893 resultados para Neuromuscular Electrical Stimulation, Near-Infrared Spectroscopy, Blood Flow, Fatigue, Motor Unit Recruitment, Isometric Contractions
Resumo:
The interaction between local and reflexive control of skin blood flow (SkBF) is unclear. This thesis isolated the roles of rectal (Tre) and local (Tloc) temperature on forearm SkBF regulation at normal and elevated body temperatures, and to investigate the interaction between local and reflexive SkBF control. While either normothermic (Tre ~37.0°C) or hyperthermic (∆Tre +1.1°C), SkBF was assessed on the dorsal aspect of each forearm in 10 participants while Tloc was manipulated in an A-B-A-B fashion between neutral (33.0°C) and hot (38.5°C). Finally, local heating to 44°C was performed to elicit maximal SkBF. Data are presented as a percentage of maximal cutaneous vascular conductance (CVC), calculated as laser-Doppler flux divided by mean arterial pressure. Tloc manipulations performed during normothermia had significantly greater effects on CVC than during hyperthermia. The decreased modification to SkBF from the Tloc changes during hyperthermia suggests that strong reflexive vasodilation attenuates local SkBF control mechanisms.
Resumo:
This thesis tested whether cognitive performance during passive heat stress may be affected by changes in cerebrovascular variables as opposed to strictly thermally-induced changes. A pharmacological reduction in cerebral blood flow (CBF) using indomethacin along with a hypocapnia-induced CBF reduction during passive heat stress (Tre ~1.5°C above baseline) were used to investigate any cerebrovascular-mediated changes in cognitive performance. Repeated measures analysis of variance indicated that One-Touch Stockings of Cambridge (OTS) performance was not affected by a significant reduction in CBF during passive heat stress. More specifically, OTS accuracy measures did not change as a result of either a reduction in CBF or increasing passive heat stress. However, it was found that OTS response time indices improved with increasing passive heat stress independent of CBF changes. In conclusion, a significant reduction in CBF does not cause additional changes in performance of an executive functioning task during severe passive heat stress.
Resumo:
Thèse numérisée par la Division de la gestion de documents et des archives de l'Université de Montréal.
Resumo:
Contexte L’américanisation des habitudes de vie, notamment de l’alimentation, semble être en grande partie responsable de l’augmentation incessante de l’incidence élevée des maladies cardiovasculaires. La période postprandiale, où l’homéostasie vasculaire et métabolique est mise à l’épreuve, est d’une importance considérable dans le développement ou la prévention de l’athérosclérose et représente maintenant la majeure partie du temps d’éveil. La compréhension de l’influence de la composition d’un repas sur son impact postprandial est donc essentielle dans notre lutte dans la prévention de ces maladies. Objectifs L’objectif principal de ce projet de recherche était d’étudier les réponses endothéliale et métabolique à un repas de type méditerranéen mixte (MMM), puisqu’elles sont inconnues. Ce projet avait aussi pour objectifs d’évaluer l’impact microvasculaire d’un tel repas et de caractériser la composition postprandiale des acides gras plasmatiques. À titre comparatif, ces éléments ont aussi été étudiés suite à un repas riche en gras saturés (HSFAM). Méthodes Vingt-huit (28) hommes sains, exempts de facteurs de risque de maladies cardiovasculaires ont reçu de façon randomisée les deux repas à l’étude. Le MMM, composé de saumon frais et de légumes cuits dans l'huile d'olive, contenait 7.87g de SFA et 2.29g d’acides gras polyinsaturés oméga-3, tandis que le HSFAM, composé d'un sandwich déjeuner avec œuf, saucisse et fromage, contenait 14.78g de SFA. Les mesures de la fonction endothéliale mesurée par échographie brachiale (FMD), de la fonction microvasculaire mesurée par spectroscopie proche de l’infrarouge (NIRS) et de la composition des acides gras plasmatique ont été effectuées à jeun et en période postprandiale. Résultats Deux sous-groupes de répondeurs aux repas à l’étude se sont dégagés de ces travaux. Un premier sous-groupe de sujets ayant une triglycéridémie à jeun élevée, mais normale (hnTG) a démontré des altérations endothéliales seulement suivant le repas HSFAM. Un second sous-groupe de sujets ayant une triglycéridémie plus faible et normale (lnTG) n’a quant à lui pas subi d’altérations endothéliales suivant les deux repas à l’étude. Les sujets hnTG ont aussi démontré une charge triglycéridémique postprandiale (iAUC) plus importante et qui était de surcroît enrichie en acide stéarique suivant la HSFAM et en acide gras polyinsaturés oméga-3 suivant le MMM. L’évaluation par NIRS de la fonction microvasculaire nous révèle un ralentissement de la réoxygénation post-ischémique qui suggère une altération postprandiale du recrutement capillaire chez les sujets hnTG seulement. De telles altérations, qui semblent être plus importantes suivant le HSFAM, pourraient être en partie responsables de l’impact endothélial de ce repas. Conclusions Cet essai clinique démontre donc de façon novatrice qu’un repas MMM n’a pas d’effet endothélial délétère et que cette neutralité est indépendante de la triglycéridémie à jeun. De plus, une triglycéridémie à jeun élevée mais normale semble indiquer des dysfonctions endothéliales et métaboliques à des épreuves nutritionnelles tel un repas HSFAM. La consommation de repas méditerranéens par des individus sains à la triglycéridémie marginale serait bénéfique, peut-être même davantage que pour des individus de triglycéridémie plus faible, dans la prévention de l’athérogénèse et des maladies cardiovasculaires.
Resumo:
Les objectifs de ce mémoire sont d’étudier la rétinotopie et les asymétries fonctionnelles du cortex visuel chez l’humain avec la spectroscopie proche de l’infrarouge fonctionnelle (SPIRf), tout en confirmant la fiabilité de cette technique. Tel qu’attendu, les résultats montrent une activation plus forte dans l’hémisphère controlatéral et dans le cortex haut/bas inverse à l’hémichamp stimulé. Nous avons également mesuré une activation significativement plus forte dans le cortex visuel supérieur (lorsque le champ visuel inférieur était stimulé) que l’activation dans le cortex visuel inférieur (lorsque le champ visuel supérieur était stimulé), surtout lorsque ces stimuli étaient présentés dans le champ visuel droit. Il s’agit de la première étude en SPIRf à observer les asymétries horizontale et verticale du cortex visuel et à ainsi confirmer l’existence de ces asymétries. Cette étude témoigne également de la fiabilité de la SPIRf comme technique d’imagerie pour cartographier le cerveau humain.
Resumo:
The vibrational overtone spectra 0f the liquid phase 1,2-dichloroethane and 1,2-dibromoethane in the spectral regions of CH stretching local mode overtones corresponding to delta v CH= = 2 to delta v CH=5 are reported. The observed spectral features are assigned using the local mode model. LocaI mode frequencies WCH and diagonal local mode anharmonicities XCH are obtained from an analysis of the spectra. The local-local combinations observed are interpreted on the basis of a coupled CH oscillator model hamiltonian. Local-normal combinations show complex structures and their possible assignments are given.
Resumo:
We have employed time-dependent local-spin-density theory to analyze the far-infrared transmission spectrum of InAs self-assembled nanoscopic rings recently reported [A. Lorke et al., Phys. Rev. Lett. (to be published)]. The overall agreement between theory and experiment is fairly good, which on the one hand confirms that the experimental peaks indeed reflect the ringlike structure of the sample, and on the other hand, asseses the suitability of the theoretical method to describe such nanostructures. The addition energies of one- and two-electron rings are also reported and compared with the corresponding capacitance spectra
Resumo:
Near-infrared spectroscopy can be a workhorse technique for materials analysis in industries such as agriculture, pharmaceuticals, chemicals and polymers. A near-infrared spectrum represents combination bands and overtone bands that are harmonics of absorption frequencies in the mid-infrared. Near-infrared absorption includes a combination-band region immediately adjacent to the mid-infrared and three overtone regions. All four near-infrared regions contain "echoes" of the fundamental mid-infrared absorptions. For example, vibrations in the mid-infrared due to the C-H stretches will produce four distinct bands in each of the overtone and combination regions. As the bands become more removed from the fundamental frequencies they become more widely separated from their neighbors, more broadened and are dramatically reduced in intensity. Because near-infrared bands are much less intense, more of the sample can be used to produce a spectra and with near-infrared, sample preparation activities are greatly reduced or eliminated so more of the sample can be utilized. In addition, long path lengths and the ability to sample through glass in the near-infrared allows samples to be measured in common media such as culture tubes, cuvettes and reaction bottles. This is unlike mid-infrared where very small amounts of a sample produce a strong spectrum; thus sample preparation techniques must be employed to limit the amount of the sample that interacts with the beam. In the present work we describe the successful the fabrication and calibration of a linear high resolution linear spectrometer using tunable diode laser and a 36 m path length cell and meuurement of a highly resolved structure of OH group in methanol in the transition region A v =3. We then analyse the NIR spectrum of certain aromatic molecules and study the substituent effects using local mode theory
Resumo:
Calculations of the absorption of solar radiation by atmospheric gases, and water vapor in particular, are dependent on the quality of databases of spectral line parameters. There has been increasing scrutiny of databases such as HITRAN in recent years, but this has mostly been performed on a band-by-band basis. We report nine high-spectral-resolution (0.03 cm(-1)) measurements of the solar radiation reaching the surface in southern England over the wave number range 2000 to 12,500 cm(-1) (0.8 to 5 mm) that allow a unique assessment of the consistency of the spectral line databases over this entire spectral region. The data are assessed in terms of the modeled water vapor column that is required to bring calculations and observations into agreement; for an entirely consistent database, this water vapor column should be constant with frequency. For the HITRAN01 database, the spread in water vapor column is about 11%, with distinct shifts between different spectral regions. The HITRAN04 database is in significantly better agreement (about 5% spread) in the completely updated 3000 to 8000 cm(-1) spectral region, but inconsistencies between individual spectral regions remain: for example, in the 8000 to 9500 cm(-1) spectral region, the results indicate an 18% (+/- 1%) underestimate in line intensities with respect to the 3000 to 8000 cm(-1) region. These measurements also indicate the impact of isotopic fractionation of water vapor in the 2500 to 2900 cm(-1) range, where HDO lines dominate over the lines of the most abundant isotope of H2O.
Resumo:
Techniques for obtaining quantitative values of the temperatures and concentrations of remote hot gaseous effluents from their measured passive emission spectra have been examined in laboratory experiments. The high sensitivity of the spectrometer in the vicinity of the 2397 cm-1 band head region of CO2 has allowed the gas temperature to be calculated from the relative intensity of the observed rotational lines. The spatial distribution of the CO2 in a methane flame has been reconstructed tomographically using a matrix inversion technique. The spectrometer has been calibrated against a black body source at different temperatures and a self absorption correction has been applied to the data avoiding the need to measure the transmission directly. Reconstruction artifacts have been reduced by applying a smoothing routine to the inversion matrix.
Resumo:
The gas phase reactions Of SiCl4 and Si2Cl6 With CH3OH and C2H5OH have been investigated using both mass spectrometry and matrix isolation techniques. SiCl4 reacts with both CH3OH and C2H5OH upon mixing of the vapours for times in excess of 3 h to generate the HCl-elimination products SiCl3OR (R = CH3 or C2H5). The identity of these products is confirmed by deuteration experiments and by ab initio calculations at the HF/6-31G(d) level. Further products are generated when the mixture is passed through a tube heated to 750degreesC. Si2Cl6 reacts with CH3OH and C2H5OH via a different mechanism in which the Si-Si bond is cleaved to yield SiCl3OR and HCl. Other products of the type SiCl4-n(OCH3)(n) are tentatively identified by a combination of mass spectrometric and matrix isolation measurements. These latter products indicate further replacement of Cl atoms by OR groups as a result of reaction of CH3OH or C2H5OH with the initial product.
Resumo:
An indoor rowing machine has been modified for functional electrical stimulation (FES) assisted rowing exercise in paraplegia. To perform the rowing manoeuvre successfully, however, the voluntarily controlled upper body movements must be co-ordinated with the movements of the electrically stimulated paralysed legs. To achieve such co-ordination, an automatic FES controller was developed that employs two levels of hierarchy. At the upper level, a finite state controller identifies the state or phase of the rowing cycle and activates the appropriate lower-level controller, in which electrical stimulation to the paralysed leg muscles is applied with reference to switching curves representing the desired seat velocity as a function of the seat position. In a pilot study, the hierarchical control of FES rowing was shown to be intuitive, reliable and easy to use. Compared with open-loop control of stimulation, all three variants of the closed-loop switching curve controllers used less muscle stimulation per rowing cycle (73% of the open-loop control on average). Further, the closed-loop controller that used switching curves derived from normal rowing kinematics used the lowest muscle stimulation (65% of the open-loop control) and was the most convenient to use for the client.