855 resultados para Six sigma (Quality control standard)
Resumo:
In this study, a quality assessment method based on sampling of primary laser inventory units (microsegments) was analysed. The accuracy of a laser inventory carried out in Kuhmo was analysed as a case study. Field sample plots were measured on the sampled microsegments in the Kuhmo inventory area. Two main questions were considered. Did the ALS based inventory meet the accuracy requirements set for the provider and how should a reliable, cost-efficient and independent quality assessment be undertaken. The agreement between control measurement and ALS based inventory was analysed in four ways: 1) The root mean squared errors (RMSEs) and bias were calculated. 2) Scatter plots with 95% confidence intervals were plotted and the placing of identity lines was checked. 3) Bland-Altman plots were drawn so that the mean difference of attributes between the control method and ALS-method was calculated and plotted against average value of attributes. 4) The tolerance limits were defined and combined with Bland-Altman plots. The RMSE values were compared to a reference study from which the accuracy requirements had been set to the service provider. The accuracy requirements in Kuhmo were achieved, however comparison of RMSE values proved to be difficult. Field control measurements are costly and time-consuming, but they are considered to be robust. However, control measurements might include errors, which are difficult to take into account. Using the Bland-Altman plots none of the compared methods are considered to be completely exact, so this offers a fair way to interpret results of assessment. The tolerance limits to be set on order combined with Bland-Altman plots were suggested to be taken in practise. In addition, bias should be calculated for total area. Some other approaches for quality control were briefly examined. No method was found to fulfil all the required demands of statistical reliability, cost-efficiency, time efficiency, simplicity and speed of implementation. Some benefits and shortcomings of the studied methods were discussed.
Resumo:
Quantification of pyridoxal-5´-phosphate (PLP) in biological samples is challenging due to the presence of endogenous PLP in matrices used for preparation of calibrators and quality control samples (QCs). Hence, we have developed an LC-MS/MS method for accurate and precise measurement of the concentrations of PLP in samples (20 µL) of human whole blood that addresses this issue by using a surrogate matrix and minimizing the matrix effect. We used a surrogate matrix comprising 2% bovine serum albumin (BSA) in phosphate buffer saline (PBS) for making calibrators, QCs and the concentrations were adjusted to include the endogenous PLP concentrations in the surrogate matrix according to the method of standard addition. PLP was separated from the other components of the sample matrix using protein precipitation with trichloroacetic acid 10% w/v. After centrifugation, supernatant were injected directly into the LC-MS/MS system. Calibration curves were linear and recovery was > 92%. QCs were accurate, precise, stable for four freeze-thaw cycles, and following storage at room temperature for 17h or at -80 °C for 3 months. There was no significant matrix effect using 9 different individual human blood samples. Our novel LC-MS/MS method has satisfied all of the criteria specified in the 2012 EMEA guideline on bioanalytical method validation.
Resumo:
Data assimilation provides an initial atmospheric state, called the analysis, for Numerical Weather Prediction (NWP). This analysis consists of pressure, temperature, wind, and humidity on a three-dimensional NWP model grid. Data assimilation blends meteorological observations with the NWP model in a statistically optimal way. The objective of this thesis is to describe methodological development carried out in order to allow data assimilation of ground-based measurements of the Global Positioning System (GPS) into the High Resolution Limited Area Model (HIRLAM) NWP system. Geodetic processing produces observations of tropospheric delay. These observations can be processed either for vertical columns at each GPS receiver station, or for the individual propagation paths of the microwave signals. These alternative processing methods result in Zenith Total Delay (ZTD) and Slant Delay (SD) observations, respectively. ZTD and SD observations are of use in the analysis of atmospheric humidity. A method is introduced for estimation of the horizontal error covariance of ZTD observations. The method makes use of observation minus model background (OmB) sequences of ZTD and conventional observations. It is demonstrated that the ZTD observation error covariance is relatively large in station separations shorter than 200 km, but non-zero covariances also appear at considerably larger station separations. The relatively low density of radiosonde observing stations limits the ability of the proposed estimation method to resolve the shortest length-scales of error covariance. SD observations are shown to contain a statistically significant signal on the asymmetry of the atmospheric humidity field. However, the asymmetric component of SD is found to be nearly always smaller than the standard deviation of the SD observation error. SD observation modelling is described in detail, and other issues relating to SD data assimilation are also discussed. These include the determination of error statistics, the tuning of observation quality control and allowing the taking into account of local observation error correlation. The experiments made show that the data assimilation system is able to retrieve the asymmetric information content of hypothetical SD observations at a single receiver station. Moreover, the impact of real SD observations on humidity analysis is comparable to that of other observing systems.
Resumo:
The Earth's ecosystems are protected from the dangerous part of the solar ultraviolet (UV) radiation by stratospheric ozone, which absorbs most of the harmful UV wavelengths. Severe depletion of stratospheric ozone has been observed in the Antarctic region, and to a lesser extent in the Arctic and midlatitudes. Concern about the effects of increasing UV radiation on human beings and the natural environment has led to ground based monitoring of UV radiation. In order to achieve high-quality UV time series for scientific analyses, proper quality control (QC) and quality assurance (QA) procedures have to be followed. In this work, practices of QC and QA are developed for Brewer spectroradiometers and NILU-UV multifilter radiometers, which measure in the Arctic and Antarctic regions, respectively. These practices are applicable to other UV instruments as well. The spectral features and the effect of different factors affecting UV radiation were studied for the spectral UV time series at Sodankylä. The QA of the Finnish Meteorological Institute's (FMI) two Brewer spectroradiometers included daily maintenance, laboratory characterizations, the calculation of long-term spectral responsivity, data processing and quality assessment. New methods for the cosine correction, the temperature correction and the calculation of long-term changes of spectral responsivity were developed. Reconstructed UV irradiances were used as a QA tool for spectroradiometer data. The actual cosine correction factor was found to vary between 1.08-1.12 and 1.08-1.13. The temperature characterization showed a linear temperature dependence between the instrument's internal temperature and the photon counts per cycle. Both Brewers have participated in international spectroradiometer comparisons and have shown good stability. The differences between the Brewers and the portable reference spectroradiometer QASUME have been within 5% during 2002-2010. The features of the spectral UV radiation time series at Sodankylä were analysed for the time period 1990-2001. No statistically significant long-term changes in UV irradiances were found, and the results were strongly dependent on the time period studied. Ozone was the dominant factor affecting UV radiation during the springtime, whereas clouds played a more important role during the summertime. During this work, the Antarctic NILU-UV multifilter radiometer network was established by the Instituto Nacional de Meteorogía (INM) as a joint Spanish-Argentinian-Finnish cooperation project. As part of this work, the QC/QA practices of the network were developed. They included training of the operators, daily maintenance, regular lamp tests and solar comparisons with the travelling reference instrument. Drifts of up to 35% in the sensitivity of the channels of the NILU-UV multifilter radiometers were found during the first four years of operation. This work emphasized the importance of proper QC/QA, including regular lamp tests, for the multifilter radiometers also. The effect of the drifts were corrected by a method scaling the site NILU-UV channels to those of the travelling reference NILU-UV. After correction, the mean ratios of erythemally-weighted UV dose rates measured during solar comparisons between the reference NILU-UV and the site NILU-UVs were 1.007±0.011 and 1.012±0.012 for Ushuaia and Marambio, respectively, when the solar zenith angle varied up to 80°. Solar comparisons between the NILU-UVs and spectroradiometers showed a ±5% difference near local noon time, which can be seen as proof of successful QC/QA procedures and transfer of irradiance scales. This work also showed that UV measurements made in the Arctic and Antarctic can be comparable with each other.
Resumo:
FTIR-spektroskopia (Fourier-muunnosinfrapunaspektroskopia) on nopea analyysimenetelmä. Fourier-laitteissa interferometrin käyttäminen mahdollistaa koko infrapunataajuusalueen mittaamisen muutamassa sekunnissa. ATR-liitännäisellä varustetun FTIR-spektrometrin käyttö ei edellytä juuri näytteen valmistusta ja siksi menetelmä on käytössä myös helppo. ATR-liitännäinen mahdollistaa myös monien erilaisten näytteiden analysoinnin. Infrapunaspektrin mittaaminen onnistuu myös sellaisista näytteistä, joille perinteisiä näytteenvalmistusmenetelmiä ei voida käyttää. FTIR-spektroskopian avulla saatu tieto yhdistetään usein tilastollisiin monimuuttuja-analyyseihin. Klusterianalyysin avulla voidaan spektreistä saatu tieto ryhmitellä samanlaisuuteen perustuen. Hierarkkisessa klusterianalyysissa objektien välinen samanlaisuus määritetään laskemalla niiden välinen etäisyys. Pääkomponenttianalyysin avulla vähennetään datan ulotteisuutta ja luodaan uusia korreloimattomia pääkomponentteja. Pääkomponenttien tulee säilyttää mahdollisimman suuri määrä alkuperäisen datan variaatiosta. FTIR-spektroskopian ja monimuuttujamenetelmien sovellusmahdollisuuksia on tutkittu paljon. Elintarviketeollisuudessa sen soveltuvuutta esimerkiksi laadun valvontaan on tutkittu. Menetelmää on käytetty myös haihtuvien öljyjen kemiallisten koostumusten tunnistukseen sekä öljykasvien kemotyyppien havaitsemiseen. Tässä tutkimuksessa arvioitiin menetelmän käyttöä suoputken uutenäytteiden luokittelussa. Tutkimuksessa suoputken eri kasvinosien uutenäytteiden FTIR-spektrejä vertailtiin valikoiduista puhdasaineista mitattuihin FTIR-spektreihin. Puhdasaineiden FTIR-spektreistä tunnistettiin niiden tyypilliset absorptiovyöhykkeet. Furanokumariinien spektrien intensiivisten vyöhykkeiden aaltolukualueet valittiin monimuuttuja-analyyseihin. Monimuuttuja-analyysit tehtiin myös IR-spektrin sormenjälkialueelta aaltolukualueelta 1785-725 cm-1. Uutenäytteitä pyrittiin luokittelemaan niiden keräyspaikan ja kumariinipitoisuuden mukaan. Keräyspaikan mukaan ryhmittymistä oli havaittavissa, mikä selittyi vyöhykkeiden aaltolukualueiden mukaan tehdyissä analyyseissa pääosin kumariinipitoisuuksilla. Näissä analyyseissa uutenäytteet pääosin ryhmittyivät ja erottuivat kokonaiskumariinipitoisuuksien mukaan. Myös aaltolukualueen 1785-725 cm-1 analyyseissa havaittiin keräyspaikan mukaan ryhmittymistä, mitä kumariinipitoisuudet eivät kuitenkaan selittäneet. Näihin ryhmittymisiin vaikuttivat mahdollisesti muiden yhdisteiden samanlaiset pitoisuudet näytteissä. Analyyseissa käytettiin myös muita aaltolukualueita, mutta tulokset eivät juuri poikenneet aiemmista. 2. kertaluvun derivaattaspektrien monimuuttuja-analyysit sormenjälkialueelta eivät myöskään muuttaneet tuloksia havaittavasti. Jatkotutkimuksissa nyt käytettyä menetelmää on mahdollista edelleen kehittää esimerkiksi tutkimalla monimuuttuja-analyyseissa 2. kertaluvun derivaattaspektreistä suppeampia, tarkkaan valittuja aaltolukualueita.
Resumo:
The use of self-contained, low-maintenance sensor systems installed on commercial vessels is becoming an important monitoring and scientific tool in many regions around the world. These systems integrate data from meteorological and water quality sensors with GPS data into a data stream that is automatically transferred from ship to shore. To begin linking some of this developing expertise, the Alliance for Coastal Technologies (ACT) and the European Coastal and Ocean Observing Technology (ECOOT) organized a workshop on this topic in Southampton, United Kingdom, October 10-12, 2006. The participants included technology users, technology developers, and shipping representatives. They collaborated to identify sensors currently employed on integrated systems, users of this data, limitations associated with these systems, and ways to overcome these limitations. The group also identified additional technologies that could be employed on future systems and examined whether standard architectures and data protocols for integrated systems should be established. Participants at the workshop defined 17 different parameters currently being measured by integrated systems. They identified that diverse user groups utilize information from these systems from resource management agencies, such as the Environmental Protection Agency (EPA), to local tourism groups and educational organizations. Among the limitations identified were instrument compatibility and interoperability, data quality control and quality assurance, and sensor calibration andlor maintenance frequency. Standardization of these integrated systems was viewed to be both advantageous and disadvantageous; while participants believed that standardization could be beneficial on many levels, they also felt that users may be hesitant to purchase a suite of instruments from a single manufacturer; and that a "plug and play" system including sensors from multiple manufactures may be difficult to achieve. A priority recommendation and conclusion for the general integrated sensor system community was to provide vessel operators with real-time access to relevant data (e.g., ambient temperature and salinity to increase efficiency of water treatment systems and meteorological data for increased vessel safety and operating efficiency) for broader system value. Simplified data displays are also required for education and public outreach/awareness. Other key recommendations were to encourage the use of integrated sensor packages within observing systems such as 100s and EuroGOOS, identify additional customers of sensor system data, and publish results of previous work in peer-reviewed journals to increase agency and scientific awareness and confidence in the technology. Priority recommendations and conclusions for ACT entailed highlighting the value of integrated sensor systems for vessels of opportunity through articles in the popular press, and marine science. [PDF contains 28 pages]
Resumo:
Guided by experience and the theoretical development of hydrobiology, it can be considered that the main aim of water quality control should be the establishment of the rates of the self-purification process of water bodies which are capable of maintaining communities in a state of dynamic balance without changing the integrity of the ecosystem. Hence, general approaches in the elaboration of methods for hydrobiological control are based on the following principles: a. the balance of matter and energy in water bodies; b. the integrity of the ecosystem structure and of its separate components at all levels. Ecosystem analysis makes possible a revelation of the whole totality of factors which determine the anthropogenic evolution of a water body. This is necessary for the study of long-term changes in water bodies. The principles of ecosystem analysis of water bodies, together with the creation of their mathematical models, are important because, in future, with the transition of water demanding production into closed cycles of water supply, changes in water bodies will arise in the main through the influence of 'diffuse' pollution (from the atmosphere, with utilisation in transport etc.).
Resumo:
Diversos pesquisadores têm estudado o comportamento e o emprego de aduelas de concreto, que constituem as vigas segmentadas em sistemas estruturais, de maneira especial pontes e viadutos. Por esta razão, inúmeros trabalhos têm sido publicados nos últimos anos respaldados por testes experimentais e análises numéricas. O comportamento destas vigas contrasta com as clássicas vigas monolíticas em diversos aspectos, pois, a estrutura é composta de partes de elementos de concreto pré-moldado que, após serem posicionados no local definitivo, são protendidos. A protensão pode ser aderente ou não aderente. A principal vantagem deste sistema de construção é a rapidez e o alto controle de qualidade, por isso é largamente utilizado, havendo uma demanda de estudo de previsão do seu real comportamento No presente trabalho apresenta-se uma modelagem numérica via elementos finitos, para simular o comportamento de vigas compostas por aduelas justapostas sem material ligante entre as juntas. A protensão aplicada é aderente e a análise considera a não linearidade da região da junta. Assim sendo, o objetivo desta investigação é dar uma contribuição ao estudo do comportamento estrutural estático de vigas segmentadas, atentando para o comportamento das juntas, utilizando um programa comercial. Para o modelo são empregadas técnicas usuais de discretização, via método dos elementos finitos (MEF), por meio do programa de elementos finitos SAP2000[93]. O modelo proposto é constituído de elementos de placa próprios para concreto para representar a viga, a protensão é introduzida por meio de barras bidimensionais que transferem as tensões ao longo de seu comprimento e as juntas são implementadas utilizando elementos de contato. A analise é bidimensional e considera os efeitos das perdas de protensão. Este trabalho de pesquisa objetiva também o estudo de elementos de contato especialmente as características de deformação para esta ferramenta computacional. A definição dos parâmetros para o modelo foi feita com base em dados experimentais disponíveis na literatura. O modelo numérico foi calibrado e confrontado com resultados experimentais obtidos em ensaios de laboratório.
Resumo:
Nota técnica para el análisis de compuestos volátiles en fórmulas higiénicas
Resumo:
A presente dissertação visa analisar a importância da gestão dos resíduos sólidos industriais em uma indústria petroquímica e o uso da metodologia Seis Sigma na redução dos custos da qualidade associados à geração de resíduos sólidos e poluição ambiental. A Petroflex, fundada em 1962, situada em Campos Elíseos Duque de Caxias / RJ, é a maior fabricante de borracha sintética da América Latina e uma das primeiras empresas do Brasil e se certificar nas normas ISO. Os processos produtivos de obtenção da borracha sintética são potencialmente poluidores, todas as suas atividades provocam a geração de toneladas de resíduos sólidos. A Petroflex iniciou na década de 1990 seus esforços para reverter um quadro de degradação ambiental e uma cultura de desperdício. A partir de 2004, a Petroflex necessitou de uma nova concepção para priorização das suas ações e tomadas de decisões. A Metodologia Seis Sigma foi a escolhida para sustentar o novo salto de desenvolvimento da empresa e em 2008 a empresa alinhou a Seis Sigma ou Gerenciamento de Resíduos Sólidos. O uso da metodologia Seis Sigma, as ações tomadas e os resultados alcançados, bem como, a realização de um projeto em uma das unidades da Petroflex, que levou a criação de um manual de gestão de resíduos sólidos, serão apresentados nos capítulos dessa dissertação, que buscou pesquisas bibliográficas, eletrônicas e documentais para ilustrar os conceitos deste tema de grande importância para sociedade.
Resumo:
Fish processing and quality control in Malawi are still poorly developed. Traditional fish processing methods are widely employed resulting in considerable post-harvest losses. One of the major challenges to steady and sustainable development in fish processing and quality management is the lack of adequately trained personel. This is directly reflected in poor institutional capacity. This project analyses the situation in fish processing and quality management in Malawi to identify gaps that require improvement. Specifically, the project assesses the role of training institutions in Malawi in capacity building for fish processing and quality management. The institution under discussion in this project is the Aquaculture and Fisheries Science Department at Bunda College of Agriculture, Malawi which is responsible for training students in aquaculture and fisheries science at the undergraduate level.Improvement in the teaching of fish processing and quality management in the Department of Aquaculture and Fisheries Science was identified as the major gap requiring action. The current teaching syllabus was thus analysed to identify weak areas. In conclusion, the project developed (as the major output) a teaching handbook for the Department of Aquaculture and Fisheries Science.
Resumo:
The National Oceanic and Atmospheric Administration (NOAA), in cooperation with the New Jersey Marine Sciences Consortium (NJMSC), hosted a workshop at Rutgers University on 19-21 September 2005 to explore ways to link the U.S. Integrated Ocean Observing System (IOOS) to the emerging infrastructure of the National Water Quality Monitoring Network (NWQMN). Participating partners included the Mid-Atlantic Coastal Ocean Observing Regional Association, U.S. Geological Survey, Rutgers University Coastal Ocean Observing Laboratory, and the New Jersey Sea Grant College. The workshop was designed to highlight the importance of ecological and human health linkages in the movement of materials, nutrients, organisms and contaminants along the Delaware Bay watershed-estuary-coastal waters gradient (hereinafter, the “Delaware Bay Ecosystem [DBE]”), and to address specific water quality issues in the mid-Atlantic region, especially the area comprising the Delaware River drainage and near-shore waters. Attendees included federal, state and municipal officials, coastal managers, members of academic and research institutions, and industry representatives. The primary goal of the effort was to identify key management issues and related scientific questions that could be addressed by a comprehensive IOOS-NWQMN infrastructure (US Commission on Ocean Policy 2004; U.S. Ocean Action Plan 2004). At a minimum, cooperative efforts among the three federal agencies (NOAA, USGS and EPA) involved in water quality monitoring were required. Further and recommended by the U.S. Commission on Ocean Policy, outreach to states, regional organizations, and tribes was necessary to develop an efficient system of data gathering, quality assurance and quality control protocols, product development, and information dissemination.
Resumo:
The paper presents the results of a bacteriological survey carried out on 2,917 samples of frozen prawn, 55 samples of raw material, 35 samples of water, 4 samples of ice and 42 samples of various equipment used for processing. The survey covered a period of three years (1960-63) and comprised of samples collected from five of the leading processing factories in Cochin. Frozen products tested consisted of headless (marine and fresh water), peeled and deveined and cooked frozen samples. Statistical analysis of the data shows that there is no significant variation between samples and between factories with respect to product quality. The standard plate count varied between 1.0x10(4 superscript) and 1.0x10(6 superscript) per gram for headless and between 1.0x10(4 superscript) and 1.0x10(7 superscript) for peeled and deveined and cooked frozen samples. Majority of the samples had bacterial load well within the limits prescribed for such products.
Resumo:
随着化工行业的发展,大量有毒有害难降解有机物随工业废水的排放进入环境,这些物质能够在环境中长期存在、积累和扩散,通过食物链对动植物的生存及人类的健康造成不良影响。本文以苯酚、对氯硝基苯、氯苯和十六烷为模拟污染物,以前期研制的功能菌剂为对象,经过紫外线线诱变筛选出优于出发菌株的功能菌,对诱变后功能菌的理化性能进行了研究,对菌种进行了鉴定,在此基础上,就其相互之间的微生态关系进行研究,为混合发酵提供理论基础,并就其最佳发酵条件及发酵参数进行了研究,最后对发酵产品的性能进行了检测。目前,国内外有关功能菌剂的研究还存在多方面的不足,主要包括:①由于多菌种混合发酵过程较为复杂,各菌之间存在复杂的相互作用,影响因素较多,关于菌种之间的相互关系研究得很少,环境功能菌剂的发酵方法大多采用单独发酵后混合的方式。单独发酵对原材料、设备和能源的利用率较低,对于多菌种制剂发酵,在设备、能源和原材料的方面造成的浪费更大,将会大幅增加菌剂的生产成本,影响多菌种功能菌剂的发展;②功能菌剂生产过程的质量控制方面研究得较少;③功能菌剂产品的稳定性、抗冲击性能研究得较少,对环境微生物制剂的研究主要集中在菌种选育和培养条件优化方面。 通过本论文研究,得到以下主要结论。 (1)在紫外线诱变处理中,用紫外线对发生一定程度退化的出发菌株进行诱变处理后,六株具有高效降解性能的菌株被筛选出来,诱变筛选出的菌株形态和ERIC-PCR指纹图谱与出发菌株相比发生了明显改变;而且诱变后的菌株对目标难降解底物的降解能力均得到改善,其中,FPN、FCB、F14、FEm对目标底物的降解率提高了20%以上;诱变后菌株经过7次连续传代接种后,对目标难降解底物的降解率无显著变化,具有一定的遗传稳定性。并对诱变后的功能菌进行了初步的鉴定,这6株菌都分别是芽孢杆菌。 (2)对诱变后的功能菌相互之间的微生态关系进行了研究,通过抑菌实验、生长量以及基质消耗量的比较,确定它们之间的生长关系是无害共栖关系,可以进行混合发酵。 (3)对该功能菌剂进行发酵培养条件研究,结果表明发酵培养基的最佳成分(g/L):葡萄糖 31.0g/L、玉米粉10.0g/L、磷酸氢二钾1.0g/L、硫酸铵1.1g/L、硫酸镁0.55g/L。通过研究不同的培养条件对菌体生长和降解性能的影响,确定了最佳培养条件:培养基初始pH7.5;最适温度32℃;培养基装液量125mL(250 mL三角瓶),以及培养时间对降解性能的影响,培养20 h的产物对降解最为有利。通过研究添加不同目标污染物对菌体生长和降解性能的影响,确定了添加目标污染物的最佳量以及最佳时间:苯酚投加量:1.125 g/L,对氯硝基苯投加量:0.1 g/L;最佳投加时间为发酵培养开始后4 h。 (4)以摇瓶分批发酵最优条件为基础,对FPN、F10、FCB、FNa、F14 和 FEm进行了摇瓶分批发酵试验。以摇瓶分批发酵试验数据为依据,对功能菌剂分批发酵动力学进行了研究,建立了菌体生长和基质消耗的动力学模型,拟合模型能较好的反映功能菌剂分批发酵过程。 (5)功能菌剂和活性污泥协同作用,可以提高系统的生物降解能力,功能菌剂投加量为2%,新鲜活性污泥3500 mg/L,降解24 h条件下,功能菌剂和活性污泥的协同作用对COD的去除率和对照组相比,最多的提高了36.8%。功能菌剂和活性污泥协同作用以及活性污泥的单独作用,其生物降解过程均符合一级反应动力学过程,功能菌剂和活性污泥协同作用的生物降解动力学方程为:,相关系数97%。采用SBR运行方式,引入功能菌剂的SBR系统明显能够改善和提高生物降解的效率。与仅有活性污泥的系统相比,系统对COD的平均去除率可以提高27.1%,同时,系统的耐负荷冲击以及耐毒害冲击的性能比仅有活性污泥的SBR系统强,特别是负荷冲击对引入功能菌剂的SBR系统影响很小。仅有活性污泥的SBR系统经过负荷冲击和毒害冲击之后,不能恢复到冲击之前的水平,而且系统有效作用时间的周期比引入功能菌剂的SBR系统相比大大缩短,而引入功能菌剂的SBR系统处理效果较为稳定,恢复能力很强。 Along with the development of industries, many recalcitrant organic chemicals have been discharged into natural environments together with wastewaters and can exist in waters, soil and sediments for a long time without degradation. These haz-ardous substances, their byporducts and metabolizabilities can be highly toxic, mu-tagenic and carcinogenic, thereby threatening animals, plants and human health through food chain. Consequently the removal of these compounds is of significant interest in the area of wastewater treatment. In this dissertation, the phenol, hydro-quinone, chlorobenzene and hexadecane treated as the model pollutants, the func-tional microorganism agent was used as the starting strains, they treated with ultra-violet light, and then the mutant strains with high degradation ability were screened out and identified primarily, the relationship between these stains were studied, the medium composition and fermentation conditions were optimized, the degradation ability of the fermented production was tested. The literature survey indicates that the study of the microorganism agent is far from complete and more information is re-quired on following problems. 1, Because of the complexity of relationship in mixed fermentation and the complicated factors, the study is hardly to process.2, There is a lack of information on the quality control of the producing process .3, And there is a lack of information on the stability about the microorganism agent. In this dissertation, the main results of the present study could be summarized as follows: (1)The degenerate starting strains were treated with the ultraviolet light, and six mutant strains with high biodegradation ability were screened out by using the me-dium with selective pressure of model pollutants. The mutant strains had great changes in colonialmorphology and ERIC-PCR fingerprinting. And the mutant strains got obvious advantages over the starting strains in degradation ability and over 20% improvement of removal rates was achieved for FPN、FCB、F14 and FEm. The de-gradation ability of the mutant strains was stable after seven generations. After that, the mutant strains were primarily identified as bacillus respectively. (2) The relationship between these mutant strains was studied. By the compari-son of antibiosis effect, biomass and consumption of substrate, the relationships were neutralism and they could be mixed fermented. (3) The optimized cultivation conditions were as follows: glucose 31.0 g/L, corn power 10 g/L, K2HPO4 1.0 g/L, (NH4)2SO4 1.1 g/L, MgSO4 0.55 g/L, initial pH7.5, temperature 32℃, working volume 125 mL/250 mL, and cultivation time 20h (con-sidering the time effect on degradation ability), adding pollutants phenol (1.125 g/L) and hydroquinone (0.1 g/L) into the broth at 4 h after cultivation. (4) Based on the above optimum condition, the batch fermentation was per-formed with strains FPN, F10, FCB, FNa, F14 and FEm in shake flask. The batch fermentation kinetics was studied based on the experimental data. Two kinetic models were constructed which could reflect the regularity of growth and substrate consump-tion in the process of batch fermentation. (5) The co-operation of functional microorganism agent and activated sludge could raise biodegradation of system by adding some microorganism agent and 3500 mg/L fresh activated sludge. Bioaugumentation by the addition of high effective deg-radation culture enhanced the treatment effect of SBR system and the COD removal rate was increased by 20%-36.8%. Its biodegradation matched first-order dynamical reaction equation, and the reaction equation was ln0.2327.391ct=−+. The micro-organism agent had the effect of optimization to activated sludge micro-ecosystem. The SBR system adding 2% microorganism agent, the average COD removal rate of that was increased by 27.1% and stronger anti-shock ability to load and toxicant were achieved (compared with SBR system just adding activated sludge). Especially the load-shock has barely effect to the SBR system adding microorganism agent. After the load and toxicant shock, the SBR system just adding activated sludge couldn’t come back to original level and the activated sludge micro-ecosystem was frustrated. The applying of microorganism agent increased biological activity and system’s re-sistance ability to load shock and toxicant shock.
Resumo:
Sialic acid and lysine as an internal standard substance,the ESI-MS fingerprinting of extracts of Compound Indigowoad Root Granule which from different origin was studied.The fingerprinting was obtained with better precision and reproducibility.This work can provide a reference for the quality control of Compound Indigowoad Root Granule.