968 resultados para Photographic criticism
Resumo:
Research on outcomes from psychiatric disorders has highlighted the importance of expressed emotion (EE), but its cost-effective measurement remains a challenge. This article describes development of the Family Attitude Scale (FAS), a 30-item instrument that can be completed by any informant. Its psychometric characteristics are reported in parents of undergraduate students and in 70 families with a schizophrenic member. The total FAS had high internal consistency in all samples, and reports of angry behaviour in FAS items showed acceptable inter-rater agreement. The FAS was associated with the reported anger, anger expression and anxiety of respondents. Substantial associations between the parents' FAS and the anger and anger expression of students was also observed. Parents of schizophrenic patients had higher FAS scores than parents of students, and the FAS was higher if disorder duration was longer or patient functioning was poorer. Hostility, high criticism and low warmth on the Camberwell Family Interview (CFI) were associated with a more negative FAS. The highest FAS in the family was a good predictor of a highly critical environment on the CFI. The FAS is a reliable and valid indicator of relationship stress and expressed anger that has wide applicability. (C) 1997 Elsevier Science Ireland Ltd.
Resumo:
Background: The aim of the study was to investigate how perfectionism and sensory phenomena (SP) interact as possible phenotypic components of obsessive-compulsive disorder (OCD). Methods: Forty-seven adult outpatients, meeting Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, criteria for OCD, and a control group of 41 community subjects were assessed using the Frost Multidimensional Perfectionism Scale (FM PS), the University of Sao Paulo-Sensory Phenomena Scale, and other standard measures of OCD severity. Results: Three of the FMPS subscales (""concern over mistakes,"" ""doubts about action,"" and ""parental criticism"") were significantly different between OCD patients and control subjects. All subtypes of SP were significantly more frequent and more severe in OCD than in control subjects. The ""incompleteness"" subtype of SP was associated with high scores on all dimensions of the FMPS, whereas the ""just-right"" subtype of SP was only associated with ""doubts about action,"" ""personal standards,"" and ""organization"" subscales of the FMPS. Conclusions: Presence and severity of SP and specific elements of perfectionism clearly distinguish OCD patients from healthy control subjects. Some SP subtypes are associated with specific FPMS subscale scores, whereas others are not. These results emphasize the relevance of assessing different subtypes of perfectionism and SP in OCD patients as important subcomponents of the OCD phenotype. (C) 2009 Elsevier Inc. All rights reserved.
Resumo:
Objective: The purpose of this study was to investigate the reliability and validity of photogrammetry in measuring the lateral spinal inclination angles. Methods: Forty subjects (32 female and 8 males) with a mean age of 23.4 +/- 11.2 years had their scoliosis evaluated by radiographs of their trunk, determined by the Cobb angle method, and by photogrammetry. The statistical methods used included Cronbach alpha, Pearson/Spearman correlation coefficients, and regression analyses. Results: The Cronbach a values showed that the photogrammetric measures showed high internal consistency, which indicated that the sample was bias free. The radiograph method showed to be more precise with intrarater reliabilities of 0.936, 0.975, and 0.945 for the thoracic, lumbar, and thoracolumbar curves, respectively, and interrater reliabilities of 0.942 and 0.879 for the angular measures of the thoracic and thoracolumbar segments, respectively. The regression analyses revealed a high determination coefficient although limited to the adjusted linear model between the radiographic and photographic measures. It was found that with more severe scoliosis, the lateral curve measures obtained with the photogrammetry were for the thoracic and lumbar regions (R = 0.619 and 0.551). Conclusions: The photogrammetric measures were found to be reproducible in this study and could be used as Supplementary information to decrease the number of radiographs necessary for the monitoring of scoliosis. (J Manipulative Physiol Ther 2009;32:423-430)
Resumo:
In adolescent idiopathic scoliosis (AIS) there has been a shift towards increasing the number of implants and pedicle screws, which has not been proven to improve cosmetic correction. To evaluate if increasing cost of instrumentation correlates with cosmetic correction using clinical photographs. 58 Lenke 1A and B cases from a multicenter AIS database with at least 3 months follow-up of clinical photographs were used for analysis. Cosmetic parameters on PA and forward bending photographs included angular measurements of trunk shift, shoulder balance, rib hump, and ratio measurements of waist line asymmetry. Pre-op and follow-up X-rays were measured for coronal and sagittal deformity parameters. Cost density was calculated by dividing the total cost of instrumentation by the number of vertebrae being fused. Linear regression and spearman`s correlation were used to correlate cost density to X-ray and photo outcomes. Three independent observers verified radiographic and cosmetic parameters for inter/interobserver variability analysis. Average pre-op Cobb angle and instrumented correction were 54A degrees (SD 12.5) and 59% (SD 25) respectively. The average number of vertebrae fused was 10 (SD 1.9). The total cost of spinal instrumentation ranged from $6,769 to $21,274 (Mean $12,662, SD $3,858). There was a weak positive and statistically significant correlation between Cobb angle correction and cost density (r = 0.33, p = 0.01), and no correlation between Cobb angle correction of the uninstrumented lumbar spine and cost density (r = 0.15, p = 0.26). There was no significant correlation between all sagittal X-ray measurements or any of the photo parameters and cost density. There was good to excellent inter/intraobserver variability of all photographic parameters based on the intraclass correlation coefficient (ICC 0.74-0.98). Our method used to measure cosmesis had good to excellent inter/intraobserver variability, and may be an effective tool to objectively assess cosmesis from photographs. Since increasing cost density only improves mildly the Cobb angle correction of the main thoracic curve and not the correction of the uninstrumented spine or any of the cosmetic parameters, one should consider the cost of increasing implant density in Lenke 1A and B curves. In the area of rationalization of health care expenses, this study demonstrates that increasing the number of implants does not improve any relevant cosmetic or radiographic outcomes.
Resumo:
The mechanical alterations related to the excessive use of accessory respiratory muscles and the mouth breathing observed in children with asthma may lead to the development of alterations in head posture, shoulders, thoracic region and, consequently, in alterations of body posture. The purpose of this study was to assess body posture changes of children with asthma compared to a non-asthmatic control group matched for gender, age, weight, and height. Thirty children with asthma and 30 non-asthmatic children aged 7 to 12 years were enrolled in this study. Digital photographic records were obtained for analysis of the body posture of the children by computed photogrammetry. The intraclass correlation coefficient and Student`s t test (p < 0.05) were used for statistical analysis. There were no significant differences between groups for the angles analyzed, except for the knee flexor angle. These results demonstrate that children with asthma did not present postural alterations compared to non-asthmatic controls since the only angle for which there was a significant difference between groups showed weak reproducibility. The findings of this study do not support the notion that children with asthma present alterations in body posture.
Resumo:
Purpose To determine the relationship between ocular hypertension and glaucoma in patients with Graves` orbitopathy. Methods A total of 107 patients with a diagnosis of Graves` orbitopathy, followed at the Oculoplasty sector of the University Hospital, Medical School of Ribeirao Preto, were evaluated by applanation tonometry, computed visual campimetry (Humphrey 30-2, Full Threshold) and analysis and photographic documentation of the optic nerve. The patients considered to have the suspicion of glaucoma were re-evaluated 1 year later for diagnostic confirmation or exclusion. Results A 3.74% prevalence of ocular hypertension (four patients) and a 2.8% prevalence of glaucoma (three patients) was observed. When considering only patients older than 40 years, the prevalence of ocular hypertension was 5.4% (four patients) and the prevalence of glaucoma was 4.76% (three patients). Conclusion The present study did not reveal a statistically significant difference in the prevalence of ocular hypertension or glaucoma between patients with Graves` orbitopathy and the general population.
Resumo:
Objective: The aim of this study was to evaluate the performances of observers in diagnosing proximal caries in digital images obtained from digital bitewing radiographs using two scanners and four digital cameras in Joint Photographic Experts Group (JPEG) and tagged image file format (TIFF) files, and comparing them with the original conventional radiographs. Method: In total, 56 extracted teeth were radiographed with Kodak Insight film (Eastman Kodak, Rochester, NY) in a Kaycor Yoshida X-ray device (Kaycor X-707;Yoshida Dental Manufacturing Co., Tokyo, Japan) operating at 70 kV and 7 mA with an exposure time of 0.40 s. The radiographs were obtained and scanned by CanonScan D646U (Canon USA Inc., Newport News, VA) and Genius ColorPage HR7X (KYE Systems Corp. America, Doral, FL) scanners, and by Canon Powershot G2 (Canon USA Inc.), Canon RebelXT (Canon USA Inc.), Nikon Coolpix 8700 (Nikon Inc., Melville, NY), and Nikon D70s (Nikon Inc.) digital cameras in JPEG and TIFF formats. Three observers evaluated the images. The teeth were then observed under the microscope in polarized light for the verification of the presence and depth of the carious lesions. Results: The probability of no diagnosis ranged from 1.34% (Insight film) to 52.83% (CanonScan/JPEG). The sensitivity ranged from 0.24 (Canon RebelXT/JPEG) to 0.53 (Insight film), the specificity ranged from 0.93 (Nikon Coolpix/JPEG, Canon Powershot/TIFF, Canon RebelXT/JPEG and TIFF) to 0.97 (CanonScan/TIFF and JPEG) and the accuracy ranged from 0.82 (Canon RebelXT/JPEG) to 0.91 (CanonScan/JPEG). Conclusion: The carious lesion diagnosis did not change in either of the file formats (JPEG and TIFF) in which the images were saved for any of the equipment used. Only the CanonScan scanner did not have adequate performance in radiography digitalization for caries diagnosis and it is not recommended for this purpose. Dentomaxillofacial Radiology (2011) 40, 338-343. doi: 10.1259/dmfr/67185962
Resumo:
An assessment of the bi-directional reflectance distribution function (BRDF) of corals with different morphologies was undertaken using hyperspectral reflectance measurements. The highest variance in reflectance obtained at different viewing angles was found for the open branching Acropora colony, possibly attributed to branch orientation and internal shadow distribution. Spectral separation within and between features at the nominated sensor-viewing angles was greatest in the near infrared portion of the spectrum. The analysis of coral reef bi-directional reflectance properties and degree of internal shadowing holds potential for future assessment and information extraction relating to coral structural characteristics.
Resumo:
Land related information about the Earth's surface is commonIJ found in two forms: (1) map infornlation and (2) satellite image da ta. Satellite imagery provides a good visual picture of what is on the ground but complex image processing is required to interpret features in an image scene. Increasingly, methods are being sought to integrate the knowledge embodied in mop information into the interpretation task, or, alternatively, to bypass interpretation and perform biophysical modeling directly on derived data sources. A cartographic modeling language, as a generic map analysis package, is suggested as a means to integrate geographical knowledge and imagery in a process-oriented view of the Earth. Specialized cartographic models may be developed by users, which incorporate mapping information in performing land classification. In addition, a cartographic modeling language may be enhanced with operators suited to processing remotely sensed imagery. We demonstrate the usefulness of a cartographic modeling language for pre-processing satellite imagery, and define two nerv cartographic operators that evaluate image neighborhoods as post-processing operations to interpret thematic map values. The language and operators are demonstrated with an example image classification task.