999 resultados para Soluções de reidratação


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The extract of stevia leaves (Stevia rebaudiana Bertoni) is the only sweetener utilized in sucrose substitution which can be produced totally in Brazil. The objective of this study, was determine the temporal characteristic of sweet and bitter taste of stevia and compare with sucrose at 3 and 10% in the same equi-sweet. The time-intensity curves (T-I) for each substance were collected through the software Sistema de Coleta de Dados Tempo-Intensidade - SCDTI for Windows, where the judges recorded through of mouse the perception of each stimuli inside function of time, for each sample. The parameters of T-I curves collected were: time for intensity maxim (TImax), intensity maxim (Imax), time of decay (Td), time of plato (Platô), area under curve (Area) and total time of stimuli duration (Ttot). The parameters Td, Ttot, Area e Plato of T-I curves, for stimuli sweet in both sweetness level, were significativelly superior for stevia, while Timax e Imax were significativelly inferior (p£0,05), at differences between value for both substances were superior DESS at 10%. Sucrose didn?t present any record for simuli bitter as 3 as 10%, while stevia presented a characteristic T-I curve with intensity and total time of stimuli duration dependent of concentration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To compare intraocular pressure (IOP) rise in normal individuals and primary open-angle glaucoma patients and the safety and efficacy of ibopamine eye drops in different concentrations as a provocative test for glaucoma. METHODS: Glaucoma patients underwent (same eye) the ibopamine provocative test with two concentrations, 1% and 2%, in a random sequence at least 3 weeks apart, but not more than 3 months. The normal individuals were randomly submitted to one of the concentrations of ibopamine (1% and 2%). The test was considered positive if there was an IOP rise greater than 3 or 4 mmHg at 30 or 45 minutes to test which subset of the test has the best sensitivity (Se)/specificity (Sp). RESULTS: There was no statistically significant difference in any of the IOP measurements, comparing 1% with 2% ibopamine. The IOP was significantly higher at 30 and 45 minutes with both concentrations (p<0.001). The best sensitivity/specificity ratio was achieved with the cutoff point set as greater than 3 mmHg at 45 minutes with 2% ibopamine (area under the ROC curve: 0.864, Se: 84.6%; Sp:73.3%). All patients described a slight burning after ibopamine's instillation. CONCLUSION: 2% ibopamine is recommended as a provocative test for glaucoma. Because both concentrations have similar ability to rise IOP, 1% ibopamine may be used to treat ocular hypotony.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To compare the 2% ibopamine provocative test with the water drinking test as a provocative test for glaucoma. METHODS: Primary open-angle glaucoma patients and normal individuals were selected from CEROF-Universidade Federal de Goiânia UFG, and underwent the 2% ibopamine provocative test and the water drinking test in a randomized fashion, at least 1 week apart. Intraocular pressure (IOP) before and after both tests, Bland-Altman graph, sensitivity and specificity (as mesured by ROC curves) were obtained for both methods. RESULTS: Forty-seven eyes from 25 patients were included (27 eyes from 15 glaucoma patients and 20 eyes from 10 normal individuals), with a mean age of 54.2 ± 12.7 years. The mean MD of glaucoma patients was -2.8 ± 2.11 dB. There was no statistically difference in the baseline IOP (p=0.8) comparing glaucoma patients, but positive after the provocative tests (p=0.03), and in the IOP variation (4.4 ± 1.3 mmHg for ibopamine and 3.2 ± 2.2 mmHg for water drinking test, p=0.01). There was no difference in all studied parameters for normal individuals. The Bland-Altman graph showed high dispersion comparing both methods. The areas under the ROC curve were 0.987 for the ibopamine provocative test, and 0.807 for the water-drinking test. CONCLUSION: In this selected subgroup of glaucoma patients with early visual field defect, the ibopamine provocative test has shown better sensitivity/specificity than the water drinking test.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To report a case of Nocardia asteroides scleritis in a patient without risk factors for infeccious scleritis. METHODS: A 38-year old woman was initially examined for pain, discharge, photophobia of 1 month duration in her right eye. Her medical and ophthalmological history were unremarkable. The results of laboratory tests were normal. Surgical debridement of necrotic tissue was performed and material was sent for biopsy and culture confirmed as Nocardia asteroides. Treatment consisted of amikacin eyedrops, and systemic trimethropim-sulfamethoxazole. The infection resolved leaving scleral thinning and a subconjunctival fibrovascular scar. Best corrected visual acuity two months after referral had improved to LE, 20/20. CONCLUSION: Prompt evaluation and treatment is essential for successful management of Nocardia asteroides infectious scleritis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evaluate the need for artificial tears by glaucoma patients under topical hypotensive treatment and to identify risk factors associated with it. METHODS: The charts of 175 glaucoma patients under medical treatment and 175 age-matched controls were reviewed. Age, gender, use of artificial tears, number of glaucoma medications used, and duration of treatment were recorded. RESULTS: Significantly more glaucoma patients (n=92; 52.6%) used artificial tears compared to age-matched controls (n=31; 17.7%) (p<0.001). Significantly more females (n=81; 39%) than males (n=42; 28.9%) used artificial tears (p=0.036). When the whole population was analyzed, female gender (OR=1.63) and the presence of glaucoma (OR= 5.14) were risk factors for the use of artificial tears (p<0.05). When the glaucoma population was analyzed, female gender (OR=2.57), number of medications >2 (OR=1.92), and duration of treatment >5 years (OR=2.93) were risk factors for the use of artificial tears (p<0.05). CONCLUSIONS: Topical treatment with antiglaucoma medication is a risk factor for the use of artificial tears. Female gender and long-term treatment of glaucoma with two or more medications were aggravating factors for the need for artificial tears.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evaluate the ocular surface toxicity of two nitric oxide donors in ex vivo and in vivo animal models: S-nitrosoglutathione (GSNO) and S-nitroso-N-acetylcysteine (SNAC) in a hydroxypropyl methylcellulose (HPMC) matrix at final concentrations 1.0 and 10.0 mM. METHODS: Ex vivo GSNO and SNAC toxicities were clinically and histologically analyzed using freshly excised pig eyeballs. In vivo experiments were performed with 20 albino rabbits which were randomized into 4 groups (5 animals each): Groups 1 and 2 received instillations of 150 µL of aqueous HPMC solution containing GSNO 1.0 and 10.0 mM, respectively, in one of the eyes; Groups 3 and 4 received instillations of 150 µL of aqueous HPMC solution-containing SNAC 1.0 and 10.0 mM, respectively, in one of the eyes. The contralateral eyes in each group received aqueous HPMC as a control. All animals underwent clinical evaluation on a slit lamp and the eyes were scored according to a modified Draize eye test and were histologically analyzed. RESULTS: Pig eyeballs showed no signs of perforation, erosion, corneal opacity or other gross damage. These findings were confirmed by histological analysis. There was no difference between control and treated rabbit eyes according to the Draize eye test score in all groups (p>0.05). All formulations showed a mean score under 1 and were classified as non-irritating. There was no evidence of tissue toxicity in the histological analysis in all animals. CONCLUSION: Aqueous HPMC solutions containing GSNO and SNAC at concentrations up to 10.0 mM do not induce ocular irritation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas. Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas. Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas. Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este artigo tem por objetivo apresentar as ações desenvolvidas na construção do modelo de atenção em saúde no Distrito Especial Indígena - Xingu (DSEI-Xingu), mais especificamente, na área de saúde bucal, com a efetiva parceria entre a Universidade Federal do Estado de São Paulo (UNIFESP), Faculdade de Odontologia de Ribeirão Preto - Universidade de São Paulo (FORP-USP) e a Colgate®, que permitiu a construção social da práxis em saúde no Médio e Baixo Xingu. Ao longo da história, o DSEI "Espaço Social" é onde as comunidades se constituem e, por meio do processo social de produção, cria acessos diferenciados aos bens de consumo, além de formar a base para a organização dos serviços de atenção à saúde dos povos indígenas. Para o DSEI-Xingu, são pontos básicos o estabelecimento de parcerias institucionais e a participação efetiva dos povos indígenas na gestão da saúde em seu território. Estruturado no planejamento baseado em problemas sentidos pela população, utiliza-se da construção coletiva de redes explicativas, apontando soluções em vários planos com abordagem intersetorial. É através da observação dos indicadores de saúde que se torna perceptível a assimilação das comunidades indígenas com o recente modelo de atenção básica à saúde bucal, uma vez que constantemente está sendo adaptado à cultura, à tradição e às singularidades desses povos indígenas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Removable partial dentures (RPD) demand specific hygienic cleaning and the combination of brushing with immersion in chemical solutions has been the most recommended method for control of biofilm. However, the effect of the cleansers on metallic components has not been widely investigated. This study evaluated the effect of different cleansers on the surface of RPD. Five disc specimens (12 mm x 3 mm metallic disc centered in a 38 x 18 x 4 mm mould filled with resin) were obtained for each experimental situation: 6 solutions [Periogard (PE), Cepacol (CE), Corega Tabs (CT), Medical Interporous (MI), Polident (PO), 0.05% sodium hypochlorite (NaOCl), and distilled water (DW) control] and 2 Co-Cr alloys [DeguDent (DD) and VeraPDI (VPDI)] were used for each experimental situation. A 180-day immersion was simulated and the measurements of roughness (Ra, µm) of metal and resin were analyzed using 2-way ANOVA and Tukey’s test. The surface changes and tarnishes were examined with a scanning electronic microscopy (SEM). In addition, energy dispersive x-ray spectrometry (EDS) analysis was carried out at representative areas. Visually, NaOCl and MI specimens presented surface tarnishes. The roughness of materials was not affected by the solutions (p>0.05). SEM images showed that NaOCl and MI provided surface changes. EDS analysis revealed the presence of oxygen for specimens in contact with both MI and NaOCl solutions, which might suggest that the two solutions promoted the oxidation of the surfaces, thus leading to spot corrosion. Within the limitations of this study, it may be concluded that the NaOCl and MI may not be suitable for cleaning of RPD.