972 resultados para Ray Computed-tomography


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this work was to exemplify the specific contribution of both two- and three-dimensional (31)) X-ray computed tomography to characterise earthworm burrow systems. To achieve this purpose we used 3D mathematical morphology operators to characterise burrow systems resulting from the activity of an anecic (Aporrectodea noctunia), and an endogeic species (Allolobophora chlorotica), when both species were introduced either separately or together into artificial soil cores. Images of these soil cores were obtained using a medical X-ray tomography scanner. Three-dimensional reconstructions of burrow systems were obtained using a specifically developed segmentation algorithm. To study the differences between burrow systems, a set of classical tools of mathematical morphology (granulometries) were used. So-called granulometries based on different structuring elements clearly separated the different burrow systems. They enabled us to show that burrows made by the anecic species were fatter, longer, more vertical, more continuous but less sinuous than burrows of the endogeic species. The granulometry transform of the soil matrix showed that burrows made by A. nocturna were more evenly distributed than those of A. chlorotica. Although a good discrimination was possible when only one species was introduced into the soil cores, it was not possible to separate burrows of the two species from each other in cases where species were introduced into the same soil core. This limitation, partly due to the insufficient spatial resolution of the medical scanner, precluded the use of the morphological operators to study putative interactions between the two species.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To evaluate in chest X-rays and high-resolution computed tomographies of patients with pleural tuberculosis, the incidence of parenchymal and mediastinal lung lesions suggestive of active disease. Methods: Prospective study (2008-2009) evaluating the radiographic and tomographic abnormalities of 88 HIV-negative patients with pleural tuberculosis (unilateral effusion). The images were reviewed by 3 independent specialists, and the observed changes were classified according to previously established criteria: presence or absence of signs suggestive of disease activity, and nonspecific findings. Results: Abnormal changes were observed in chest X-rays of 22 (25%) patients and in the computed tomography of 55 (63%). Images compatible with active pulmonary tuberculosis were detected by radiography in 9 (10%) patients and by tomography in 38 (43%). Only 4 (4.5%) patients had tomography images suggestive of residual disease. Conclusion: The present study demonstrates that pulmonary involvement is quite common in pleural tuberculosis. This finding is mainly observed in high-resolution computed tomography and has important epidemiological implications, since patients with pleural tuberculosis are significant sources of infection and disease dissemination. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ultrasonic speed of propagation and attenuation were investigated as a function of absorbed radiation dose in PAG and MAGIC polymer gel dosimeters. Both PAG and MAGIC gel dosimeters displayed a dependence of ultrasonic parameters on absorbed dose with attenuation displaying significant changes in the dose range investigated. The ultrasonic attenuation dose sensitivity at 4 MHz in MAGIC gels was determined to be 4.7 +/- 0.3 dB m(-1) Gy(-1) and for PAG 3.9 +/- 0.3 dB m(-1) Gy(-1). Ultrasonic speed dose sensitivities were 0.178 +/- 0.006 m s(-1) Gy(-1) for MAGIC gel and -0.44 +/- 0.02 m s(-1) Gy(-1) for PAG. Density and compressional elastic modulus were investigated to explain the different sensitivities of ultrasonic speed to radiation for PAG and MAGIC gels. The different sensitivities were found to be due to differences in the compressional elastic modulus as a function of dose for the two formulations. To understand the physical phenomena underlying the increase in ultrasonic attenuation with dose, the viscoelastic properties of the gels were studied. Results suggest that at ultrasonic frequencies, attenuation in polymer gel dosimeters is primarily due to volume viscosity. It is concluded that ultrasonic attenuation significantly increases with absorbed dose. Also, the ultrasonic speed in polymer gel dosimeters is affected by changes in dosimeter elastic modulus that are likely to be a result of polymerization. It is suggested that ultrasound is a sufficiently sensitive technique for polymer gel dosimetry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lean meat percentage (LMP) is the criterion for carcass classification and it must be measured on line objectively. The aim of this work was to compare the error of the prediction (RMSEP) of the LMP measured with the following different devices: Fat-O-Meat’er (FOM), UltraFOM (UFOM), AUTOFOM and -VCS2000. For this reason the same 99 carcasses were measured using all 4 apparatus and dissected according to the European Reference Method. Moreover a subsample of the carcasses (n=77) were fully scanned with a X-ray Computed Tomography equipment (CT). The RMSEP calculated with cross validation leave-one-out was lower for FOM and AUTOFOM (1.8% and 1.9%, respectively) and higher for UFOM and VCS2000 (2.3% for both devices). The error obtained with CT was the lowest (0.96%) in accordance with previous results, but CT cannot be used on line. It can be concluded that FOM and AUTOFOM presented better accuracy than UFOM and VCS2000.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Adoptive transfer therapy of in vitro-expanded tumor-specific cytolytic T lymphocytes (CTLs) can mediate objective cancer regression in patients. Yet, technical limitations hamper precise monitoring of posttherapy T cell responses. Here we show in a mouse model that fused single photon emission computed tomography and x-ray computed tomography allows quantitative whole-body imaging of (111)In-oxine-labeled CTLs at tumor sites. Assessment of CTL localization is rapid, noninvasive, three-dimensional, and can be repeated for longitudinal analyses. We compared the effects of lymphodepletion before adoptive transfer on CTL recruitment and report that combined treatment increased intratumoral delivery of CTLs and improved antitumor efficacy. Because (111)In-oxine is a Food and Drug Administration-approved clinical agent, and human SPECT-CT systems are available, this approach should be clinically translatable, insofar as it may assess the efficacy of immunization procedures in individual patients and lead to development of more effective therapies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: Adenoma is the main parathyroid disorder leading to primary hyperparathyroidism (PHP). Minimally invasive parathyroidectomy (MIP) is recognized as a valid procedure for adenoma-related PHP. It requires precise preoperative localization combining Tc-99m-MIBI (methoxy-isobutyl-isonitrile) scintigraphy and single-photon emission computed tomography (SPECT) with x-ray computed tomography (CT) and intraoperative confirmation of successful excision by change in intact parathormone (iPTH) levels. The study aim was to assess the surgery success in relation to these two parameters. METHODS: All patients operated on for PHP from 2005 to mid-2014 at our institution were retrospectively reviewed. MIP was performed in case of precise preoperative adenoma localization on scintigraphy, absence of past cervical surgery, and absence of concomitant thyroid resection necessity. In these patients, iPTH levels were monitored intraoperatively. Confirmation criteria for iPTH values were a return to normal level or a decrease >50 % of basal iPTH level. RESULTS: There were 197 PHP operations during the study period: 118 MIP and 79 bilateral neck explorations (BNEs). The MIP success rate was 95 % (112/118) with a preoperative MIBI scan ± CT accurate in 94 % (111/118) of the patients and with correct iPTH in 90 % (106/118) of the cases. Among the 12 iPTH levels that did not meet the confirmation criteria, 10 returned to normal range by postoperative day 2. Treatment failure appeared in three patients (one BNE, two MIPs). CONCLUSIONS: Tc-99m-MIBI dual-phase scintigraphy with SPECT/CT is the key examination for functional and morphological parathyroid adenoma localization. If preoperative scintigraphy is obvious and intraoperative assessment is clear, one could possibly safely omit iPTH, as it may lead to unnecessary BNE in primary PHP.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

X-ray computed log tomography has always been applied for qualitative reconstructions. In most cases, a series of consecutive slices of the timber are scanned to estimate the 3D image reconstruction of the entire log. However, the unexpected movement of the timber under study influences the quality of image reconstruction since the position and orientation of some scanned slices can be incorrectly estimated. In addition, the reconstruction time remains a significant challenge for practical applications. The present study investigates the possibility to employ modern physics engines for the problem of estimating the position of a moving rigid body and its scanned slices which are subject to X-ray computed tomography. The current work includes implementations of the extended Kalman filter and an algebraic reconstruction method for fan-bean computer tomography. In addition, modern techniques such as NVidia PhysX and CUDA are used in current study. As the result, it is numerically shown that it is possible to apply the extended Kalman filter together with a real-time physics engine, known as PhysX, in order to determine the position of a moving object. It is shown that the position of the rigid body can be determined based only on reconstructions of its slices. However, the simulation of the body movement sometimes is subject to an error during Kalman filter employment as PhysX is not always able to continue simulating the movement properly because of incorrect state estimation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: o presente estudo, de caráter prospectivo, objetivou avaliar a imagem da sutura palatina mediana em crianças submetidas à expansão rápida da maxila por meio de tomografia computadorizada, após a fase de contenção. METODOLOGIA: a amostra constou de 17 crianças de ambos os gêneros, na faixa etária compreendida entre 5 anos e 2 meses e 10 anos e 5 meses no início do tratamento, provenientes da Clínica de Ortodontia Interceptiva da Sociedade de Promoção Social do Fissurado Lábio-Palatal da Universidade de São Paulo (PROFIS-USP), Bauru/SP. Tomografias computadorizadas foram implementadas para avaliar o comportamento da sutura palatina mediana em diferentes momentos do tratamento. RESULTADOS E CONCLUSÕES: constatou-se que, após um período médio de 8 a 9 meses de contenção com o aparelho expansor, a sutura palatina mediana mostrou-se completamente ossificada, desde a região da espinha nasal anterior até a espinha nasal posterior. Tal informação esclarece o comportamento da sutura palatina mediana frente à expansão rápida da maxila e reitera o senso comum quanto ao caráter biológico do procedimento.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Proton radiation therapy is a precise form of radiation therapy, but the avoidance of damage to critical normal tissues and the prevention of geographical tumor misses require accurate knowledge of the dose delivered to the patient and the verification of his position demand a precise imaging technique. In proton therapy facilities, the X-ray Computed Tomography (xCT) is the preferred technique for the planning treatment of patients. This situation has been changing nowadays with the development of proton accelerators for health care and the increase in the number of treated patients. In fact, protons could be more efficient than xCT for this task. One essential difficulty in pCT image reconstruction systems came from the scattering of the protons inside the target due to the numerous small-angle deflections by nuclear Coulomb fields. The purpose of this study is the comparison of an analytical formulation for the determination of beam lateral deflection, based on Molière's theory and Rutherford scattering with Monte Carlo calculations by SRIM 2008 and MCNPX codes. © 2010 American Institute of Physics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the accuracy of virtual three-dimensional (3D) reconstructions of human dry mandibles, produced from two segmentation protocols (outline only and all-boundary lines).Twenty virtual three-dimensional (3D) images were built from computed tomography exam (CT) of 10 dry mandibles, in which linear measurements between anatomical landmarks were obtained and compared to an error probability of 5 %.The results showed no statistically significant difference among the dry mandibles and the virtual 3D reconstructions produced from segmentation protocols tested (p = 0,24).During the designing of a virtual 3D reconstruction, both outline only and all-boundary lines segmentation protocols can be used.Virtual processing of CT images is the most complex stage during the manufacture of the biomodel. Establishing a better protocol during this phase allows the construction of a biomodel with characteristics that are closer to the original anatomical structures. This is essential to ensure a correct preoperative planning and a suitable treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Carbon fiber reinforced carbon composites can be made by iterative liquid impregnation or gas phase carbon deposition routes. In both cases, at the final processing stage the carbon fiber is embedded in carbon matrix which results in unique properties such as low density, high thermal conductivity and thermal shock resistance, low thermal expansion and high modulus, in relation to other refractory materials. In the present study assembled three-directional and four-directional preforms, having 50% volume of pores, were densified by iterative cycles of thermoset resin impregnation followed by pyrolysis under inert atmosphere, until appropriate densities were achieved. The thermoset resin is converted in a carbon matrix during pyrolysis. The iterative manufacturing process of the carbon fiber reinforced carbon composites is evaluated by means of nondestructive techniques based on X-ray computed tomography and electrical resistivity. X-ray computed tomography gives a general mapping view of the filling pores of the preforms which impacts results of the electrical resistivity. After six processing cycles and heat treatments up to 2000?, the final densities of the three-directional and four-directional carbon fiber reinforced carbon composites were 1.16g/cm(3) and an electrical resistivity of approximate to 0.07m. The configuration of preforms, three-directional or four-directional, did not alter the densification profile, in terms of increasing density and reducing porosity during the processing cycles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Research on the micro-structural characterization of metal-matrix composites uses X-ray computed tomography to collect information about the interior features of the samples, in order to elucidate their exhibited properties. The tomographic raw data needs several steps of computational processing in order to eliminate noise and interference. Our experience with a program (Tritom) that handles these questions has shown that in some cases the processing steps take a very long time and that it is not easy for a Materials Science specialist to interact with Tritom in order to define the most adequate parameter values and the proper sequence of the available processing steps. For easing the use of Tritom, a system was built which addresses the aspects described before and that is based on the OpenDX visualization system. OpenDX visualization facilities constitute a great benefit to Tritom. The visual programming environment of OpenDX allows an easy definition of a sequence of processing steps thus fulfilling the requirement of an easy use by non-specialists on Computer Science. Also the possibility of incorporating external modules in a visual OpenDX program allows the researchers to tackle the aspect of reducing the long execution time of some processing steps. The longer processing steps of Tritom have been parallelized in two different types of hardware architectures (message-passing and shared-memory); the corresponding parallel programs can be easily incorporated in a sequence of processing steps defined in an OpenDX program. The benefits of our system are illustrated through an example where the tool is applied in the study of the sensitivity to crushing – and the implications thereof – of the reinforcements used in a functionally graded syntactic metallic foam.