938 resultados para SURGICAL-CORRECTION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Correction of sagittal and transverse maxillary discrepancies in patients with cleft lip or palate remains a challenge for craniofacial surgeons. Distraction osteogenesis has revolutionized the conceptualization and approach to the craniofacial malformations and has become a reliable and irreplaceable part of the surgical armamentarium. We are reporting a case of sequential maxillary advancement and transpalatal expansion using internal distraction in a patient with unilateral cleft lip and palate presenting with severe maxillary sagittal and transverse deficiencies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

After reviewing the general principles of eyelid reconstruction, the authors present reconstruction techniques with regard to the location and size of the eyelid defect. When the defect is less than one-quarter of lid length, direct suture is possible. When the defect is larger, reconstruction techniques differ for the upper and lower lid.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This letter discusses the detection and correction ofresidual motion errors that appear in airborne synthetic apertureradar (SAR) interferograms due to the lack of precision in the navigationsystem. As it is shown, the effect of this lack of precision istwofold: azimuth registration errors and phase azimuth undulations.Up to now, the correction of the former was carried out byestimating the registration error and interpolating, while the latterwas based on the estimation of the phase azimuth undulations tocompensate the phase of the computed interferogram. In this letter,a new correction method is proposed, which avoids the interpolationstep and corrects at the same time the azimuth phase undulations.Additionally, the spectral diversity technique, used to estimateregistration errors, is critically analyzed. Airborne L-bandrepeat-pass interferometric data of the German Aerospace Center(DLR) experimental airborne SAR is used to validate the method

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CONTEXT: A passive knee-extension test has been shown to be a reliable method of assessing hamstring tightness, but this method does not take into account the potential effect of gravity on the tested leg. OBJECTIVE: To compare an original passive knee-extension test with 2 adapted methods including gravity's effect on the lower leg. DESIGN: Repeated measures. SETTING: Laboratory. PARTICIPANTS: 20 young track and field athletes (16.6 ± 1.6 y, 177.6 ± 9.2 cm, 75.9 ± 24.8 kg). INTERVENTION: Each subject was tested in a randomized order with 3 different methods: In the original one (M1), passive knee angle was measured with a standard force of 68.7 N (7 kg) applied proximal to the lateral malleolus. The second (M2) and third (M3) methods took into account the relative lower-leg weight (measured respectively by handheld dynamometer and anthropometrical table) to individualize the force applied to assess passive knee angle. MAIN OUTCOME MEASURES: Passive knee angles measured with video-analysis software. RESULTS: No difference in mean individualized applied force was found between M2 and M3, so the authors assessed passive knee angle only with M2. The mean knee angle was different between M1 and M2 (68.8 ± 12.4 vs 73.1 ± 10.6, P < .001). Knee angles in M1 and M2 were correlated (r = .93, P < .001). CONCLUSIONS: Differences in knee angle were found between the original passive knee-extension test and a method with gravity correction. M2 is an improved version of the original method (M1) since it minimizes the effect of gravity. Therefore, we recommend using it rather than M1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background:¦Infection after total or partial hip arthroplasty (HA) leads to significant long-­term morbidity and high healthcare cost. We evaluated reasons for treatment failure of different surgical modalities in a 12-­year prosthetic hip joint infection cohort study.¦Method:¦All patients hospitalized at our institution with infected HA were included either retrospectively (1999-­‐2007) or prospectively¦(2008-­‐2010). HA infection was defined as growth of the same microorganism in ≥2 tissues or synovialfluid culture, visible purulence, sinus tract or acute inflammation on tissue histopathology. Outcome analysis was performed at outpatient visits, followed by contacting patients, their relatives and/or treating physicians afterwards.¦Results:¦During the study period, 117 patients with infected HA were identified. We excluded 2 patients due to missing data. The average age was 69 years (range, 33-­‐102 years); 42% were female. HA was mainly performed for osteoarthritis (n=84), followed by trauma (n=22), necrosis (n=4), dysplasia(n=2), rheumatoid arthritis (n=1), osteosarcoma (n=1) and tuberculosis (n=1). 28 infections occurred early(≤3 months), 25 delayed (3-­‐24 months) and 63 late (≥24 months after surgery). Infected HA were¦treated with (i) two-­‐stage exchange in 59 patients (51%, cure rate: 93%), (ii) one-­‐stage exchange in 5 (4.3%, cure rate: 100%), (iii) debridement with change of mobile parts in 18 (17%, cure rate: 83%), (iv) debridement without change of mobile¦parts in 17 (14%, cure rate : 53% ), (v) Girdlestone in 13 (11%, cure rate: 100%), and (vi) two-­‐stage exchange followed by¦removal in 3 (2.6%). Patients were followed for an average of 3.9 years (range, 0.1 to 9 years), 7 patients died unrelated to the infected HA. 15 patients (13%) needed additional operations, 1 for mechanical reasons(dislocation of spacer) and 14 for persistent infection: 11 treated with debridement and retention (8 without change; and 3 with change of mobile parts) and 3 with two-­‐stage exchange. The average number of surgery was 2.2 (range, 1 to 5). The infection was finally eradicated in all patients, but the functional outcome remained unsatisfactory in 20% (persistent pain or impaired mobility due to spacer or Girdlestone situation).¦Conclusions:¦Non-­‐respect of current treatment concept leads to treatment failure with subsequent operations. Precise analysis of each treatment failure can be used for improving the treatment algorithm leading to better results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

IMPORTANCE: Owing to a considerable shift toward bioprosthesis implantation rather than mechanical valves, it is expected that patients will increasingly present with degenerated bioprostheses in the next few years. Transcatheter aortic valve-in-valve implantation is a less invasive approach for patients with structural valve deterioration; however, a comprehensive evaluation of survival after the procedure has not yet been performed. OBJECTIVE: To determine the survival of patients after transcatheter valve-in-valve implantation inside failed surgical bioprosthetic valves. DESIGN, SETTING, AND PARTICIPANTS: Correlates for survival were evaluated using a multinational valve-in-valve registry that included 459 patients with degenerated bioprosthetic valves undergoing valve-in-valve implantation between 2007 and May 2013 in 55 centers (mean age, 77.6 [SD, 9.8] years; 56% men; median Society of Thoracic Surgeons mortality prediction score, 9.8% [interquartile range, 7.7%-16%]). Surgical valves were classified as small (≤21 mm; 29.7%), intermediate (>21 and <25 mm; 39.3%), and large (≥25 mm; 31%). Implanted devices included both balloon- and self-expandable valves. MAIN OUTCOMES AND MEASURES: Survival, stroke, and New York Heart Association functional class. RESULTS: Modes of bioprosthesis failure were stenosis (n = 181 [39.4%]), regurgitation (n = 139 [30.3%]), and combined (n = 139 [30.3%]). The stenosis group had a higher percentage of small valves (37% vs 20.9% and 26.6% in the regurgitation and combined groups, respectively; P = .005). Within 1 month following valve-in-valve implantation, 35 (7.6%) patients died, 8 (1.7%) had major stroke, and 313 (92.6%) of surviving patients had good functional status (New York Heart Association class I/II). The overall 1-year Kaplan-Meier survival rate was 83.2% (95% CI, 80.8%-84.7%; 62 death events; 228 survivors). Patients in the stenosis group had worse 1-year survival (76.6%; 95% CI, 68.9%-83.1%; 34 deaths; 86 survivors) in comparison with the regurgitation group (91.2%; 95% CI, 85.7%-96.7%; 10 deaths; 76 survivors) and the combined group (83.9%; 95% CI, 76.8%-91%; 18 deaths; 66 survivors) (P = .01). Similarly, patients with small valves had worse 1-year survival (74.8% [95% CI, 66.2%-83.4%]; 27 deaths; 57 survivors) vs with intermediate-sized valves (81.8%; 95% CI, 75.3%-88.3%; 26 deaths; 92 survivors) and with large valves (93.3%; 95% CI, 85.7%-96.7%; 7 deaths; 73 survivors) (P = .001). Factors associated with mortality within 1 year included having small surgical bioprosthesis (≤21 mm; hazard ratio, 2.04; 95% CI, 1.14-3.67; P = .02) and baseline stenosis (vs regurgitation; hazard ratio, 3.07; 95% CI, 1.33-7.08; P = .008). CONCLUSIONS AND RELEVANCE: In this registry of patients who underwent transcatheter valve-in-valve implantation for degenerated bioprosthetic aortic valves, overall 1-year survival was 83.2%. Survival was lower among patients with small bioprostheses and those with predominant surgical valve stenosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the relationship between changes in body bioelectrical impedance (BI) at 0.5, 50 and kHz and the changes in body weight, as an index of total body water changes, in acutely ill surgical patients during the rapid infusion of isotonic saline solution. DESIGN: Prospective clinical study. SETTING: Multidisciplinary surgical ICU in a university hospital. PATIENTS: Twelve male patients treated for acute surgical illness (multiple trauma n = 5, major surgery n = 7). Selection criteria: stable cardiovascular parameters, normal cardiac function, signs of hypovolemia (CVP < or = 5 mmHg, urine output < 1 ml/kg x h). INTERVENTIONS: After baseline measurements, a 60 min fluid challenge test was performed with normal saline solution, 0.25 ml/kg/min [corrected]. MEASUREMENTS AND RESULTS: Body weight (platform digital scale), total body impedance (four-surface electrode technique; measurements at 0.5, 50 and 100 kHz) and urine output. Fluid retention induced a progressive decrease in BI at 0.5, 50 and 100 kHz, but the changes were significant for BI 0.5 and BI 100 only, from 40 min after the beginning of the fluid therapy onwards. There was a significant negative correlation between changes in water retention and BI 0.5, with individual correlation coefficients ranging from -0.72 to 0.95 (p < 0.01-0.0001). The slopes of the regression lines indicated that for each kg of water change, there was a mean decrease in BI of 18 ohm, but a substantial inter-individual variability was noted. CONCLUSION: BI measured at low frequency can represent a valuable index of acute changes in body water in a group of surgical patients but not in a given individual.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selostus: Hevosen alkioiden värjääminen DAPI:lla ennen vastaanottajaan siirtoa

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bilateral fetal rhabdomyomatous nephroblastoma is a rare variant of Wilms' Tumor. The authors report the evolution over 48 months of a 10-month-old baby with bilateral nephroblastoma for which a left nephrectomy was initially performed. A right kidney tumor was enucleated preserving the kidney. The transformation of the primary tumor into a completely differentiated cystic nephroblastoma or nephromalike tumor and the appearance of a metachronous lesion was seen. This report emphasizes the role of nephron-sparing surgery in bilateral Wilms' Tumor when a benign transformation occurs under chemotherapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Weather radar observations are currently the most reliable method for remote sensing of precipitation. However, a number of factors affect the quality of radar observations and may limit seriously automated quantitative applications of radar precipitation estimates such as those required in Numerical Weather Prediction (NWP) data assimilation or in hydrological models. In this paper, a technique to correct two different problems typically present in radar data is presented and evaluated. The aspects dealt with are non-precipitating echoes - caused either by permanent ground clutter or by anomalous propagation of the radar beam (anaprop echoes) - and also topographical beam blockage. The correction technique is based in the computation of realistic beam propagation trajectories based upon recent radiosonde observations instead of assuming standard radio propagation conditions. The correction consists of three different steps: 1) calculation of a Dynamic Elevation Map which provides the minimum clutter-free antenna elevation for each pixel within the radar coverage; 2) correction for residual anaprop, checking the vertical reflectivity gradients within the radar volume; and 3) topographical beam blockage estimation and correction using a geometric optics approach. The technique is evaluated with four case studies in the region of the Po Valley (N Italy) using a C-band Doppler radar and a network of raingauges providing hourly precipitation measurements. The case studies cover different seasons, different radio propagation conditions and also stratiform and convective precipitation type events. After applying the proposed correction, a comparison of the radar precipitation estimates with raingauges indicates a general reduction in both the root mean squared error and the fractional error variance indicating the efficiency and robustness of the procedure. Moreover, the technique presented is not computationally expensive so it seems well suited to be implemented in an operational environment.