879 resultados para Multi-criteria Evaluation


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Matrix effects, which represent an important issue in liquid chromatography coupled to mass spectrometry or tandem mass spectrometry detection, should be closely assessed during method development. In the case of quantitative analysis, the use of stable isotope-labelled internal standard with physico-chemical properties and ionization behaviour similar to the analyte is recommended. In this paper, an example of the choice of a co-eluting deuterated internal standard to compensate for short-term and long-term matrix effect in the case of chiral (R,S)-methadone plasma quantification is reported. The method was fully validated over a concentration range of 5-800 ng/mL for each methadone enantiomer with satisfactory relative bias (-1.0 to 1.0%), repeatability (0.9-4.9%) and intermediate precision (1.4-12.0%). From the results obtained during validation, a control chart process during 52 series of routine analysis was established using both intermediate precision standard deviation and FDA acceptance criteria. The results of routine quality control samples were generally included in the +/-15% variability around the target value and mainly in the two standard deviation interval illustrating the long-term stability of the method. The intermediate precision variability estimated in method validation was found to be coherent with the routine use of the method. During this period, 257 trough concentration and 54 peak concentration plasma samples of patients undergoing (R,S)-methadone treatment were successfully analysed for routine therapeutic drug monitoring.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the antitumor activity and safety profile of plitidepsin administered as a 1h weekly intravenous (i.v.) infusion of 3.2mg/m(2) to patients with small cell lung cancer (SCLC) who relapsed or progressed after one line of chemotherapy. PATIENTS AND METHODS: This was a multicenter, open-label, single-arm, exploratory, phase II clinical trial. Treatment lasted until disease progression, unacceptable toxicity, patient refusal or treatment delay for >2 weeks. Objective response rate (primary efficacy endpoint) was evaluated according to response evaluation criteria in solid tumors (RECIST). The rate of stable disease (SD) lasting for at least 6 months and time-to-event variables were secondary endpoints of efficacy. Toxicity was assessed using National Cancer Institute Common Toxicity Criteria (NCI-CTC) version 2.0. RESULTS: Twenty pretreated SCLC patients (median age, 60 years) with extensive (n=13) or limited-stage disease (n=7) received a total of 24 treatment cycles (median, one cycle per patient; range, 1-2). Objective tumor responses were not observed and only one of the 17 evaluable patients had SD. With a median follow-up of 11.8 months, the progression-free survival and the median overall survival were 1.3 months and 4.8 months, respectively. The most troubling or common toxicities were fatigue, muscle weakness, lymphopenia, anemia (no patients showed neutropenia), and asymptomatic, non-cumulative increase of transaminases levels and alkaline phosphatase. CONCLUSION: This clinical trial shows that a cycle of 1h weekly i.v. infusion of plitidepsin (3.2mg/m(2)) was generally well tolerated other than fatigue and muscle weakness in patients with pretreated SCLC. One patient died due to multi-organ failure. The absence of antitumor activity found here precludes further studies of this plitidepsin schedule as second-line single-agent treatment of SCLC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper addresses the issue of policy evaluation in a context in which policymakers are uncertain about the effects of oil prices on economic performance. I consider models of the economy inspired by Solow (1980), Blanchard and Gali (2007), Kim and Loungani (1992) and Hamilton (1983, 2005), which incorporate different assumptions on the channels through which oil prices have an impact on economic activity. I first study the characteristics of the model space and I analyze the likelihood of the different specifications. I show that the existence of plausible alternative representations of the economy forces the policymaker to face the problem of model uncertainty. Then, I use the Bayesian approach proposed by Brock, Durlauf and West (2003, 2007) and the minimax approach developed by Hansen and Sargent (2008) to integrate this form of uncertainty into policy evaluation. I find that, in the environment under analysis, the standard Taylor rule is outperformed under a number of criteria by alternative simple rules in which policymakers introduce persistence in the policy instrument and respond to changes in the real price of oil.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Hypoglycemia, if recurrent, may have severe consequences on cognitive and psychomotor development of neonates. Therefore, screening for hypoglycemia is a daily routine in every facility taking care of newborn infants. Point-of-care-testing (POCT) devices are interesting for neonatal use, as their handling is easy, measurements can be performed at bedside, demanded blood volume is small and results are readily available. However, such whole blood measurements are challenged by a wide variation of hematocrit in neonates and a spectrum of normal glucose concentration at the lower end of the test range. We conducted a prospective trial to check precision and accuracy of the best suitable POCT device for neonatal use from three leading companies in Europe. Of the three devices tested (Precision Xceed, Abbott; Elite XL, Bayer; Aviva Nano, Roche), Aviva Nano exhibited the best precision. None completely fulfilled the ISO-accuracy-criteria 15197: 2003 or 2011. Aviva Nano fulfilled these criteria in 92% of cases while the others were <87%. Precision Xceed reached the 95% limit of the 2003 ISO-criteria for values ≤4.2 mmol/L, but not for the higher range (71%). Although validated for adults, new POCT devices need to be specifically evaluated on newborn infants before adopting their routine use in neonatology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study was undertaken to determine the accuracy of splenic palpation for the diagnosis of splenomegaly, and to determine whether the frequency of individuals with a palpable spleen in an endemic area can be considered as an index of morbidity of schistosomiasis. For the clinical diagnosis of splenomegaly, two criteria have been tested: (A) presence of a palpable spleen and (B) presence of a palpable spleen whose border could be felt more than 4 cm below the costal margin. In an area of high prevalence of the disease (66.3%) 285 individuals aged 18 years or more have been submitted to abdominal ultrasonography and physical examination. Splenomegaly was defined as a splenic length greater than 120 mm by ultrasound and the sensitivity, specificity, positive and negative predictive values of criterion A were 72.2%, 90.5%, 35.1% and 97.8%. The values for criterion B were 27.8%, 98%, 50% and 95%, respectively. In an non endemic area, 517 individuals were submitted to the same protocol and 22 individuals had a palpable spleen, but no patient fulfilled criterion B for splenomegaly, and only one met the ultrasonographic criterion for splenomegaly. The authors concluded that abdominal palpation is a poor method for the diagnosis of splenomegaly.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The goal of this study was to evaluate the diagnostic value of postmortem multi-computed tomography (MDCT) and MDCT-angiography for sudden cardiac deaths related to ischemic heart disease. Twenty three cases were selected based on clinical history and the results of native MDCT, multiphase post-mortem CT-angiography and conventional autopsy were compared. Radiological examination showed calcification of coronary arteries in 78% of the cases, most of which were not detailed at autopsy. MDCT-angiography allowed better visualization of the coronary arteries than MDCT and permitted the evaluation of stenoses and occlusions. Of the 14 cases of coronary thrombosis detected at conventional autopsy, 11 were visible as stop of perfusion with CT-angiography and three were found to be partly perfused. One case had an old thrombosis with collateral circulation. One case had a coronary artery postmortem clot found with MDCT-angiography. Coronary artery calcifications are more easily detected and documented with radiological examination than with conventional autopsy. MDCT is of limited diagnostic value for ischemic heart disease. MDCT-angiography, when correctly interpreted, is a reasonable tool to view the morphology of coronary arteries, rule out significant coronary artery stenoses, identify occlusions and direct sampling for histological examination.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Hypoglycaemia is a major cause of neonatal morbidity and may induce long-term developmental sequelae. Clinical signs of hypoglycaemia in neonatal infants are unspecific or even absent, and therefore, precise and accurate methods for the assessment of glycaemia are needed. Glycaemia measurement in newborns has some particularities like a very low limit of normal glucose concentration compared to adults and a large range of normal haematocrit values. Many bedside point-of-care testing (POCT) systems are available, but literature about their accuracy in newborn infants is scarce and not very convincing. In this retrospective study, we identified over a 1-year study period 1,324 paired glycaemia results, one obtained at bedside with one of three different POCT systems (Elite? XL, Ascensia? Contour? and ABL 735) and the other in the central laboratory of the hospital with the hexokinase reference method. All three POCT systems tended to overestimate glycaemia values, and none of them fulfilled the ISO 15197 accuracy criteria. The Elite XL appeared to be more appropriate than Contour to detect hypoglycaemia, however with a low specificity. Contour additionally showed an important inaccuracy with increasing haematocrit. The bench analyzer ABL 735 was the most accurate of the three tested POCT systems. Both of the tested handheld glucometers have important drawbacks in their use as screening tools for hypoglycaemia in newborn infants. ABL 735 could be a valuable alternative, but the blood volume needed is more than 15 times higher than for handheld glucometers. Before daily use in the newborn population, careful clinical evaluation of each new POCT system for glucose measurement is of utmost importance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Response evaluation in gastrointestinal stromal tumors is difficult. Computed tomography and size-based assessments have been found inadequate to draw prognostic conclusions in patients treated with tyrosine kinase inhibitors (TKI). Density criteria (CHOI) have recently been shown to better define prognostic subsets of patients evaluated with CT. Still, positron emission tomography (PET) might be better at identifying responders with good outcome early, as shown for first and recently second-line treatment in GIST (Prior et al.; J Clin Oncol 2009). We wanted to evaluate the role of PET in third- and fourth-line TKI treatment of GIST. Methods: We retrospectively reviewed patients with GIST who had received third- or fourth-line treatment with TKI and had undergone PET for response evaluation. Patient needed to have a baseline and at least one subsequent PET. Results of the first "early" PET after treatment start have been used throughout this analysis and EORTC PET Study Group criteria applied. Results: Twelve treatment courses were evaluable, seven with Nilotinib in third- and five with Sorafenib in fourth-line treatment, in 8 patients, median age 60 y (range 36−78 y), who had all failed prior Imatinib and Sunitinib treatment due to disease progession. Baseline and follow-up PET were performed within a median of 34 days (range 9−84 days). Median progression-free survival (PFS) was 262 days in patients responding to PET versus 76 days in patients with stable or progressing disease (p = 0.15). Conclusions: This small series suggests that PET retains its value for outcome prediction in third- and fourth-line TKI treatment of GIST. This could be of particular clinical value in these vulnerable patients with large tumour masses. Early PET may help in stopping ineffective, but toxic therapy and help switching to a more effective therapy. PET should be evaluated further in this patient population.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This service Aims: To provide a multi-component weight management service that supports sustainable behaviour change and weight loss in adults 16 years and over with a BMI 28. To enable patients to develop the necessary personal attributes for their own long term weight management and to understand the impact of their weight on their health and co-morbidities. Objectives: To provide an evidence based, multi-component tier 2 weight management service that improves patients knowledge and skills for effective and sustainable weight loss helps patients identify their own facilitators for positive behaviour change and to address underlying barriers to long-term behaviour changeincreases patients self-efficacy and confidence in their ability to address their weight To be an integral part of the tiered approach to weight management services for the population of Stockton. To ensure equitable service provision across Stockton-on-Tees. To provide intensive group based service, one-to-one support and maintenance support. To support the service user to develop and review a personalised goal setting plan phase 2 and at discharge after phase 2. To ensure a smooth transition from the service (tier2) to tier 1 services to ensure continuity of care for service users.Recruit referrals using a variety of and appropriate methods. To establish a single point of contact for referrals into the service.Continually promote the service across a range of mediums and liaise and work in partnership with key interdependencies (refer to 2.4) To establish a robust database and data collection system in line with information governance. To ensure the access criteria, care pathway and referral process is clearly understood by all health care professionals and those who may refer into the service. To establish close links with, and signpost and/or enable service users to access suitable services where patient needs indicate this. This may include access to Tees Time to Talk (IAPT) for psychological therapies; Specialist Weight Management Service; physical activity programmes; Tier 1 services; and primary care. To provide the necessary venues, equipment and assets needed to deliver the programme, ensuring due regard is given to the quality and safety of all materials used. To collect and provide data in quarterly reports to the Commissioner to allow for continued monitoring and evaluation of the service in line with the Standard Evaluation Framework (available at www.noo.org.uk/core/SEF) and as specified by the Commissioner.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Fáiltiú service provides information and advice on rights, entitlements and options to homeless people, or those at risk of homelessness. The objectives of this evaluation were to assess the information needs of users of the service, how effectively they were being met, and how they could be improved. Two focus groups of staff members and service users gave their views on the design and implementation of the research at the outset of the project. A screening questionnaire identified 78 people who used the Fáiltiú service in a specified time period, of whom 40 participated in the evaluation by giving their views on the service. The study reviewed the literature on homelessness, attempted to define the term, and examined the characteristics of homeless people and relevant Irish social policy. The conclusions reached were: users of the Fáiltiú service are marginalized in a number of ways and share characteristics related to poverty and social exclusion, such as poor educational qualifications, high levels of unemployment and experience of prison; their needs are multi-dimensional and include accommodation, financial, social and medical support, and access to employment and training services: the service needs to respond to these needs in a holistic way.This resource was contributed by The National Documentation Centre on Drug Use.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction We launched an investigator-initiated study(ISRCTN31181395) to evaluate the potential benefit of pharmacokinetic-guided dosage individualization of imatinib for leukaemia patients followed in public and private sectors. Following approval by the research ethics committee (REC) of the coordinating centre, recruitment throughout Switzerland necessitated to submit the protocol to 11 cantonal RECs.Materials and Methods We analysed requirements and evaluation procedures of the 12 RECs with associated costs.Results 1-18 copies of the dossier, in total 4300 printed pages, were required (printing/posting costs: ~300 CHF) to meet initial requirements. Meeting frequencies of RECs ranged between 2 weeks and 2 months, time from submission to first feedback took 2-75 days. Study approval was obtained from a chairman, a subor the full committee, the evaluation work being invoiced by 0-1000 CHF (median: 750 CHF, total: 9200 CHF). While 5 RECs gave immediate approval, the other 6 rose in total 38 queries before study release, mainly related to wording in the patient information, leading to 7 different final versions approved. Submission tasks employed an investigator half-time over about 6 months.Conclusion While the necessity of clinical research evaluation by independent RECs is undisputed, there is a need of further harmonization and cooperation in evaluation procedures. Current administrative burden is indeed complex, time-consuming and costly. A harmonized electronic application form, preferably compatible with other regulatory bodies and European countries, could increase transparency, improve communication, and encourage academic multi-centre clinical research in Switzerland.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. A software based tool has been developed (Optem) to allow automatize the recommendations of the Canadian Multiple Sclerosis Working Group for optimizing MS treatment in order to avoid subjective interpretation. METHODS: Treatment Optimization Recommendations (TORs) were applied to our database of patients treated with IFN beta1a IM. Patient data were assessed during year 1 for disease activity, and patients were assigned to 2 groups according to TOR: "change treatment" (CH) and "no change treatment" (NCH). These assessments were then compared to observed clinical outcomes for disease activity over the following years. RESULTS: We have data on 55 patients. The "change treatment" status was assigned to 22 patients, and "no change treatment" to 33 patients. The estimated sensitivity and specificity according to last visit status were 73.9% and 84.4%. During the following years, the Relapse Rate was always higher in the "change treatment" group than in the "no change treatment" group (5 y; CH: 0.7, NCH: 0.07; p < 0.001, 12 m - last visit; CH: 0.536, NCH: 0.34). We obtained the same results with the EDSS (4 y; CH: 3.53, NCH: 2.55, annual progression rate in 12 m - last visit; CH: 0.29, NCH: 0.13). CONCLUSION: Applying TOR at the first year of therapy allowed accurate prediction of continued disease activity in relapses and disability progression.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND. Total knee (TKR) and hip (THR) replacement (arthroplasty) are effective surgical procedures that relieve pain, improve patients' quality of life and increase functional capacity. Studies on variations in medical practice usually place the indications for performing these procedures to be highly variable, because surgeons appear to follow different criteria when recommending surgery in patients with different severity levels. We therefore proposed a study to evaluate inter-hospital variability in arthroplasty indication. METHODS. The pre-surgical condition of 1603 patients included was compared by their personal characteristics, clinical situation and self-perceived health status. Patients were asked to complete two health-related quality of life questionnaires: the generic SF-12 (Short Form) and the specific WOMAC (Western Ontario and Mcmaster Universities) scale. The type of patient undergoing primary arthroplasty was similar in the 15 different hospitals evaluated.The variability in baseline WOMAC score between hospitals in THR and TKR indication was described by range, mean and standard deviation (SD), mean and standard deviation weighted by the number of procedures at each hospital, high/low ratio or extremal quotient (EQ5-95), variation coefficient (CV5-95) and weighted variation coefficient (WCV5-95) for 5-95 percentile range. The variability in subjective and objective signs was evaluated using median, range and WCV5-95. The appropriateness of the procedures performed was calculated using a specific threshold proposed by Quintana et al for assessing pain and functional capacity. RESULTS. The variability expressed as WCV5-95 was very low, between 0.05 and 0.11 for all three dimensions on WOMAC scale for both types of procedure in all participating hospitals. The variability in the physical and mental SF-12 components was very low for both types of procedure (0.08 and 0.07 for hip and 0.03 and 0.07 for knee surgery patients). However, a moderate-high variability was detected in subjective-objective signs. Among all the surgeries performed, approximately a quarter of them could be considered to be inappropriate. CONCLUSIONS. A greater inter-hospital variability was observed for objective than for subjective signs for both procedures, suggesting that the differences in clinical criteria followed by surgeons when indicating arthroplasty are the main responsible factors for the variation in surgery rates.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Available screening tests for dementia are of limited usefulness because they are influenced by the patient's culture and educational level. The Eurotest, an instrument based on the knowledge and handling of money, was designed to overcome these limitations. The objective of this study was to evaluate the diagnostic accuracy of the Eurotest in identifying dementia in customary clinical practice. METHODS A cross-sectional, multi-center, naturalistic phase II study was conducted. The Eurotest was administered to consecutive patients, older than 60 years, in general neurology clinics. The patients' condition was classified as dementia or no dementia according to DSM-IV diagnostic criteria. We calculated sensitivity (Sn), specificity (Sp) and area under the ROC curves (aROC) with 95% confidence intervals. The influence of social and educational factors on scores was evaluated with multiple linear regression analysis, and the influence of these factors on diagnostic accuracy was evaluated with logistic regression. RESULTS Sixteen neurologists recruited a total of 516 participants: 101 with dementia, 380 without dementia, and 35 who were excluded. Of the 481 participants who took the Eurotest, 38.7% were totally or functionally illiterate and 45.5% had received no formal education. Mean time needed to administer the test was 8.2+/-2.0 minutes. The best cut-off point was 20/21, with Sn = 0.91 (0.84-0.96), Sp = 0.82 (0.77-0.85), and aROC = 0.93 (0.91-0.95). Neither the scores on the Eurotest nor its diagnostic accuracy were influenced by social or educational factors. CONCLUSION This naturalistic and pragmatic study shows that the Eurotest is a rapid, simple and useful screening instrument, which is free from educational influences, and has appropriate internal and external validity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Candida parapsilosis, currently divided into three distinct species, proliferates in glucose-rich solutions and has been associated with infections resulting from the use of medical devices made of plastic, an environment common in dialysis centres. The aims of this study were (i) to screen for Candida orthopsilosis and Candida metapsilosis (100 environmental isolates previously identified as C. parapsilosis), (ii) to test the ability of these isolates to form biofilm and (iii) to investigate the in vitro susceptibility of Candida spp biofilms to the antifungal agents, fluconazole (FLC) and amphotericin B (AMB). Isolates were obtained from a hydraulic circuit collected from a haemodialysis unit. Based on molecular criteria, 47 strains were re-identified as C. orthopsilosis and 53 as C. parapsilosis. Analyses using a formazan salt reduction assay and total viable count, together with microscopy studies, revealed that 72 strains were able to form biofilm that was structurally similar, but with minor differences in morphology. A microtitre-based colorimetric assay used to test the susceptibility of fungal biofilms to AMB and FLC demonstrated that the C. parapsilosis complex displayed an increased resistance to these antifungal agents. The results from these analyses may provide a basis for implementing quality controls and monitoring to ensure the microbiological purity of dialysis water, including the presence of yeast.