987 resultados para Polyharmonic order of precision


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nowadays, different techniques are available for manufacturing full-arch implant-supported prosthesis, many of them based on an impression procedure. Nevertheless, the long-term success of the prosthesis is highly influenced by the accuracy during such process, being affected by factors such as the impression material, implant position, angulation and depth. This paper investigates the feasibility of a 3D electromagnetic motion tracking system as an acquisition method for modeling such prosthesis. To this extent, we propose an implant acquisition method at the patient mouth, using a specific prototyped tool coupled with a tracker sensor, and a set of calibration procedures (for distortion correction and tool calibration), that ultimately obtains combined measurements of the implant’s position and angulation, and eliminating the use of any impression material. However, in the particular case of the evaluated tracking system, the order of magnitude of the obtained errors invalidates its use for this specific application.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The success of the osseointegration concept and the Brånemark protocol is highly associated to the accuracy in the production of an implant-supported prosthesis. One of most critical steps for long-term success of these prosthesis is the accuracy obtained during the impression procedure, which is affected by factors such as the impression material, implant position, angulation and depth. This paper investigates the feasibility of 3D electromagnetic motion tracking systems as an acquisition method for modeling full-arch implant-supported prosthesis. To this extent, we propose an implant acquisition method at the patient mouth and a calibration procedure, based on a 3D electromagnetic tracker that obtains combined measurements of implant’s position and angulation, eliminating the use of any impression material. Three calibration algorithms (namely linear interpolation, higher-order polynomial and Hardy multiquadric) were tested to compensate for the electromagnetic tracker distortions introduced by the presence of nearby metals. Moreover, implants from different suppliers were also tested to study its impact on tracking accuracy. The calibration methodology and the algorithms employed proved to implement a suitable strategy for the evaluation of novel dental impression techniques. However, in the particular case of the evaluated electromagnetic tracking system, the order of magnitude of the obtained errors invalidates its use for the full-arch modeling of implant-supported prosthesis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction and Objectives. Laparoscopic surgery has undeniable advantages, such as reduced postoperative pain, smaller incisions, and faster recovery. However, to improve surgeons’ performance, ergonomic adaptations of the laparoscopic instruments and introduction of robotic technology are needed. The aim of this study was to ascertain the influence of a new hand-held robotic device for laparoscopy (HHRDL) and 3D vision on laparoscopic skills performance of 2 different groups, naïve and expert. Materials and Methods. Each participant performed 3 laparoscopic tasks—Peg transfer, Wire chaser, Knot—in 4 different ways. With random sequencing we assigned the execution order of the tasks based on the first type of visualization and laparoscopic instrument. Time to complete each laparoscopic task was recorded and analyzed with one-way analysis of variance. Results. Eleven experts and 15 naïve participants were included. Three-dimensional video helps the naïve group to get better performance in Peg transfer, Wire chaser 2 hands, and Knot; the new device improved the execution of all laparoscopic tasks (P < .05). For expert group, the 3D video system benefited them in Peg transfer and Wire chaser 1 hand, and the robotic device in Peg transfer, Wire chaser 1 hand, and Wire chaser 2 hands (P < .05). Conclusion. The HHRDL helps the execution of difficult laparoscopic tasks, such as Knot, in the naïve group. Three-dimensional vision makes the laparoscopic performance of the participants without laparoscopic experience easier, unlike those with experience in laparoscopic procedures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The deficiency of essential micronutrients and excess of toxic metals in cereals, an important food items for human nutrition, can cause public health risk. Therefore, before their consumption and adoption of soil supplementation, concentrations of essential micronutrients and metals in cereals should be monitored. This study collected soil and two varieties of wheat samples–Triticum aestivum L. (Jordão/bread wheat), and Triticum durum L. (Marialva/durum wheat) from Elvas area, Portugal and analyzed concentrations of As, Cr, Co, Fe, K, Na, Rb and Zn using Instrumental Neutron Activation Analysis (INAA) to focus on the risk of adverse public health issues. The low variability and moderate concentrations of metals in soils indicated a lower significant effect of environmental input on metal concentrations in agricultural soils. The Cr and Fe concentrations in soils that ranged from 93–117 and 26,400–31,300 mg/kg, respectively, were relatively high, but Zn concentration was very low (below detection limit <22 mg/kg) indicating that soils should be supplemented with Zn during cultivation. The concentrations of metals in roots and straw of both varieties of wheat decreased in the order of K>Fe>Na>Zn>Cr>Rb>As>Co. Concentrations of As, Co and Cr in root, straw and spike of both varieties were higher than the permissible limits with exception of a few samples. The concentrations of Zn in root, straw and spike were relatively low (4–30 mg/kg) indicating the deficiency of an essential micronutrient Zn in wheat cultivated in Portugal. The elemental transfer from soil to plant decreases with increasing growth of the plant. The concentrations of various metals in different parts of wheat followed the order: Root>Straw>Spike. A few root, straw and spike samples showed enrichment of metals, but the majority of the samples showed no enrichment. Potassium is enriched in all samples of root, straw and spike for both varieties of wheat. Relatively to the seed used for cultivation, Jordão presented higher transfer coefficients than Marialva, in particular for Co, Fe, and Na. The Jordão and Marialva cultivars accumulated not statistically significant different concentrations of different metals. The advantages of using INAA are the multielementality, low detection limits and use of solid samples (no need of digestion).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Link do editor: http://www.igi-global.com/chapter/role-lifelong-learning-creation-european/13314

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The dominant discourse in education and training policies, at the turn of the millennium, was on lifelong learning (LLL) in the context of a knowledge-based society. As Green points (2002, pp. 611-612) several factors contribute to this global trend: The demographic change: In most advanced countries, the average age of the population is increasing, as people live longer; The effects of globalisation: Including both economic restructuring and cultural change which have impacts on the world of education; Global economic restructuring: Which causes, for example, a more intense demand for a higher order of skills; the intensified economic competition, forcing a wave of restructuring and creating enormous pressure to train and retrain the workforce In parallel, the “significance of the international division of labour cannot be underestimated for higher education”, as pointed out by Jarvis (1999, p. 250). This author goes on to argue that globalisation has exacerbated differentiation in the labour market, with the First World converting faster to a knowledge economy and a service society, while a great deal of the actual manufacturing is done elsewhere.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Five new silver(I) complexes of formulas [Ag(Tpms)] (1), [Ag(Tpms)-(PPh3)] (2), [Ag(Tpms)(PCy3)] (3), [Ag(PTA)][BF4] (4), and [Ag(Tpms)(PTA)] (5) {Tpms = tris(pyrazol-1-yl)methanesulfonate, PPh3 = triphenylphosphane, PCy3 = tricyclohexylphosphane, PTA = 1,3,5-triaza-7-phosphaadamantane) have been synthesized and fully characterized by elemental analyses, H-1, C-13, and P-31 NMR, electrospray ionization mass spectrometry (ESI-MS), and IR spectroscopic techniques. The single crystal X-ray diffraction study of 3 shows the Tpms ligand acting in the N-3-facially coordinating mode, while in 2 and 5 a N2O-coordination is found, with the SO3 group bonded to silver and a pendant free pyrazolyl ring. Features of the tilting in the coordinated pyrazolyl rings in these cases suggest that this inequivalence is related with the cone angles of the phosphanes. A detailed study of antimycobacterial and antiproliferative properties of all compounds has been carried out. They were screened for their in vitro antimicrobial activities against the standard strains Enterococcus faecalis (ATCC 29922), Staphylococcus aureus (ATCC 25923), Streptococcus pneumoniae (ATCC 49619), Streptococcus pyogenes (SF37), Streptococcus sanguinis (SK36), Streptococcus mutans (UA1S9), Escherichia coli (ATCC 25922), and the fungus Candida albicans (ATCC 24443). Complexes 1-5 have been found to display effective antimicrobial activity against the series of bacteria and fungi, and some of them are potential candidates for antiseptic or disinfectant drugs. Interaction of Ag complexes with deoxyribonucleic acid (DNA) has been studied by fluorescence spectroscopic techniques, using ethidium bromide (EB) as a fluorescence probe of DNA. The decrease in the fluorescence of DNA EB system on addition of Ag complexes shows that the fluorescence quenching of DNA EB complex occurs and compound 3 is particularly active. Complexes 1-5 exhibit pronounced antiproliferative activity against human malignant melanoma (A375) with an activity often higher than that of AgNO3, which has been used as a control, following the same order of activity inhibition on DNA, i.e., 3 > 2 > 1 > 5 > AgNO3 >> 4.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Projeto de Intervenção apresentado à Escola Superior de Educação de Lisboa para obtenção do grau de Mestre em Didática da Língua Portuguesa no 1.º e 2.º Ciclo do Ensino Básico

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Here we report on the structural, optical, electrical and magnetic properties of Co-doped and (Co,Mo)-codoped SnO2 thin films deposited on r-cut sapphire substrates by pulsed laser deposition. Substrate temperature during deposition was kept at 500 degrees C. X-ray diffraction analysis showed that the undoped and doped films are crystalline with predominant orientation along the [1 0 1] direction regardless of the doping concentration and doping element. Optical studies revealed that the presence of Mo reverts the blue shift trend observed for the Co-doped films. For the Co and Mo doping concentrations studied, the incorporation of Mo did not contribute to increase the conductivity of the films or to enhance the ferromagnetic order of the Co-doped films. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The deterioration of water quality by Cyanobacteria cause outbreaks and epidemics associated with harmful diseases in Humans and animals because of the toxins that they release. Microcystin-LR is one of the hepatotoxins most widely studied and the World Health Organization, recommend a maximum value of 1mgL 1 in drinking water. Highly specific recognition molecules, such as molecular imprinted polymers are developed to quantify microcystins in waters for human use and shown to be of great potential in the analysis of these kinds of samples. The obtained results were auspicious, the detection limit found, 1.5mgL 1, being of the same order of magnitude as the guideline limit recommended by the WHO. This technology is very promising because the sensors are stable and specific, and the technology is inexpensive and allows for rapid on-site monitoring.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The main objective of this research is to exploit the possibility of using an ex situ solvent extraction technique for the remediation of soils contaminated with semi-volatile petroleum hydrocarbons. The composition of the organic phase was chosen in order to form a single phase mixture with an aqueous phase and simultaneously not being disturbed (forming stable emulsions) by the soil particles hauling the contaminants. It should also permit a regeneration of the organic solvent phase. As first, we studied the miscibility domain of the chosen ternary systems constituted by ethyl acetate–acetone–water. This system proved to satisfy the previous requirements allowing for the formation of a single liquid phase mixture within a large spectrum of compositions, and also allowing for an intimate contact with the soil. Contaminants in the diesel range within different functional groups were selected: xylene, naphthalene and hexadecane. The analytical control was done by gas chromatography with FID detector. The kinetics of the extractions proved to be fast, leading to equilibrium after 10 min. The effect of the solid–liquid ratio on the extraction efficiency was studied. Lower S/L ratios (1:8, w/v) proved to be more efficient, reaching recoveries in the order of 95%. The option of extraction in multiple contacts did not improve the recovery in relation to a single contact. The solvent can be regenerated by distillation with a loss around 10%. The contaminants are not evaporated and they remain in the non-volatile phase. The global results show that the ex situ solvent extraction is technically a feasible option for the remediation of semi-volatile aromatic, polyaromatic and linear hydrocarbons.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Zero valent iron (ZVI) has been extensively used as a reactive medium for the reduction of Cr(VI) to Cr(III) in reactive permeable barriers. The kinetic rate depends strongly on the superficial oxidation of the iron particles used and the preliminary washing of ZVI increases the rate. The reaction has been primarily modelled using a pseudo-first-order kinetics which is inappropriate for a heterogeneous reaction. We assumed a shrinking particle type model where the kinetic rate is proportional to the available iron surface area, to the initial volume of solution and to the chromium concentration raised to a power ˛ which is the order of the chemical reaction occurring at surface. We assumed α= 2/3 based on the likeness to the shrinking particle models with spherical symmetry. Kinetics studies were performed in order to evaluate the suitability of this approach. The influence of the following parameters was experimentally studied: initial available surface area, chromium concentration, temperature and pH. The assumed order for the reaction was confirmed. In addition, the rate constant was calculated from data obtained in different operating conditions. Digital pictures of iron balls were periodically taken and the image treatment allowed for establishing the time evolution of their size distribution.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In life cycle impact assessment (LCIA) models, the sorption of the ionic fraction of dissociating organic chemicals is not adequately modeled because conventional non-polar partitioning models are applied. Therefore, high uncertainties are expected when modeling the mobility, as well as the bioavailability for uptake by exposed biota and degradation, of dissociating organic chemicals. Alternative regressions that account for the ionized fraction of a molecule to estimate fate parameters were applied to the USEtox model. The most sensitive model parameters in the estimation of ecotoxicological characterization factors (CFs) of micropollutants were evaluated by Monte Carlo analysis in both the default USEtox model and the alternative approach. Negligible differences of CFs values and 95% confidence limits between the two approaches were estimated for direct emissions to the freshwater compartment; however the default USEtox model overestimates CFs and the 95% confidence limits of basic compounds up to three orders and four orders of magnitude, respectively, relatively to the alternative approach for emissions to the agricultural soil compartment. For three emission scenarios, LCIA results show that the default USEtox model overestimates freshwater ecotoxicity impacts for the emission scenarios to agricultural soil by one order of magnitude, and larger confidence limits were estimated, relatively to the alternative approach.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE Translate the Patient-centered Assessment and Counseling for Exercise questionnaire, adapt it cross-culturally and identify the psychometric properties of the psychosocial scales for physical activity in young university students.METHODS The Patient-centered Assessment and Counseling for Exercise questionnaire is made up of 39 items divided into constructs based on the social cognitive theory and the transtheoretical model. The analyzed constructs were, as follows: behavior change strategy (15 items), decision-making process (10), self-efficacy (6), support from family (4), and support from friends (4). The validation procedures were conceptual, semantic, operational, and functional equivalences, in addition to the equivalence of the items and of measurements. The conceptual, of items and semantic equivalences were performed by a specialized committee. During measurement equivalence, the instrument was applied to 717 university students. Exploratory factor analysis was used to verify the loading of each item, explained variance and internal consistency of the constructs. Reproducibility was measured by means of intraclass correlation coefficient.RESULTS The two translations were equivalent and back-translation was similar to the original version, with few adaptations. The layout, presentation order of the constructs and items from the original version were kept in the same form as the original instrument. The sample size was adequate and was evaluated by the Kaiser-Meyer-Olkin test, with values between 0.72 and 0.91. The correlation matrix of the items presented r < 0.8 (p < 0.05). The factor loadings of the items from all the constructs were satisfactory (> 0.40), varying between 0.43 and 0.80, which explained between 45.4% and 59.0% of the variance. Internal consistency was satisfactory (α ≥ 0.70), with support from friends being 0.70 and 0.92 for self-efficacy. Most items (74.3%) presented values above 0.70 for the reproducibility test.CONCLUSIONS The validation process steps were considered satisfactory and adequate for applying to the population.