707 resultados para Study protocol
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Several countries have invested in technologies for Smart Grids. Among such protocols designed cover this area, highlights the DNP3 (Distributed Network Protocol version 3). Although the DNP3 be developed for operation over the serial interface, there is a trend in the literature to the use of other interfaces. The Zigbee wireless interface has become more popular in the industrial applications. In order to study the challenges of integrating of these two protocols, this article is presented the analysis of DNP3 protocol stack through state machines The encapsulation of DNP3 messages in P2P (point-to-point) ZigBee Network, may assist in the discovery and solution of failures of availability and security of this integration. The ultimate goal is to merge the features of DNP3 and Zigbee stacks, and display a solution that provides the benefits of wireless environment, without impairment of security required for Smart Grid applications.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The aim of the present study was to evaluate the effects of type of norgestomet auricular implant (new - N or previously used during 5 days - U), season of the year (summer - S and winter - W), and parity (12 heifers - H and 23 cows - C) on synchronization of follicular wave emergence in buffaloes. For this purpose, 35 buffaloes were examined daily by ultrasonography until follicular wave emergence was detected. Data were analysed by ANOVA, using PROC GLIMMIX. No interactions were observed in none variables. Time of follicular wave emergence and number of follicles at emergence were not affected by type of implant or season of the year. Parity also did not influence the number of follicles at emergence. However, follicular wave emergence occurred later in heifers than in cows. In conclusion, the previous use of a norgestomet auricular implant independent of the season of the year does not affect the time or the number of follicles at follicular wave emergence in buffaloes. Nevertheless, although heifers and cows had a similar number of follicles at emergence, the time of follicular wave emergence occurs earlier in cows than in heifers.
Resumo:
Introduction: Prognostic factors are used in the Intensive Care Unit (ICU) to predict morbidity and mortality , especially in patients on mechanical ventilation (MV ) . Training protocols are used in MV patients with the aim of promoting the success of the weaning process. Objective: To assess which variables determine the outcome of patients undergoing mechanical ventilation and compare the effects of two protocols for weaning. Method: Patients under MV for more than 48 hours had collected the following information: sex, age , ideal weight, height , Acute Physiology and Chronic Health Evaluation (APACHE II), risk of mortality, Glasgow Coma Scale (GCS) and index Quick and perfunctory (IRRS) breathing. Patients with unsuccessful weaning performed one of weaning protocols: Progressive T - tube or tube - T + Threshold ® IMT. Patients were compared for outcome (death or non- death in the ICU ) and the protocols through the t test or Mann-Whitney test was considered significant when P <0.05. Results: Of 128 patients evaluated 56.25% were men, the mean age was 60.05 ± 17.85 years and 40.62 % patients died, and they had higher APACHE II scores, mortality risk, time VM and IRRS GCS and the lower value (p<0.05). The age, initial and final maximal inspiratory pressure, time of weaning and duration of MV was similar between protocols. Conclusion: The study suggests that the GCS, APACHE II risk of mortality, length of MV and IRRS variables determined the evolution of MV patients in this sample. Not found differences in the variables studied when comparing the two methods of weaning.
Resumo:
Purpose: The execution of adjustments on ceramic restorations is sometimes necessary for either correction of occlusion and/or inadequate contours or esthetical improvements. Clinically, the surfaces undergo weariness through fine grinding diamond burs which remove the superficial glazing layer. Several materials for ceramic polishing have been used in an attempt to reach a satisfactory surface smoothness. The aim of this study was to perform a literature review on different polishing protocols of several dental ceramics. Study selection: This is a literature review performed through scientific articles published between 2004 and 2012, indexed in MEDLINE, PubMed and Scielo databases. The study selected and analyzed a total of 20 relevant articles that evaluated different types of ceramics, polishing treatment and surface roughness.Results: After an extensive literature review, this study observed: 1 - after the rupture of the glazing layer due to the adjustments of the restorations, the best choice for the polishing of the surface will depend on the type of ceramics used; 2 - glazing procedure provide excellent results regarding to the superficial smoothness; however, if reglazing is impossible, either abrasive rubber cups/points or sandpaper discs followed by the use of diamond polishing pastes results in a satisfactory superficial smoothness; 3 - clinical studies that take into account the behavior of the protocols polishing are scarce and should be encouraged; 4 - the large number of variables influence the final outcome of polishing should be considered. Conclusions: The necessity in standardization of methodologies to enable a comparison among researches. (c) 2014 Japan Prosthodontic Society. Published by Elsevier Ireland. All rights reserved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Introduction The aim of this study was to compare the effect of QMix, BioPure MTAD, 17 % EDTA, and saline on the penetrability of a resin-based sealer into dentinal tubules using a confocal laser scanning microscope (CLSM) and to describe the cleaning of root canal walls by SEM. Methods Eighty distobuccal roots from upper molars were selected and randomly divided into four groups (n=20) before root canal preparation according to the solution used in the final rinse protocol (FRP): QG (QMix), MG (BioPure MTAD), EG (17 % EDTA), and CG (control group: saline). Ten roots of each group were prepared for SEM, and images (×2000) from the canal walls were acquired. The remaining canals were filled with a single gutta-percha cone and AH Plus with 0.1 % Rhodamine B. The specimens were horizontally sectioned at 4 mm from the apex, and the slices were analyzed in CLSM (×10). Sealer penetration was analyzed with Adobe Photoshop software. Results QG and EG presented similar amounts of sealer penetration (P>.05). MG and CG presented the lowest penetrability values (P<.05). The best results for smear layer removal of the apical third of the root canal were achieved by the QG and EG groups when compared with MG and CG (P<.05). Conclusions Seventeen percent EDTA and QMix promoted sealer penetration superior to that achieved by BioPure MTAD and saline. Clinical relevance Despite studies have not confirmed the relationship between sealing ability of endodontic sealers and their penetration in dentinal tubules, sealer penetration assumes importance, since endodontic sealers, unlike guttapercha, are able to penetrate in dentinal tubules, isthmus, and accessory canals, filling the root canal system.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Objective: A morphological and ultra-structural study of copper vapor laser (λ = 510.6 nm) effects on enamel and dentine was performed to show the effects of this radiation. Methods: A total of 15 human molars were cut in half; 15 pieces were separated for irradiation on enamel and 15 for dentine. These two groups were further divided into five experimental groups, including a control group, comprised of three half-sections each, irradiated by a CVL laser with a power of 7 W, a repetition rate of 15,000 pulses/sec and exposed at 500, 600, and 800 msec and 1 sec irradiation times with a 5-sec interval between irradiations. Results: In an ultra-structural SEM exam, we observed that on the enamel surfaces irradiated for 1 sec there was morphological alteration that consisted of catering, flaking, and melting on the surfaces. There was no alteration for the other exposure times. On the dentine teeth irradiated for 1 sec, we observed an evident ultra-structural alteration of melted tissue and loss of morphological characteristics. In the dentine group irradiated by 800 msec, we observed ablation and a partial loss of morphological characteristics. In the dentine groups irradiated by 500 and 600 msec, no alteration was observed. Conclusions: The results showed that irradiation with CVL promoted morphologic changes in the enamel as well as in the dentine and demonstrated a need for future studies in order to establish a safe protocol for further use in the odontological practice.
Resumo:
The purpose of this study was to compare the quantity and quality of platelets in platelet-rich plasma (PRP) samples prepared using either the single- or the double-centrifugation protocol. Ten adult white New Zealand rabbits were used. Ten ml of blood were drawn from each animal via cardiac puncture. Each blood sample was divided into two equal parts for PRP preparation: 5 ml of blood were centrifuged according to a single-centrifugation protocol (Group I), and 5 ml were centrifuged according to a double-centrifugation protocol (Group II). Manual platelet counts were performed on the whole blood and PRP samples of each group. Smears were also done on all samples in order to see the morphology of the platelets. The data obtained in the manual platelet count were submitted to statistical analysis (repeated measures ANOVA, Tukey, P<.05). The average whole blood platelet count was 446,389/μl. The PRP samples in Group II presented an average platelet amount significantly higher than that of Group I (1,986,875 ± 685,020/μl and 781,875 ± 217,693/μl, respectively). The PRP smears from Group II were the only one to present platelets with altered morphology (75% of the smears). A few lymphocytes with increased cytoplasm were observed in the PRP smears of both Groups I (25% of the smears) and II (62.5% of the smears). Within the limits of this study, it can be concluded that the double-centrifugation protocol resulted in higher platelet concentrations than did the single-centrifugation protocol. However, the double-centrifugation protocol caused alterations in platelet morphology and was more sensitive to small processing errors.
Resumo:
Recent work with P-36 demonstrates that the replacement of the last two doses of Follicle-Stimulating Hormone (FSH) with equine chorionic gonadotropin (eCG) increases embryo yields. However, it is unclear if the positive effect of eCG is related to its FSH-like activity, LH-like activity, or both. This study aimed to verify the replacement of eCG with pLH on the last day of superstimulatory treatment. Twenty-five Nelore cows were allocated to four groups: P-36 (control), P-36/eCG, P-36/LH2, and P-36/LH4. All animals underwent four treatments in a crossover design. The control group cows were superstimulated with decreasing doses of porcine Follicle-Stimulating Hormone (pFSH, 133 mg, im). In the P-36/eCG, P-36/LH2, and P-36/LH4 groups, the last two doses of pFSH were replaced in the former group by two doses of eCG (200 IU each dose, im) and in the latter two groups by two doses of pLH (1 and 2 mg each dose, im), respectively. Donors received fixed-time artificial insemination 12 and 24 hours after pLH. Embryo flushing was performed on D16. Data were analyzed by ANOVA (Proc Mixed, SAS). There was a trend of decreasing ovulation rate when comparing groups LH2 and eCG (P = 0.06). However, there was no significant difference in the mean number of viable embryos among groups P-36 (3.3 ± 0.7), P-36/eCG (4.5 ± 0.5), P-36/LH2 (3.7 ± 0.8), and P-36/LH4 (4.2 ± 1.0). It is concluded that the replacement of eCG by pLH on the last day of superstimulatory treatment can be performed with no significant variation in the production of viable embryos.
Resumo:
We compared the effects of two anesthesia protocols in both immediate recovery time (IRT) and postoperative respiratory complications (PRCs) after laparotomy for bariatric surgery, and we determined the association between the longer IRT and the increase of PRC incidence. We conducted the study in two stages: (i) in a randomized controlled trial (RCT), patients received either intervention (sevoflurane-remifentanil-rocuronium-ropivacaine) or control protocol (isoflurane-sufentanil-atracurium-levobupivacaine). All patients received general anesthesia plus continuous epidural anesthesia and analgesia. Treatment was masked for all, except the provider anesthesiologist. We defined IRT as time since anesthetics discontinuation until tracheal extubation. Primary outcomes were IRT and PRCs incidence within 15 days after surgery. We also analyzed post-anesthesia care unit (PACU) and hospital length of stays; (ii) after the end of the RCT, we used the available data in an extension cohort study to investigate IRT > 20 min as exposure factor for PRCs. Control protocol (n = 152) resulted in longer IRT (30.4 ± 7.9 vs 18.2 ± 9.6 min; p < 0.0001), higher incidence of PRCs (6.58 vs 2.5 %; p = 0.048), and longer PACU and hospital stays than intervention protocol (n = 200); PRC relative risk (RR) = 2.6. Patients with IRT > 20 min (n = 190) presented higher incidence of PRCs (7.37 vs 0.62 %; p < 0.0001); RR = 12.06. Intervention protocol, with short-acting anesthetics, was more beneficial and safe compared to control protocol, with long-acting drugs, regarding the reduction of IRT, PRCs, and PACU and hospital stays for laparotomy in bariatric patients. We identified a 4.5-fold increase in the relative risk of PRCs when morbid obese patients are exposed to an IRT > 20 min.