996 resultados para Test tailoring, specifica tecnica, kurtosis, danno a fatica


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Micro-scale abrasion (ball cratering) tests were performed with different combinations of ball and bulk specimen materials, under different test conditions, such as load and abrasive slurry concentration. Wear modes were classified into two types: with rolling particle motion and with grooving particle motion. Wear rates observed with rolling particle motion were relatively insensitive to test conditions, whereas with grooving motion they varied much more. It is suggested that rolling abrasion is therefore a more appropriate mode if reproducible test results are desired. The motion of the abrasive particles can be reliably predicted from the knowledge of hardnesses and elastic properties of the ball and the specimen, and from the normal load and the abrasive slurry concentration. General trends in wear resistance measured in the micro-scale abrasion test with rolling particle motion are similar to those reported in tests with fixed abrasives with sliding particle motion, although the variation in wear resistance with hardness is significantly smaller. © 2004 Published by Elsevier B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the 'free-ball' version of the micro-scale abrasion or ball-cratering test the rotating ball rests against a tilted sample and a grooved drive shaft. Tests under nominally identical conditions with different apparatus commonly show small but significant differences in measured wear rate. An indirect method has been developed and demonstrated for continuous on-line measurement of the coefficient of friction in the free-ball test. Experimental investigation of the effects of sample tilt angle and drive shaft groove width shows that both these factors influence the stability of the rotation of the ball, and the shape of the abrasive slurry pool, which in turn affect the coefficient of friction in the wear scar area and the measured wear rate. It is suggested that in order to improve the reproducibility of this method the geometry of the apparatus should be specified. For the apparatus used in this work with a steel ball of 25 mm diameter, a sample tilt angle of 60-75° and a shaft groove width of about 10mm provided the most stable ball motion and a wear rate which showed least variability. © 2004 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Testing was conducted of a computer-assisted system for matching humpback whale tail flukes photographs. Trials with a 12,000-photographs database found no differences in match success between matching by computer and matching by comparing smaller catalogs ranging in size from 200 to 400 photographs. Tests with a 24,000-photographs database showed that, on average, the first match was found after examining about 130 photographs whether the photograph quality was excellent, good, or poor. Match success did not appear to be strongly related to whether the tail flukes had especially distinctive markings or pigment patterns (recognition quality). An advantage of computer-assisted matching is the ability to compare new photographs to the entire North Pacific collection, where no bias is introduced based on expectation of resightings within or between specific areas, or based on expectation of behavioral role (e.g. matching “known” females to “known” females).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sinais diversos estão presentes em nosso cotidiano, assim como nas medidas realizadas nas atividades de ciência e tecnologia. Dentre estes sinais, tem grande importância tecnológica aqueles associados à corrosão de estruturas metálicas. Assim, esta tese propõe o estudo de um esquema local de transformada de Fourier janelada, com a janela variando em função da curtose, aplicada a sinais de ruído eletroquímico. A curtose foi avaliada nos domínios do tempo e da frequência e processada pelo programa desenvolvido para esse fim. O esquema foi aplicado a sinais de ruído eletroquímico dos aços UNS S31600, UNS G10200 e UNS S32750 imersos em três soluções: FeCl3 0,1 mol=L (cloreto férrico), H2SO4 5%(ácido sulfúrico) e NaOH 0,1%(hidróxido de sódio). Para os aços inoxidáveis, estas soluções promovem corrosão localizada, uniforme e passivação, respectivamente. Visando testar o desempenho do esquema de Fourier desenvolvido, testes foram realizados utilizando-se inicialmente sinais sintéticos e em seguida sinais de ruído eletroquímico. Notou-se que os sinais têm características de não-estacionaridade e a maior parte da energia está presente em baixa frequência. Os intervalos de tempo e de frequência onde se concentra a maior parte da energia do sinal foram correlacionados. Para os picos máximos dos sinais de potencial e corrente obtidos de amperimetria de resistência nula, a correlação entre eles foi baixa, independente da forma de corrosão presente. Conclui-se que o método se adaptou bastante bem às características locais do sinal eletroquímico permitindo o monitoramento dos espectros tempo-frequência. O fato de ser sensível às características locais do sinal permite analisar aspectos dos sinais que do modo clássico não podem ser diretamente processados. O método da transformada de Fourier janelada variável (Variable Short-Time Fourier Transform - VSTFT) adaptou-se muito bem no monitoramento dos sinais originados de potencial de circuito aberto e amperimetria de resistência nula.