985 resultados para Plasma membranes
Resumo:
Dissertation presented to Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa for obtaining the master degree in Membrane Engineering
Resumo:
Dissertation presented to Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa for obtaining the master degree in Membrane Engineering
Longitudinal comparison between plasma and seminal HIV-1 viral loads during antiretroviral treatment
Resumo:
This study was designed to investigate the impact of anti-retroviral therapy on both plasma and seminal HIV-1 viral loads and the correlation between viral loads in these compartments after treatment. Viral load, CD4+ and CD8+ T-cell counts were evaluated in paired plasma and semen samples from 36 antiretroviral therapy-naïve patients at baseline and on days 45, 90, and 180 of treatment. Slopes for blood and seminal viral loads in all treated patients were similar (p = 0.21). Median HIV-1 RNA titers in plasma and semen at baseline were 4.95 log10 and 4.48 log10 copies/ml, respectively. After 180 days of therapy, the median viral load declined to 3.15 log10 copies/ml (plasma) and 3.2 log10 copies/ml (semen). At this timepoint 22 patients presented HIV-1 viral load below 400 copies/ml in either plasma or semen, but only 9 had viral loads below 400 copies/ml in both compartments.
Resumo:
Pouco se conhece a cerca de alterações nos lipídeos plasmáticos devido à reinfecção por Schistosoma mansoni. Neste trabalho, foram avaliadas alterações nos lipídeos plasmáticos decorrentes de uma reinfecção por Schistosoma mansoni no primata não humano Callithrix jacchus (sagüi). Amostras de sangue dos animais, antes e após serem infectados e reinfectados, foram coletadas por punção venosa, anticoaguladas com EDTA (1mg/mL) e centrifugadas a 2.500xg para obtenção do plasma. Os níveis plasmáticos de colesterol total, colesterol éster, fosfolipídeo total e triglicerídeo foram determinados por métodos espectrofotométricos. Os resultados mostraram haver redução significativa nas concentrações de colesterol total, colesterol esterificado, triglicerídeo e fosfolipídeo total em plasma de animais reinfectados por Schistosoma mansoni, em comparação com os mesmos animais antes da infecção e após uma infecção. Este estudo mostra que uma segunda infecção por Schistosoma mansoni causa alterações lipídicas plasmáticas significativamente mais acentuadas que as decorrentes de uma única infecção.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Química e Bioquímica
Resumo:
Fundação para a Ciência e a Tecnologia (FCT-MCTES) under the grant SFRH/BD/69306/2010
Resumo:
In the field of energy, natural gas is an essential bridge to a clean, low carbon, renewable energy era. However, natural gas processing and transportation regulation require the removal of contaminant compounds such as carbon dioxide (CO2). Regarding clean air, the increasing atmospheric concentrations of greenhouse gases, specifically CO2, is of particular concern. Therefore, new costeffective, high performance technologies for carbon capture have been researched and the design of materials with the ability to efficiently separate CO2 from other gases is of vital importance.(...)
Resumo:
INTRODUCTION: The present study investigated the association between mannose-binding lectin (MBL) gene polymorphism and serum levels with infection by HIV-1. METHODS: Blood samples (5mL) were collected from 97 HIV-1-infected individuals resident in Belém, State of Pará, Brazil, who attended the Special Outpatient Unit for Infections and Parasitic Diseases (URE-DIPE). CD4+ T-lymphocyte count and plasma viral load were quantified. A 349bp fragment of exon 1 of the MBL was amplified via PCR, using genomic DNA extracted from controls and HIV-1-infected individuals, following established protocols. MBL plasma levels of the patients were quantified using an enzyme immunoassay kit. RESULTS: Two alleles were observed: MBL*O, with a frequency of 26.3% in HIV-1-infected individuals; and the wild allele MBL*A (73.7%). Similar frequencies were observed in the control group (p > 0.05). Genotype frequencies were distributed according to the Hardy-Weinberg equilibrium in both groups. Mean MBL plasma levels varied by genotype, with statistically significant differences between the AA and AO (p < 0.0001), and AA and OO (p < 0.001) genotypes, but not AO and OO (p = 0.17). Additionally, CD4+ T-lymphocytes and plasma viral load levels did not differ significantly by genotype (p > 0.05). CONCLUSIONS: The results of this study do not support the hypothesis that MBL gene polymorphism or low plasma MBL concentrations might have a direct influence on HIV-1 infection, although a broader study involving a large number of patients is needed.
Resumo:
Segundo a Organização Mundial da Saúde (OMS), as doenças cardiovasculares (DCV) são a principal causa de morte nos países desenvolvidos. Há uma necessidade urgente de métodos eficazes para a detecção precoce de doenças cardiovasculares, devido à falta de factores de risco convencionais. Os níveis elevados de homocisteína (Hcy) no sangue, homocisteinemia, são um factor de risco independente bem estabelecido para DCV. De acordo com alguns autores, a conversão metabólica de Hcy no metabolito tóxico Hcy-Tl e subsequente N-homocisteinilação de proteínas induz a agregação e a formação de amiloide, contribuindo assim para a alterações próaterogénicas no sistema cardiovascular. A enzima associada à lipoproteína de alta densidade (HDL), paraoxonase 1 (PON1), é capaz de hidrolisar o metabolito tóxico Hcy-Tl de volta a Hcy no soro humano, como observado em estudos recentes que indicam o papel de patogénese em DCV da hPON1. As paraoxonases de soro (PON1, PON2 e PON3) são hidrolases dependentes de cálcio, que pertencem a uma família de enzimas que exibem propriedades antioxidantes e anti-inflamatórias. Foram identificadas três actividades catalíticas principais para PON1: (i) actividade paraoxonase, que corresponde à conversão hidrolítica de paraoxon em p-nitrofenol e a dietil fosfato, (ii) a actividade arilesterase que promove a hidrólise de ésteres aromáticos, e a (iii) actividade de lactonase, que catalisa a hidrólise de Hcy a Hcy-Tl, sendo considerada a actividade principal da PON1. Vários estudos têm relacionado estas actividades enzimáticas a diversas patologias, o que sugere a sua potencial utilidade no diagnóstico clínico. Neste trabalho pretende-se desenvolver um novo método electroquímico para a detecção fácil do substrato e produto resultantes da hidrólise enzimática de paraoxon pela hPON1. Utilizando uma célula electroquímica constituída por um eléctrodo de referência Ag /AgCl., um contra-eléctrodo de Pt e um electrodo de trabalho de carbono vítreo, o paraoxon e p-nitrofenol foram detectados simultaneamente por voltametria de onda quadrada, numa janela de potencial de [-0,3;-1,2] V. Os resultados dos ensaios com a enzima testada a pH 7,6 e 37°C, na presença de paraoxon e utilizando plasma humano como uma fonte de PON1 serão discutidos. Usando a mesma composição de célula electroquímica, Hcy e Hcy-Tl foram estudados utilizando diferentes interfaces e tipos de tratamento para testar a melhor maneira possível de detecção das duas espécies na mesma experiência electroquímica.
Resumo:
Fluid management and dosage regimens of drugs in preterm infants should be based on the glomerular filtration rate. The current methods to determine glomerular flitration rate are invasive, time-consuming, and expensive. In contrast, creatinine clearance can be easy obtained and quickly determined. The purpose of this study was to compare plasma creatinine on the third and seventh day of life in preterm newborn infants, to evaluate the influence of maternal creatinine, and to demonstrate creatinine clearance can be used as a reliable indicator of glomerular filtration rate. We developed a prospective study (1994) including 40 preterm newborns (gestational age < 37 weeks), average = 34 weeks; birth weight (average) = 1840 g, in the first week of life. Inclusion criteria consisted of: absence of renal and urinary tract anomalies; O2 saturation 3 92%; adequate urine output (>1ml/kg/hr); normal blood pressure; absence of infections and no sympathomimetic amines in use. A blood sample was collected to determine plasma creatinine (enzymatic method) on the third and seventh day of life and creatinine clearance (CrCl) was obtained using the following equation: , k = 0.33 in preterm infant All plasma creatinine determinations showed normal values [third day: 0.78 mg/dl ± 0.24 (mean ± SD)and seventh day: 0.67 mg/dl ± 0.31 - (p>0.05)]. Also all creatinine clearance at third and seventh day of life were normal [third day: 19.5 ml/min ± 5.2 (mean ± SD) and seventh day: 23.8 ml/min ± 7.3 - (p>0,05)]. All preterm infants developed adequate renal function for their respective gestational age. In summary, our results indicate that, for clinical practice, the creatinine clearance, using newborn length, can be used to estimate glomerular filtration rate in preterm newborn infants.
Resumo:
Al-Cu alloys are widely used in the aerospace and automotive industries due to their high specific strength in some tempered conditions. However, due to poor corrosion and wear resistance, they are often anodized and/or painted. Plasma nitriding has been proposed as an alternative, though the developments in this technique are still in a recent stage for Al alloys. Electrical characterization techniques are well implemented NDTs in the industry because of good accuracy associated with lower cost, compared to other methods. Some, like eddy currents and 4-point probe techniques, are often used in coating inspection. The objective of this study was to perform Al nitriding at low temperatures to minimize the tempering initial condition damage and to assess the feasibility of eddy currents technique as a method for evaluating surface properties. The work developed can be divided in two stages. The first one was the process tuning, done at the Shibaura Institute of Technology, in Tokyo; and the second was the electrical characterization done in Faculdade de Ciências e Tecnologia, UNL. Low temperature nitriding of AA2011 alloy specimens was successfully achieved. Electrical conductivity results show that lift-off measurements by eddy currents testing can be related to surface properties.
Resumo:
The work presented in this thesis aims at developing a new separation process based on the application of supported magnetic ionic liquid membranes, SMILMs, using magnetic ionic liquids, MILs. MILs have attracted growing interest due to their ability to change their physicochemical characteristics when exposed to variable magnetic field conditions. The magnetic responsive behavior of MILs is thus expected to contribute for the development of more efficient separation processes, such as supported liquid membranes, where MILs may be used as a selective carrier. Driven by the MILs behavior, these membranes are expected to switch reversibly their permeability and selectivity by in situ and non-invasive adjustment of the conditions (e.g. intensity, direction vector and uniformity) of an external applied magnetic field. The development of these magnetic responsive membrane processes were anticipated by studies, performed along the first stage of this PhD work, aiming at getting a deep knowledge on the influence of magnetic field on MILs properties. The influence of the magnetic field on the molecular dynamics and structural rearrangement of MILs ionic network was assessed through a 1H-NMR technique. Through the 1H-NMR relaxometry analysis it was possible to estimate the self-diffusion profiles of two different model MILs, [Aliquat][FeCl4] and [P66614][FeCl4]. A comparative analysis was established between the behavior of magnetic and non-magnetic ionic liquids, MILs and ILs, to facilitate the perception of the magnetic field impact on MILs properties. In contrast to ILs, MILs show a specific relaxation mechanism, characterized by the magnetic dependence of their self-diffusion coefficients. MILs self-diffusion coefficients increased in the presence of magnetic field whereas ILs self-diffusion was not affected. In order to understand the reasons underlying the magnetic dependence of MILs self-diffusion, studies were performed to investigate the influence of the magnetic field on MILs’ viscosity. It was observed that the MIL´s viscosity decreases with the increase of the magnetic field, explaining the increase of MILs self-diffusion according to the modified Stokes- Einstein equation. Different gas and liquid transport studies were therefore performed aiming to determine the influence of the magnetic behavior of MILs on solute transport through SMILMs. Gas permeation studies were performed using pure CO2 andN2 gas streams and air, using a series of phosphonium cation based MILs, containing different paramagnetic anions. Transport studies were conducted in the presence and absence of magnetic field at a maximum intensity of 1.5T. The results revealed that gas permeability increased in the presence of the magnetic field, however, without affecting the membrane selectivity. The increase of gas permeability through SMILMs was related to the decrease of the MILs viscosity under magnetic field conditions.(...)
Resumo:
Implantable devices must exhibit mechanical properties similar to native tissues to promote appropriate cellular behavior and regeneration. Herein, we report a new membrane manufacture method based on the synthesis of polyelectrolyte complexes (PECs) that exhibit saloplasticity, i.e. variable physical-chemistry using salt as a plasticizer. This is a Green Chemistry approach, as PECs generate structures that are stabilized solely by reversible electrostatic interactions, avoiding the use of harmful crosslinkers completely. Furthermore, natural polyelectrolytes - chitosan and alginate - were used. Upon mixing them, membranes were obtained by drying the PECs at 37ºC, yielding compact PECs without resorting to organicsolvents. The plasticizing effect of salt after synthesis was shown by measuring tensile mechanical properties, which were lower when samples were immersed in high ionic strength solutions.Salt was also used during membrane synthesis in different quan- tities (0 M, 0.15 M and 0.5 M in NaCl) yielding structures with no significant differences in morphology and degradation (around 15% after 3 months in lysozyme). However, swelling was higher (about 10x) when synthesized in the presence of salt. In vitro cell studies using L929 fibroblasts showed that cells adhered and proliferated preferentially in membranes fabricated in the presence of salt (i.e. the membranes with lower tensile strength). Structures with physical-chemical properties controlled with precision open a path to tissue engineering strategies depending on fine tuning mechanical properties and cellular adhesion simply by changing ionic strength during membrane manufacture
Resumo:
The regeneration of soft biological tissues requires new substitutes that exhibit mechanical properties similar to the native tissue. Herein, thin saloplastic membranes with tunable physical properties are prepared by complexation of chitosan and alginate solutions containing different concentrations of sodium chloride. Polyelectrolyte complexes (PECs) are transferred to flat Petri dishes for compaction into membrane shapes by sedimentation and solvent evaporation. All membranes are resistant to degradation by lysozyme and are stable in solutions with pH values between 1 and 13. Immersing the different membranes in new doping solutions of increasing salt concentrations triggers the typical saloplastic behavior, with a high water absorption and decrease of the rigidity and ultimate tensile strength. The range of such variations is tuned by the sodium chloride amount used in the synthesis: high salt concentrations increase water uptake and tensile moduli, while decreasing the ultimate strength. Cellular assays demonstrate high proliferation rates and viability of L929 fibroblasts seeded onto the most rigid membranes. The results validate the use of saloplastic membranes as soft tissue substitutes for future biomedical applications.
Resumo:
Poly(vinylidene fluoride-co-chlorotrifluoroethylene) – P(VDF-CTFE) membranes are increasingly interesting for a wide range of applications, including battery separators, filtration membranes and biomedical applications. This work reports on the morphology, hydrophobicity, thermal and mechanical properties variation of P(VDF-CTFE) membranes processed by nonsolvent induced phase separation technique (NIPS) as a function of the main processing parameters. All membranes show a porous structure composed of large spherulites, (interconnected) micropores and/or microvoids depending on the processing conditions used that in turn affect their hydrophobicity and mechanical properties. The degree of crystallinity of the membranes remains approximately constant with a value of about 15 %, except for the membranes immediately immersed in ethanol, which is of about 23 %. In turn, the crystalline phases present in the copolymer is mainly affected by the temperature and nonsolvent characteristics of the coagulation bath, the β-phase content ranging from 33 to 100 %, depending on those processing parameters. It was show that the temperature of water-based coagulation bath plays an important role in order to produce structurally uniform and homogeneous porous membranes, which is particularly important from the point of view of technological applications.