have been reported during the last decade, showing that the most research has been done at 802.11/b and GSM standards (900-2400MHz spectrum) and more recently at 802.11/a (5GHz band). One of the more significant disadvantages of 802.11/b is that the frequency band is crowded and subject to interference from other technologies, as is 2.4GHz cordless phones and Bluetooth. As the demand for radio-frequency integrated circuits, operating at higher frequency bands, increases, the IEEE 802.11/a standard becomes a very attractive option to wireless communication system developers. This paper presents the design and implementation of a low power, low noise amplifier aimed at IEEE 802.11a for WLAN applications. It was designed to be integrated with an active balun and mixer, representing the first step toward a fully integrated monolithic WLAN receiver. All the required circuits are integrated at the same die and are powered by 1.8V supply source. Preliminary experimental results (S-parameters) are shown and promise excellent results. The LNA circuit design details are illustrated in Section 2. Spectre simulation results focused at gain, noise figure (NF) and input/output matching are presented in Section 3. Finally, conclusions and comparison with other recently reported LNAs are made in Section 4, followed by future work.
Resumo:
Copyright © 2014 The Pennsylvania State University, University Park, PA.
Resumo:
Mestrado em Engenharia Electrotécnica – Sistemas Eléctricos de Energia
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia de Eletrónica e Telecomunicações
Resumo:
Dissertação para a obtenção do grau de Mestre em Engenharia Electrotécnica Ramo de Automação e Electrónica Industrial
Resumo:
Dissertação de Mestrado em Ciências Económicas e Empresariais.
Resumo:
OBJECTIVE: To assess rates of offering and uptake of HIV testing and their predictors among women who attended prenatal care. METHODS: A population-based cross-sectional study was conducted among postpartum women (N=2,234) who attended at least one prenatal care visit in 12 cities. Independent and probabilistic samples were selected in the cities studied. Sociodemographic data, information about prenatal care and access to HIV prevention interventions during the current pregnancy were collected. Bivariate and multivariate analyses were carried out to assess independent effects of the covariates on offering and uptake of HIV testing. Data collection took place between November 1999 and April 2000. RESULTS: Overall, 77.5% of the women reported undergoing HIV testing during the current pregnancy. Offering of HIV testing was positively associated with: previous knowledge about prevention of mother-to-child transmission of HIV; higher number of prenatal care visits; higher level of education and being white. HIV testing acceptance rate was 92.5%. CONCLUSIONS: The study results indicate that dissemination of information about prevention of mother-to-child transmission among women may contribute to increasing HIV testing coverage during pregnancy. Non-white women with lower level of education should be prioritized. Strategies to increase attendance of vulnerable women to prenatal care and to raise awareness among health care workers are of utmost importance.
Resumo:
Tendo em conta a contaminação normal de compostos azotados existente na água de uma piscina, derivados na sua maioria do próprio banhista, é inevitável a formação de subprodutos, quando estes reagem com o cloro como desinfectante. De todos os subprodutos de desinfecção que se formam, as cloraminas, incluídas no controlo químico da água de piscina no parâmetro cloro combinado, são as mais conhecidas. Estes compostos são responsáveis por irritações oculares, das mucosas e do trato respiratório. São estes os compostos responsáveis pelo comummente designado ‘cheiro a cloro’ característico de muitas piscinas. Para além destes efeitos nefastos da sua presença na água, estes compostos possuem um poder desinfectante muito menor ao do ácido hipocloroso, a forma activa do cloro com maior capacidade desinfectante. Por todas estas razões, uma piscina com uma concentração de cloro combinado elevada não é adequada para uso. Com a premissa comprovada em diversos estudos do uso de zeólitos para diminuição de compostos amoniacais por adsorção, é objectivo deste estudo comprovar a sua viabilidade no uso da redução destes compostos nas águas de piscinas. Para tal, foram realizados estudos em contínuo, numa piscina piloto onde foram aplicados hipoclorito de sódio e amoníaco, e ensaios em descontínuo, para que fosse determinada a capacidade e o tempo necessário ao equilíbrio de adsorção para este par adsorvente/adsorvato. Nos ensaios em contínuo, a clinoptilolite adsorveu 1,652 g Cl2/kg de clinoptilolite, em aproximadamente 300 horas de funcionamento, a 23,5 ºC. Nos ensaios em descontínuo, foram estudadas diferentes concentrações iniciais de cloro combinado. Os ensaios foram realizados a 20 ºC. Para uma concentração inicial de 4,06 mg/L Cl2, obteve-se uma capacidade de adsorção de 0,28 g Cl2/kg de clinoptilolite, ao fim de 360 horas. Para uma concentração inicial de 2 mg / L Cl2, o ensaio teve uma duração de 360 horas, e não se verificou estabilização. No entanto, findo este tempo, ocorreu a adsorção de 0,28 g Cl2/kg de clinoptilolite. Para uma concentração inicial de 0,56 mg/L Cl2, obteve-se um valor inferior, de 0,027 g Cl2/kg de clinoptilolite ao fim de 168 horas.
Resumo:
This thesis presents the Fuzzy Monte Carlo Model for Transmission Power Systems Reliability based studies (FMC-TRel) methodology, which is based on statistical failure and repair data of the transmission power system components and uses fuzzyprobabilistic modeling for system component outage parameters. Using statistical records allows developing the fuzzy membership functions of system component outage parameters. The proposed hybrid method of fuzzy set and Monte Carlo simulation based on the fuzzy-probabilistic models allows catching both randomness and fuzziness of component outage parameters. A network contingency analysis to identify any overloading or voltage violation in the network is performed once obtained the system states. This is followed by a remedial action algorithm, based on Optimal Power Flow, to reschedule generations and alleviate constraint violations and, at the same time, to avoid any load curtailment, if possible, or, otherwise, to minimize the total load curtailment, for the states identified by the contingency analysis. For the system states that cause load curtailment, an optimization approach is applied to reduce the probability of occurrence of these states while minimizing the costs to achieve that reduction. This methodology is of most importance for supporting the transmission system operator decision making, namely in the identification of critical components and in the planning of future investments in the transmission power system. A case study based on Reliability Test System (RTS) 1996 IEEE 24 Bus is presented to illustrate with detail the application of the proposed methodology.
Resumo:
OBJECTIVE: To assess the feasibility of HIV rapid testing for pregnant women at maternity hospital admission and of subsequent interventions to reduce perinatal HIV transmission. METHODS: Study based on a convenience sample of women unaware of their HIV serostatus when they were admitted to delivery in public maternity hospitals in Rio de Janeiro and Porto Alegre, Brazil, between March 2000 and April 2002. Women were counseled and tested using the Determine HIV1/2 Rapid Test. HIV infection was confirmed using the Brazilian algorithm for HIV infection diagnosis. In utero transmission of HIV was determined using HIV-DNA-PCR. There were performed descriptive analyses of sociodemographic data, number of previous pregnancies and abortions, number of prenatal care visits, timing of HIV testing, HIV rapid test result, neonatal and mother-to-child transmission interventions, by city studied. RESULTS: HIV prevalence in women was 6.5% (N=1,439) in Porto Alegre and 1.3% (N=3.778) in Rio de Janeiro. In Porto Alegre most of women were tested during labor (88.7%), while in Rio de Janeiro most were tested in the postpartum (67.5%). One hundred and forty-four infants were born to 143 HIV-infected women. All newborns but one in each city received at least prophylaxis with oral zidovudine. It was possible to completely avoid newborn exposure to breast milk in 96.8% and 51.1% of the cases in Porto Alegre and Rio de Janeiro, respectively. Injectable intravenous zidovudine was administered during labor to 68.8% and 27.7% newborns in Porto Alegre and Rio de Janeiro, respectively. Among those from whom blood samples were collected within 48 hours of birth, in utero transmission of HIV was confirmed in 4 cases in Rio de Janeiro (4/47) and 6 cases in Porto Alegre (6/79). CONCLUSIONS: The strategy proved feasible in maternity hospitals in Rio de Janeiro and Porto Alegre. Efforts must be taken to maximize HIV testing during labor. There is a need of strong social support to provide this population access to health care services after hospital discharge.
Resumo:
In this paper, we characterize two power indices introduced in [1] using two different modifications of the monotonicity property first stated by [2]. The sets of properties are easily comparable among them and with previous characterizations of other power indices.