901 resultados para TRANSIENT SPECTROSCOPY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mammalian reoviruses exhibit a large host range and infected cells are generally killed; however, most studies examined only a few cell types and host species, and are probably not representative of all possible interactions between virus and host cell. Many questions thus remain concerning the nature of cellular factors that affect viral replication and cell death. In the present work, it was observed that replication of the classical mammalian reovirus serotype 3 Dearing in a bat epithelial cell line, Tb1.Lu, does not result in cell lysis and is rapidly reduced to very low levels. Prior uncoating of virions by chymotrypsin treatment, to generate infectious subviral particles, increased the initial level of infection but without any significant effect on further viral replication or cell survival. Infected cells remain resistant to virus reinfection and secrete an antiviral factor, most likely interferon, that is protective against the unrelated encephalomyocarditis virus. Although, the transformed status of a cell is believed to promote reovirus replication and viral “oncolysis”, resistant Tb1.Lu cells exhibit a classical phenotype of transformed cells by forming colonies in semisolid soft agar medium. Further transduction of Tb.Lu cells with a constitutively-active Ras oncogene does not seem cell growth or reovirus effect on these cells. Infected Tb1.Lu cells can produce low-level of infectious virus for a long time without any apparent effect, although these cells are resistant to reinfection. The results suggest that Tb1.Lu cells can mount an unusual antiviral response. Specific properties of bat cells may thus be in part responsible for the ability of the animals to act as reservoirs for viruses in general and for novel reoviruses in particular. Their peculiar resistance to cell lysis also makes Tb1.Lu cells an attractive model to study the cellular and viral factors that determine the ability of reovirus to replicate and destroy infected cells.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Materials and equipment which fail to achieve the design requirements or projected life due to undetected defects may require expensive repair or early replacement. Such defects may also be the cause of unsafe conditions or catastrophic unexpected failure, and will lead to loss of revenue due to plant shutdown. Non-Destructive Evaluation (NDE) / Non Destructive Testing (NDT) is used for the examination of materials and components without changing or destroying their usefulness. NDT can be applied to each stage of a system’s construction, to monitor the integrity of the system or structure throughout its life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The radio frequency plasma generated during the sputtering of Indium Tin Oxide target using Argon was analyzed by Langmuir probe and optical-emission spectroscopy. The basic plasma parameters such as electron temperature and ion density were evaluated. These studies were carried out by varying the RF power from 20 to 50 W. A linear increase in ion density and an exponential decrease in electron temperature with rf power were observed. The measured plasma parameters were then correlated with the properties of ITO thin films deposited under similar plasma conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work is mainly concentrated on setting up a NIR tunable diode laser absorption (TDLA) spectrometer for high-resolution molecular spectroscopic studies. For successfully recording the high-resolution tunable diode laser spectrum, various experimental considerations are to be taken into account like the setup should be free from mechanical vibrations, sample should be kept at a low pressure, laser should be in a single mode operation etc. The present experimental set up considers all these factors. It is to be mentioned here that the setting up of a high resolution NIR TDLA spectrometer is a novel experiment requiring much effort and patience. The analysis of near infrared (NIR) vibrational overtone spectra of some substituted benzene compounds using local mode model forms another part of the present work. An attempt is made to record the pulsed laser induced fluorescence/Raman spectra of some organic compounds. A Q-switched Nd:YAG laser is used as the excitation source. A TRIAX monochromator and CCD detector is used for the spectral recording. The observed fluorescence emission for carbon disulphide is centered at 680 nm; this is assigned as due to the n, p* transition. Aniline also shows a broad fluorescence emission centered at 725 nm, which is due to the p,p* transition. The pulsed laser Raman spectra of some organic compounds are also recorded using the same experimental setup. The calibration of the set up is done using the laser Raman spectra of carbon tetrachloride and carbon disulphide. The observed laser Raman spectra for aniline, o-chloroaniline and m-chlorotoluene show peaks characteristics of the aromatic ring in common and the characteristics peaks due to the substitutuent groups. Some new peaks corresponding to low-lying vibrations of these molecules are also assigned

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The transient interaction between a refraction index grating and light beams during simultaneous writing and thermal fixing of a photorefractive hologram is investigated. With a diffusion- and photovoltaic-dominated carrier transport mechanism and carrier thermal activation (temperature dependent) considered in Fe:LiNbO3 crystal, from the standpoint of field-material coupling, the theoretical thermal fixing time and the space-charge field buildup, spatial distribution, and temperature dependence are given numerically by combining the band transport model with mobile ions with the coupled-wave equation

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The transient characteristics of an erbium-doped fiber (F.DF) laser, which can switch between wavelengths. are investigated. 77te laser has a set of coupled linear cavities. The slow gain dynamics of EDFs and the cross-gain saturation in the coupled cavities give rise to delayed switching responses and relocation oscillations, which are respertively measured to be l ins and 3.5 ms for the worst rase, and which mar be decreased by increasing the pump power. Thus, the switching speed of the laser may be higher than 100 Hz

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biophotonics Laboratory,Centre for Earth Science Studies

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Laser produced plasma from silver is generated using a Q-switched Nd:YAG laser. Optical emission spectroscopy is used to carry out time of flight (TOF) analysis of atomic particles. An anomalous double peak profile in the TOF distribution is observed at low pressure. A collection of slower species emerge at reduced pressure below 4 X lO-3 mbar and this species has a greater velocity spread. At high pressure the plasma expansion follows the shockwave model with cylindrical symmetry whereas at reduced pressure it shows unsteady adiabatic expansion (UAE). During UAE the species show a parabolic increases in the expansion time with radial distance whereas during shock wave expansion the exponent is less than one. The angular distribution of the ablated species in the plume is obtained from the measurement of optical density of thin films deposited on to glass substrates kept perpendicular to the plume. There is a sharp variation in the film thickness away from the film centre due to asymmetries in the plume.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thermal diffusivity measurements are carried out in certain organic liquids using the pulsed dual beam thermal lens technique. The 532 nm pulses from a frequency doubled Q-switched Nd:YAG laser are used as the heating source and an intensity stabilized He-Ne laser serves as the probe beam. Experimental determination of the characteristic time constant of the transient thermal lens signal is verified theoretically. Measured thermal diffusivity values are in excellent agreement with literature values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dual-beam transient thermal lens studies were carried out in aqueous solutions of rhodamine 6G using 532 nm pulses from a frequency-doubled Nd:YAG laser. The analysis of the observed data showed that the thermal lens method can effectively be utilized to study the nonlinear absorption and aggregation which are taking place in a dye medium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report time resolved study of C2 emission from laser produced carbon plasma in presence of ambient helium gas. The 1.06µm: radiation from a Nd:YAG laser was focused onto a graphite target where it·produced a transient plasma. We observed double peak structure in the time profile of C2 species. The twin peaks were observed only after a threshold laser fluence. It is proposed that the faster velocity component in the temporal profiles originates mainly due to recombination processes. The laser fluence and ambient gas dependence of the double peak intensity distribution is also reported.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dual beam thermal lens tecbnique is successfully employed for the determination of absolute Fluorescence quantum yield of rhodamine 6G lnser dye in different solvents. A 532 nm radiation from a Q-switched Nd:YAG laser was used for the excitation purpose. The fluorescence quantum yield values are found to be strongly influenced by environmental effects. It has been observed that fluorescence yield is greater for rhodamine 6G in ethylene glycol system than in water or in methanol. Our results also indicate that parameters like concentration of the dye solution, aggregate formation and excited state absorption affect the absolute values of fluorescence yield significantly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main objective of the present study is to understand different mechanisms involved in the production and evolution of plasma by the pulsed laser ablation and radio frequency magnetron sputtering. These two methods are of particular interest, as these are well accomplished methods used for surface coatings, nanostructure fabrications and other thin film devices fabrications. Material science researchers all over the world are involved in the development of devices based on transparent conducting oxide (TCO) thin films. Our laboratory has been involved in the development of TCO devices like thin film diodes using zinc oxide (ZnO) and zinc magnesium oxide (ZnMgO), thin film transistors (TFT's) using zinc indium oxide and zinc indium tin oxide, and some electroluminescent (EL) devices by pulsed laser ablation and RF magnetron sputtering.In contrast to the extensive literature relating to pure ZnO and other thin films produced by various deposition techniques, there appears to have been relatively little effort directed towards the characterization of plasmas from which such films are produced. The knowledge of plasma dynamics corresponding to the variations in the input parameters of ablation and sputtering, with the kind of laser/magnetron used for the generation of plasma, is limited. To improve the quality of the deposited films for desired application, a sound understanding of the plume dynamics, physical and chemical properties of the species in the plume is required. Generally, there is a correlation between the plume dynamics and the structural properties of the films deposited. Thus the study of the characteristics of the plume contributes to a better understanding and control of the deposition process itself. The hydrodynamic expansion of the plume, the composition, and SIze distribution of clusters depend not only on initial conditions of plasma production but also on the ambient gas composition and pressure. The growth and deposition of the films are detennined by the thermodynamic parameters of the target material and initial conditions such as electron temperature and density of the plasma.For optimizing the deposition parameters of various films (stoichiometric or otherwise), in-situ or ex-situ monitoring of plasma plume dynamics become necessary for the purpose of repeatability and reliability. With this in mind, the plume dynamics and compositions of laser ablated and RF magnetron sputtered zinc oxide plasmas have been investigated. The plasmas studied were produced at conditions employed typically for the deposition of ZnO films by both methods. Apart from this two component ZnO plasma, a multi-component material (lead zirconium titanate) was ablated and plasma was characterized.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this article we present size dependent spectroscopic observations of nanocolloids of ZnO. ZnO is reported to show two emission bands, an ultraviolet (UV) emission band and another in the green region. Apart from the known band gap 380 nm and impurity 530 nm emissions, we have found some peculiar features in the fluorescence spectra that are consistent with the nanoparticle size distribution. Results show that additional emissions at 420 and 490 nm are developed with particle size. The origin of the visible band emission is discussed. The mechanism of the luminescence suggests that UV luminescence of ZnO colloid is related to the transition from conduction band edge to valence band, and visible luminescence is caused by the transition from deep donor level to valence band due to oxygen vacancies and by the transition from conduction band to deep acceptor level due to impurities and defect states. A correlation analysis between the particle size and spectroscopic observations is also discussed.