997 resultados para Spinal Stenosis - diagnosis


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This review aims to identify strategies to optimise radiography practice using digital technologies, for full spine studies on paediatrics focusing particularly on methods used to diagnose and measure severity of spinal curvatures. The literature search was performed on different databases (PubMed, Google Scholar and ScienceDirect) and relevant websites (e.g., American College of Radiology and International Commission on Radiological Protection) to identify guidelines and recent studies focused on dose optimisation in paediatrics using digital technologies. Plain radiography was identified as the most accurate method. The American College of Radiology (ACR) and European Commission (EC) provided two guidelines that were identified as the most relevant to the subject. The ACR guidelines were updated in 2014; however these guidelines do not provide detailed guidance on technical exposure parameters. The EC guidelines are more complete but are dedicated to screen film systems. Other studies provided reviews on the several exposure parameters that should be included for optimisation, such as tube current, tube voltage and source-to-image distance; however, only explored few of these parameters and not all of them together. One publication explored all parameters together but this was for adults only. Due to lack of literature on exposure parameters for paediatrics, more research is required to guide and harmonise practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: Optimise a set of exposure factors, with the lowest effective dose, to delineate spinal curvature with the modified Cobb method in a full spine using computed radiography (CR) for a 5-year-old paediatric anthropomorphic phantom. Methods: Images were acquired by varying a set of parameters: positions (antero-posterior (AP), posteroanterior (PA) and lateral), kilo-voltage peak (kVp) (66-90), source-to-image distance (SID) (150 to 200cm), broad focus and the use of a grid (grid in/out) to analyse the impact on E and image quality (IQ). IQ was analysed applying two approaches: objective [contrast-to-noise-ratio/(CNR] and perceptual, using 5 observers. Monte-Carlo modelling was used for dose estimation. Cohen’s Kappa coefficient was used to calculate inter-observer-variability. The angle was measured using Cobb’s method on lateral projections under different imaging conditions. Results: PA promoted the lowest effective dose (0.013 mSv) compared to AP (0.048 mSv) and lateral (0.025 mSv). The exposure parameters that allowed lower dose were 200cm SID, 90 kVp, broad focus and grid out for paediatrics using an Agfa CR system. Thirty-seven images were assessed for IQ and thirty-two were classified adequate. Cobb angle measurements varied between 16°±2.9 and 19.9°±0.9. Conclusion: Cobb angle measurements can be performed using the lowest dose with a low contrast-tonoise ratio. The variation on measurements for this was ±2.9° and this is within the range of acceptable clinical error without impact on clinical diagnosis. Further work is recommended on improvement to the sample size and a more robust perceptual IQ assessment protocol for observers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Information obtained from the routine application of hydatid immunodiagnostic techniques in different clinical situations over a seven-year period is presented. The Immunoelectrophoresis test was used until it was replaced by the simpler, more sensitive and equally specific arc 5 double diffusion (DD5) test. Examination of sera from 1,888 patients with signs and/or symptoms compatible with hydatid disease revealed that the presurgical confirmation of Echinococcus granulosus infection is only obtained by detection of anti-antigen 5 antibodies. The latter were not found in 1,539 presumptive hydatidosis patients whose definitive diagnoses corresponded to other disease conditions. However, false positive latex agglutination test results were obtained in two cases. In all patients whose preoperative serum showed three or more uncharacteristic bands in the absence of anti-antigen 5 antibodies, hydatid cysts were found sur gically. DD5 testing of a fluid sample collected by puncture established its hydatid etiology. Post-operative monitoring of hydatidosis patients demonstrated that persistence of DD5-positivity two years after surgery established the presence of other cysts. Further evidence was obtained in patients with hydatid cysts in intrathoracic, abdominal or other locations associating cyst membrane integrity, antigen release and immunodiagnostic test positivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Twenty patients with prolonged septicemic salmonellosis (Group 1) and 20 with schistosomiasis mansoni (Group 2) were selected for this study. In both groups, the Widal test was done using antigens of the sample Ty 901 (S. typhi). The test was also applied in 6 group 1 patients with antigens prepared from salmonellae isolated from these patients (autoantigens). Titres over 1:200 were considered significant. Ten group 1 patients (50%) were positive for antigen "H" and 5 (25%) were positive for antigen "O". Three patients with negative "H" and "O" reactions became positive with high titres when using autoantigens. Two other cases maintained the same positive titres and one case showed a fourfold increase in titres when the test was done 'with antigens of the Salmonella isolated. The Widal test was positive in most patients infected with group D Salmonellae. Considering titres above 1:200, all cases were negative in Group 2. The authors conclude that the Widal test has low positivity in prolonged septicemic salmonellosis. The test may be valuable in the diagnosis of this disease when using S. paratyphi "A" and "B" antigens and a mixture of Salmonella antigens taken from other groups.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The latest medical diagnosis devices enable the performance of e-diagnosis making the access to these services easier, faster and available in remote areas. However this imposes new communications and data interchange challenges. In this paper a new XML based format for storing cardiac signals and related information is presented. The proposed structure encompasses data acquisition devices, patient information, data description, pathological diagnosis and waveform annotation. When compared with similar purpose formats several advantages arise. Besides the full integrated data model it may also be noted the available geographical references for e-diagnosis, the multi stream data description, the ability to handle several simultaneous devices, the possibility of independent waveform annotation and a HL7 compliant structure for common contents. These features represent an enhanced integration with existent systems and an improved flexibility for cardiac data representation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A serologic study was undertaken in a group of 43 patients with active paracoccidioidomycosis who were treated in the same form (ketoconazole), for identical periods of time (6 months), and folio wed-up for various periods posttherapy. The tests employed were agar gel immunodiffusion (AGID) and complement fixation (FC). Also studied were 50 sera from patients with proven histoplasmosis and pulmonary aspergilloma, 30 patients with culturaly proven tuberculosis as well as 92 specimens from healthy individuals, residents in the endemic area for paracoccidioidomycosis. A single lot of yeast filtrate antigen was used throughout the study. The value of each test was measured according to GALEN and GAMBINO6. Both tests were highly sensitive, 89 and 93% respectively. Regarding their specificity, the AGID was totally specific while the CF exhibited 96.6% and 97% specificity in front of tuberculosis patients and healthy individuals respectively and 82% in comparison with patients with other mycoses. The concept of predictive value, that is, the certainty one has in accepting a positive test as diagnostic of paracoccidioidomycosis, favored the AGID procedure (100%) over the CF test. The latter could sort out with 93% certainty a patient with paracoccidioidomycosis among a group of healthy individuals and with 97.5% in the case of TB patients; when the group in question was composed by individuals with other deep mycoses, such certainty was lower (81%). The above results indicate that both the AGID and the CF tests furnish results of high confidence; one should not relay, however, in the CF alone as a means to establish the specific diagnosis of paracoccidioidomycosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lectins were labeled with fluorescein and tried as conjugates in the immunofluorescence (IP) test for the detection of IgM antibodies to T. gondii, in the diagnosis of acute toxoplasmosis. This approach was an attempt to find alternative reagents for anti-human IgM fluorescent conjugates (AHIgMFC), which contain quite frequently anaibcdies to toxoplasma, as contaminants, due to natural T. gondii infections among animals used for imunization. Lentil (Lens culinaris) lectin fluorescence conjugates (LcFC) provided most satisfactory results. The evaluation of LcFC carried out in a total of 179 sera from patients with acute and chronic toxoplasmosis, with non-related infections or healthy subjects, gave high values of relative efficiency, co-positivity and co-negativity indices, respectively 0.989, 0.969 and 1.000, in reference to the conventional AHIgMFC. Moreover, three batches of LcFC successively prepared gave reproducible test results. The advantage of LcFC as an alternative reagent for the serodiagnosis of acute toxoplasmosis is supported by practical aspects of its preparation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Urinary tract infection (UTI) is one of the most prevalent pathologies in developed countries, particularly in women, characterized by the presence of bacterial growth in any part of the urinary system. Currently, urine culture is considered the gold standard method for the diagnosis of UTI. However, this method has several disadvantages including the time necessary for obtaining the results and the associated high costs. Therefore, it is important to evaluate new efficient and valuable methods for the diagnosis of these infections. Objectives: Presently, dipsticks are considered a possible valuable alternative to urine culture. This method has very low costs associated and the results can be obtained in few minutes. Here we aim to compare the sensibility, specificity, predictive value of a positive test and a negative test of both methods in order to determine the efficiency of the test strips method and also to characterize the microorganism more frequently isolated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A total of 138 patients with the age of 4 months to 57 years were attended in different hospitals of São Paulo State with aseptic meningitis. A probable new agent was isolated from the cerebrospinal fluid of 35 of 53 specimens examined. Replication of the agent with similar characteristics was detected by CPE produced in the MDCK cell line. Virus-like particles measuring about 40 nm in diameter were observed by negative staining electron microscopy. No hemaglutinating activity was detected at pH 7.2 by using either human, guinea pig, chicken and at pH ranged 6.0 - 7.2 with goose red blood cells. The agent was not pathogenic to newborn or adult mice. Virus infectivity as measured by CPE was sensitive to chloroform and not inhibited by BuDR, suggesting that agent is an enveloped virus with RNA genome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sensitivity, specificity and positive predictive values of selected clinical signs and symptoms in the diagnosis of Schistosoma mansoni infection were evaluated in 403 individuals (69% of inhabitants over 1 year of age) in an endemic area in Brazil (Divino). Highest sensitivity (13%) was found for blood in stools. Specificity over 90% was found for blood in stools, palpable liver with normal consistency and palpable hardened liver at middle clavicular (MCL) or middle sternal lines (MSL). Hardened liver at MSL (83%) or MCL (75%), and blood in stools (78%) presented higher positive predictive values for S. mansoni infection, while palpable liver with normal consistency at MCL (45%) or MSL (48%) presented smaller values. Enlarged liver without specification of its consistency has been traditionally used as an indicator of the infection in areas where malaria or Kalazar are not endemic. Our results demonstrate that the probability that a person with blood in stools or hardened palpable liver is infected is higher than among those with palpable liver with normal consistency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Helicobacter pylori was investigated in 189 patients for culture, microscopic visualization of campylobacter-like organisms (CLO) and a ten minute urease test. In 136 (72%) the bacteria was isolated, and in 98 of them CLO were histologically detected. Specificity, sensitivity, positive and negative predictive values of microscopic visualization of CLO were: 0.77, 0.73, 0.97 and 0.51, respectively; 98 culture-positive patients were urease test positive. Specificity, sensitivity, positive and negative predictive values of the urease test were: 0.83, 0.72, 0.92 and 0.54, respectively. Comparing the urease test with culture of H. pylori combined with microscopic visualization of CLO, its specificity, sensitivity, positive and negative predictive values were: 0.95, 0.71, 0.98 and 0.48, respectively. Probably, these values are not real, since bacteria different from H. pylori could be misclassified as CLO.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work reports on the results of double immunodiffusion (ID), counterimmunoelectrophoresis (CIE), complement fixation (CF) and indirect immunofluorescence (IIF) techniques in the serodiagnosis of paracoccidioidomycosis. The study was undertaken on four groups of individuals: 46 patients with untreated paracoccidioidomycosis, 22 patients with other deep mycoses, 30 with other infectious diseases (tuberculosis and cutaneous leishmaniasis) and 47 blood donors as negative controls. Data were obtained using Paracoccidioides brasiliensis antigens, i.e.,a yeast culture filtrate for ID, CIE and CF, and a yeast cell suspension for IIF. The sensitivity, specificity and efficiency values were measured according to GALEN & GAMBINO8.The gel precipitation tests (ID and CIE) showed the greatest sensitivity (91.3 and 95.6%, respectively), maximum specificity (100%) and the highest efficiency values when compared to the CF and IIF tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The dot-enzyme-linked immunosorbent assay (dot-ELISA) was standardized using somatic (S) and excretory-secretory (ES) antigens of Toxocara-canis for the detection of specific antibodies in 22 serum samples from children aged 1 to 15 years, with clinical signs of toxocariasis. Fourteen serum samples from apparently normal individuals and 28 sera from patients with other pathologies were used as controls. All samples were used before and after absorption with Ascaris suum extract. When the results were evaluated in comparison with ELISA, the two tests were found to have similar sensitivity, but dot-ELISA was found to be more specific in the presence of the two antigens studied. Dot-ELISA proved to be effective for the diagnosis of human toxocariasis, presenting advantages in terms of yield, stability, time and ease of execution and low cost.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

From each of a group of 217 adult males selected through enzyme-immunoassay or skin-test (Group A), six stool samples were examined by both the Lutz/Hoffman, Pons & Janer (Lutz/HPJ) and Kato/Katz methods. In addition, one oogram of the rectal mucosa was performed. By these methods, schistosomiasis was detected in 44.7%, 47.5% and 40.1% of the individuals respectively. To evaluate the methods in the assessment of cure, the last 40 patients from group A, treated with a single oral dose of oxamniquine at 15 mg/kg were followed up for six months (Group B). The criteria for parasitological cure included three stool examinations by Kato/Katz and Lutz/HPJ methods, one, three and six months post-treatment and a rectal biopsy between the fourth and sixth months post-treatment. The examinations were negative in 87.5%, 90% and 95% of the patients, respectively. The efficacy of oxamniquine was 82.5% when the three methods were considered together and there was no statistically significant difference between the sensitivity of the individual methods.