990 resultados para Selective laser melting


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation presented to the Faculty of Sciences and Technology of New University of Lisbon in fulfilment of the requirements for the Master’s degree in Conservation and Restoration Specialization in easel painting

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conventional film based X-ray imaging systems are being replaced by their digital equivalents. Different approaches are being followed by considering direct or indirect conversion, with the later technique dominating. The typical, indirect conversion, X-ray panel detector uses a phosphor for X-ray conversion coupled to a large area array of amorphous silicon based optical sensors and a couple of switching thin film transistors (TFT). The pixel information can then be readout by switching the correspondent line and column transistors, routing the signal to an external amplifier. In this work we follow an alternative approach, where the electrical switching performed by the TFT is replaced by optical scanning using a low power laser beam and a sensing/switching PINPIN structure, thus resulting in a simpler device. The optically active device is a PINPIN array, sharing both front and back electrical contacts, deposited over a glass substrate. During X-ray exposure, each sensing side photodiode collects photons generated by the scintillator screen (560 nm), charging its internal capacitance. Subsequently a laser beam (445 nm) scans the switching diodes (back side) retrieving the stored charge in a sequential way, reconstructing the image. In this paper we present recent work on the optoelectronic characterization of the PINPIN structure to be incorporated in the X-ray image sensor. The results from the optoelectronic characterization of the device and the dependence on scanning beam parameters are presented and discussed. Preliminary results of line scans are also presented. (C) 2014 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia Mecânica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Microwave assisted synthesis of the Cu(I) compound [Cu(µ4-4-ptz)]n [1, 4-ptz = 5-(4-pyridyl)tetrazolate] has been performed by employing a relatively easy method and within a shorter period of time compared to its sister compounds. The syntheses of the Cu(II) compounds [Cu3(µ3-4-ptz)4(µ2-N3)2(DMF)2]n∙(DMF)2n (2) and [Cu(µ2-4-ptz)2(H2O)2]n (3) using a similar method were reported previously by us. MOFs 1-3 revealed high catalytic activity toward oxidation of cyclic alkanes (cyclopentane, -hexane and -octane) with aqueous hydrogen peroxide, under very mild conditions (at room temperature), without any added solvent or additive. The most efficient system (2/H2O2) showed, for the oxidation of cyclohexane, a turnover number (TON) of 396 (TOF of 40 h−1), with an overall product yield (cyclohexanol and cyclohexanone) of 40% relative to the substrate. Moreover, the heterogeneous catalytic systems 1–3 allowed an easy catalyst recovery and reuse, at least for four consecutive cycles, maintaining ca. 90% of the initial high activity and concomitant high selectivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Amorphous and crystalline sputtered boron carbide thin films have a very high hardness even surpassing that of bulk crystalline boron carbide (≈41 GPa). However, magnetron sputtered B-C films have high friction coefficients (C.o.F) which limit their industrial application. Nanopatterning of materials surfaces has been proposed as a solution to decrease the C.o.F. The contact area of the nanopatterned surfaces is decreased due to the nanometre size of the asperities which results in a significant reduction of adhesion and friction. In the present work, the surface of amorphous and polycrystalline B-C thin films deposited by magnetron sputtering was nanopatterned using infrared femtosecond laser radiation. Successive parallel laser tracks 10 μm apart were overlapped in order to obtain a processed area of about 3 mm2. Sinusoidal-like undulations with the same spatial period as the laser tracks were formed on the surface of the amorphous boron carbide films after laser processing. The undulations amplitude increases with increasing laser fluence. The formation of undulations with a 10 μm period was also observed on the surface of the crystalline boron carbide film processed with a pulse energy of 72 μJ. The amplitude of the undulations is about 10 times higher than in the amorphous films processed at the same pulse energy due to the higher roughness of the films and consequent increase in laser radiation absorption. LIPSS formation on the surface of the films was achieved for the three B-C films under study. However, LIPSS are formed under different circumstances. Processing of the amorphous films at low fluence (72 μJ) results in LIPSS formation only on localized spots on the film surface. LIPSS formation was also observed on the top of the undulations formed after laser processing with 78 μJ of the amorphous film deposited at 800 °C. Finally, large-area homogeneous LIPSS coverage of the boron carbide crystalline films surface was achieved within a large range of laser fluences although holes are also formed at higher laser fluences.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate the origin of ferromagnetism induced in thin-film (similar to 20 nm) Fe-V alloys by their irradiation with subpicosecond laser pulses. We find with Rutherford backscattering that the magnetic modifications follow a thermally stimulated process of diffusion decomposition, with formation of a-few-nm-thick Fe enriched layer inside the film. Surprisingly, similar transformations in the samples were also found after their long-time (similar to 10(3) s) thermal annealing. However, the laser action provides much higher diffusion coefficients (similar to 4 orders of magnitude) than those obtained under standard heat treatments. We get a hint that this ultrafast diffusion decomposition occurs in the metallic glassy state achievable in laser-quenched samples. This vitrification is thought to be a prerequisite for the laser-induced onset of ferromagnetism that we observe. 2014 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The reaction between 2-aminobenzenesulfonic acid and 2-hydroxy-3-methoxybenzaldehyde produces the acyclic Schiff base 2-[(2-hydroxy-3-methoxyphenyl) methylideneamino] benzenesulfonic acid (H2L center dot 3H(2)O) (1). In situ reactions of this compound with Cu(II) salts and, eventually, in the presence of pyridine (py) or 2,2'-bipyridine (2,2'-bipy) lead to the formation of the mononuclear complexes [CuL(H2O)(2)] (2) and [CuL(2,2'-bipy)]center dot DMF center dot H2O (3) and the diphenoxo-bridged dicopper compounds [CuL(py)](2) (4) and [CuL(EtOH)](2)center dot 2H(2)O (5). In 2-5 the L-2-ligand acts as a tridentate chelating species by means of one of the O-sulfonate atoms, the O-phenoxo and the N-atoms. The remaining coordination sites are then occupied by H2O (in 2), 2,2'-bipyridine (in 3), pyridine (in 4) or EtOH (in 5). Hydrogen bond interactions resulted in R-2(2) (14) and in R-4(4)(12) graph sets leading to dimeric species (in 2 and 3, respectively), 1D chain associations (in 2 and 5) or a 2D network (1). Complexes 2-5 are applied as selective catalysts for the homogeneous peroxidative (with tert-butylhydroperoxide, TBHP) oxidation of primary and secondary alcohols, under solvent-and additive-free conditions and under low power microwave (MW) irradiation. A quantitative yield of acetophenone was obtained by oxidation of 1-phenylethanol with compound 4 [TOFs up to 7.6 x 10(3) h(-1)] after 20 min of MW irradiation, whereas the oxidation of benzyl alcohol to benzaldehyde is less effective (TOF 992 h(-1)). The selectivity of 4 to oxidize the alcohol relative to the ene function is demonstrated when using cinnamyl alcohol as substrate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A exploração do meio subaquático utilizando visão computacional é ainda um processo complexo. Geralmente são utilizados sistemas de visão baseados em visão stereo, no entanto, esta abordagem apresenta limitações, é pouco precisa e é exigente em termos computacionais quando o meio de operação é o subaquático. Estas limitações surgem principalmente em dois cenários de aplicação: quando existe escassez de iluminação e em operações junto a infraestruturas subaquáticas. Consequentemente, a solução reside na utilização de fontes de informação sensorial alternativas ou complementares ao sistema de visão computacional. Neste trabalho propõe-se o desenvolvimento de um sistema de percepção subaquático que combina uma câmara e um projetor laser de um feixe em linha, onde o projetor de luz estruturada _e utilizado como fonte de informação. Em qualquer sistema de visão computacional, e ainda mais relevante em sistemas baseados em triangulação, a sua correta calibração toma um papel fulcral para a qualidade das medidas obtidas com o sistema. A calibração do sistema de visão laser foi dividida em duas etapas. A primeira etapa diz respeito à calibração da câmara, onde são definidos os parâmetros intrínsecos e os parâmetros extrínsecos relativos a este sensor. A segunda etapa define a relação entre a câmara e o laser, sendo esta etapa necessária para a obtenção de imagens tridimensionais. Assim, um dos principais desafios desta dissertação passou por resolver o problema da calibração inerente a este sistema. Desse modo, foi desenvolvida uma ferramenta que requer, pelo menos duas fotos do padrão de xadrez, com perspectivas diferentes. O método proposto foi caracterizado e validado em ambientes secos e subaquáticos. Os resultados obtidos mostram que o sistema _e preciso e os valores de profundidade obtidos apresentam um erro significativamente baixo (inferiores a 1 mm), mesmo com uma base-line (distância entre a centro óptico da câmara e o plano de incidência do laser) reduzida.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia Biomédica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de Mestrado em Conservação e Restauro - Metais

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente trabalho visa apresentar a temática da otimização da produção de corte laser numa empresa do ramo da indústria metalomecânica, denominada Sermec Laser e situada no concelho da Maia no Distrito do Porto. Para alcançar este objetivo foi necessário conhecer o funcionamento atual do processo, como por exemplo, os seus intervenientes, as taxas de ocupação do equipamento de corte a laser e os procedimentos. Só depois de ser explorada essa vertente será possível desenvolver um plano com vista a melhorar esse processo. Este projeto espera criar um plano de melhoria que será testado e, quando for validado, será implementado. As melhorias propostas por este plano passam pelo aumento da eficiência do processo de corte a laser e a alteração de parte do layout da empresa de forma a facilitar e agilizar este mesmo processo. O objetivo final será acrescentar mais valor ao processo, reduzindo os seus desperdícios. Com esta melhoria a empresa ficará a ganhar, pois irá produzir de forma mais ajustada às suas necessidades.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation presented to obtain the Ph.D. degree in Chemistry

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Genética Molecular e Biomedicina

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Burkholderia cepacia colonizes cystic fibrosis (CF) patients. We evaluated the impact of the use of a selective medium in the rate of B. cepacia recovery from respiratory samples of CF patients. During a 6-month period, respiratory samples were collected from 106 CF patients and cultivated on selective media including a B. cepacia selective medium. Confirmation of the identity of B. cepacia isolates was carried out by species specific PCR and determination of genomovar status performed by a sequential PCR approach. Results of B. cepacia isolation during this period were compared to the preceding two years, when the sample processing was identical except for the lack of the B. cepacia selective medium. B. cepacia was isolated in 11/257 (4.2%) of the samples using the selective medium, in contrast with the preceding two years, when it was isolated in 6/1029 samples (0.58%), p < 0.0001. Identity of all 11 isolates was confirmed by PCR and genomovar determination was accomplished in all but one isolate. These results suggest that the use of a selective medium increases recovery rate of B. cepacia from respiratory samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Carnitine (CRT) is a biological metabolite found in urine that contributes in assessingseveral disease conditions, including cancer. Novel quick screening procedures for CRT are therefore fundamental. This work proposes a novel potentiometric device where molecularly imprinted polymers (MIPs) were used as ionophores. The host-tailored sites were imprinted on a polymeric network assembled by radical polymerization of methacrylic acid (MAA) and trimethylpropane trimethacrylate (TRIM). Non-imprinted polymers (NIPs) were produced as control by removing the template from the reaction media. The selective membrane was prepared by dispersing MIP or NIP particles in plasticizer and poly(vinyl chloride), PVC, and casting this mixture over a solid contact support made of graphite. The composition of the selective membrane was investigated with regard to kind/amount of sensory material (MIP or NIP), and the need for a lipophilic additive. Overall, MIP sensors with additive exhibited the best performance, with near-Nernstian response down to ~ 1 × 10− 4 mol L− 1, at pH 5, and a detection limitof ~ 8 × 10− 5 mol L− 1. Suitable selectivity was found for all membranes, assessed by the matched potential method against some of the most common species in urine (urea, sodium, creatinine, sulfate, fructose and hemoglobin). CRT selective membranes including MIP materials were applied successfully to the potentiometric determination of CRT in urine samples.