934 resultados para Neutral wire


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The evaluation of neutral pressures in soil mechanics problems is a fundamental step to evaluate deformations in soils. In this paper, we present some results obtained by using the boundary element method for plane problems, describing the undrained situation as well as the consolidation problem.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work shows a numerical procedure for bond between indented wires and concrete, and the coupled splitting of the concrete. The bond model is an interface, non-associative, plasticity model. It is coupled with a cohesive fracture model for concrete to take into account the splitting of such concrete. The radial component of the prestressing force, increased by Poisson’s effect, may split the surrounding concrete, decreasing the wire confinement and diminishing the bonding. The combined action of the bond and the splitting is studied with the proposed model. The results of the numerical model are compared with the results of a series of tests, such as those which showed splitting induced by the bond between wire and concrete. Tests with different steel indentation depths were performed. The numerical procedure accurately reproduces the experimental records and improves knowledge of this complex process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to achieve total selectivity at electrical distribution networks it is of great importance to analyze the defect currents at ungrounded power systems. This information will help to grant selectivity at electrical distribution networks ensuring that only the defect line or feeder is removed from service. In the present work a new selective and directional protection method for ungrounded power systems is evaluated. The new method measures only defect currents to detect earth faults and works with a directional criterion to determine the line under faulty conditions. The main contribution of this new technique is that it can detect earth faults in outgoing lines at any type of substation avoiding the possible mismatch of traditional directional earth fault relays. This detection technique is based on the comparison of the direction of a reference current to the direction of all earth fault capacitive currents at all the feeders connected to the same bus bars. This new method has been validated through computer simulations. The results for the different cases studied are remarkable, proving total validity and usefulness of the new method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The presented works aim at proposing a methodology for the simulation of offshore wind conditions using CFD. The main objective is the development of a numerical model for the characterization of atmospheric boundary layers of different stability levels, as the most important issue in offshore wind resource assessment. Based on Monin-Obukhov theory, the steady k-ε Standard turbulence model is modified to take into account thermal stratification in the surface layer. The validity of Monin-Obukhov theory in offshore conditions is discussed with an analysis of a three day episode at FINO-1 platform.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The collection of electrons from the ionosphere is the major problem facing high-power electrodynamic tethers. This article discusses a simple electron-collection concept which is free of most of the physical uncertainties associated with plasma contactors in the rarefied, magnetized environment of an orbiting tether. The idea is to leave exposed a fraction of the tether length near its anodic end, such that, when a positive bias develops locally with respect to the ambient plasma, and for a tether radius small compared with both thermal gyroradius and Debye length, electrons are collected in an orbital-motion-limited regime. It is shown that large currents can be drawn in this way with only moderate voltage drops. The concept is illustrated through a discussion of performance characteristics for generators and thrusters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BETs is a three-year project financed by the Space Program of the European Commission, aimed at developing an efficient deorbit system that could be carried on board any future satellite launched into Low Earth Orbit (LEO). The operational system involves a conductive tape-tether left bare to establish anodic contact with the ambient plasma as a giant Langmuir probe. As a part of this project, we are carrying out both numerical and experimental approaches to estimate the collected current by the positive part of the tether. This paper deals with experimental measurements performed in the IONospheric Atmosphere Simulator (JONAS) plasma chamber of the Onera-Space Environment Department. The JONAS facility is a 9- m3 vacuum chamber equipped with a plasma source providing drifting plasma simulating LEO conditions in terms of density and temperature. A thin metallic cylinder, simulating the tether, is set inside the chamber and polarized up to 1000 V. The Earth's magnetic field is neutralized inside the chamber. In a first time, tether collected current versus tether polarization is measured for different plasma source energies and densities. In complement, several types of Langmuir probes are used at the same location to allow the extraction of both ion densities and electron parameters by computer modeling (classical Langmuir probe characteristics are not accurate enough in the present situation). These two measurements permit estimation of the discrepancies between the theoretical collection laws, orbital motion limited law in particular, and the experimental data in LEO-like conditions without magnetic fields. In a second time, the spatial variations and the time evolutions of the plasma properties around the tether are investigated. Spherical and emissive Langmuir probes are also used for a more extensive characterization of the plasma in space and time dependent analysis. Results show the ion depletion because of the wake effect and the accumulation of- ions upstream of the tether. In some regimes (at large positive potential), oscillations are observed on the tether collected current and on Langmuir probe collected current in specific sites.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Bolund experiment has been reproduced in a neutral boundary layer wind tunnel (WT) at scale 1:115 for two Reynolds numbers. All the results have been obtained for an incoming flow from the 270o wind direction (transect B in the Bolund experiment jargon). Vertical scans of the velocity field are obtained using non-time resolved two components particle image velocimetry. Time-resolved velocity time series with a three component hot-wire probe have been also measured for transects at 2 and 5 m height and in the vertical transects at met masts M6, M3 and M8 locations. Special attention has been devoted to the detailed characterization of the inflow in order to reduce uncertainties in future comparisons with other physical and numerical simulations. Emphasis is placed on the analysis of spectral functions of the undisturbed flow and those of the flow above the island. The result?s reproducibility and trustworthiness have been addressed through redundancy measurements using particle image velocimetry, two and three components hot-wire anemometry. The bias in the prediction of the mean speed is similar to the one reported during the Bolund experiment by the physical modellers. However, certain reduction of the bias in the estimation of the turbulent kinetic energy is achieved. TheWT results of spectra and cosprectra have revealed a behaviour similar to the full-scale measurements in some relevant locations, showing that WT modelling can contribute to provide valid information about these important structural loading factors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A body with a shape similar to a hot wire with its sheath, but no prongs, has been placed close to the wall of a turbulent channel at Re_tau = 600. The results of the channel flow, without the wire, agree with previous published ones, despite the modest resolution and domain size. A simplified, two-dimensional version of the wire at the same Reynolds number has been studied to compare the dynamic response of cold and hot wires, where a slightly bigger perturbation is seen in the hot case, but an almost identical dynamic response. The cold wire seems to be able to measure instantaneous velocity with total drag after proper calibration. Being a DNS, the complete description of the flow field around the wire is obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study brings new insights on the hydrogen assisted stress corrosion on damage tolerance of a high-strength duplex stainless steel wire which concerns its potential use as active reinforcement for concrete prestressing. The adopted procedure was to experimentally state the effect of hydrogen on the damage tolerance of cylindrical smooth and precracked wire specimens exposed to stress corrosion cracking using the aggressive medium of the standard test developed by FIP (International Prestressing Federation). Stress corrosion testing, mechanical fracture tests and scanning electron microscopy analysis allowed the damage assessment, and explain the synergy between mechanical loading and environment action on the failure sequence of the wire. In presence of previous damage, hydrogen affects the wire behavior in a qualitative sense, consistently to the fracture anisotropy attributable to cold drawing, but it does not produce quantitative changes since the steel fully preserves its damage tolerance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The transient response of a system of independent electrodes buried in a semi-infinite conducting medium is studied. Using a simple and versatile numerical scheme written by the authors and based on the Electric Field Integral Equation (EFIE), the effect caused by harmonic signals ranging on frequency from Hz to hundred of MHz, and also by lightning type driving signal striking at a remote point far from the conductors, is extensively studied. The value of the scalar potential appearing on the electrodes as a function of the frequency of the applied signal is one of the variables investigated. Other features such as the input impedance at the injection point of the signal and the Ground Potential Rise (GPR) over the electrode system are also discussed

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present paper deals with the calculation of grounding resistance of an electrode composed of thin wires, that we consider here as perfect electric conductors (PEC) e.g. with null internal resistance, when buried in a soil of uniform resistivity. The potential profile at the ground surface is also calculated when the electrode is energized with low frequency current. The classic treatment by using leakage currents, called Charge Simulated Method (CSM), is compared with that using a set of steady currents along the axis of the wires, here called the Longitudinal Currents Method (LCM), to solve the Maxwell equations. The method of moments is applied to obtain a numerical approximation of the solution by using rectangular basis functions. Both methods are applied to two types of electrodes and the results are also compared with those obtained using a thirth approach, the Average Potential Method (APM), later described in the text. From the analysis performed, we can estimate a value of the error in the determination of grounding resistance as a function of the number of segments in which the electrodes are divided.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hybrid magnetic arrays embedded in superconducting films are ideal systems to study the competition between different physical (such as the coherence length) and structural length scales such as are available in artificially produced structures. This interplay leads to oscillation in many magnetically dependent superconducting properties such as the critical currents, resistivity and magnetization. These effects are generally analyzed using two distinct models based on vortex pinning or wire network. In this work, we show that for magnetic dot arrays, as opposed to antidot (i.e. holes) arrays, vortex pinning is the main mechanism for field induced oscillations in resistance R(H), critical current Ic(H), magnetization M(H) and ac-susceptibility χ ac(H) in a broad temperature range. Due to the coherence length divergence at Tc, a crossover to wire network behaviour is experimentally found. While pinning occurs in a wide temperature range up to Tc, wire network behaviour is only present in a very narrow temperature window close to Tc. In this temperature interval, contributions from both mechanisms are operational but can be experimentally distinguished.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

1D and 2D patterning of uncharged micro- and nanoparticles via dielectrophoretic forces on photovoltaic z-cut Fe:LiNbO3 have been investigated for the first time. The technique has been successfully applied with dielectric micro-particles of CaCO3 (diameter d = 1-3 μm) and metal nanoparticles of Al (d = 70 nm). At difference with previous experiments in x- and y-cut, the obtained patterns locally reproduce the light distribution with high fidelity. A simple model is provided to analyse the trapping process. The results show the remarkably good capabilities of this geometry for high quality 2D light-induced dielectrophoretic patterning overcoming the important limitations presented by previous configurations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este estudo avaliou o posicionamento ântero posterior dos primeiros molares inferiores, durante o tratamento ortodôntico, utilizando o arco lingual inferior como acessório de ancoragem na técnica Straight-Wire, em comparação aos casos tratados pela técnica Edgewise, sem a utilização do arco lingual. Dois grupos foram selecionados, ambos apresentando má oclusão de Classe I de Angle7, tratados com extração dos primeiros pré-molares superiores e inferiores. Foi utilizada uma amostra de 255 telerradiografias em norma lateral, obtidas de pacientes brasileiros, de ambos os sexos, com média de idade de 13 anos e 6 meses e com diferentes padrões de crescimento facial. Embasado na análise e discussão dos resultados, concluiu-se que: 1) do início do tratamento ao fim da fase de nivelamento, a perda de ancoragem coronária do primeiro molar inferior foi maior nos casos tratados com a técnica Straight-Wire; 2) do fim da fase de nivelamento ao fim do tratamento, a perda de ancoragem coronária e radicular do primeiro molar inferior foi maior na técnica Edgewise; 3) do início ao fim tratamento a perda de ancoragem radicular foi maior nos pacientes tratados com a técnica Edgewise; e 4) o deslocamento ântero-posterior dos incisivos inferiores não apresentou diferença estatisticamente significante para ambas as técnicas, em todas as etapas observadas.(AU)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este estudo avaliou o posicionamento ântero posterior dos primeiros molares inferiores, durante o tratamento ortodôntico, utilizando o arco lingual inferior como acessório de ancoragem na técnica Straight-Wire, em comparação aos casos tratados pela técnica Edgewise, sem a utilização do arco lingual. Dois grupos foram selecionados, ambos apresentando má oclusão de Classe I de Angle7, tratados com extração dos primeiros pré-molares superiores e inferiores. Foi utilizada uma amostra de 255 telerradiografias em norma lateral, obtidas de pacientes brasileiros, de ambos os sexos, com média de idade de 13 anos e 6 meses e com diferentes padrões de crescimento facial. Embasado na análise e discussão dos resultados, concluiu-se que: 1) do início do tratamento ao fim da fase de nivelamento, a perda de ancoragem coronária do primeiro molar inferior foi maior nos casos tratados com a técnica Straight-Wire; 2) do fim da fase de nivelamento ao fim do tratamento, a perda de ancoragem coronária e radicular do primeiro molar inferior foi maior na técnica Edgewise; 3) do início ao fim tratamento a perda de ancoragem radicular foi maior nos pacientes tratados com a técnica Edgewise; e 4) o deslocamento ântero-posterior dos incisivos inferiores não apresentou diferença estatisticamente significante para ambas as técnicas, em todas as etapas observadas.(AU)