972 resultados para Near infrared spectral(NIRS)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Wood is an extremely complex biological material, which can show macroscopic similarities that make it difficult to discriminate between species. Discrimination between similar wood species can be achieved by either anatomic or instrumental methods, such as near infrared spectroscopy (NIR). Although different spectroscopy methods are currently available, few studies have applied them to discriminate between wood species. In this study, we applied a partial least squares-discriminant analysis (PLS-DA) model to evaluate the viability of using direct fluorescence measurements for discriminating between Eucalyptus grandis, Eucalyptus urograndis, and Cedrela odorata. The results show that molecular fluorescence is an efficient technique for discriminating between these visually similar wood species. With respect to calibration and the validation samples, we observed no misclassifications or outliers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the modern warfare there is an active development of a new trend connected with a robotic warfare. One of the critical elements of robotics warfare systems is an automatic target recognition system, allowing to recognize objects, based on the data received from sensors. This work considers aspects of optical realization of such a system by means of NIR target scanning at fixed wavelengths. An algorithm was designed, an experimental setup was built and samples of various modern gear and apparel materials were tested. For pattern testing the samples of actively arm engaged armies camouflages were chosen. Tests were performed both in clear atmosphere and in the artificial extremely humid and hot atmosphere to simulate field conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of the present study was to demonstrate the wide applicability of the novel photoluminescent labels called upconverting phosphors (UCPs) in proximity-based bioanalytical assays. The exceptional features of the lanthanide-doped inorganic UCP compounds stem from their capability for photon upconversion resulting in anti-Stokes photoluminescence at visible wavelengths under near-infrared (NIR) excitation. Major limitations related to conventional photoluminescent labels are avoided, rendering the UCPs a competitive next-generation label technology. First, the background luminescence is minimized due to total elimination of autofluorescence. Consequently, improvements in detectability are expected. Second, at the long wavelengths (>600 nm) used for exciting and detecting the UCPs, the transmittance of sample matrixes is significantly greater in comparison with shorter wavelengths. Colored samples are no longer an obstacle to the luminescence measurement, and more flexibility is allowed even in homogeneous assay concepts, where the sample matrix remains present during the entire analysis procedure, including label detection. To transform a UCP particle into a biocompatible label suitable for bioanalytical assays, it must be colloidal in an aqueous environment and covered with biomolecules capable of recognizing the analyte molecule. At the beginning of this study, only UCP bulk material was available, and it was necessary to process the material to submicrometer-sized particles prior to use. Later, the ground UCPs, with irregular shape, wide size-distribution and heterogeneous luminescence properties, were substituted by a smaller-sized spherical UCP material. The surface functionalization of the UCPs was realized by producing a thin hydrophilic coating. Polymer adsorption on the UCP surface is a simple way to introduce functional groups for bioconjugation purposes, but possible stability issues encouraged us to optimize an optional silica-encapsulation method which produces a coating that is not detached in storage or assay conditions. An extremely thin monolayer around the UCPs was pursued due to their intended use as short-distance energy donors, and much attention was paid to controlling the thickness of the coating. The performance of the UCP technology was evaluated in three different homogeneous resonance energy transfer-based bioanalytical assays: a competitive ligand binding assay, a hybridization assay for nucleic acid detection and an enzyme activity assay. To complete the list, a competitive immunoassay has been published previously. Our systematic investigation showed that a nonradiative energy transfer mechanism is indeed involved, when a UCP and an acceptor fluorophore are brought into close proximity in aqueous suspension. This process is the basis for the above-mentioned homogeneous assays, in which the distance between the fluorescent species depends on a specific biomolecular binding event. According to the studies, the submicrometer-sized UCP labels allow versatile proximity-based bioanalysis with low detection limits (a low-nanomolar concentration for biotin, 0.01 U for benzonase enzyme, 0.35 nM for target DNA sequence).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to compare the hydrographically conditioned digital elevation models (HCDEMs) generated from data of VNIR (Visible Near Infrared) sensor of ASTER (Advanced Spaceborne Thermal Emission and Reflection Radiometer), of SRTM (Shuttle Radar Topography Mission) and topographical maps from IBGE in a scale of 1:50,000, processed in the Geographical Information System (GIS), aiming the morphometric characterization of watersheds. It was taken as basis the Sub-basin of São Bartolomeu River, obtaining morphometric characteristics from HCDEMs. Root Mean Square Error (RMSE) and cross validation were the statistics indexes used to evaluate the quality of HCDEMs. The percentage differences in the morphometric parameters obtained from these three different data sets were less than 10%, except for the mean slope (21%). In general, it was observed a good agreement between HCDEMs generated from remote sensing data and IBGE maps. The result of HCDEM ASTER was slightly higher than that from HCDEM SRTM. The HCDEM ASTER was more accurate than the HCDEM SRTM in basins with high altitudes and rugged terrain, by presenting frequency altimetry nearest to HCDEM IBGE, considered standard in this study.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In many industrial applications, such as the printing and coatings industry, wetting of porous materials by liquids includes not only imbibition and permeation into the bulk but also surface spreading and evaporation. By understanding these phenomena, valuable information can be obtained for improved process control, runnability and printability, in which liquid penetration and subsequent drying play important quality and economic roles. Knowledge of the position of the wetting front and the distribution/degree of pore filling within the structure is crucial in describing the transport phenomena involved. Although exemplifying paper as a porous medium in this work, the generalisation to dynamic liquid transfer onto a surface, including permeation and imbibition into porous media, is of importance to many industrial and naturally occurring environmental processes. This thesis explains the phenomena in the field of heatset web offset printing but the content and the analyses are applicable in many other printing methods and also other technologies where water/moisture monitoring is crucial in order to have a stable process and achieve high quality end products. The use of near-infrared technology to study the water and moisture response of porous pigmented structures is presented. The use of sensitive surface chemical and structural analysis, as well as the internal structure investigation of a porous structure, to inspect liquid wetting and distribution, complements the information obtained by spectroscopic techniques. Strong emphasis has been put on the scale of measurement, to filter irrelevant information and to understand the relationship between interactions involved. The near-infrared spectroscopic technique, presented here, samples directly the changes in signal absorbance and its variation in the process at multiple locations in a print production line. The in-line non-contact measurements are facilitated by using several diffuse reflectance probes, giving the absolute water/moisture content from a defined position in the dynamic process in real-time. The nearinfrared measurement data illustrate the changes in moisture content as the paper is passing through the printing nips and dryer, respectively, and the analysis of the mechanisms involved highlight the roles of the contacting surfaces and the relative liquid carrier properties of both non-image and printed image areas. The thesis includes laboratory studies on wetting of porous media in the form of coated paper and compressed pigment tablets by mono-, dual-, and multi-component liquids, and paper water/moisture content analysis in both offline and online conditions, thus also enabling direct sampling of temporal water/moisture profiles from multiple locations. One main focus in this thesis was to establish a measurement system which is able to monitor rapid changes in moisture content of paper. The study suggests that near-infrared diffuse reflectance spectroscopy can be used as a moisture sensitive system and to provide accurate online qualitative indicators, but, also, when accurately calibrated, can provide quantification of water/moisture levels, its distribution and dynamic liquid transfer. Due to the high sensitivity, samples can be measured with excellent reproducibility and good signal to noise ratio. Another focus of this thesis was on the evolution of the moisture content, i.e. changes in moisture content referred to (re)wetting, and liquid distribution during printing of coated paper. The study confirmed different wetting phases together with the factors affecting each phase both for a single droplet and a liquid film applied on a porous substrate. For a single droplet, initial capillary driven imbibition is followed by equilibrium pore filling and liquid retreat by evaporation. In the case of a liquid film applied on paper, the controlling factors defining the transportation were concluded to be the applied liquid volume in relation to surface roughness, capillarity and permeability of the coating giving the liquid uptake capacity. The printing trials confirmed moisture gradients in the printed sheet depending on process parameters such as speed, fountain solution dosage and drying conditions as well as the printed layout itself. Uneven moisture distribution in the printed sheet was identified to be one of the sources for waving appearance and the magnitude of waving was influenced by the drying conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Several tools of precision agriculture have been developed for specific uses. However, this specificity may hinder the implementation of precision agriculture due to an increasing in costs and operational complexity. The use of vegetation index sensors which are traditionally developed for crop fertilization, for site-specific weed management can provide multiple utilizations of these sensors and result in the optimization of precision agriculture. The aim of this study was to evaluate the relationship between reflectance indices of weeds obtained by the GreenSeekerTM sensor and conventional parameters used for weed interference quantification. Two experiments were conducted with soybean and corn by establishing a gradient of weed interference through the use of pre- and post-emergence herbicides. The weed quantification was evaluated by the normalized difference vegetation index (NDVI) and the ratio of red to near infrared (Red/NIR) obtained using the GreenSeekerTM sensor, the visual weed control, the weed dry matter, and digital photographs, which supplied information about the leaf area coverage proportions of weed and straw. The weed leaf coverage obtained using digital photography was highly associated with the NDVI (r = 0.78) and the Red/NIR (r = -0.74). The weed dry matter also positively correlated with the NDVI obtained in 1 m linear (r = 0.66). The results indicated that the GreenSeekerTM sensor originally used for crop fertilization could also be used to obtain reflectance indices in the area between rows of crops to support decision-making programs for weed control.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to determine the effect of respiratory muscle fatigue on intercostal and forearm muscle perfusion and oxygenation in patients with heart failure. Five clinically stable heart failure patients with respiratory muscle weakness (age, 66±12 years; left ventricle ejection fraction, 34±3%) and nine matched healthy controls underwent a respiratory muscle fatigue protocol, breathing against a fixed resistance at 60% of their maximal inspiratory pressure for as long as they could sustain the predetermined inspiratory pressure. Intercostal and forearm muscle blood volume and oxygenation were continuously monitored by near-infrared spectroscopy with transducers placed on the seventh left intercostal space and the left forearm. Data were compared by two-way ANOVA and Bonferroni correction. Respiratory fatigue occurred at 5.1±1.3 min in heart failure patients and at 9.3±1.4 min in controls (P<0.05), but perceived effort, changes in heart rate, and in systolic blood pressure were similar between groups (P>0.05). Respiratory fatigue in heart failure reduced intercostal and forearm muscle blood volume (P<0.05) along with decreased tissue oxygenation both in intercostal (heart failure, -2.6±1.6%; controls, +1.6±0.5%; P<0.05) and in forearm muscles (heart failure, -4.5±0.5%; controls, +0.5±0.8%; P<0.05). These results suggest that respiratory fatigue in patients with heart failure causes an oxygen demand/delivery mismatch in respiratory muscles, probably leading to a reflex reduction in peripheral limb muscle perfusion, featuring a respiratory metaboreflex.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Upconversion photoluminescence is a unique property of mostly certain inorganic materials, which are capable of converting low-energy infrared radiation into a higher-energy emission at visible wavelengths. This anti-Stokes shift enables luminescence detection without autofluorescence, which makes the upconverting materials a highly suitable reporter technology for optical biosensing applications. Furthermore, they exhibit long luminescence lifetime with narrow bandwidths also at the optical window of biomaterials enabling luminescence measurements in challenging sample matrices, such as whole blood. The aim of this thesis was to study the unique properties and the applicability of nano-sized upconverting phosphors (UCNPs) as reporters in biosensing applications. To render the inorganic nanophosphors water-dispersible and biocompatible, they were subjected to a series of surface modifications starting with silica-encapsulation and ending with a bioconjugation step with an analyte-recognizing biomolecule. The paramagnetism of the lanthanide dopants in the nanophosphors was exploited to develop a highly selective separation method for the UCNP-bioconjugates based on the magnetic selectivity of the high gradient magnetic separation (HGMS) system. The applicability of the nano-sized UCNPs as reporters in challenging sample matrices was demonstrated in two homogeneous sensing applications based on upconversion resonance energy transfer (UC-RET). A chemosensor for intracellular pH was developed exploiting UC-RET between the UCNP and a fluorogenic pH-sensitive dye with strongly increasing fluorescence intensity in decreasing pH. The pH-independent emission of the UCNPs at 550 nm was used for referencing. The applicability of the pH-nanosensor for intracellular pH measurement was tested in HeLa cells, and the acidic pH of endosomes could be detected with a confocal fluorescence microscope. Furthermore, a competitive UC-RET-based assay for red blood cell folic acid was developed for the measurement of folate directly from a whole blood sample. The optically transparent window of biomaterials was used in both the excitation and the measurement of the UC-RET sensitized emission of a near-infrared acceptor dye to minimize sample absorption, and the anti-Stokes detection completely eliminated the Stokes-shifted autofluorescence. The upconversion photoluminescence efficiency is known to be dependent on crystallite size, because the increasing surface-to-volume ratio of nano-sized UCNPs renders them more susceptible to quenching effects of the environment than their bulk counterpart. Water is known to efficiently quench the luminescence of lanthanide dopants. In this thesis, the quenching mechanism of water was studied using luminescence decay measurements. Water was found to quench the luminescence of UCNPs by increasing the non-radiative relaxation of the excited state of Yb3+ sensitizer ion, which had a very strong quenching effect on upconversion luminescence intensity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Point-of-care (POC) –diagnostics is a field with rapidly growing market share. As these applications become more widely used, there is an increasing pressure to improve their performance to match the one of a central laboratory tests. Lanthanide luminescence has been widely utilized in diagnostics because of the numerous advantages gained by the utilization of time-resolved or anti-Stokes detection. So far the use of lanthanide labels in POC has been scarce due to limitations set by the instrumentation required for their detection and the shortcomings, e.g. low brightness, of these labels. Along with the advances in the research of lanthanide luminescence, and in the field of semiconductors, these materials are becoming a feasible alternative for the signal generation also in the future POC assays. The aim of this thesis was to explore ways of utilizing time-resolved detection or anti-Stokes detection in POC applications. The long-lived fluorescence for the time-resolved measurement can be produced with lanthanide chelates. The ultraviolet (UV) excitation required by these chelates is cumbersome to produce with POC compatible fluorescence readers. In this thesis the use of a novel light-harvesting ligand was studied. This molecule can be used to excite Eu(III)-ions at wavelengths extending up to visible part of the spectrum. An enhancement solution based on this ligand showed a good performance in a proof-of-concept -bioaffinity assay and produced a bright signal upon 365 nm excitation thanks to the high molar absorptivity of the chelate. These features are crucial when developing miniaturized readers for the time-resolved detection of fluorescence. Upconverting phosphors (UCPs) were studied as an internal light source in glucose-sensing dry chemistry test strips and ways of utilizing their various emission wavelengths and near-infrared excitation were explored. The use of nanosized NaYF :Yb3+,Tm3+-particles enabled the replacement of an external UV-light source with a NIR-laser and gave an additional degree of freedom in the optical setup of the detector instrument. The new method enabled a blood glucose measurement with results comparable to a current standard method of measuring reflectance. Microsized visible emitting UCPs were used in a similar manner, but with a broad absorbing indicator compound filtering the excitation and emission wavelengths of the UCP. This approach resulted in a novel way of benefitting from the non-linear relationship between the excitation power and emission intensity of the UCPs, and enabled the amplification of the signal response from the indicator dye.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Using the Physical Vapor Transport method, single crystals of Cd2Re207 have been grown, and crystals of dimensions up to 8x6x2 mm have been achieved. X-ray diffraction from a single crystal of Cd2Re207 has showed the crystal growth in the (111) plane. Powder X-ray diffraction measurements were performed on ^^O and ^^O samples, however no difference was observed. Assigning the space group Fd3m to Cd2Re207 at room temperature and using structure factor analysis, the powder X-ray diffraction pattern of the sample was explained through systematic reflection absences. The temperatiure dependence of the resistivity measurement of ^^O has revealed two structural phase transitions at 120 and 200 K, and the superconducting transition at 1.0 K. Using Factor Group Analysis on three different structiures of Cd2Re207, the number of IR and Raman active phonon modes close to the Brillouin zone centre have been determined and the results have been compared to the temperature-dependence of the Raman shifts of ^^O and ^*0 samples. After scaling (via removing Bose-Einstein and Rayleigh scattering factors from the scattered light) all spectra, each spectrum was fitted with a number of Lorentzian peaks. The temperature-dependence of the FWHM and Raman shift of mode Eg, shows the effects of the two structurjil phase transitions above Tc. The absolute reflectance of Cd2Re207 - '^O single crystals in the far-infrared spectral region (7-700 cm~^) has been measured in the superconducting state (0.5 K), right above the superconducting state (1.5 K), and in the normal state (4.2 K). Thermal reflectance of the sample at 0.5 K and 1.5 K indicates a strong absorption feature close to 10 cm~^ in the superconducting state with a reference temperature of 4.2 K. By means of Kramers-Kronig analysis, the absolute reflectance was used to calculate the optical conductivity and dielectric function. The real part of optical conductivity shows five distinct active phonon modes at 44, 200, 300, 375, and 575 cm~' at all temperatures including a Drude-like behavior at low frequencies. The imaginary part of the calculated dielectric function indicates a mode softening of the mode 44 cm~' below Tc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Palladium and platinum complexes of pyridoxamine, pyridoxine and pyridoxal have been prepared. The structures of the complexes PtCI2PM.H20, trans-PdC12 (PN)2 and [PLH+ ]2[PtC16] 2- ,H20 have been determined by use of single crystal x-ray studies. The compounds PdC12PH, trans-PdC12 (PN) 2 , cis-PdCI2 (PN)2 and cis PdC12 (PL)2 were also studied by use of carbon-13 nmr spectroscopy. All the complexes have also been characterised by use of infrared spectral studies. In the complexes, PtCI2PM.H20 and PdC12PM, the ligand pyridoxamine is chela ted to the metal through the aminomethyl nitrogen and the phenolate oxygen atoms whereas in the complexes, trans-PdCI2 (PN)2' cis-PdCI2 (PN)2 and cis-PdC12 (PL)2 the vitamin B6 ligands are coordinated to the metal through the pyridine ring nitrogen. The compounds [PLH+ ]2[PtCI6] 2- .H20 and [PMH2] 2+ [PdCI4] 2- .H20have no direct metal-ligand bonding, In all the complexes, the metal maintains a square planar coordination except in [PLH +] 2[PtCI6] 2- ,H20 where the metal is octahedrally coordinated. PH pyridoxamine [PMH ] 2+ = diprotonated pyridoxamine 2 PN = pyridoxine PL pyridoxal PLH+ protonated pyridoxal

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Associée à d'autres techniques observationnelles, la polarimétrie dans le visible ou dans le proche infrarouge permet d'étudier la morphologie des champs magnétiques à la périphérie de nombreuses régions de formation stellaire. A l'intérieur des nuages molécualires la morphologie des champs est connue par polarimétrie submillimétrique, mais rarement pour les mêmes régions. Habituellement, il manque une échelle spatiale intermédiaire pour pouvoir comparer correctement la morphologie du champ magnétique galactique avec celle située à l'intérieur des nuages moléculaires. -- Cette thèse propose les moyens nécessaires pour réaliser ce type d'analyse multi-échelle afin de mieux comprendre le rôle que peuvent jouer les champs magnétiques dans les processus de formation stellaire. La première analyse traite de la région GF 9. Vient ensuite une étude de la morphologie du champ magnétique dans les filaments OMC-2 et OMC-3 suivie d'une analyse multi-échelle dans le complexe de nuages moléculaires Orion A dont OMC-2 et OMC-3 font partie. -- La synthèse des résultats couvrant GF 9 et Orion A est la suivante. Les approches statistiques employées montrent qu'aux grandes échelles spatiales la morphologie des champs magnétiques est poloïdale dans la région GF 9, et probablement hélicoïdale dans la région Orion A. A l'échelle spatiale des enveloppes des nuages moléculaires, les champs magnétiques apparaissent alignés avec les champs situés à leur périphérie. A l'échelle spatiale des coeurs, le champ magnétique poloïdal environnant la région GF 9 est apparemment entraîné par le coeur en rotation, et la diffusion ambipolaire n'y semble pas effective actuellement. Dans Orion A, la morphologie des champs est difficilement détectable dans les sites actifs de formation d'OMC-2, ou bien très fortement contrainte par les effets de la gravité dans OMC-1. Des effets probables de la turbulence ne seont détectés dans aucune des régions observées. -- Les analyses multi-échelles suggèrent donc qu'indépendamment du stade évolutif et de la gamme de masse des régions de formation stellaires, le champ magnétique galactique subit des modifications de sa morphologie aux échelles spatiales comparables à celles des coeurs protostellaires, de la même façon que les propriétés structurelles des nuages moléculaires suivent des lois d'autosimilarité jusqu'à des échelles comparables à celles des coeurs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Les naines brunes sont des astres incapables de déclencher et soutenir des réactions nucléaires dans leur cœur. En l’absence de cette source d’énergie, leur luminosité diminue avec le temps jusqu’à leur extinction complète. Leur flux aux longueurs d’onde de 0,8 à 2,35 μm est particulièrement altéré par l’humidité contenue dans l’atmosphère terrestre, ce qui complique l’étude de ces astres. Le but de la présente recherche est de vérifier si la division par un spectre d’étoile A0 est un moyen de corriger l’altération causée par l’atmosphère terrestre sur cette partie de leur spectre. Tout d’abord, des notions, pertinentes à la compréhension de ce travail, sont abordées. L’introduction présente quelques notions sur les naines brunes et sur l’atmosphère terrestre. Le deuxième chapitre concerne le traitement des données. Il traite de la calibration, de la mise en évidence du problème de non-répétabilité de la position de la fente du spectromètre SIMON ainsi que de ses causes. Il porte aussi sur l’uniformisation de la réponse des pixels et de la soustraction du ciel pour extraire les spectres. La méthode employée pour étudier l’effet de l’atmosphère terrestre sur les spectres de naines brunes y est présentée. Le troisième chapitre analyse les résultats obtenus par l’utilisation de l’étoile de référence de type A0 comme calibration pour corriger le spectre de naine brune, en assumant un même effet de l’atmosphère terrestre sur les deux types d’astres. Nous ne pouvons conclure, avec certitude, que l’absorption tellurique affecte de la même façon les deux spectres ni de quelle façon exactement ils sont affectés. Une recherche supplémentaire nécessitant de nouvelles prises de données à des masses d’air et à des taux d’humidité variés est requise.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La spectroscopie Raman est un outil non destructif fort utile lors de la caractérisation de matériau. Cette technique consiste essentiellement à faire l’analyse de la diffusion inélastique de lumière par un matériau. Les performances d’un système de spectroscopie Raman proviennent en majeure partie de deux filtres ; l’un pour purifier la raie incidente (habituellement un laser) et l’autre pour atténuer la raie élastique du faisceau de signal. En spectroscopie Raman résonante (SRR), l’énergie (la longueur d’onde) d’excitation est accordée de façon à être voisine d’une transition électronique permise dans le matériau à l’étude. La section efficace d’un processus Raman peut alors être augmentée d’un facteur allant jusqu’à 106. La technologie actuelle est limitée au niveau des filtres accordables en longueur d’onde. La SRR est donc une technique complexe et pour l’instant fastidieuse à mettre en œuvre. Ce mémoire présente la conception et la construction d’un système de spectroscopie Raman accordable en longueur d’onde basé sur des filtres à réseaux de Bragg en volume. Ce système vise une utilisation dans le proche infrarouge afin d’étudier les résonances de nanotubes de carbone. Les étapes menant à la mise en fonction du système sont décrites. Elles couvrent les aspects de conceptualisation, de fabrication, de caractérisation ainsi que de l’optimisation du système. Ce projet fut réalisé en étroite collaboration avec une petite entreprise d’ici, Photon etc. De cette coopération sont nés les filtres accordables permettant avec facilité de changer la longueur d’onde d’excitation. Ces filtres ont été combinés à un laser titane : saphir accordable de 700 à 1100 nm, à un microscope «maison» ainsi qu’à un système de détection utilisant une caméra CCD et un spectromètre à réseau. Sont d’abord présentés les aspects théoriques entourant la SRR. Par la suite, les nanotubes de carbone (NTC) sont décrits et utilisés pour montrer la pertinence d’une telle technique. Ensuite, le principe de fonctionnement des filtres est décrit pour être suivi de l’article où sont parus les principaux résultats de ce travail. On y trouvera entre autres la caractérisation optique des filtres. Les limites de basses fréquences du système sont démontrées en effectuant des mesures sur un échantillon de soufre dont la raie à 27 cm-1 est clairement résolue. La simplicité d’accordabilité est quant à elle démontrée par l’utilisation d’un échantillon de NTC en poudre. En variant la longueur d’onde (l’énergie d’excitation), différentes chiralités sont observées et par le fait même, différentes raies sont présentes dans les spectres. Finalement, des précisions sur l’alignement, l’optimisation et l’opération du système sont décrites. La faible acceptance angulaire est l’inconvénient majeur de l’utilisation de ce type de filtre. Elle se répercute en problème d’atténuation ce qui est critique plus particulièrement pour le filtre coupe-bande. Des améliorations possibles face à cette limitation sont étudiées.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La guérison des plaies cutanées appendiculaires chez le cheval, à la différence de celle des plaies corporelles, se complique régulièrement. Un retard de cicatrisation s’y observe et un tissu de granulation exubérant tend à s’y développer, le tout menant à une cicatrice pathologique hypertrophiée. La pathogénie exacte du tissu de granulation exubérant chez le cheval demeure inconnue à ce jour. Une hypoxie tissulaire pourrait favoriser son développement tout comme elle semble contribuer au développement de cicatrices cutanées pathologiques similaires observées chez l’Homme. L’objectif de cette étude était d’évaluer la perfusion vasculaire et la disponibilité locale en oxygène de plaies cutanées appendiculaires et corporelles en cours de cicatrisation normale et pathologique chez le cheval, à l’aide de la thermographie infrarouge et de la spectroscopie par réflectance dans le proche infrarouge. Six juments âgées de 3 à 4 ans ont été utilisées. Trois plaies cutanées ont été créées à l’aspect dorso-latéral du canon des membres thoraciques (plaies appendiculaires), et sur la paroi costale de l’un des hémithorax (plaies corporelles). Chez chaque jument, un canon a été aléatoirement bandé dans le but d’induire la formation de tissu de granulation exubérant dans les plaies s’y trouvant, tel que rapporté. La perfusion vasculaire et la disponibilité locale en oxygène ont été évaluées séquentiellement par thermographie infrarouge et spectroscopie par réflectance dans le proche infrarouge pour chaque plaie de chaque site (thorax; membre bandé; membre non bandé) au cours du processus de cicatrisation cutanée. Un modèle linéaire à doubles mesures répétées associé à une correction séquentielle de Bonferroni a révélé des différences significatives de perfusion vasculaire et de disponibilité locale en oxygène entre les plaies appendiculaires et corporelles. Ainsi la perfusion vasculaire et la disponibilité locale en oxygène étaient significativement plus élevées dans les plaies corporelles (P<0.05) et la perfusion vasculaire était significativement plus élevée dans les plaies appendiculaires non bandées que dans celles bandées (P<0.05). Nous avons récemment rapporté une plus grande occlusion de la micro-vascularisation au niveau des plaies appendiculaires chez le cheval. Nous rapportons maintenant que la perfusion vasculaire et la disponibilité locale en oxygène sont significativement inférieures dans les plaies appendiculaires, en particulier lorsqu’un tissu de granulation exubérant s’y développe. Compilés, ces résultats sous-tendent l’hypothèse que les plaies appendiculaires souffrent d’une altération de la perfusion vasculaire à l’origine possible d’une hypoxie tissulaire qui pourrait favoriser une cicatrisation cutanée anormale, telle la formation d’un tissu de granulation exubérant.