900 resultados para STOCKINGS, COMPRESSION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim. Extrinsic compression of the popliteal artery and absence of surrounding anatomical abnormalities characterize the functional popliteal artery entrapment syndrome (PAES). The diagnosis is confirmed to individuals who have typical symptoms of popliteal entrapment and occlusion or important stenosis of the popliteal artery with color duplex sonography (CDS), magnetic resonance imaging (MRI) or arteriography during active plantar flexion-extension maneuvers. However, variable result findings in normal asymptomatic subjects have raised doubts as to the validity of these tests. The purpose of this study was to compare the frequency of popliteal artery compression in 2 groups of asymptomatic subjects, athletes and non-athletes.Methods. Forty-two individuals were studied. Twenty-one subjects were indoor soccer players, and 21 were sedentary individuals. Physical activity was evaluated through questionnaires, anthropometric measurements, and cardiopulmonary exercise test. Evaluation of popliteal artery compression was performed in lower limbs with CDS, ankle-brachial index (ABI) measurements and continuous wave Doppler of the posterior tibial artery.Results. The athletes studied fulfilled the criteria of high level of physical activity whereas sedentary subjects met the criteria of low level of activity. Popliteal artery compression was observed with CDS in 6 (14.2%) studied subjects; 2 of whom (4.7%) were athletes and 4 (9.5%) were non-athletes. This difference was not statistically significant (p=0.21). Doppler of the tibial arteries and ABI measurements gave good specificity and sensibility in the identification of popliteal artery compression.Conclusion. The frequency of popliteal artery compression during maneuvers in normal subjects was 14.2% irrespective of whether or not they performed regular physical activities. Both Doppler and ABI showed good agreement with CDS and should be considered in screening popliteal arteries in individuals suspected of PAES.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of this study was to evaluate the thickness of the periodontal ligament of rat molars during orthodontic tooth movement (OTM). METHODS: Thirty Wistar rats were divided into three groups of 10 animals each: GI, GII and GIII and the mice were euthanized at 7, 14 and 21 days, respectively. Experimental subjects were compared to their respective controls by the Mann-Whitney test. Comparison of values between compression and tension sides were performed during the same and different time periods through Analysis of Variance (ANOVA), Kruskal-Wallis test and, subsequently, Tukey's test. RESULTS: Groups GI and GII showed decreased PDL size in the apical regions of the mesiobuccal root and in the cervical region of the distobuccal root. There was also an increased PDL in the cervical regions of the mesiobuccal root, apical region of the distobuccal root and middle region of both roots. CONCLUSION: The reduction and increase in PDL size were seen in the same root, which characterizes tooth inclination. The apical, middle and cervical regions were compared with one another in each time period and at three times: 7, 14 and 21 days. They were also compared in each region, confirming a tipping movement in GI and GII and a gradual decreased intensity between GI to GII, reaching normal dimension in GIII.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tanomaru-Filho M, Silveira GF, Reis JMSN, Bonetti-Filho I, Guerreiro-Tanomaru JM. Effect of compression load and temperature on thermomechanical tests for gutta-percha and Resilon (R). International Endodontic Journal, 44, 1019-1023, 2011.Aim To analyse a method used to evaluate the thermomechanical properties of gutta-percha and Resilon at different temperatures and compression loads.Methodology Two hundred and seventy specimens measuring 10 mm in diameter and 1.5 mm in height were made from the following materials: conventional gutta-percha (GCO). thermoplastic gutta-percha (GTP) and Resilon (R) cones (RE). After 24 h, the specimens were placed in water at 50 degrees C. 60 degrees C or 70 degrees C for 60 s. After that, specimens were placed between two glass slabs, and loads weighing 1.0, 3.0 or 5.0 kg were applied. Images of the specimens were digitized before and after the test and analysed using imaging software to determine their initial and final areas. The thermomechanical property of each material was determined by the difference between the initial and final areas of the specimens. Data were subjected to ANOVA and SNK tests at 5% significance. To verify a possible correlation between the results of the materials, linear regression coefficients (r) were calculated.Results Data showed higher flow area values for RE under all compression loads at 70 degrees C and under the 5.0 kg load at 60 degrees C (P < 0.05). Regarding gutta-percha, GTP showed higher flow under loads weighing 3.0 and 5.0 kg. at 60 and 70 degrees C (P < 0.05). GCO presented higher flow at 70 degrees C with a load of 5.0 kg. Regression analyses showed a poor linear correlation amongst the results of the materials under the different experimental conditions.Conclusion Gutta-percha and Resilon (R) cones require different compression loads and temperatures for evaluation of their thermomechanical properties. For all materials, the greatest flow occurred at 70 degrees C under a load of 5.0 kg: therefore. these parameters may be adopted when evaluating endodontic tilling materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Analysis of physical phenomena that occurs during tablet disintegration has been studied by several experimental approaches; however none of them satisfactorily describe this process. The aim of this study was to investigate the influence of compression force on the tablets by associating the AC Biosusceptometry with consolidated methods in order to validate the biomagnetic technique as a tool for quality control in pharmaceutical processes.Tablets obtained at five compression levels were submitted to mechanical properties tests. For uncoated tablets, water uptake and disintegration force measurements were performed in order to compare with magnetic data. For coated tablets, magnetic measurements were carried out to establish a relationship between physical parameters of the disintegration process. According to the results, differences between the compression levels were found for water uptake, force development and magnetic area variation measurements. ACB method was able to estimate the disintegration properties as well as the kinetics of disintegration process for uncoated and coated tablets. This study provided a new approach for in vitro investigation and validated this biomagnetic technique as a tool for quality control for pharmaceutical industry. Moreover, using ACB will also be possible to test these parameters in humans allowing to establish an in vitro/in vivo correlation (IVIVC). (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: This study evaluated, in vitro, the fracture resistance of human non-vital teeth restored with different reconstruction protocols. Material and methods: Forty human anterior roots of similar shape and dimensions were assigned to four groups (n=10), according to the root reconstruction protocol: Group I (control): non-weakened roots with glass fiber post; Group II: roots with composite resin by incremental technique and glass fiber post; Group III: roots with accessory glass fiber posts and glass fiber post; and Group IV: roots with anatomic glass fiber post technique. Following post cementation and core reconstruction, the roots were embedded in chemically activated acrylic resin and submitted to fracture resistance testing, with a compressive load at an angle of 45 degrees in relation to the long axis of the root at a speed of 0.5 mm/min until fracture. All data were statistically analyzed with bilateral Dunnett's test (alpha=0.05). Results: Group I presented higher mean values of fracture resistance when compared with the three experimental groups, which, in turn, presented similar resistance to fracture among each other. None of the techniques of root reconstruction with intraradicular posts improved root strength, and the incremental technique was suggested as being the most recommendable, since the type of fracture that occurred allowed the remaining dental structure to be repaired. Conclusion: The results of this in vitro study suggest that the healthy remaining radicular dentin is more important to increase fracture resistance than the root reconstruction protocol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using a collective potential derived previously on the basis of the generator coordinate method with Skyrme interactions, we obtain values for the compression modulus of Ca-40 which are in good agreement with a recently obtained experimental value. Calculated values for the compression modulus for O-16 are also given. The procedure involved in the derivation of the collective potential is briefly reviewed and discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUÇÃO: Estratégias efetivas para profilaxia do tromboembolismo venoso (TEV) são amplamente disponíveis, mas são ainda subutilizadas, principalmente no nosso meio. OBJETIVO: Avaliar o efeito da implementação de diretriz para profilaxia do TEV, em pacientes cirúrgicos, sobre a conduta da equipe de saúde na prescrição dessa profilaxia. Método. Estudo retrospectivo pré-intervenção - pós-intervenção. Prontuários de 150 pacientes antes e 150 depois da implementação de uma diretriz para a profilaxia (AID e DID) foram sorteados dentre pacientes de mais de 40 anos internados para cirurgia maior abdominal ou ortopédica. Foram registrados dados demográficos, referência a risco de TEV no prontuário, prescrição de profilaxia para TEV e diagnóstico de TEV durante a internação. RESULTADOS: Não houve diferença entre os dois grupos, AID e DID, quanto aos dados demográficos e ao tempo de profilaxia (5,6 x 6,6 dias). A frequência de profilaxia AID x DID antes da cirurgia foi: profilaxia farmacológica (PF), 6% x 9%; meias de compressão graduada (MCG), 4% x 3%; compressão pneumática intermitente (CPI), 2% x 3%. Após cirurgia: PF 53% x 53%; MCG, 23% x 40% (P<0,05); CPI, 26% x 32% . No total, AP, foi prescrita profilaxia para 60,5% dos pacientes AID e para 66,5% DID, mas a profilaxia foi considerada adequada em 34% dos pacientes AID e em 32% DID. Conclusão. A adoção do protocolo, embora com maior a preocupação com a profilaxia, traduzida pelo aumento na prescrição de MCG, melhorou minimamente sua qualidade, indicando a necessidade de outras intervenções ativas e contínuas para aumentar a aderência ao mesmo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statement of problem. A clinically significant incisal pin opening may occur after processing complete dentures if a compression molding technique is used. To recover the proper vertical dimension of occlusion, a time-consuming occlusal adjustment is necessary that often destroys the anatomy of the artificial teeth. A new injection molding process claims to produce dentures that require few, if any, occlusal adjustments in the laboratory after processing.Purpose. This laboratory study compared incisal pin opening, dimensional accuracy, and laboratory working time for dentures fabricated by this new injection system with dentures constructed by the conventional compression molding technique.Material and methods. Two groups of 6 maxillary and 6 mandibular dentures were evaluated as follows: group 1 (control), Lucitone 199, compression molded with a long cure cycle; and group 2, Lucitone 199, injection molded with a long cure. Incisal pin opening was measured with a micrometer immediately after deflasking. A computerized coordinate measuring machine was used to measure dimensional accuracy of 3-dimensional variations in selected positions of artificial teeth in 4 stages of denture fabrication. Analysis of variance (ANOVA) and t tests were performed to compare the groups.Results. A significant difference was found in pin opening between groups (t test). Horizontal dimensional changes evaluated with repeated measures ANOVA revealed no significant differences between groups. However, analysis of vertical dimensional changes disclosed significant differences between the groups. There was no appreciable difference in laboratory working time for flasking and molding denture bases between the injection and compression molding techniques when polymethyl methacrylate resin was used.Conclusion. The injection molding method produced a significantly smaller incisal pin opening over the standard compression molding technique. The injection molding technique, using polymethyl methacrylate, was a more accurate method for processing dentures. There were no appreciable differences in laboratory working time between the injection and compression molding techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Brazilian Standard ABNT NBR7190:1997 for timber structures design, adopts a first degree equation to describe the influence of wood moisture content. Periodically, when necessary, the referred standard is revised in order to analyze inconsistencies and to adopt considerations according new realities verified. So, the present paper aims to examine the adequacy of its equation which corrects to 12% of moisture the values of rigidity properties obtained on experimental tests. To quantify the moisture influence on modulus of elasticity, it was applied tests of compression parallel to the grain for six specimens of different strength classes, considering nominal moisture of 12; 20; 25; 30%. As results, modulus of elasticity in the moisture range 25-30% showed statistically equivalents, and was obtained a first degree equation to correlate the studied variables which leads to statically equivalent estimations when compared with results by ABNT NBR7190:1997 equation. However, it was indicated to maintain the current expression for the next text of the referred document review, without prejudice to statistical significance of the estimates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors report two female patients with chronic sensitive and motor findings in lower limbs caused by compression of distal branches of sciatic nerve by lipoma. Similar eases were not described on literature. Nerve conduction studies allowed to localize the exact site of compression. At surgery, lipomas compressing the deep peroneal nerve (case 1) and the posterior tibial nerve (case 2) were observed. Histologic studies of tumors confirmed the diagnoses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work has been performed at Tapetes Sao Carlos-Brazil with the cooperation of the DaimlerChrysler Research Center Team in Ulm - Germany. The objective of the present paper is to report the results obtained with natural fiber reinforced unsaturated polyester (UP) composites, concerning surface quality measurements. The fibers that have been chosen for this work were sisal and curaua. The samples were produced by compression molding technique and afterwards submitted to three different tests, namely: a) thermal aging; b) water absorption and c) artificial weathering. The surface parameters measured before and after the tests were gloss, haze, short and long-waviness. The results have shown that after the tests there is a high loss of gloss, a high increase in haze, and a high increase in short and long-waviness as well. Curaua reinforced composites had a slightly better behavior when compared with sisal reinforced composites. The effect of the presence of filler and the addition of thermoplastic polyester (TP) on the material behavior has not been evidently detected. This result shows that the conventional technology/methods applied to UP-Fiberglass systems cannot be transferred to natural fibers without any modification. The fiber-matrix interaction and its response to the presence of additives must be fully understood before a successful processing route can be developed for painted natural fibers reinforced UP. Copyright © 2001 Society of Automotive Engineers, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A gas of non-interacting particles diffuses in a lattice of pulsating scatterers. In the finite-horizon case with bounded distance between collisions and strongly chaotic dynamics, the velocity growth (Fermi acceleration) is well described by a master equation, leading to an asymptotic universal non-Maxwellian velocity distribution scaling as v∼t. The infinite-horizon case has intermittent dynamics which enhances the acceleration, leading to v∼t ln t and a non-universal distribution. © Copyright EPLA, 2013.