991 resultados para PRESSURE-DROP


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cu2ZnSnSe4 (CZTSe) is a p-type semiconductor with a high absorption coefficient, 104 to 105 cm-1, and is being seen as a possible replacement for Cu(In,Ga)Se2 in thin film solar cells. Yet, there are some fundamental properties of CZTSe that are not well known, one of them is its band gap. In order to resolve its correct value it is necessary to improve the growth conditions to ensure that single phase crystalline thin films are obtained. One of the problems encountered when growing CZTSe is the loss of Sn through evaporation of SnSe. Stoichiometric films are then difficult to obtain and usually there are other phases present. One possible way to overcome this problem is to increase the pressure of growth of CZTSe. This can be done by introducing an atmosphere of an inert gas like Ar or N2. In this work we report the results of morphological, structural and optical studies of the properties of CZTSe thin films grown by selenization of DC magnetron sputtered metallic layers under different Ar pressures. The films are analysed by SEM/EDS, Raman scattering and XRD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study compared the ground reaction forces (GRF) and plantar pressures between unloaded and occasional loaded gait. The GRF and plantar pressures of 60 participants were recorded during unloaded gait and occasional loaded gait (wearing a backpack that raised their body mass index to 30); this load criterion was adopted because is considered potentially harmful in permanent loaded gait (obese people). The results indicate an overall increase (absolute values) of GRF and plantar pressures during occasional loaded gait (p < 0.05); also, higher normalized (by total weight) values in the medial midfoot and toes, and lower values in the lateral rearfoot region were observed. During loaded gait the magnitude of the vertical GRF (impact and thrust maximum) decreased and the shear forces increased more than did the proportion of the load (normalized values). These data suggest a different pattern of GRF and plantar pressure distribution during occasional loaded compared to unloaded gait.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

^len^lpt^aOBJETIVO: Descrever a prevalência de pressão arterial limítrofe (PAL) e hipertensão (HT) entre adultos jovens e avaliar a associação entre tamanho ao nascer e PAL/HT. MÉTODOS: Dados foram coletados do primeiro estudo brasileiro de coorte de nascimentos em Ribeirão Preto (sudeste do Brasil), iniciado em 1978/79. De 6.827 recém-nascidos de parto único hospitalar, 2.060 foram avaliados aos 23/25 anos. Foram realizadas coleta de sangue, avaliação antropométrica e obtidas informações sobre ocupação, escolaridade, hábitos de vida e doenças crônicas. Pressão arterial (PA) foi classificada em: 1) PAL: PA sistólica (PAS) ≥ 130 e < 140 mm Hg e/ou PA diastólica (PAD) ≥ 85 e < 90 mmHg; 2) HT: PAS ≥ 140 e/ou PAD ≥ 90 mm Hg. Foi aplicado modelo de regressão logística politômica. RESULTADOS: A prevalência de PAL foi de 13,5% (homens 23,2%) e a de HT, 9,5% (homens 17,7%). PAL foi independentemente associada com sexo masculino (RR 8,84; IC95%: 6,09;12,82), comprimento ao nascer ≥ 50 cm (RR 1,97; 1,04; 3,73), índice de massa corporal (IMC) ≥ 30 kg/m² (RR 3,23; 2,02; 5,15) e circunferência de cintura alterada (RR 1,61; 1,13;2,29), enquanto HT associou-se com sexo masculino (RR 15,18; 8,92;25,81), IMC ≥ 30 kg/m² (RR 3,68; 2,23;6,06), circunferência de cintura alterada (RR 2,68; 1,77;4,05) e glicemia elevada (RR 2,55; 1,27;5,10), mas não com comprimento ao nascer. CONCLUSÕES: As prevalências de PAL e HT entre os adultos jovens dessa coorte foram maiores em homens que em mulheres. Maior comprimento ao nascer foi associado com PAL, mas não com HT, enquanto peso ao nascer não foi associado com PAL ou HT. Fatores de risco do adulto explicaram a maioria dos aumentos de PAL ou HT.^les^aOBJETIVO: Describir la prevalencia de presión arterial limítrofe (PAL) e hipertensión (HT) entre adultos jóvenes y evaluar la asociación entre tamaño al nacer y PAL/HT. MÉTODOS: : Los datos fueron colectados en el primer estudio de cohorte de nacimientos brasileño en Ribeirao Preto (sureste de Brasil), iniciado en 1978/79. De 6.827 recién nacidos de parto único hospitalario, 2.060 fueron evaluados a los 23/25 años. Se realizaron colecta de sangre, evaluación antropométrica y obtenidas informaciones sobre ocupación, escolaridad, hábitos de vida y enfermedades crónicas. Presión arterial (PA) fue clasificada en: 1) PAL: PA sistólica (PAS) ≥ 130 y < 140 mm Hg y/o PA diastólica (PAD) ≥ 85 y < 90 mm Hg; 2) HT: PAS ≥ 140 y/o PAD ≥ 90 mm Hg. Se aplicó modelo de regresión logística politómica. RESULTADOS: La prevalencia de PAL fue de 13,5% (hombres 23,2%) y la de HT, 9,5% (hombres 17,7%). PAL fue independientemente asociada con sexo masculino (Riesgo Relativo - RR) 8,84; 95%IC: 6,09;12,82), estatura al nacer ≥ 50 cm (RR 1,97; 1,04; 3,73), índice de masa corporal (IMC) ≥ 30 kg/m2 (RR 3,23; 2,02; 5,15) y circunferencia de cintura alterada (RR 1,61; 1,13;2,29), mientras el HT se asoció con sexo masculino (RR 15,18; 8,92;25,81), IMC ≥ 30 kg/m2 (RR 3,68; 2,23;6,06), circunferencia de cintura alterada (RR 2,68; 1,77;4,05) y glicemia elevada (RR 2,55; 1,27;5,10), pero no con estatura al nacer. CONCLUSIONES: Las prevalencias de PAL y HT entre los adultos jóvenes de la cohorte fueron mayores en hombres que en mujeres. Mayor estatura al nacer fue asociado con PAL, pero no con HT, mientras que el peso al nacer no estuvo asociado con PAL o HT. Factores de riesgo de adulto explicaron la mayoría de los aumentos de PAL o HT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports on the analysis of tidal breathing patterns measured during noninvasive forced oscillation lung function tests in six individual groups. The three adult groups were healthy, with prediagnosed chronic obstructive pulmonary disease, and with prediagnosed kyphoscoliosis, respectively. The three children groups were healthy, with prediagnosed asthma, and with prediagnosed cystic fibrosis, respectively. The analysis is applied to the pressure–volume curves and the pseudophaseplane loop by means of the box-counting method, which gives a measure of the area within each loop. The objective was to verify if there exists a link between the area of the loops, power-law patterns, and alterations in the respiratory structure with disease. We obtained statistically significant variations between the data sets corresponding to the six groups of patients, showing also the existence of power-law patterns. Our findings support the idea that the respiratory system changes with disease in terms of airway geometry and tissue parameters, leading, in turn, to variations in the fractal dimension of the respiratory tree and its dynamics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we demonstrate an add/drop filter based on SiC technology. Tailoring of the channel bandwidth and wavelength is experimentally demonstrated. The concept is extended to implement a 1 by 4 wavelength division multiplexer with channel separation in the visible range. The device consists of a p-i'(a-SiC:H)-n/p-i(a-Si: H)-n heterostructure. Several monochromatic pulsed lights, separately or in a polychromatic mixture illuminated the device. Independent tuning of each channel is performed by steady state violet bias superimposed either from the front and back sides. Results show that, front background enhances the light-to-dark sensitivity of the long and medium wavelength channels and quench strongly the others. Back violet background has the opposite behaviour. This nonlinearity provides the possibility for selective removal or addition of wavelengths. An optoelectronic model is presented and explains the light filtering properties of the add/drop filter, under different optical bias conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This contribution presents novel concepts for analysis of pressure–volume curves, which offer information about the time domain dynamics of the respiratory system. The aim is to verify whether a mapping of the respiratory diseases can be obtained, allowing analysis of (dis)similarities between the dynamical pattern in the breathing in children. The groups investigated here are children, diagnosed as healthy, asthmatic, and cystic fibrosis. The pressure–volume curves have been measured by means of the noninvasive forced oscillation technique during breathing at rest. The geometrical fractal dimension is extracted from the pressure–volume curves and a power-law behavior is observed in the data. The power-law model coefficients are identified from the three sets and the results show that significant differences are present between the groups. This conclusion supports the idea that the respiratory system changes with disease in terms of airway geometry, tissue parameters, leading in turn to variations in the fractal dimension of the respiratory tree and its dynamics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Pressure ulcers are a high cost, high volume issue for health and medical care providers, having a detrimental effect on patients and relatives. Pressure ulcer prevention is widely covered in the literature, but little has been published regarding the risk to patients in the radiographical setting. This review of the current literature is to identify findings relevant to radiographical context. Methods: Literature searching was performed using Science Direct and Medline databases. The search was limited to articles published in the last ten years to remain current and excluded studies containing participants less than 17 years of age. In total 14 studies were acquired; three were excluded as they were not relevant. The remaining 11 studies were compared and reviewed. Discussion: Eight of the studies used ‘healthy’ participants and three used symptomatic participants. Nine studies explored interface pressure with a range of pressure mat technologies, two studies measured shear (MRI finite element modelling, and a non-invasive instrument), and one looked at blood flow and haemoglobin oxygenation. A range of surfaces were considered from trauma, nursing and surgical backgrounds for their ability to reduce pressure including standard mattresses, high specification mattresses, rigid and soft layer spine boards, various overlays (gel, air filled, foam). Conclusion: The current literature is not appropriate for the radiographic patient and cannot be extrapolated to a radiologic context. Sufficient evidence is presented in this review to support the need for further work specific to radiography in order to minimise the development of PU in at risk patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Pressure ulcers are a high cost, high volume issue for health and medical care providers, affecting patients’ recovery and psychological wellbeing. The current research of support surfaces on pressure as a risk factor in the development of pressure ulcers is not relevant to the specialised, controlled environment of the radiological setting. Method: 38 healthy participants aged 19-51 were placed supine on two different imaging surfaces. The XSENSOR pressure mapping system was used to measure the interface pressure. Data was acquired over a time of 20 minutes preceded by 6 minutes settling time to reduce measurement error. Qualitative information regarding participants’ opinion on pain and comfort was recorded using a questionnaire. Data analysis was performed using SPSS 22. Results: Data was collected from 30 participants aged 19 to 51 (mean 25.77, SD 7.72), BMI from 18.7 to 33.6 (mean 24.12, SD 3.29), for two surfaces, following eight participant exclusions due to technical faults. Total average pressure, average pressure for jeopardy areas (head, sacrum & heels) and peak pressure for jeopardy areas were calculated as interface pressure in mmHg. Qualitative data showed that a significant difference in experiences of comfort and pain was found in the jeopardy areas (P<0.05) between the two surfaces. Conclusion: A significant difference is seen in average pressure between the two surfaces. Pain and comfort data also show a significant difference between the surfaces, both findings support the proposal for further investigation into the effects of radiological surfaces as a risk factor for the formation of pressure ulcers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper studies the effect of ship speed and water depth on the propagation of ship generated waves. The ship is represented by a moving pressure distribution function at the free surface that is able to reproduce most of the phenomena involved in wave propagation. Results are obtained for a ship sailing along a coastal stretch made of a sloping bottom and a constant depth region. The results show that in the sloping bottom the crests of waves are bent along the slope and in the constant depth the standard Kelvin wave patterns can be found for the subcritical regime. In the critical regime the wave system is characterized by significant diverging waves and for a supercritical regime, the transverse waves disappear. © 2015 Taylor & Francis Group, London.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O uso da tecnologia tem crescido nas últimas décadas nas mais diversas áreas, seja na indústria ou no dia-a-dia, e é cada vez mais evidente os benefícios que traz. No desporto não é diferente. Cada dia surgem novos desenvolvimentos objetivando a melhoria do desempenho dos praticantes de atividades físicas, possibilitando atingir resultados nunca antes pensados. Além disto, a utilização da tecnologia no desporto permite a obtenção de dados biomecânicos que podem ser utilizados tanto no treinamento quando na melhoria da qualidade de vida dos atletas auxiliando na prevenção de lesões, por exemplo. Deste modo, o presente projeto se aplica na área do desporto, nomeadamente, na modalidade do surfe, onde a ausência de trabalhos científicos ainda é elevada, aliando a tecnologia eletrônica ao desporto para quantificar informações até então desconhecidas. Três fatores básicos de desempenho foram levantados, sendo eles: equilíbrio, posicionamento dos pés e movimentação da prancha de surfe. Estes fatores levaram ao desenvolvimento de um sistema capaz de medi-los dinamicamente através da medição das forças plantares e da rotação da prancha de surfe. Além da medição dos fatores, o sistema é capaz de armazenar os dados adquiridos localmente através de um cartão de memória, para posterior análise; e também enviá-los através de uma comunicação sem fio, permitindo a visualização do centro de pressões plantares; dos ângulos de rotação da prancha de surfe; e da ativação dos sensores; em tempo real. O dispositivo consiste em um sistema eletrônico embarcado composto por um microcontrolador ATMEGA1280; um circuito de aquisição e condicionamento de sinal analógico; uma central inercial; um módulo de comunicação sem fio RN131; e um conjunto de sensores de força Flexiforce. O firmware embarcado foi desenvolvido em linguagem C. O software Matlab foi utilizado para receção de dados e visualização em tempo real. Os testes realizados demostraram que o funcionamento do sistema atende aos requisitos propostos, fornecendo informação acerca do equilíbrio, através do centro de pressões; do posicionamento dos pés, através da distribuição das pressões plantares; e do movimento da prancha nos eixos pitch e roll, através da central inercial. O erro médio de medição de força verificado foi de -0.0012 ± 0.0064 N, enquanto a mínima distância alcançada na transmissão sem fios foi de 100 m. A potência medida do sistema foi de 330 mW.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: A single bout of aerobic exercise acutely decreases blood pressure, even in older adults with hypertension. Nonetheless, blood pressure responses to aerobic exercise in very old adults with hypertension have not yet been documented. Therefore, this study aimed to assess the effect of a single session of aerobic exercise on postexercise blood pressure in very old adults with hypertension. METHODS: Eighteen older adults with essential hypertension were randomized into exercise (N = 9, age: 83.4 ± 3.2 years old) or control (N = 9, age: 82.7 ± 2.5 years old) groups. The exercise group performed a session of aerobic exercise constituting 2 periods of 10 minutes of walking at an intensity of 40% to 60% of the heart rate reserve. The control group rested for the same period of time. Anthropometric variables and medication status were evaluated at baseline. Heart rate and systolic and diastolic blood pressures were measured at baseline, after exercise, and at 20 and 40 minutes postexercise. RESULTS: Systolic blood pressure showed a significant interaction for group × time (F3,24 = 6.698; P = .002; ηp = 0.153). In the exercise group, the systolic blood pressure at 20 (127.3 ± 20.9 mm Hg) and 40 minutes (123.7 ± 21.0 mm Hg) postexercise was significantly lower in comparison with baseline (135.6 ± 20.6 mm Hg). Diastolic blood pressure did not change. Heart rate was significantly higher after the exercise session. In the control group, no significant differences were observed. CONCLUSIONS: A single session of aerobic exercise acutely reduces blood pressure in very old adults with hypertension and may be considered an important nonpharmacological strategy to control hypertension in this age group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: 1. Identify differences in optic nerve sheath diameter (ONSD) as an indirect measure of intracranial pressure (ICP) in glaucoma patients and a healthy population. 2. Identify variables that may correlate with ONSD in primary open-angle glaucoma (POAG) and normal tension glaucoma (NTG) patients. METHODS: Patients with NTG (n = 46) and POAG (n = 61), and healthy controls (n = 42) underwent B-scan ultrasound measurement of ONSD by an observer masked to the patient diagnosis. Intraocular pressure (IOP) was measured in all groups, with additional central corneal thickness (CCT) and visual field defect measurements in glaucomatous patients. Only one eye per patient was selected. Kruskal-Wallis or Mann-Whitney were used to compare the different variables between the diagnostic groups. Spearman correlations were used to explore relationships among these variables. RESULTS: ONSD was not significantly different between healthy, NTG and POAG patients (6.09 ± 0.78, 6.03 ± 0.69, and 5.71 ± 0.83 respectively; p = 0.08). Visual field damage and CCT were not correlated with ONSD in either of the glaucoma groups (POAG, p = 0.31 and 0.44; NTG, p = 0.48 and 0.90 respectively). However, ONSD did correlate with IOP in NTG patients (r = 0.53, p < 0.001), while it did not in POAG patients and healthy controls (p = 0.86, p = 0.46 respectively). Patient's age did not relate to ONSD in any of the groups (p > 0.25 in all groups). CONCLUSIONS: Indirect measurements of ICP by ultrasound assessment of the ONSD may provide further insights into the retrolaminar pressure component in glaucoma. The correlation of ONSD with IOP solely in NTG patients suggests that the translaminar pressure gradient may be of particular importance in this type of glaucoma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To examine the combined effects of physical activity and weight status on blood pressure (BP) in preschool-aged children. Study design The sample included 733 preschool-aged children (49% female). Physical activity was objectively assessed on 7 consecutive days by accelerometry. Children were categorized as sufficiently active if they met the recommendation of at least 60 minutes daily of moderate-to-vigorous physical activity (MVPA). Body mass index was used to categorize children as nonoverweight or overweight/obese, according to the International Obesity Task Force benchmarks. BP was measured using an automated BP monitor and categorized as elevated or normal using BP percentile-based cut-points for age, sex, and height. Results The prevalence of elevated systolic BP (SBP) and diastolic BP was 7.7% and 3.0%, respectively. The prevalence of overweight/obese was 32%, and about 15% of children did not accomplish the recommended 60 minutes of daily MVPA. After controlling for age and sex, overweight/obese children who did not meet the daily MVPA recommendation were 3 times more likely (OR 3.8; CI 1.6-8.6) to have elevated SBP than nonoverweight children who met the daily MVPA recommendation. Conclusions Overweight or obese preschool-aged children with insufficient levels of MVPA are at significantly greater risk for elevated SBP than their non overweight and sufficiently active counterparts. (J Pediatr 2015;167:98-102).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The aim of the this study was to determine the effect of intravitreal antivascular endothelial growth factor injections on intraocular pressure (IOP) and identify possible risk factors for the development of increased IOP. MATERIALS AND METHODS: This prospective study included a total of 106 eyes receiving intravitreal injection of bevacizumab as treatment for macular edema or active choroidal neovascularization. IOP was measured by Goldmann applanation tonometry immediately before the intravitreal injection and 5 min, 1 h and 15 days after the procedure. The records of the study patients were reviewed for age, gender, history of glaucoma, diabetes mellitus, phakic status, systemic and topical medication and number of previous injections. Subconjunctival reflux was registered. IOP elevation was defined as IOP ≥21 mm Hg and/or a change from baseline of ≥5 mm Hg recorded at least on two or more measurements on the same visit. RESULTS: Mean preoperative IOP was 15.31 ± 3.90 mm Hg and postoperative IOP values were 27.27 ± 11.87 mm Hg (after 5 min), 17.59 ± 6.24 mm Hg (after 1 h) and 16.86 ± 3.62 mm Hg (after 15 days). The IOP variation was statistically significant between pre- and postoperative measurements (p < 0.05). Subconjunctival reflux was recorded in 11.3%, and in this subgroup the IOP at 5 min and at 1 h was lower than preoperative IOP (p < 0.05). CONCLUSIONS: More than one third of the eyes achieved IOPs >30 mm Hg 5 min after injection. Subconjunctival reflux contributed to a lower mean postoperative IOP (p < 0.05). Considerations for the management include prophylactic IOP lowering with medical therapy and/or preinjection ocular decompression for patients with a history of glaucoma or ocular hypertension and switching to an as-needed injection protocol in patients suffering a marked IOP rise in previous injections. © 2015 S. Karger AG, Basel.