985 resultados para Optical bias


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The arrangement of regulatory motifs in gene promoters, or promoterarchitecture, is the result of mutation and selection processes that have operated over manymillions of years. In mammals, tissue-specific transcriptional regulation is related to the presence ofspecific protein-interacting DNA motifs in gene promoters. However, little is known about therelative location and spacing of these motifs. To fill this gap, we have performed a systematic searchfor motifs that show significant bias at specific promoter locations in a large collection ofhousekeeping and tissue-specific genes.Results: We observe that promoters driving housekeeping gene expression are enriched inparticular motifs with strong positional bias, such as YY1, which are of little relevance in promotersdriving tissue-specific expression. We also identify a large number of motifs that show positionalbias in genes expressed in a highly tissue-specific manner. They include well-known tissue-specificmotifs, such as HNF1 and HNF4 motifs in liver, kidney and small intestine, or RFX motifs in testis,as well as many potentially novel regulatory motifs. Based on this analysis, we provide predictionsfor 559 tissue-specific motifs in mouse gene promoters.Conclusion: The study shows that motif positional bias is an important feature of mammalianproximal promoters and that it affects both general and tissue-specific motifs. Motif positionalconstraints define very distinct promoter architectures depending on breadth of expression andtype of tissue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a method to reconstruct 3D surfaces of silicon wafers from 2D images of printed circuits taken with a scanning electron microscope. Our reconstruction method combines the physical model of the optical acquisition system with prior knowledge about the shapes of the patterns in the circuit; the result is a shape-from-shading technique with a shape prior. The reconstruction of the surface is formulated as an optimization problem with an objective functional that combines a data-fidelity term on the microscopic image with two prior terms on the surface. The data term models the acquisition system through the irradiance equation characteristic of the microscope; the first prior is a smoothness penalty on the reconstructed surface, and the second prior constrains the shape of the surface to agree with the expected shape of the pattern in the circuit. In order to account for the variability of the manufacturing process, this second prior includes a deformation field that allows a nonlinear elastic deformation between the expected pattern and the reconstructed surface. As a result, the minimization problem has two unknowns, and the reconstruction method provides two outputs: 1) a reconstructed surface and 2) a deformation field. The reconstructed surface is derived from the shading observed in the image and the prior knowledge about the pattern in the circuit, while the deformation field produces a mapping between the expected shape and the reconstructed surface that provides a measure of deviation between the circuit design models and the real manufacturing process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We evaluate the performance of different optimization techniques developed in the context of optical flow computation with different variational models. In particular, based on truncated Newton methods (TN) that have been an effective approach for large-scale unconstrained optimization, we de- velop the use of efficient multilevel schemes for computing the optical flow. More precisely, we evaluate the performance of a standard unidirectional mul- tilevel algorithm - called multiresolution optimization (MR/OPT), to a bidrec- tional multilevel algorithm - called full multigrid optimization (FMG/OPT). The FMG/OPT algorithm treats the coarse grid correction as an optimiza- tion search direction and eventually scales it using a line search. Experimental results on different image sequences using four models of optical flow com- putation show that the FMG/OPT algorithm outperforms both the TN and MR/OPT algorithms in terms of the computational work and the quality of the optical flow estimation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lusters are composite thin layers of coinage metal nanoparticles in glass displaying peculiar optical properties and obtained by a process involving ionic exchange, diffusion, and crystallization. In particular, the origin of the high reflectance (golden-shine) shown by those layers has been subject of some discussion. It has been attributed to either the presence of larger particles, thinner multiple layers or higher volume fraction of nanoparticles. The object of this paper is to clarify this for which a set of laboratory designed lusters are analysed by Rutherford backscattering spectroscopy, transmission electron microscopy, x-ray diffraction, and ultraviolet-visible spectroscopy. Model calculations and numerical simulations using the finite difference time domain method were also performed to evaluate the optical properties. Finally, the correlation between synthesis conditions, nanostructure, and optical properties is obtained for these materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In Selten (1967) ?Strategy Method,? the second mover in the game submits a complete strategy. This basic idea has been exported to nonstrategic experiments, where a participant reports a complete list of contingent decisions, one for each situation or state in a given sequence, out of which one and only one state, randomly selected, will be implemented.In general, the method raises the following concern. If S0 and S1 are two differentsequences of states, and state s is in both S0 and S1, would the participant make the same decision in state s when confronted with S0 as when confronted with S1? If not, the experimental results are suspect of suffering from an ?embedding bias.?We check for embedding biases in elicitation methods of Charles Holt and Susan Laury(Laury and Holt, 2000, and Holt and Laury, 2002), and of the present authors (Bosch-Dom?nech and Silvestre, 1999, 2002, 2006a, b) by appropriately chosen replications of the original experiments. We find no evidence of embedding bias in our work. But in Holt and Laury?s method participants tend to switch earlier to the riskier option when later pairs of lotteries are eliminated from the sequence, suggesting the presence of some embedding bias.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The influence of external factors on food preferences and choices is poorly understood. Knowing which and how food-external cues impact the sensory processing and cognitive valuation of food would provide a strong benefit toward a more integrative understanding of food intake behavior and potential means of interfering with deviant eating patterns to avoid detrimental health consequences for individuals in the long run. We investigated whether written labels with positive and negative (as opposed to 'neutral') valence differentially modulate the spatio-temporal brain dynamics in response to the subsequent viewing of high- and low-energetic food images. Electrical neuroimaging analyses were applied to visual evoked potentials (VEPs) from 20 normal-weight participants. VEPs and source estimations in response to high- and low- energy foods were differentially affected by the valence of preceding word labels over the ~260-300 ms post-stimulus period. These effects were only observed when high-energy foods were preceded by labels with positive valence. Neural sources in occipital as well as posterior, frontal, insular and cingulate regions were down-regulated. These findings favor cognitive-affective influences especially on the visual responses to high-energetic food cues, potentially indicating decreases in cognitive control and goal-adaptive behavior. Inverse correlations between insular activity and effectiveness in food classification further indicate that this down-regulation directly impacts food-related behavior.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report magnetic and magneto-optical measurements of two Mn12 single-molecule magnet derivatives isolated in organic glasses. Field-dependent magnetic circular dichroism (MCD) intensity curves (hysteresis cycles) are found to be essentially identical to superconducting quantum interference device magnetization results and provide experimental evidence for the potential of the optical technique for magnetic characterization. Optical observation of magnetic tunneling has been achieved by studying the decay of the MCD signal at weak applied magnetic field

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Systematic reviews and meta-analyses of pre-clinical studies, in vivo animal experiments in particular, can influence clinical care. Publication bias is one of the major threats of validity in systematic reviews and meta-analyses. Previous empirical studies suggested that systematic reviews and meta-analyses have become more prevalent until 2010 and found evidence for compromised methodological rigor with a trend towards improvement. We aim to comprehensively summarize and update the evidence base on systematic reviews and meta-analyses of animal studies, their methodological quality and assessment of publication bias in particular. METHODS/DESIGN: The objectives of this systematic review are as follows: âeuro¢To investigate the epidemiology of published systematic reviews of animal studies until present. âeuro¢To examine methodological features of systematic reviews and meta-analyses of animal studies with special attention to the assessment of publication bias. âeuro¢To investigate the influence of systematic reviews of animal studies on clinical research by examining citations of the systematic reviews by clinical studies. Eligible studies for this systematic review constitute systematic reviews and meta-analyses that summarize in vivo animal experiments with the purpose of reviewing animal evidence to inform human health. We will exclude genome-wide association studies and animal experiments with the main purpose to learn more about fundamental biology, physical functioning or behavior. In addition to the inclusion of systematic reviews and meta-analyses identified by other empirical studies, we will systematically search Ovid Medline, Embase, ToxNet, and ScienceDirect from 2009 to January 2013 for further eligible studies without language restrictions. Two reviewers working independently will assess titles, abstracts, and full texts for eligibility and extract relevant data from included studies. Data reporting will involve a descriptive summary of meta-analyses and systematic reviews. DISCUSSION: Results are expected to be publicly available later in 2013 and may form the basis for recommendations to improve the quality of systematic reviews and meta-analyses of animal studies and their use with respect to clinical care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider the numerical treatment of the optical flow problem by evaluating the performance of the trust region method versus the line search method. To the best of our knowledge, the trust region method is studied here for the first time for variational optical flow computation. Four different optical flow models are used to test the performance of the proposed algorithm combining linear and nonlinear data terms with quadratic and TV regularization. We show that trust region often performs better than line search; especially in the presence of non-linearity and non-convexity in the model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The potential of digital holography for complex manipulation of micron-sized particles with optical tweezers has been clearly demonstrated. By contrast, its use in quantitative experiments has been rather limited, partly due to fluctuations introduced by the spatial light modulator (SLM) that displays the kinoforms. This is an important issue when high temporal or spatial stability is a concern. We have investigated the performance of both an analog-addressed and a digitally-addressed SLM, measuring the phase fluctuations of the modulated beam and evaluating the resulting positional stability of a holographic trap. We show that, despite imparting a more unstable modulation to the wavefront, our digitally-addressed SLM generates optical traps in the sample plane stable enough for most applications. We further show that traps produced by the analog-addressed SLM exhibit a superior pointing stability, better than 1 nm, which is comparable to that of non-holographic tweezers. These results suggest a means to implement precision force measurement experiments with holographic optical tweezers (HOTs).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Turning biases have been associated with unbalanced hemispheric dopaminergic activity, and this activity has been correlated with cue-directed behaviors. Moreover, a sexual differentiation in hippocampal dopaminergic receptors following learning has been shown. In humans, pointing responses towards the starting point is commonly used to assess the accuracy of direction estimation after locomotion. Thus, it may be of interest for the field of spatial cognition to explore human sex differences in spontaneous turning bias when a body rotation is required. To this end, male and female blindfolded subjects were guided in a linear displacement and asked to rotate in order to point in the direction of the starting position. The main finding was a massive difference between men and women. 80% of women showed a turning bias to the right when 69% of men showed a bias to the left. Moreover, these preferences were not correlated with handedness. These results suggest basic preferences associated to sex might influence male and female performance in spatial cognition. They also suggest experimental procedures may be biased in favor of male or female strategies. Therefore, such preferences should be considered in order to gain further insight into the development of more balanced procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ability of a population to adapt to changing environments depends critically on the amount and kind of genetic variability it possesses. Mutations are an important source of new genetic variability and may lead to new adaptations, especially if the population size is large. Mutation rates are extremely variable between and within species, and males usually have higher mutation rates as a result of elevated rates of male germ cell division. This male bias affects the overall mutation rate. We examined the factors that influence male mutation bias, and focused on the effects of classical life-history parameters, such as the average age at reproduction and elevated rates of sperm production in response to sexual selection and sperm competition. We argue that human-induced changes in age at reproduction or in sexual selection will affect male mutation biases and hence overall mutation rates. Depending on the effective population size, these changes are likely to influence the long-term persistence of a population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background : The issue of gender is acknowledged as a key issue for the AIDS epidemic. World AIDS Conferences (WAC) have constituted a major discursive space for the epidemic. We sought to establish the balance regarding gender in the AIDS scientific discourse by following its development in the published proceedings of WAC. Fifteen successive WAC 1989-2012 served to establish a "barometer" of scientific interest in heterosexual and homo/bisexual men and women throughout the epidemic. It was hypothesised that, as in other domains of Sexual and Reproductive Health, heterosexual men would be "forgotten" partners. Method : Abstracts from each conference were entered in electronic form into an Access database. Queries were created to generate five categories of interest and to monitor their annual frequency. All abstract titles including the term "men" or "women" were identified. Collections of synonyms were systematically and iteratively developed in order to classify further abstracts according to whether they included terms referring to "homo/bisexual" or "heterosexual". Reference to "Mother to Child Transmission" (MTCT) was also flagged. Results : The category including "men", but without additional reference to "homo-bisexuel" (i.e. referring to men in general and/or to heterosexual men) consistently appears four times less often than the equivalent category for women. Excluding abstracts on women and MTCT has little impact on this difference. Abstracts including reference to both "men" and "homo-bisexual" emerge as the secondmost frequent category; presence of the equivalent category for women is minimal. Conclusion : The hypothesised absence of heterosexual men in the AIDS discourse was confirmed. Although the relative presence of homo-bisexual men and women as a focal subject may be explained by epidemiological data, this is not so in the case of heterosexual men and women. This imbalance has consequences for HIV prevention.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A major problem with holographic optical tweezers (HOTs) is their incompatibility with laser-based position detection methods, such as back-focal-plane interferometry (BFPI). The alternatives generally used with HOTs, like high-speed video tracking, do not offer the same spatial and temporal bandwidths. This has limited the use of this technique in precise quantitative experiments. In this paper, we present an optical trap design that combines digital holography and back-focal-plane displacement detection. We show that, with a particularly simple setup, it is possible to generate a set of multiple holographic traps and an additional static non-holographic trap with orthogonal polarizations and that they can be, therefore, easily separated for measuring positions and forces with the high positional and temporal resolutions of laser-based detection. We prove that measurements from both polarizations contain less than 1% crosstalk and that traps in our setup are harmonic within the typical range. We further tested the instrument in a DNA stretching experiment and we discuss an interesting property of this configuration: the small drift of the differential signal between traps.