442 resultados para Shunt embolization


Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: We sought to provide a contemporary picture of the presentation, etiology, and outcome of infective endocarditis (IE) in a large patient cohort from multiple locations worldwide. METHODS: Prospective cohort study of 2781 adults with definite IE who were admitted to 58 hospitals in 25 countries from June 1, 2000, through September 1, 2005. RESULTS: The median age of the cohort was 57.9 (interquartile range, 43.2-71.8) years, and 72.1% had native valve IE. Most patients (77.0%) presented early in the disease (<30 days) with few of the classic clinical hallmarks of IE. Recent health care exposure was found in one-quarter of patients. Staphylococcus aureus was the most common pathogen (31.2%). The mitral (41.1%) and aortic (37.6%) valves were infected most commonly. The following complications were common: stroke (16.9%), embolization other than stroke (22.6%), heart failure (32.3%), and intracardiac abscess (14.4%). Surgical therapy was common (48.2%), and in-hospital mortality remained high (17.7%). Prosthetic valve involvement (odds ratio, 1.47; 95% confidence interval, 1.13-1.90), increasing age (1.30; 1.17-1.46 per 10-year interval), pulmonary edema (1.79; 1.39-2.30), S aureus infection (1.54; 1.14-2.08), coagulase-negative staphylococcal infection (1.50; 1.07-2.10), mitral valve vegetation (1.34; 1.06-1.68), and paravalvular complications (2.25; 1.64-3.09) were associated with an increased risk of in-hospital death, whereas viridans streptococcal infection (0.52; 0.33-0.81) and surgery (0.61; 0.44-0.83) were associated with a decreased risk. CONCLUSIONS: In the early 21st century, IE is more often an acute disease, characterized by a high rate of S aureus infection. Mortality remains relatively high.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The complex and essential cell wall of Mycobacterium tuberculosis represents a plethora of new and old drug targets that collectively form an apparent mycobacterial “Achilles’ heel”. The mycolic acids are long-chain α-alkyl-β-hydroxy fatty acids (C70–90), which are unique to mycobacterial species, forming an integral component of the mycolyl–arabinogalactan–peptidoglycan complex. Their apparent uniqueness to the M. tuberculosis complex has rendered components of mycolic acid biosynthesis as powerful drug targets for specific tuberculosis (TB) chemotherapy. Here, I will discuss a contribution to TB drug discovery by deconvolution of the inhibitory mechanisms of a number of antitubercular compounds targeting mycolic acid biosynthesis. I will begin with the early days, elucidating the mode of action of ethionamide [1] and thiolactomycin [2], each targeting two separate components of the fatty acid synthase II (FAS-II) pathway. I will further discuss the recently discovered tetrahydropyrazo[1,5-a]pyrimidine-3-carboxamide compounds [3] which selectively target the essential, catalytically silent M. tuberculosis EchA6, providing a crucial lipid shunt between β-oxidation and FAS-II and supplying lipid precursors for essential mycolate biosynthesis. Finally, I will discuss the recent discovery of the mode of action of the indazole sulfonamides [4], inhibiting M. tuberculosis KasA by, a completely novel inhibitory mechanism.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La derivación portosistémica intrahepática transyugular (TIPS) es una técnica importante en el manejo de las complicaciones de la hipertensión portal, en especial en aquellos pacientes candidatos a trasplante hepático. Se trata de un estudio observacional analítico, sin riesgo, en el cual se emplearon técnicas y métodos de investigación documental retrospectivo, y no se realizó ningún tipo de intervención sobre las variables fisiológicas, psicológicas y sociales de la población incluida. Se realizó la descripción demográfica de los pacientes, características clínicas, hallazgos imageneológicos y aspectos técnicos asociados al procedimiento de los pacientes con hipertensión portal que han sido manejados con TIPS en la Fundación CardioInfantil desde Enero 1 de 2007 hasta Junio 30 de 2016. Se incluyeron 54 pacientes de los cuales el 66,7% no presentaron complicaciones inmediatas, tenidas en cuenta desde la terminación del procedimiento y hasta las siguientes 24 horas; sin embargo, 16,9% debutaron con encefalopatía durante este periodo. De las complicaciones tardías, la más frecuente fue la ascitis con un 66,7%, con una mortalidad de 20,4% de los cuales, el 45% de estos fue por shock séptico y falla orgánica secundaria. Aunque el porcentaje de complicaciones asociadas al procedimiento fue alto en nuestros pacientes, se encuentra dentro de los valores reportados en la literatura. Los resultados presentados son un punto de partida para la evaluación del procedimiento en nuestra población y permiten implementar estrategias de mejora que conlleven a incidir de manera positiva en el porcentaje de complicaciones y mortalidad derivadas del procedimiento.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este relatório foi elaborado no âmbito do estágio curricular do Mestrado Integrado em Medicina Veterinária. Encontra-se dividido em duas partes. Na primeira parte é feita uma análise da casuística seguida durante o estágio. A segunda parte é constituída por uma monografia de revisão bibliográfica sobre o tema ”Tromboembolismo Arterial Felino”(TAF), bem como a descrição e discussão de dois casos clínicos acompanhados durante o estágio. O TAF é caracterizado pela embolização de um trombo numa artéria da circulação sistémica, sendo a localização mais frequente a trifurcação ilíaca da artéria aorta. Na maioria dos casos, o trombo tem origem no átrio esquerdo, como resultado de cardiomiopatia. Apesar do diagnóstico ser facilmente obtido através de sinais clínicos, o tratamento e a prevenção desta afeção representam um desafio para o médico veterinário, já que a taxa de reincidência de tromboembolismo e mortalidade são elevadas, projectando um prognóstico reservado; Clinic and Surgery of Small Animals Abstract: This report was done within the scope of the internship integrated master’s degree in Veterinay Medicine. It is divided in two parts. In the first part, an analisys of the casuistic followed during the internship is done. The second part is composed by a literature review about the theme ”Feline Arterial Thromboembolism”(FAT), as well as the description and discussion of two clinical cases followed during the internship. FAT is characterized by the embolization of a thrombus in a artery of systemic circulation, being its location more frequently in iliac trifurcation of aorta artery. On most of the cases the thrombus has its origins on the left atrium, as a result of cardiomyopathy. Besides the diagnosis being easily obtained through clinical signs, the treatment and prevention of this disease represents a challenge to the veterinarian clinician, due to the FAT recurrance rate and high mortality, projecting a pour/reserved prognosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Shockley diode equation is basic for single diode model equation, which is overly used for characterizing the photovoltaic cell output and behavior. In the standard equation, it includes series resistance (Rs) and shunt resistance (Rsh) with different types of parameters. Maximum simulation and modeling work done previously, related to single diode photovoltaic cell used this equation. However, there is another form of the standard equation which has not included Series Resistance (Rs) and Shunt Resistance (Rsh) yet, as the Shunt Resistance is much bigger than the load resistance and the load resistance is much bigger than the Series Resistance. For this phenomena, very small power loss occurs within a photovoltaic cell. This research focuses on the comparison of two forms of basic Shockley diode equation. This analysis describes a deep understanding of the photovoltaic cell, as well as gives understanding about Series Resistance (Rs) and Shunt Resistance (Rsh) behavior in the Photovoltaic cell. For making estimation of a real time photovoltaic system, faster calculation is needed. The equation without Series Resistance and Shunt Resistance is appropriate for the real time environment. Error function for both Series resistance (Rs) and Shunt resistances (Rsh) have been analyzed which shows that the total system is not affected by this two parameters' behavior.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The paper states an introduction, description and implementation of a PV cell under the variation of parameters. Analysis and observation of a different parameters variation of a PV cell are discussed here. To obtain the model for the purpose of analyzing an equivalent circuit with the consisting parameters a photo current source, a series resistor, a shunt resistor and a diode is used. The fundamental equation of PV cell is used to study the model and to analyze and best fit observation data. The model can be used in measuring and understanding the behaviour of photovoltaic cells for certain changes in PV cell parameters. A numerical method is used to analyze the parameters sensitivity of the model to achieve the expected result and to understand the deviation of changes in different parameters situation at various conditions respectively. The ideal parameters are used to study the models behaviour. It is also compared the behaviour of current-voltage and power-voltage by comparing with produced maximum power point though it is a challenge to optimize the output with real time simulation. The whole working process is also discussed and an experimental work is also done to get the closure and insight about the produced model and to decide upon the validity of the discussed model.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper it is proposed to obtain enhanced and more efficient parameters model from generalized five parameters (single diode) model of PV cells. The paper also introduces, describes and implements a seven parameter model for photovoltaic cell (PV cell) which includes two internal parameters and five external parameters. To obtain the model the mathematical equations and an equivalent circuit consisting of a photo generated current source, a series resistor, a shunt resistor and a diode is used. The fundamental equation of PV cell is used to analyse and best fit the observation data. Especially bisection iteration method is used to obtain the expected result and to understand the deviation of changes in different parameters situation at various conditions respectively. The produced model can be used of measuring and understanding the actions of photovoltaic cells for certain changes and parameters extraction. The effect is also studied with I-V and P-V characteristics of PV cells though it is a challenge to optimize the output with real time simulation. The working procedure is also discussed and an experiment presented to get the closure and insight about the produced model and to decide upon the model validity. At the end, we observed that the result of the simulation is very close to the produced model.