997 resultados para OPTICAL TOMOGRAPHY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to the lack of studies about neurocysticercosis in the South of Brazil, an investigation was conducted to determine the percentage of suspected cases of neurocysticercosis in computed tomography diagnoses in Santa Maria, RS, from January 1997 to December 1998. Of 6300 computed tomographies (CT) of the skull performed at the private Hospital de Caridade Astrogildo de Azevedo, 80, i.e., 1.27% were suspected of neurocysticercosis. Fifty were women (62.5%) and 30 were men (37.5%). The most frequent radiological manifestation indicating neurocysticercosis was the presence of calcifications (isolated or associated), with a 95% rate (76 cases), while the presence of hypodense lesions reached a 5% rate (4 cases). After routine analysis, each CT was evaluated again and the suspected cases were confirmed. The percentage of suspected cases of neurocysticercosis detected by CT in the present study carried out in Santa Maria was considered low (1.27%). This can be explained by the fact that tomography is not accessible to the economically underprivileged population of Santa Maria. We hope that the present study can alert the population and the professionals to the fact that neurocysticercosis is a more frequent disease than indicated by the few diagnoses made.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cranial CT scans of eleven immunocompetent children with central nervous system (CNS) infection due to Cryptococcus neoformans var. gattii were retrospectively reviewed. These children had an average age of 8.8 years and positive culture for C. n. var. gattii in cerebrospinal fluid. The most common signs and symptoms were headache, fever, nuchal rigidity, nausea and vomiting. No normal cranial CT was detected in any patient. Hypodense nodules were observed in all patients . The remaining scan abnormalities were as follows: nine had diffuse atrophy, six had hydrocephalus, and five had hydrocephalus coexistent with diffuse atrophy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The total antioxidant capacity (TAC) of 28 flavoured water samples was assessed by ferric reducing antioxidant potential (FRAP), oxygen radical absorbance capacity (ORAC), trolox equivalent antioxidant capacity (TEAC) and total reactive antioxidant potential (TRAP) methods. It was observed that flavoured waters had higher antioxidant activity than the corresponding natural ones. The observed differences were attributed to flavours, juice and vitamins. Generally, higher TAC contents were obtained on lemon waters and lower values on guava and raspberry flavoured waters. Lower and higher TACs were obtained by TRAP and ORAC method, respectively. Statistical analysis suggested that vitamins and flavours increased the antioxidant content of the commercial waters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel optical disposable probe for screening fluoroquinolones in fish farming waters is presented, having Norfloxacin (NFX) as target compound. The colorimetric reaction takes place in the solid/liquid interface consisting of a plasticized PVC layer carrying the colorimetric reagent and the sample solution. NFX solutions dropped on top of this solid-sensory surface provided a colour change from light yellow to dark orange. Several metals were tested as colorimetric reagents and Fe(III) was selected. The main parameters affecting the obtained colour were assessed and optimised in both liquid and solid phases. The corresponding studies were conducted by visible spectrophotometry and digital image acquisition. The three coordinates of the HSL model system of the collected image (Hue, Saturation and Lightness) were obtained by simple image management (enabled in any computer). The analytical response of the optimised solid-state optical probe against concentration was tested for several mathematical transformations of the colour coordinates. Linear behaviour was observed for logarithm NFX concentration against Hue+Lightness. Under this condition, the sensor exhibited a limit of detection below 50 μM (corresponding to about 16 mg/mL). Visual inspection also enabled semi-quantitative information. The selectivity was ensured against drugs from other chemical groups than fluoroquinolones. Finally, similar procedure was used to prepare an array of sensors for NFX, consisting on different metal species. Cu(II), Mn(II) and aluminon were selected for this purpose. The sensor array was used to detect NFX in aquaculture water, without any prior sample manipulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cyanobacteria deteriorate the water quality and are responsible for emerging outbreaks and epidemics causing harmful diseases in Humans and animals because of their toxins. Microcystin-LR (MCT) is one of the most relevant cyanotoxin, being the most widely studied hepatotoxin. For safety purposes, the World Health Organization recommends a maximum value of 1 μg L−1 of MCT in drinking water. Therefore, there is a great demand for remote and real-time sensing techniques to detect and quantify MCT. In this work a Fabry–Pérot sensing probe based on an optical fibre tip coated with a MCT selective thin film is presented. The membranes were developed by imprinting MCT in a sol–gel matrix that was applied over the tip of the fibre by dip coating. The imprinting effect was obtained by curing the sol–gel membrane, prepared with (3-aminopropyl) trimethoxysilane (APTMS), diphenyl-dimethoxysilane (DPDMS), tetraethoxysilane (TEOS), in the presence of MCT. The imprinting effect was tested by preparing a similar membrane without template. In general, the fibre Fabry–Pérot with a Molecular Imprinted Polymer (MIP) sensor showed low thermal effect, thus avoiding the need of temperature control in field applications. It presented a linear response to MCT concentration within 0.3–1.4 μg L−1 with a sensitivity of −12.4 ± 0.7 nm L μg−1. The corresponding Non-Imprinted Polymer (NIP) displayed linear behaviour for the same MCT concentration range, but with much less sensitivity, of −5.9 ± 0.2 nm L μg−1. The method shows excellent selectivity for MCT against other species co-existing with the analyte in environmental waters. It was successfully applied to the determination of MCT in contaminated samples. The main advantages of the proposed optical sensor include high sensitivity and specificity, low-cost, robustness, easy preparation and preservation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We are presenting a simple, low-cost and rapid solid-state optical probe for screening chlorpromazine (CPZ) in aquacultures. The method exploits the colourimetric reaction between CPZ and Fe(III) ion that occurs at a solid/liquid interface, the solid layer consisting of ferric iron entrapped in a layer of plasticized PVC. If solutions containing CPZ are dropped onto such a layer, a colour change occurs from light yellow to dark pink or even light blue, depending on the concentration of CPZ. Visual inspection enables the concentration of CPZ to be estimated. The resulting colouration was also monitored by digital image collection for a more accurate quantification. The three coordinates of the hue, saturation and lightness system were obtained by standard image processing along with mathematical data treatment. The parameters affecting colour were assessed and optimized. Studies were conducted by visible spectrophotometry and digital image acquisition, respectively. The response of the optimized probe towards the concentration of CPZ was tested for several mathematical transformations of the colour coordinates, and a linear relation was found for the sum of hue and luminosity. The limit of detection is 50 μM (corresponding to about 16 μg per mL). The probe enables quick screening for CPZ in real water samples with prior sample treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adhesive bonding is an excellent alternative to traditional joining techniques such as welding, mechanical fastening or riveting. However, there are many factors that have to be accounted for during joint design to accurately predict the joint strength. One of these is the adhesive layer thickness (tA). Most of the results are for epoxy structural adhesives, tailored to perform best with small values of tA, and these show that the lap joint strength decreases with increase of tA (the optimum joint strength is usually obtained with tA values between 0.1 and 0.2 mm). Recently, polyurethane adhesives were made available in the market, designed to perform with larger tA values, and whose fracture behaviour is still not studied. In this work, the effect of tA on the tensile fracture toughness (View the MathML source) of a bonded joint is studied, considering a novel high strength and ductile polyurethane adhesive for the automotive industry. This work consists on the fracture characterization of the bond by a conventional and the J-integral techniques, which accurately account for root rotation effects. An optical measurement method is used for the evaluation of crack tip opening (δn) and adherends rotation at the crack tip (θo) during the test, supported by a Matlab® sub-routine for the automated extraction of these parameters. As output of this work, fracture data is provided in traction for the selected adhesive, enabling the subsequent strength prediction of bonded joints.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of adhesive joints has increased in recent decades due to its competitive features compared with traditional methods. This work aims to estimate the tensile critical strain energy release rate (GIC) of adhesive joints by the Double-Cantilever Beam (DCB) test. The J-integral is used since it enables obtaining the tensile Cohesive Zone Model (CZM) law. An optical measuring method was developed for assessing the crack tip opening (δn) and adherends rotation (θo). The proposed CZM laws were best approximated by a triangular shape for the brittle adhesive and a trapezoidal shape for the two ductile adhesives.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the objective to study the variation of optical properties of rat muscle during optical clearing, we have performed a set of optical measurements from that kind of tissue. The measurements performed were total transmittance, collimated transmittance, specular reflectance and total reflectance. This set of measurements is sufficient to determine diffuse reflectance and absorbance of the sample, also necessary to estimate the optical properties. All the performed measurements and calculated quantities will be used later in inverse Monte Carlo (IMC) simulations to determine the evolution of the optical properties of muscle during treatments with ethylene glycol and glucose. The results obtained with the measurements already provide some information about the optical clearing treatments applied to the muscle and translate the mechanisms of turning the tissue more transparent and sequence of regimes of optical clearing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study of agent diffusion in biological tissues is very important to understand and characterize the optical clearing effects and mechanisms involved: tissue dehydration and refractive index matching. From measurements made to study the optical clearing, it is obvious that light scattering is reduced and that the optical properties of the tissue are controlled in the process. On the other hand, optical measurements do not allow direct determination of the diffusion properties of the agent in the tissue and some calculations are necessary to estimate those properties. This fact is imposed by the occurrence of two fluxes at optical clearing: water typically directed out of and agent directed into the tissue. When the water content in the immersion solution is approximately the same as the free water content of the tissue, a balance is established for water and the agent flux dominates. To prove this concept experimentally, we have measured the collimated transmittance of skeletal muscle samples under treatment with aqueous solutions containing different concentrations of glucose. After estimating the mean diffusion time values for each of the treatments we have represented those values as a function of glucose concentration in solution. Such a representation presents a maximum diffusion time for a water content in solution equal to the tissue free water content. Such a maximum represents the real diffusion time of glucose in the muscle and with this value we could calculate the corresponding diffusion coefficient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study of chemical diffusion in biological tissues is a research field of high importance and with application in many clinical, research and industrial areas. The evaluation of diffusion and viscosity properties of chemicals in tissues is necessary to characterize treatments or inclusion of preservatives in tissues or organs for low temperature conservation. Recently, we have demonstrated experimentally that the diffusion properties and dynamic viscosity of sugars and alcohols can be evaluated from optical measurements. Our studies were performed in skeletal muscle, but our results have revealed that the same methodology can be used with other tissues and different chemicals. Considering the significant number of studies that can be made with this method, it becomes necessary to turn data processing and calculation easier. With this objective, we have developed a software application that integrates all processing and calculations, turning the researcher work easier and faster. Using the same experimental data that previously was used to estimate the diffusion and viscosity of glucose in skeletal muscle, we have repeated the calculations with the new application. Comparing between the results obtained with the new application and with previous independent routines we have demonstrated great similarity and consequently validated the application. This new tool is now available to be used in similar research to obtain the diffusion properties of other chemicals in different tissues or organs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation presented to obtain the PhD degree in Electrical and Computer Engineering - Electronics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Optical immersion clearing is a technique that has been widely studied for more than two decades and that is used to originate a temporary transparency effect in biological tissues. If applied in cooperation with clinical methods it provides optimization of diagnosis and treatment procedures. This technique turns biological tissues more transparent through two main mechanisms — tissue dehydration and refractive index (RI) matching between tissue components. Such matching is obtained by partial replacement of interstitial water by a biocompatible agent that presents higher RI and it can be completely reversible by natural rehydration in vivo or by assisted rehydration in ex vivo tissues. Experimental data to characterize and discriminate between the two mechanisms and to find new ones are necessary. Using a simple method, based on collimated transmittance and thickness measurements made from muscle samples under treatment, we have estimated the diffusion properties of glucose, ethylene glycol (EG) and water that were used to perform such characterization and discrimination. Comparing these properties with data from literature that characterize their diffusion in water we have observed that muscle cell membrane permeability limits agent and water diffusion in the muscle. The same experimental data has allowed to calculate the optical clearing (OC) efficiency and make an interpretation of the internal changes that occurred in muscle during the treatments. The same methodology can now be used to perform similar studies with other agents and in other tissues in order to solve engineering problems at design of inexpensive and robust technologies for a considerable improvement of optical tomographic techniques with better contrast and in-depth imaging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Intensive image surveillance after endovascular aneurysm repair is generally recommended due to continued risk of complications. However, patients at lower risk may not benefit from this strategy. We evaluated the predictive value of the first postoperative computed tomography angiography (CTA) characteristics for aneurysm-related adverse events as a means of patient selection for risk-adapted surveillance. METHODS: All patients treated with the Low-Permeability Excluder Endoprosthesis (W. L. Gore & Assoc, Flagstaff, Ariz) at a tertiary institution from 2004 to 2011 were included. First postoperative CTAs were analyzed for the presence of endoleaks, endograft kinking, distance from the lowermost renal artery to the start of the endograft, and for proximal and distal sealing length using center lumen line reconstructions. The primary end point was freedom from aneurysm-related adverse events. Multivariable Cox regression was used to test postoperative CTA characteristics as independent risk factors, which were subsequently used as selection criteria for low-risk and high-risk groups. Estimates for freedom from adverse events were obtained using Kaplan-Meier survival curves. RESULTS: Included were 131 patients. The median follow-up was 4.1 years (interquartile range, 2.1-6.1). During this period, 30 patients (23%) sustained aneurysm-related adverse events. Seal length <10 mm and presence of endoleak were significant risk factors for this end point. Patients were subsequently categorized as low-risk (proximal and distal seal length ≥10 mm and no endoleak, n = 62) or high-risk (seal length <10 mm or presence of endoleak, or both; n = 69). During follow-up, four low-risk patients (3%) and 26 high-risk patients (19%) sustained events (P < .001). Four secondary interventions were required in three low-risk patients, and 31 secondary interventions in 23 high-risk patients. Sac growth was observed in two low-risk patients and in 15 high-risk patients. The 5-year estimates for freedom from aneurysm-related adverse events were 98% for the low-risk group and 52% for the high-risk group. For each diagnosis, 81.7 image examinations were necessary in the low-risk group and 8.2 in the high-risk group. CONCLUSIONS: Our results suggest that the first postoperative CTA provides important information for risk stratification after endovascular aneurysm repair when the Excluder endoprosthesis is used. In patients with adequate seal and no endoleaks, the risk of aneurysm-related adverse events was significantly reduced, resulting in a large number of unnecessary image examinations. Adjusting the imaging protocol beyond 30 days and up to 5 years, based on individual patients' risk, may result in a more efficient and rational postoperative surveillance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO:Os recentes progressos na imagiologia médica possibilitaram um papel de destaque para a Tomografia Axial Computorizada Multicorte no estadiamento do carcinoma do estômago (GA). Foi objetivo deste estudo avaliar a acuidade desta técnica no estadiamento T (invasão mural) e N (ganglionar) e avaliar fatores de prognóstico como fatores de representação/substituição para melhorar a referida acuidade. Sessenta e nove pacientes operados a carcinoma gástrico (GA) entre Janeiro de 2010 e Julho de 2012 e avaliados por Tomografia Computorizada, a maioria recorrendo a técnica de multicorte com distensão gástrica, foram estadiados retrospetivamente por três imagiologistas. Utilizaram-se critérios de avaliação referidos na literatura especializada e fatores de substituição/representação nos estadios menos eficazes. O estadiamento T revelou acuidade de 66,7% e sensibilidade de 92% e a acuidade, sensibilidade e especificidade obtidas para o estadiamento N foram respetivamente 49%, 40,9% e 64%. Usando um fator de substituição de estadiamento diagnóstico T4/N2 para mudar o estadiamento N2 obtido por MDCT para estadiamento N3A aumentaria a acuidade do estadiamento N para 59% e a sensibilidade para 58,1% e baixaria a especificidade para 61,5%, embora essa mudança não fosse estatisticamente significativa (Teste exato de Fisher 0,159). Em conclusão a acuidade de uma técnica simples de MDCT com distensão gástrica no estadiamento T e N do GA está dentro dos valores citados na literatura e fatores de substituição/representação como o estadiamento T4 e o tipo Difuso da classificação de Lauren podem melhorar a acuidade do estadiamento N.-------------- ABSTRACT: Recent innovations in medical sectional imaging have allowed a major role of multi-detector computed tomography (MDCT) in staging of gastric adenocarcinoma (GA). The purpose of this study was to evaluate the accuracy of this technique in depth of mural invasion (T) and nodal (N) staging of GA and to evaluate prognostic factors as surrogate factors to improve such accuracy. Sixty nine patients operated to GA between January 2010 and July 2012 that underwent Computed Tomography, the majority through Multidetector Computed Tomography (MDCT) with gastric distention, were staged retrospectively by three imagiologists with state-of-the-art criteria and surrogate prognostic factors were analyzed for less accurate stages. MDCT T-staging was 66,7 % accurate with a sensibility of 92 % and there was a 49 % accuracy, 40,9 % sensibility and 64 % specificity for N Staging. Using a surrogate factor of T4/N2 diagnostic staging to change diagnostic MDCT N2 disease to N3A disease would increase accuracy of N staging to 59% and sensibility to 58,1% and would decrease specificity to 61,5 %, although that change was not statistically significant (Fisher´s Exact Test 0,159)In conclusion the accuracy of a simple hydro-MDCT technique in T and N staging of GA is in the range of values cited in the literature and surrogate factors as diagnostic T4 disease and diffuse type of Lauren´s Classification may improve the accuracy of N staging.