938 resultados para Objective function values


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The left ventricular response to dobutamine may be quantified using tissue Doppler measurement of myocardial velocity or displacement or 3-dimensional echocardiography to measure ventricular volume and ejection fraction. This study sought to explore the accuracy of these methods for predicting segmental and global responses to therapy. Standard dobutamine and 3-dimensional echocardiography were performed in 92 consecutive patients with abnormal left ventricular function at rest. Recovery of function was defined by comparison with follow-up echocardiography at rest 5 months later. Segments that showed improved regional function at follow-up showed a higher increment in peak tissue Doppler velocity with dobutamine therapy than in nonviable segments (1.2 +/- 0.4 vs 0.3 +/- 0.2 cm/s, p = 0.001). Similarly, patients who showed a > 5% improvement of ejection fraction at follow-up showed a greater displacement response to dobutamine (6.9 +/- 3.2 vs 2.1 +/- 2.3 mm, p = 0.001), as well as a higher rate of ejection fraction, response to dobutamine (9 +/- 3% vs 2 +/- 2%, p = 0.001). The optimal cutoff values for predicting subsequent recovery of function at rest were an increment of peak velocity > 1 cm/s, >5 mm of displacement, and a >5% improvement of ejection fraction with low-dose dobutamine. (C) 2003 by Excerpta Medica, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Translabial ultrasound is increasingly being used for the assessment of women presenting with pelvic floor dysfunction and incontinence (1,2). However, there is little information on normal values for bladder neck descent, with the two available studies disagreeing widely (3,4). No data has so far been published on mobility of the central and posterior compartment which can now also be assessed by ultrasound (5). This study presents normal values for urethral, bladder, cervical and rectal mobility in a cohort of young, stress continent, nulliparous nonpregnant women. Methods 118 nonpregnant nulliparous Caucasian women between 18 and 23 years of age were recruited for an ongoing twin study of pelvic floor function. Translabial ultrasound assessment of pelvic organ mobility was undertaken supine and after bladder emptying (6,7). The best of at least three effective Valsalva manoeuvres was used for evaluation, with no attempts at standardization of Valsalva pressure. Parameters of anterior compartment mobility were obtained by the use of on-screen calipers; cervical and rectal descent were evaluated on printouts. All examinations were carried out under direct supervision of the first author or by personnel trained by him for at least 100 consecutive assessments. Results The median age of participants in this study was 20 (range 18- 23). Mean body mass index was 23 (range 16.9- 36.7). Of 118 women, 2 were completely unable to perform a Valsalva manoeuvre despite repeated efforts at teaching and were excluded from analysis, as were ten women who complained of urinary stress incontinence, leaving 106 datasets. Average measurements for the parameters ‘retrovesical angle at rest’ (RVA-R) and on Valsalva (RVA-S), urethral rotation, bladder neck mobility, cysto-cele descent, cervical descent and descent of the rectal ampulla are given in Table 1.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introdução: A concentração da creatinina no plasma é usada para avaliar a função renal, mas a depuração da creatinina plasmática (DCP) constitui método mais sensível para essa finalidade. Objetivo: Correlacionar a DCP em coleta urinária de 12 horas noturna com a de 24 horas. Métodos: Noventa e cinco voluntários (34-64 anos) coletaram urina durante 24 horas em dois frascos: diurno (das 7h às 19h) e noturno (das 19h às 7h do dia seguinte). A coleta de sangue se deu em jejum para medidas bioquímicas. A correlação entre as variáveis foi feita pelo teste Pearson (r) e a concordância de medidas, pelo teste de Bland-Altman. Resultados: Urinas de quatro indivíduos foram recusadas por erro de coleta. Na amostra final (n = 91; 42 homens), havia 23 hipertensos e cinco diabéticos. A DCP (mL/min/1,73 m2) foi menor no período noturno em mulheres (77,8 ± 22,7 versus 88,4 ± 23,6; p < 0,05) e similar em homens (91,2 ± 22,9 versus 97,3 ± 30,9; p > 0,05). As correlações entre a DCP na urina de 12 horas noturna ou diurna e a de 24 horas foram fortes (r = 0,85 e 0,83, respectivamente). Em 85 e 83 dos 91 indivíduos, a medida da DCP noturna e diurna, respectivamente, foi concordante com a de 24 horas. Conclusão: A urina de 12 horas, sobretudo quando coletada à noite, fornece valores de DCP similares àqueles obtidos em coleta de 24 horas. Como essa coleta é mais fácil de ser feita em pacientes ambulatoriais à noite, esse período deveria ser preferido para a medida da filtração glomerular.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To establish reference values for hippuric acid (HA) excreted in the urine, and to evaluate the impact of age, gender, alcohol, and tobacco, on these levels in a population nonexposed to toluene. METHODS: Reference values for hippuric acid in urine were determined in 115 toluene nonexposed healthy volunteers, from Alfenas city, Southeastern Brazil. A questionnaire was applied to each volunteer and data on occupational and personal habits were collected. Biochemical and hematological analyses were used to confirm the volunteers' good health condition. Reference values were expressed in g HA/g urine creatinine, as mean ± standard deviation (x ± SD), median, 95% confidence interval (95%CI), 95th percentile, and upper reference value (URV, mean +2 SD). RESULTS: Reference values of hippuric acid in urine were: mean ± standard deviation =0.18±0.10; median =0.15; 95% confidence interval =0.16±0.20; 95th percentile = 0.36 and upper reference value (URV, mean +2 SD) =0.38. Statistically significant differences in urinary HA (Wilcoxon - Mann/Whitney, p<0.05) were observed for different genders and age groups. Alcohol ingestion and smoking habit did not significantly affect the results. CONCLUSIONS: The reference values of hippuric acid in urine can be used in biomonitoring programs of workers occupationally exposed to toluene, especially in the southern region of the state of Minas Gerais. Age and gender may affect the HA reference values.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work addresses the treatment by nanofiltration (NF) of solutions containing NaCN and NH(4)Cl at various pH values. The NF experiments are carried out in a Lab-Unit equipped with NF-270 membranes for model solutions that are surrogates of industrial ammoniacal wastewaters generated in the coke-making processes. The applied pressure is 30 bar. The main objective is the separation of the compounds NaCN and NH(4)Cl and the optimization of this separation as a function of the pH. Membrane performance is highly dependent on solution composition and characteristics, namely on the pH. In fact, the rejection coefficients for the binary model solution containing sodium cyanide are always higher than the rejections coefficients for the ammonium chloride model solution. For ternary solutions (cyanide/ammonium/water) it was observed that for pH values lower than 9 the rejection coefficients to ammonium are well above the ones observed for the cyanides, but for pH values higher than 9.5 there is a drastic decrease in the ammonium rejection coefficients with the increase of the pH. These results take into account the changes that occur in solution, namely, the solute species that are predominant, with the increase of the pH. The fluxes of the model solutions decreased with increased pH. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A crucial method for investigating patients with coronary artery disease (CAD) is the calculation of the left ventricular ejection fraction (LVEF). It is, consequently, imperative to precisely estimate the value of LVEF--a process that can be done with myocardial perfusion scintigraphy. Therefore, the present study aimed to establish and compare the estimation performance of the quantitative parameters of the reconstruction methods filtered backprojection (FBP) and ordered-subset expectation maximization (OSEM). Methods: A beating-heart phantom with known values of end-diastolic volume, end-systolic volume, and LVEF was used. Quantitative gated SPECT/quantitative perfusion SPECT software was used to obtain these quantitative parameters in a semiautomatic mode. The Butterworth filter was used in FBP, with the cutoff frequencies between 0.2 and 0.8 cycles per pixel combined with the orders of 5, 10, 15, and 20. Sixty-three reconstructions were performed using 2, 4, 6, 8, 10, 12, and 16 OSEM subsets, combined with several iterations: 2, 4, 6, 8, 10, 12, 16, 32, and 64. Results: With FBP, the values of end-diastolic, end-systolic, and the stroke volumes rise as the cutoff frequency increases, whereas the value of LVEF diminishes. This same pattern is verified with the OSEM reconstruction. However, with OSEM there is a more precise estimation of the quantitative parameters, especially with the combinations 2 iterations × 10 subsets and 2 iterations × 12 subsets. Conclusion: The OSEM reconstruction presents better estimations of the quantitative parameters than does FBP. This study recommends the use of 2 iterations with 10 or 12 subsets for OSEM and a cutoff frequency of 0.5 cycles per pixel with the orders 5, 10, or 15 for FBP as the best estimations for the left ventricular volumes and ejection fraction quantification in myocardial perfusion scintigraphy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To examine the effects of the length and timing of nighttime naps on performance and physiological functions, an experimental study was carried out under simulated night shift schedules. METHODS: Six students were recruited for this study that was composed of 5 experiments. Each experiment involved 3 consecutive days with one night shift (22:00-8:00) followed by daytime sleep and night sleep. The experiments had 5 conditions in which the length and timing of naps were manipulated: 0:00-1:00 (E60), 0:00-2:00 (E120), 4:00-5:00 (L60), 4:00-6:00 (L120), and no nap (No-nap). During the night shifts, participants underwent performance tests. A questionnaire on subjective fatigue and a critical flicker fusion frequency test were administered after the performance tests. Heart rate variability and rectal temperature were recorded continuously during the experiments. Polysomnography was also recorded during the nap. RESULTS: Sleep latency was shorter and sleep efficiency was higher in the nap in L60 and L120 than that in E60 and E120. Slow wave sleep in the naps in E120 and L120 was longer than that in E60 and L60. The mean reaction time in L60 became longer after the nap, and faster in E60 and E120. Earlier naps serve to counteract the decrement in performance and physiological functions during night shifts. Performance was somewhat improved by taking a 2-hour nap later in the shift, but deteriorated after a one-hour nap. CONCLUSIONS: Naps in the latter half of the night shift were superior to earlier naps in terms of sleep quality. However performance declined after a 1-hour nap taken later in the night shift due to sleep inertia. This study suggests that appropriate timing of a short nap must be carefully considered, such as a 60-min nap during the night shift.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introdução: Embora existam estratégias para coordenar as funções postural e ventilatória numa situação normal, isto pode não ser verdade quando a necessidade para uma das funções está aumentada, como por exemplo em patologia respiratória (asma) ou no exercício físico, em que subsistem maiores necessidades ventilatórias. O método Pilates, que foca a relação entre o corpo e a disciplina mental, visa prosperar a saúde e o bem-estar pelo enfatizar da boa postura, do alinhamento corporal e da coordenação da ventilação com o movimento. Objectivo: Comparar características de controlo motor e parâmetros ventilatórios em asmáticos controlados e indivíduos sem patologia, e verificar o efeito de um programa de exercícios segundo Pilates nesses outcomes em indivíduos com asma controlada. Métodos: Estudo quasi-experimental, com uma amostra constituída por 21 estudantes voluntários, 7 pertencentes ao “grupo sem patologia”, 7 ao “grupo controlo asmático” e 7 ao “grupo experimental asmático”. Para avaliação do timing de ativação e do padrão de recrutamento muscular no movimento rápido do membro superior foi utilizada eletromiografia de superfície do Diafragma, Eretor da Coluna, Multífidos, Oblíquo Externo, Reto Anterior e Transverso Abdominal/Oblíquo Interno. Foram também avaliados parâmetros de função ventilatória: a percentagem de volume expiratório forçado no primeiro segundo do previsto, o débito expiratório máximo instantâneo, a ventilação máxima voluntária, a pressão inspiratória máxima e a pressão expiratória máxima. As avaliações decorreram antes e após 8 semanas da aplicação de um programa de exercícios segundo Pilates no grupo experimental asmático, com exceção do grupo sem patologia que realizou apenas o primeiro momento de avaliação. Resultados: O grupo controlo asmático apresentou um timing de ativação significativamente maior do Transverso Abdominal/Oblíquo Interno e do Diafragma, em relação ao grupo sem patologia. Nos parâmetros ventilatórios, o grupo controlo asmático apresentou menores valores de percentagem de volume expiratório no primeiro segundo do previsto, de débito expiratório máximo instantâneo e de pressão expiratória máxima. Após a realização do programa de exercícios segundo Pilates verificaram-se alterações significativas no timing de activação do Eretor da Coluna, do Multífidos, do Transverso/Oblíquo Interno e do Diafragma, tendo ambos diminuído no grupo experimental asmático. Ainda, o grupo experimental asmático, em relação aos parâmetros ventilatórios, apresentou diferenças significativas no débito expiratório máximo instantâneo, na ventilação máxima voluntária e na pressão expiratória máxima, tendo ambos aumentado estes valores. Conclusão: Os asmáticos controlados parecem possuir características de controlo motor, especificamente no timing de ativação, e valores de parâmetros ventilatórios diferentes em comparação aos indivíduos sem patologia. O programa de exercícios segundo Pilates, implementado no grupo experimental asmático, parece ter influenciado positivamente esses outcomes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação de Mestrado em Gestão de Empresas/MBA

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As diferenças entre os géneros parecem surgir desde a origem da humanidade, quando a função do homem era caçar e da mulher fornecer cuidados às crianças e realizar trabalhos de cariz manual. O membro superior apresenta um papel primordial na execução da maioria das atividades relevantes para o ser humano, sendo pertinente a realização de avaliações mais objetivas do mesmo. Com a realização deste estudo pretendemos verificar se existem diferenças entre os géneros nos parâmetros eletromiográficos e cinemáticos do movimento durante uma atividade diária; perceber se os valores da eletromiografia e da cinemática do membro superior são dependentes do género à medida que a distância do objeto é alterada e ainda, levar a cabo a análise da atividade de beber. Para tal foram avaliados parâmetros de qualidade de movimento e parâmetros de recrutamento muscular em 15 indivíduos do género feminino e 15 indivíduos do género masculino com idades compreendidas entre os 18 e os 30 anos numa atividade de beber em três momentos diferentes. Para a análise cinemática foi utilizado o software Qualysis Motion Capture e para a análise eletromiográfica o software AcqKnowledge Analysis. Com os resultados obtidos constatamos que a percentagem de ativação muscular e os ângulos de flexão do ombro e flexão do cotovelo apresentam diferenças estatisticamente significativas (p<0.05) entre os géneros, sendo o grupo feminino a apresentar valores superiores. Aferiu-se também que a percentagem de ativação do músculo Deltoide Anterior parece ser influenciado pelo género (p<0.05) ao longo das três distâncias em estudo, sendo novamente o grupo feminino a apresentar valores superiores. Para além disto, aquando do movimento de alcançar, verificaram-se evidências estatísticas (p<0.05) do envolvimento do tronco em todas as distâncias de alcance do objeto, inclusive numa distância inferior ao comprimento do braço. Este estudo permitiu a descrição detalhada da eletromiografia e cinemática do movimento do membro superior de alcançar e transportar numa atividade diária, bem como uma comparação da mesma entre o grupo masculino e grupo feminino.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The basic function of the human hand is the manipulation and grasping of various objects in all daily activities, including work activities. This is greatly influenced by strength and manual dexterity. However age, gender and other contexts such as work or leisure activities could influence strength. Handgrip strength, a measure of maximum voluntary force of the hand, has proved to be reliable and valid as an objective parameter to evaluate the functional integrity of the hand as part of the musculoskeletal system. It correlates highly with strength in other muscular groups and is therefore considered as a good indicator of overall muscular strength and functional stress and could be used as a predictor of physical disability. Handgrip strength assessment is simple and reliable and used commonly by several investigators and health professionals, in different contexts (medical, nutritional, rehabilitation, professional settings, engineering, etc.) and with different purposes (research, diagnostic, assessment, etc.). In clinical and rehabilitation settings is of vital importance in the determination of effectiveness of several interventions and for monitoring evolution of diseases. Various ways (methods, techniques and equipments) of collecting information on grip strength have been reported. This chapter will review basic concepts on handgrip function, methodologies of assessment, contexts of application and correlates, such as physical activity, health or nutritional status. Several populations and reference values as also the relationships between handgrip and clinical status, aging, risk of disability and diseases, will be discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose - To verify the results of a diaphragmatic breathing technique (DBT) on diaphragmatic range of motion in healthy subjects. Methods - A total of 51 healthy subjects (10 male; 41 female), mean age 20 years old and a body mass index (BMI) ranging from 15.6 to 34.9 kg/m2, were enrolled in this study. Diaphragmatic range of motion was assessed by M-mode ultrasound imaging. Measurements were made before and after the DBT implementation in a standard protocol, based on 3 seconds of inspiration starting from a maximum expiration. Differences between assessments were analyzed by descriptive statistics and t-test (p < 0.05). Results - Mean value range of motion before DBT was 55.3 ± 13.4 mm and after DBT was 63.8 ± 13.2 mm showing a significant improvement of 8.5 ± 14.7 mm (p < 0.001). A strong correlation between the slope and the range of motion was found (r = 0.71, p < 0.001). Conclusions - Based on ultrasound measurements, it has been proved that DBT really contributes to a higher diaphragmatic range of motion. Future studies are needed in order to understand the influence of protocol parameters (e.g. inspiration time). Clinical implications - In the contest of evidence-based practice in physiotherapy, it has been showed by objective measurements that DBT improves the diaphragm range of motion, translating into a more efficient ventilatory function and thus can be used in clinical setting. To our knowledge this is the first study to assess the effects of DBT on range of motion of diaphragm muscle with ultrasound imaging.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular - Ramo de especialização: Intervenção Cardiovascular

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular - Ramo de especialização: Ultrassonografia Cardiovascular

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a programable perturbation and observation control implementation for a wind generation system and its power electronic converter. The objective of the method in this particular application is to adjust the power delivered to charge a battery to its maximum and allowable value, function of the real values of several parameters and their continuous variation, the most important the wind velocity and the turbine efficiency. Also, to improve the power throughput and to use the turbine and generator marginal zones of operation, an unusual power converter is used, allowing a wide range for the input voltage values. The implemented control is continuously measuring the actual power and looks for a new and powerful operation point. © 2014 IEEE.