985 resultados para Remote Monitoring


Relevância:

20.00% 20.00%

Publicador:

Resumo:

NanoPT 2014 International Conference, in Portugal, on February 12-14. Poster presentation based on topic Nanobio/Nanomedicine

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work the mission control and supervision system developed for the ROAZ Autonomous Surface Vehicle is presented. Complexity in mission requirements coupled with flexibility lead to the design of a modular hierarchical mission control system based on hybrid systems control. Monitoring and supervision control for a vehicle such as ROAZ mission is not an easy task using tools with low complexity and yet powerful enough. A set of tools were developed to perform both on board mission control and remote planning and supervision. “ROAZ- Mission Control” was developed to be used in support to bathymetric and security missions performed in river and at seas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diversity of mosquito species was evaluated in different habitats before and after the Igarapava reservoir flooding in the Grande River, Southern Cerrado of Brazil. We aimed at verifying changes in these mosquito populations in consequence of the lake formation. Four habitats were selected as sampling stations: peridomiciliary habitat, pasture, "veredas" and gallery forest patch. Bimonthly collections were made with the Shannon trap and human bait, including diurnal, crepuscular and nocturnal period of mosquito activity. The Shannon Index results from the potential vectors were compared using Student t-test. Aedes scapularis, Anopheles darlingi and An. albitarsis senso latu seasonal abundance were described with moving average and compared using chi2 test. There were changes in the mosquito frequency in the habitats, except for the "veredas" that was 13 km away from the catchment area. The altering in mosquito species seasonal abundance suggests breeding places expansion. Diversity indexes can be used to monitor changes in mosquito vector population in environments where abrupt disturbance can alter disease transmission cycles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Poster presented in 28th GI/ITG International Conference on Architecture of Computing Systems (ARCS 2015). 25 to 28, Mar, 2015, Poster Session. Porto, Portugal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The 15th International Conference on Runtime Verification (RV'15). 22-25 September. Vienna, Austria.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Forty-six allogeneic hematopoietic stem cell transplantation (HSCT) patients were monitored for the presence of CMV antibodies, CMV-DNA and CMV antigens after transplantation. Immunoenzymatic serological tests were used to detect IgM and the increase in CMV IgG antibodies (increase IgG), a nested polymerase chain reaction (N-PCR) was used to detect CMV-DNA, and an antigenemia assay (AGM) was used to detect CMV antigens. The presence of CMV-IgM and/or CMV-increase IgG antibodies was detected in 12/46 (26.1%) patients, with a median time between HSCT and the detection of positive serology of 81.5 days. A positive AGM was detected in 24/46 (52.2%) patients, with a median time between HSCT and antigen detection of 62 days. Two or more consecutive positive N-PCR results were detected in 32/46 (69.5%) patients, with a median time between HSCT and the first positive PCR of 50.5 days. These results confirmed that AGM and mainly PCR are superior to serology for the early diagnosis of CMV infection. Six patients had CMV-IgM and/or CMV-increase IgG with a negative AGM (five cases) or N-PCR assay (one case). In five of these cases the serological markers were detected during the first 100 days after HSCT, the period of highest risk. These findings support the idea that serology may be useful for monitoring CMV infections in HSCT patients, especially when PCR is unavailable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Electromyography (EMG) is an important tool for gait analyzes and disorders diagnoses. Traditional methods involve equipment that can disturb the analyses, being gradually substituted by different approaches, like wearable and wireless systems. The cable replacement for autonomous systems demands for technologies capable of meeting the power constraints. This work presents the development of an EMG and kinematic data capture wireless module, designed taking into account power consumption issues. This module captures and converts the analog myoeletric signal to digital, synchronously with the capture of kinetic information. Both data are time multiplexed and sent to a PC via Bluetooth link. The work carried out comprised the development of the hardware, the firmware and a graphical interface running in an external PC. The hardware was developed using the PIC18F14K22, a low power family of microcontrollers. The link was established via Bluetooth, a protocol designed for low power communication. An application was also developed to recover and trace the signal to a Graphic User Interface (GUI), coordinating the message exchange with the firmware. Results were obtained which allowed validating the conceived system in static and with the subject performing short movements. Although it was not possible to perform the tests within more dynamic movements, it is shown that it is possible to capture, transmit and display the captured data as expected. Some suggestions to improve the system performance also were made.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Presented at INForum - Simpósio de Informática (INFORUM 2015). 7 to 8, Sep, 2015. Portugal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Health promotion in hospital environments can be improved using the most recent information and communication technologies. The Internet connectivity to small sensor nodes carried by patients allows remote access to their bio-signals. To promote these features the healthcare wireless sensor networks (HWSN) are used. In these networks mobility support is a key issue in order to keep patients under realtime monitoring even when they move around. To keep sensors connected to the network, they should change their access points of attachment when patients move to a new coverage area along an infirmary. This process, called handover, is responsible for continuous network connectivity to the sensors. This paper presents a detailed performance evaluation study considering three handover mechanisms for healthcare scenarios (Hand4MAC, RSSI-based, and Backbone-based). The study was performed by simulation using several scenarios with different number of sensors and different moving velocities of sensor nodes. The results show that Hand4MAC is the best solution to guarantee almost continuous connectivity to sensor nodes with less energy consumption.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation to obtain the Master degree in Electrical Engineering and Computer Science

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development and application of a polyaniline/carbon nanotube (CNT) cyclodextrin matrix (PANI-β-CD/MWCNT)-based electrochemical sensor for the quantitative determination of the herbicide 4-chloro-2-methylphenoxyacetic acid (MCPA) and its main transformation product 4-chloro-2-methylphenol in natural waters are described. A simple cyclic voltammetry-based electrochemical methodology, in phosphate buffer solution at pH 6.0, was used to develop a method to determine both MCPA and 4-chloro-2-methylphenol, without any previous extraction or derivatization steps. A linear concentration range (10 to 50 μmol L−1) and detection limits of 1.1 and 1.9 μmol L−1, respectively, were achieved using optimized cyclic voltammetric parameters. The proposed method was successfully applied to the determination of MCPA and 4-chloro-2-methylphenol in natural water samples with satisfactory recoveries (94 to 107 %) and in good agreement with the results obtained by an established high-performance liquid chromatography technique, no significant differences being found between the methods. Interferences from ionic species and other herbicides used for broad-leaf weed control were shown to be small. The newly developed methodology was also successfully applied to MCPA photodegradation environmental studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente trabalho enquadra-se na área das redes de computadores, fazendo referência aos protocolos e ao conjunto de equipamentos e softwares necessários para a administração, controlo e monitorização desse tipo de infra-estruturas. Para a gestão de uma rede de dados, é essencial dispor de conhecimentos e documentação de nível técnico para representar da forma mais fiel possível a configuração da rede, seguindo passo a passo a interligação entre equipamentos existentes e oferecendo assim uma visão o mais fidedigna possível das instalações. O protocolo SNMP é utilizado em larga escala sendo praticamente um standard para a administração de redes baseadas na tecnologia TCP/IP. Este protocolo define a comunicação entre um administrador e um agente, estabelecendo o formato e o significado das mensagens trocadas entre ambos. Tem a capacidade de suportar produtos de diferentes fabricantes, permitindo ao administrador manter uma base de dados com informações relevantes da monitorização de vários equipamentos, que pode ser consultada e analisada por softwares NMS concebidos especialmente para a gestão de redes de computadores. O trabalho apresentado nesta dissertação teve como objectivo utilizar uma ferramenta NMS, para fazer a monitorização e a gestão da infra-estrutura de comunicações de forma que permitisse conhecer em tempo real o estado dos elementos de rede, ajudar no diagnóstico de possíveis problemas, instalados pela Nonius nos diversos navios da frota Douro Azul. O software NMS escolhido utiliza as potencialidades do protocolo SNMP para adquirir dados de monitorização de equipamentos de rede presentes na rede, bem como monitorizar redes remotas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O crescimento dos sistemas de informação e a sua utilização massiva criou uma nova realidade no acesso a experiências remotas que se encontram geograficamente distribuídas. Nestes últimos tempos, a temática dos laboratórios remotos apareceu nos mais diversos campos como o do ensino ou o de sistemas industriais de controlo e monitorização. Como o acesso aos laboratórios é efectuado através de um meio permissivo como é o caso da Internet, a informação pode estar à mercê de qualquer atacante. Assim, é necessário garantir a segurança do acesso, de forma a criar condições para que não se verifique a adulteração dos valores obtidos, bem como a existência de acessos não permitidos. Os mecanismos de segurança adoptados devem ter em consideração a necessidade de autenticação e autorização, sendo estes pontos críticos no que respeita à segurança, pois estes laboratórios podem estar a controlar equipamentos sensíveis e dispendiosos, podendo até eventualmente comprometer em certos casos o controlo e a monotorização de sistemas industriais. Este trabalho teve como objectivo a análise da segurança em redes, tendo sido realizado um estudo sobre os vários conceitos e mecanismos de segurança necessários para garantir a segurança nas comunicações entre laboratórios remotos. Dele resultam as três soluções apresentadas de comunicação segura para laboratórios remotos distribuídos geograficamente, recorrendo às tecnologias IPSec, OpenVPN e PPTP. De forma a minimizar custos, toda a implementação foi assente em software de código aberto e na utilização de um computador de baixo custo. No que respeita à criação das VPNs, estas foram configuradas de modo a permitir obter os resultados pretendidos na criação de uma ligação segura para laboratórios remotos. O pfSense mostrou-se a escolha acertada visto que suporta nativamente quaisquer das tecnologias que foram estudadas e implementadas, sem necessidade de usar recursos físicos muito caros, permitindo o uso de tecnologias de código aberto sem comprometer a segurança no funcionamento das soluções que suportam a segurança nas comunicações dos laboratórios remotos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we present ezGo, an electric powered wheelchair with a speech based interface and biosignal monitoring instrumentation. The user can use the voice, a natural communication method, for controlling the chair movement and obtain information about his health. Additionally a set of semi-autonomous modes with macro recording enable the execution of navigation tasks with little effort and improved precision. The main purpose of the system is to provide severely disabled persons with an assistive device that can improve their confidence and daily independence. The obtained results on usability tests showed that users consider ezGo a valuable help on their daily tasks and a very desirable addition to standard wheelchairs.