993 resultados para Near-Duplicate Detection
Resumo:
The transducer consists of a semiconductor device based on two stacked -i-n heterostructures that were designed to detect the emissions of the fluorescence resonance energy transfer between fluorophores in the cyan (470 nm) and yellow (588 nm) range of the spectrum. This research represents a preliminary study on the use of such wavelength-sensitive devices as photodetectors for this kind of application. The device was characterized through optoelectronic measurements concerning spectral response measurements under different electrical and optical biasing conditions. To simulate the fluorescence resonance energy transfer (FRET) pairs, a chromatic time-dependent combination of cyan and yellow wavelengths was applied to the device. The generated photocurrent was measured under reverse and forward bias to read out the output photocurrent signal. A different wavelength-biasing light was also superimposed. Results show that under reverse bias, the photocurrent signal presents four separate levels, each one assigned to the different wavelength combinations of the FRET pairs. If a blue background is superimposed, the yellow channel is enhanced and the cyan suppressed, while under red irradiation, the opposite behavior occurs. So, under suitable biasing light, the transducer is able to detect separately the cyan and yellow fluorescence pairs. An electrical model, supported by a numerical simulation, supports the transduction mechanism of the device.
Resumo:
Glucose sensing is an issue with great interest in medical and biological applications. One possible approach to glucose detection takes advantage of measuring changes in fluorescence resonance energy transfer (FRET) between a fluorescent donor and an acceptor within a protein which undergoes glucose-induced changes in conformation. This demands the detection of fluorescent signals in the visible spectrum. In this paper we analyzed the emission spectrum obtained from fluorescent labels attached to a protein which changes its conformation in the presence of glucose using a commercial spectrofluorometer. Different glucose nanosensors were used to measure the output spectra with fluorescent signals located at the cyan and yellow bands of the spectrum. A new device is presented based on multilayered a-SiC:H heterostructures to detect identical transient visible signals. The transducer consists of a p-i'(a-SiC:H)-n/p-i(a-Si:H)-n heterostructure optimized for the detection of the fluorescence resonance energy transfer between fluorophores with excitation in the violet (400 nm) and emissions in the cyan (470 nm) and yellow (588 nm) range of the spectrum. Results show that the device photocurrent signal measured under reverse bias and using appropriate steady state optical bias, allows the separate detection of the cyan and yellow fluorescence signals. (C) 2013 Elsevier B.V. All rights reserved.
Resumo:
The formation of amyloid structures is a neuropathological feature that characterizes several neurodegenerative disorders, such as Alzheimer´s and Parkinson´s disease. Up to now, the definitive diagnosis of these diseases can only be accomplished by immunostaining of post mortem brain tissues with dyes such Thioflavin T and congo red. Aiming at early in vivo diagnosis of Alzheimer´s disease (AD), several amyloid-avid radioprobes have been developed for b-amyloid imaging by positron emission tomography (PET) and single-photon emission computed tomography (SPECT). The aim of this paper is to present a perspective of the available amyloid imaging agents, special those that have been selected for clinical trials and are at the different stages of the US Food and Drugs Administration (FDA) approval.
Resumo:
Celiac disease is a gluten-induced autoimmune enteropathy characterized by the presence of tissue tranglutaminase (tTG) autoantibodies. A disposable electrochemical immunosensor (EI) for the detection of IgA and IgG type anti-tTG autoantibodies in real patient’s samples is presented. Screen-printed carbon electrodes (SPCE) nanostructurized with carbon nanotubes and gold nanoparticles were used as the transducer surface. This transducer exhibits the excellent characteristics of carbon–metal nanoparticle hybrid conjugation and led to the amplification of the immunological interaction. The immunosensing strategy consisted of the immobilization of tTG on the nanostructured electrode surface followed by the electrochemical detection of the autoantibodies present in the samples using an alkaline phosphatase (AP) labelled anti-human IgA or IgG antibody. The analytical signal was based on the anodic redissolution of enzymatically generated silver by cyclic voltammetry. The results obtained were corroborated with a commercial ELISA kit indicating that the electrochemical immunosensor is a trustful analytical screening tool.
Resumo:
The relentless discovery of cancer biomarkers demands improved methods for their detection. In this work, we developed protein imprinted polymer on three-dimensional gold nanoelectrode ensemble (GNEE) to detect epithelial ovarian cancer antigen-125 (CA 125), a protein biomarker associated with ovarian cancer. CA 125 is the standard tumor marker used to follow women during or after treatment for epithelial ovarian cancer. The template protein CA 125 was initially incorporated into the thin-film coating and, upon extraction of protein from the accessible surfaces on the thin film, imprints for CA 125 were formed. The fabrication and analysis of the CA 125 imprinted GNEE was done by using cyclic voltammetry (CV), differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS) techniques. The surfaces of the very thin, protein imprinted sites on GNEE are utilized for immunospecific capture of CA 125 molecules, and the mass of bound on the electrode surface can be detected as a reduction in the faradic current from the redox marker. Under optimal conditions, the developed sensor showed good increments at the studied concentration range of 0.5–400 U mL−1. The lowest detection limit was found to be 0.5 U mL−1. Spiked human blood serum and unknown real serum samples were analyzed. The presence of non-specific proteins in the serum did not significantly affect the sensitivity of our assay. Molecular imprinting using synthetic polymers and nanomaterials provides an alternative approach to the trace detection of biomarker proteins.
Resumo:
Mucin-16 (MUC16) is the established ovarian cancer marker used to follow the disease during or after treatment for epithelial ovarian cancer. The emerging science of cancer markers also demands for the new sensitive detection methods. In this work, we have developed an electrochemical immunosensor for antigen MUC16 using gold nanoelectrode ensemble (GNEE) and ferrocene carboxylic acid encapsulated liposomes tethered with monoclonal anti-Mucin-16 antibodies ( MUC16). GNEEs were fabricated by electroless deposition of the gold within the pores of polycarbonate track-etched membranes. Afterwards, MUC16 were immobilized on preformed self-assembled monolayer of cysteamine on the GNEE via cross-linking with EDC-Sulfo-NHS. A sandwich immunoassay was performed on MUC16 functionalized GNEE with MUC16 and immunoliposomes. The differential pulse voltammetry was employed to quantify the faradic redox response of ferrocene carboxylic acid released from immunoliposomes. The dose–response curve for MUC16 concentration was found between the range of 0.001–300 U mL−1. The lowest detection limit was found to be 5 × 10−4 U mL−1 (S/N = 3). We evaluated the performance of this developed immunosensor with commercial ELISA assay by comparing results obtained from spiked serum samples and real blood serum samples from volunteers.
Resumo:
Bacterial food poisoning is an ever-present threat that can be prevented with proper care and handling of food products. A disposable electrochemical immunosensor for the simultaneous measurements of common food pathogenic bacteria namely Escherichia coli O157:H7 (E. coli), campylobacter and salmonella were developed. The immunosensor was fabricated by immobilizing the mixture of anti-E. coli, anticampylobacter and anti-salmonella antibodies with a ratio of 1:1:1 on the surface of the multiwall carbon nanotube-polyallylamine modified screen printed electrode (MWCNT-PAH/SPE). Bacteria suspension became attached to the immobilized antibodies when the immunosensor was incubated in liquid samples. The sandwich immunoassay was performed with three antibodies conjugated with specific nanocrystal ( -E. coli-CdS, -campylobacter-PbS and -salmonella-CuS) which has releasable metal ions for electrochemical measurements. The square wave anodic stripping voltammetry (SWASV) was employed to measure released metal ions from bound antibody nanocrystal conjugates. The calibration curves for three selected bacteria were found in the range of 1 × 103 – 5 × 105 cells mL−1 with the limit of detection (LOD) 400 cells mL−1 for salmonella, 400 cells mL−1 for campylobacter and 800 cells mL−1 for E. coli. The precision and sensitivity of this method show the feasibility of multiplexed determination of bacteria in milk samples.
Resumo:
Projecto apresentado ao Instituto Politécnico do Porto para obtenção do Grau de Mestre em Logística Orientada por Prof. Doutor Gouveia
Resumo:
It is presented in this paper a study on the photo-electronic properties of multi layer a-Si: H/a-SiC: H p-i-n-i-p structures. This study is aimed to give an insight into the internal electrical characteristics of such a structure in thermal equilibrium, under applied Was and under different illumination condition. Taking advantage of this insight it is possible to establish a relation among-the electrical behavior of the structure the structure geometry (i.e. thickness of the light absorbing intrinsic layers and of the internal n-layer) and the composition of the layers (i.e. optical bandgap controlled through percentage of carbon dilution in the a-Si1-xCx: H layers). Showing an optical gain for low incident light power controllable by means of externally applied bias or structure composition, these structures are quite attractive for photo-sensing device applications, like color sensors and large area color image detector. An analysis based on numerical ASCA simulations is presented for describing the behavior of different configurations of the device and compared with experimental measurements (spectral response and current-voltage characteristic). (c) 2008 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Resumo:
This paper presents a proposal for an automatic vehicle detection and classification (AVDC) system. The proposed AVDC should classify vehicles accordingly to the Portuguese legislation (vehicle height over the first axel and number of axels), and should also support profile based classification. The AVDC should also fulfill the needs of the Portuguese motorway operator, Brisa. For the classification based on the profile we propose:he use of Eigenprofiles, a technique based on Principal Components Analysis. The system should also support multi-lane free flow for future integration in this kind of environments.
Resumo:
Liver steatosis is a common disease usually associated with social and genetic factors. Early detection and quantification is important since it can evolve to cirrhosis. In this paper, a new computer-aided diagnosis (CAD) system for steatosis classification, in a local and global basis, is presented. Bayes factor is computed from objective ultrasound textural features extracted from the liver parenchyma. The goal is to develop a CAD screening tool, to help in the steatosis detection. Results showed an accuracy of 93.33%, with a sensitivity of 94.59% and specificity of 92.11%, using the Bayes classifier. The proposed CAD system is a suitable graphical display for steatosis classification.
Resumo:
Liver steatosis is a common disease usually associated with social and genetic factors. Early detection and quantification is important since it can evolve to cirrhosis. Steatosis is usually a diffuse liver disease, since it is globally affected. However, steatosis can also be focal affecting only some foci difficult to discriminate. In both cases, steatosis is detected by laboratorial analysis and visual inspection of ultrasound images of the hepatic parenchyma. Liver biopsy is the most accurate diagnostic method but its invasive nature suggest the use of other non-invasive methods, while visual inspection of the ultrasound images is subjective and prone to error. In this paper a new Computer Aided Diagnosis (CAD) system for steatosis classification and analysis is presented, where the Bayes Factor, obatined from objective intensity and textural features extracted from US images of the liver, is computed in a local or global basis. The main goal is to provide the physician with an application to make it faster and accurate the diagnosis and quantification of steatosis, namely in a screening approach. The results showed an overall accuracy of 93.54% with a sensibility of 95.83% and 85.71% for normal and steatosis class, respectively. The proposed CAD system seemed suitable as a graphical display for steatosis classification and comparison with some of the most recent works in the literature is also presented.
Resumo:
Dissertação de Mestrado em Gestão e Conservação da Natureza
Resumo:
A presente dissertação descreve o desenvolvimento e a caracterização de sensores potenciométricos com base em polímeros de impressão molecular e de sensores ópticos com base em membranas de poli(cloreto de vinilo), PVC, para a determinação de cobre em vinhos verdes. Os sensores potenciométricos foram preparados a partir de diferentes solventes (metanol e clorofórmio), tendo o seu crescimento decorrido na presença ou ausência da molécula molde (cobre). Os sistemas sensores selectivos ao cobre continham partículas de polímeros com ou sem impressão molecular como material electroactivo, dispersas em solvente plastificante, PVC e, em alguns casos, aditivo aniónico. A avaliação dos vários sistemas baseou-se na comparação das características operacionais dos diversos eléctrodos onde foram aplicados. Estas características foram obtidas a partir de curvas de calibração, cujos declives e limites de detecção variaram entre -39,9 – 37,0 mV decada-1 e 4,2 – 29,1 μg mL-1, respectivamente. Os sensores não são independentes do pH uma vez que o complexo formado entre o cobre e a difenilcarbazida é favorecido por valores de pH próximos de 5. Assim, obtiveram-se melhores resultados usando água desionizada ou solução tampão de HEPES revelando-se um método rápido e relativamente eficaz nestas condições. Os sensores ópticos basearam-se na reacção colorimétrica entre o cobre e um complexante. Os reagentes complexantes escolhidos foram a neocuproína, a difenilcarbazida e o dietilditiocarbamato de sódio. Avaliou-se o efeito de vários parâmetros experimentais na resposta destes sensores, tais como o pH (avaliado para os valores 3,00 e 5,00), a concentração de cobre (que variou entre 0,06 e 317,7 mg L- 1) e as próprias características da membrana. Os melhores resultados foram obtidos a pH 3, numa gama de concentrações de 0,06 e 31,8 mg L-1 usando a difenilcarbazida como reagente complexante. A aplicação destes sensores a vinhos requer ainda estudos adicionais, especialmente no que diz respeito à necessidade de implementar algum procedimento de pré-tratamento de amostra.
Resumo:
Cada vez mais começa a notar-se, na indústria vitivinícola, uma grande preocupação com a qualidade dos seus produtos, motivada pela maior sensibilização e exigência dos consumidores. Deste modo, a presença de defeitos organoléticos no vinho representa uma fonte de perda financeira nesta indústria, pelo que o seu controlo se torna indispensável para que se obtenha um produto de elevada qualidade. Neste sentido, torna-se interessante desenvolver um método de análise que seja rápido de forma a permitir a quantificação simultânea das moléculas identificadas como principais responsáveis pelos distúrbios olfativos dos vinhos. Assim, este trabalho surge com o objetivo de implementar e validar um método para a determinação de contaminantes em vinho por microextração em fase sólida (SPME) e cromatografia gasosa acoplada à espetrometria de massa tandem (GC-MS/MS) e a sua correlação com a análise sensorial. A técnica de microextração em fase sólida é simples e rápida na medida em que não requer um pré-tratamento da amostra. Por sua vez, a análise por GC-MS permite identificar de forma clara os compostos em estudo, nomeadamente, 4-Etilfenol (4-EP), 4-Etilguaiacol (4-EG), 2,4,6-Tricloroanisol (TCA), 2,3,4,6-Tetracloroanisol (TeCA) e 2,4,6-Tribromoanisol (TBA). Foram realizados estudos de otimização das condições de extração, comparando as fibras 100 μm PDMS e 50/30 μm DVB/CAR/PDMS. Obtiveram-se resultados mais satisfatórios, em termos de resposta e da relação sinal/ruído, com a fibra 50/30 μm DVB/CAR/PDMS e estabeleceram-se como condições de extração 55ºC para a temperatura de incubação/extração, uma velocidade de agitação de 250 rpm e 60 minutos de tempo de extração. Ao longo deste trabalho, analisaram-se 50 amostras de vinho, das quais 48 eram amostras de Vinho Tinto do Douro e 2 de Vinho do Porto. Para validar a metodologia foram realizados estudos de linearidade, limiares analíticos, repetibilidade, precisão intermédia e recuperação. De um modo geral, obtiveram-se bons resultados ao nível da linearidade para as gamas de concentração escolhidas. Quanto aos limites de deteção e de quantificação, o 4-EP é o contaminante que apresenta uma gama de concentrações mais alta, notando-se limiares analíticos mais elevados, com valores próximos dos últimos níveis de concentração, oscilando entre 65 e 583 μg/L. No caso dos Anisóis, o TBA apresenta limites de deteção mais baixos, entre 0,4 e 17,0 ng/L. Os limiares analíticos foram validados com recurso a estudos de precisão intermédia e repetibilidade, cujos resultados se encontram dentro das especificações descritas no documento SANCO/10684/2009 (%RSD ≤ 30% para os Anisóis e %RSD ≤ 20% para os Fenóis Voláteis). Foram, ainda, realizados estudos de exatidão recorrendo a ensaios de recuperação e a ensaios interlaboratoriais. Muitas vezes conseguem-se boas recuperações, no entanto notam-se maiores dificuldades para o TBA e para o TeCA. Relativamente aos ensaios interlaboratoriais, verificam-se maiores discrepâncias para o 4-EP. Já os restantes contaminantes apresentam resultados, geralmente, satisfatórios (|z-score| ≤ 2).