973 resultados para Statistical evaluation
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
In view of the diversity of environments found in the Brazilian territory, it is understandable that the use of native species can provide more relevant information for ecotoxicological studies. The purpose of this work was to evaluate the quality of water samples from the Atibaia River in an area that is under the influence of petroleum refinery using a native test-organism and submitting the data to PCA statistical analysis. Therefore, acute toxicity assays with Lecane bulla (Rotifera) were performed in four locations of the river, as well as physical-chemical analyses. Sampling was drawn in the dry and rainy seasons. The bioassays were static and lasted 48 hours; dead organisms were quantified at the end of the tests. Toxicological differences among the samples/per location and control were compared by means of the Analysis of Variance. Physical-chemical and mortality variables were simultaneously analyzed by multivariate analysis of the principal components and the Pearson correlation coefficient. Water samples from the exit of the refinery stabilization pond (location S.1) were toxic to L. bulla in both seasons, with significant differences in relation to the control and between the seasons. The statistical treatment of data showed that mortality was strong and positively correlated with total hardness, chlorides and EC, which together with pH presented higher values in location S.1, in the dry and in the rainy seasons. Due to its sensibility to the quality of the Atibaia river water samples, the potential use of L. bulla for ecotoxicological studies as an alternative test organism could be demonstrated.
Resumo:
OBJECTIVE: To compare the strength generated by the rotator muscles of the shoulder joint between the right upper limb and left upper limb among healthy individuals. METHODS: To evaluate the muscle strength of upper limbs from isometric contractions in the horizontal direction (rotation) an isometric dynamometer was used, equipped with transducers, signal conditioning, a data acquisition board, and finally, a computer. Study participants were 22 male military subjects, aged between 18 and 19 years old, body mass between 57.7 and 93.0 kg (71.8 ± 9.45 kg) and height between 1.67 and 1.90 m (1.75 ± 0.06 m), healthy and without clinical diseases or any type of orthopedic injury in the muscle skeletal system. RESULTS: The internal rotation in the right upper limb (RUL) was higher than the average strength of internal rotation in the left upper limb (LUL) (p = 0.723). The external rotation strength in RUL was lower than the average strength of external rotation in the LUL (p=0.788). No statistical difference was observed by comparing the strength values of all isometric strength tests. CONCLUSION: For the sample and methodology used to assess muscle strength, there was no statistical difference between the strength generated by the muscles of the rotator cuff of the right and left upper limbs. Experimental Study.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This study aimed to assess measurements of temperature and relative humidity obtained with HOBO a data logger, under various conditions of exposure to solar radiation, comparing them with those obtained through the use of a temperature/relative humidity probe and a copper-constantan thermocouple psychrometer, which are considered the standards for obtaining such measurements. Data were collected over a 6-day period (from 25 March to 1 April, 2010), during which the equipment was monitored continuously and simultaneously. We employed the following combinations of equipment and conditions: a HOBO data logger in full sunlight; a HOBO data logger shielded within a white plastic cup with windows for air circulation; a HOBO data logger shielded within a gill-type shelter (multi-plate prototype plastic); a copper-constantan thermocouple psychrometer exposed to natural ventilation and protected from sunlight; and a temperature/relative humidity probe under a commercial, multi-plate radiation shield. Comparisons between the measurements obtained with the various devices were made on the basis of statistical indicators: linear regression, with coefficient of determination; index of agreement; maximum absolute error; and mean absolute error. The prototype multi-plate shelter (gill-type) used in order to protect the HOBO data logger was found to provide the best protection against the effects of solar radiation on measurements of temperature and relative humidity. The precision and accuracy of a device that measures temperature and relative humidity depend on an efficient shelter that minimizes the interference caused by solar radiation, thereby avoiding erroneous analysis of the data obtained.
Resumo:
OBJECTIVE: To assess the presence of microorganism contamination in the preservation solution for transplant organs (kidney/pancreas). Method: Between August 2007 and March 2008, 136 samples of preservation solution were studied prior to graft implantation. Variables related to the donor and to the presence of microorganisms in the preservation solution of organs were evaluated, after which the contamination was evaluated in relation to the recipient culture variable. Univariate and multivariate statistical analyses were performed. RESULTS: The contamination rate of the preservation solution was 27.9%. Coagulase-negative Staphylococcus was the most frequently isolated microorganism. However, highly virulent agents, such as fungi and enterobacteria, were also isolated. In univariate analysis, the variable donor antibiotic use was significantly associated to the contamination of the preservation solution. on the other hand, multivariate analysis found statistical significance in donor antibiotic use and donor's infectious complications variables. CONCLUSIONS: In this study, 27.9% of the preservation solutions of transplant organs were contaminated. Infectious diseases and non-use of antibiotics by the donor were significantly related to the presence of microorganisms in organ preservation solutions. Contamination in organ preservation solutions was not associated with infection in the recipient.
Resumo:
The use of bowel segments to perform bladder augmentation is associated with several metabolic and surgical complications. A great variety of synthetic materials, biodegradable or not, have been tested. Collagen-based biomaterials have shown effectiveness for the regeneration and obtainment of a functional bladder. Assess the functional and histological response of the rabbit bladder to anionic collagen membrane (ACM), either when it is anastomosed to the bladder or it is placed onto bladder after vesicomyectomy. In 15 male rabbit a partial cystectomy was performed. After 4 weeks they were divided in 3 groups. Group 1 (G1) - bladder augmentation with ACM. Group 2 (G2) ACM is placed onto bladder after vesicomyectomy. Group 3 (G3) control group. Maximal bladder capacity (MBC) and weight were assessed with 4 (M1), 8 (M2) and 12 (M3) weeks after partial cystectomy. In M3 was performed the sacrifice and extraction of the bladder and kidneys for anatomopathologic study. There were neither bladder stones, nor implant extrusion in M3. There was a significant increase in MBC in G1 and G2 (p<0.05), but no statistical differences in G3 (p=0.35). There is no significant difference comparing G1 and G2. In M3, both groups have shown a bigger MBC than G3 (p<0.05). The microscopic assessment showed an inflammatory reaction in the bladder augmented, with urothelium preserved. The ACM was effective for the increase of MBC. The bladders with preservation of the urothelium have shown an extensive inflammatory process.
Resumo:
The purpose of this study was to evaluate, in vitro, the chromatic behavior of esthetic brackets stored in potentially staining solutions. The sample were divided into four groups according to the commercial brand and stored in four different solutions (distilled water, cola soda, coffee and mouthrinse) at 37°C for 14 days. Possible color changes measured according to the CIE L*a*b* color system with a spectrophotometer at five intervals of time after storage. The statistical analysis was carried out using ANOVA to 1%, Tukey's tests and decomposition of interactions with a significance level of 5%.The color changes were dependent on the solution, storage time and the brand of brackets. The largest color changes were observed in the G3, followed by G2, G1/G4. The esthetic brackets do not present satisfactory and stable chromatic behavior.
Resumo:
1024x768 This research aimed to investigate possible differences in values of longitudinal modulus of elasticity for wood species usually employed for structural purposes, as Castanheira (Bertholletia excelsa), Cambará (Erisma uncinatum), Cumaru (Dipteryx odorata), Jatobá (Hymenaea stilbocarpa), Garapa (Apuleia leiocarpa) and Peroba Rosa (Aspidosperma polyneuron), obtained from compression and tension parallel to grain, and static bending tests. Recommendations of the Brazilian standard ABNT NBR 7190:1997, Annex B, were followed. Statistical analysis results for the cited properties, had equivalent averages for the six wood species analyzed. This confirms that any of the three tests can be used to obtain the longitudinal elastic modulus and which could avoid the necessity of evaluating stiffness values for wood by more than one kind of mechanical test. Normal 0 21 false false false PT-BR X-NONE X-NONE /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Tabela normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;}
Resumo:
Study Objective: To evaluate the diagnostic accuracy of transvaginal ultrasound and office hysteroscopy in the differentiation between endometrial polyps and endometrial adenocarcinoma. Design: This is a prospective 100 women longitudinal study, 24 to 80 years, submitted to hysteroscopic polypectomy (n = 80) or surgery due to endometrial adenocarcinoma (n = 20), from january 2010 to December 2011. Clinical, ultrasonographic and hysteroscopic parameters were analyzed and compared with histopathologic find. Statistical analysis were performed utilizing the Tukey, Kruskal-Wallis, Dunn and Mann-Whitney test, with a confidence interval of 95% and p\0, 05 statiscally significant. Setting: Botucatu Medical School. Intervention: Prospective analysis of clinical, ultrasonographic and hysteroscopic parameters in patients with diagnosis suspected of endometrial polyps and adenocarcinoma of endometrium were performed. According to the diagnosis, hysteroscopic polypectomy or pan hysterectomy with lymph node sampling was realized. After the surgery and histopathological study, statistical analysis of parameters was performed and the results were compared between groups. It was Research Ethics Committee approved. Measurements and Main Results: There were no differences between age, BMI, menopause, TH use and associated diseases among groups. The main symptom of endometrial cancer was the postmenopausal bleeding, affecting 84,2% of women against 34,8% of polypectomy group. The majority of women with endometrial polyps were asymptomatic. Transvaginal ultrasonography showed no ability to differentiate cases of endometrial cancer compared with the cases of endometrial polyps, considering the presence of endometrial thickness and blood flow on color Doppler. Office hysteroscopy showed significant changes in 75% of the adenocarcinoma cases, especially the presence of diffuse hypervascularity with atypical vessels. Conclusion: Still remains an inability to establish clinical parameters and reliable ultrasound imaging to differentiate endometrial polyps and cancer of endometrium. Attention should be given to hysteroscopic exams presenting diffuse endometrial hypervascularization with architectural distortion of the vessels. The recommendation of our service remains the systematic removal of all endometrial polyps.
Resumo:
PURPOSE: To investigate the facial symmetry of high and low dose methotrexate (MTX) treated rats submitted to experimentally displaced mandibular condyle fracture through the recording of cephalometric measurements. METHODS: One hundred male Wistar rats underwent surgery using an experimental model of right condylar fracture. Animals were divided into four groups: A - saline solution (1mL/week); B - dexamethasone (DEX) (0,15mg/Kg); C - MTX low dose (3 mg/Kg/week); D - MTX high dose (30 mg/Kg). Animals were sacrificed at 1, 7, 15, 30 and 90 days postoperatively (n=5). Body weight was recorded. Specimens were submitted to axial radiographic incidence, and cephalometric mensurations were made using a computer system. Linear measurements of skull and mandible, as well as angular measurements of mandibular deviation were taken. Data were subjected to statistical analyses among the groups, periods of sacrifice and between the sides in each group (alpha=0.05). RESULTS: Animals regained body weight over time, except in group D. There was reduction in the mandibular length and also changes in the maxilla as well as progressive deviation in the mandible in relation to the skull basis in group D. CONCLUSION: Treatment with high dose methotrexate had deleterious effect on facial symmetry of rats submitted to experimentally displaced condylar process fracture.
Resumo:
The aims of this in vivo study were to compare the effectiveness and color stability of at-home and in-office bleaching techniques and to evaluate whether the use of light sources can alter bleaching results. According to preestablished criteria, 40 patients were selected and randomly divided into four groups according to bleaching treatment: (1) at-home bleaching with 10% carbamide peroxide, (2) in-office bleaching with 35% hydrogen peroxide (HP) without a light source, (3) in-office bleaching with 35% HP with quartz-tungsten-halogen light, and (4) in-office bleaching with 35% HP with a light-emitting diode/laser. Tooth shade was evaluated using the VITA Classical Shade Guide before bleaching as well as after the first and third weeks of bleaching. Tooth shade was evaluated again using the same guide 1 and 6 months after the completion of treatment. The shade guide was arranged to yield scores that were used for statistical comparison. Statistical analysis using the Kruskal-Wallis test showed no significant differences among the groups for any time point (P > .01). There was no color rebound in any of the groups. The bleaching techniques tested were equally effective. Light sources are unnecessary to bleach teeth. (Int J Periodontics Restorative Dent 2012;32:303-309.)