969 resultados para Minimally invasive approach
Resumo:
Pós-graduação em Biociências - FCLAS
Resumo:
Pós-graduação em Bases Gerais da Cirurgia - FMB
Resumo:
Study Objective: To estimate the concentration of natural killer (NK) cells in the peripheral blood in patients with and without endometriosis. Design: Case-control study (Canadian Task Force classification II-2). Setting: Tertiary referral hospital. Patients: One hundred fifty-five patients who had undergone videolaparoscopy were divided into 2 groups: those with endometriosis (n = 100) and those without endometriosis (n = 55). Interventions: The percentage of NK cells relative to peripheral lymphocytes was quantified at flow cytometry in 155 patients who had undergone laparoscopy. In addition to verifying the presence of endometriosis, stage of disease and the sites affected were also evaluated. Measurements and Main Results: The mean (SD) percentage of NK cells was higher (15.3% [9.8%]) in patients with endometriosis than in the group without the disease (10.6% [5.8%]) (p < .001). The percentage of NK cells was highest (19.8 [10.3%]) in patients with advanced stages of endometriosis and in those in whom the rectosigmoid colon was affected. In a statistical model of probability, the association of this marker (NK cells >= 11%) with the presence of symptoms such as pain and intestinal bleeding during menstruation and the absence of previous pregnancy yielded a 78% likelihood of the rectosigmoid colon being affected. Conclusion: Compared with patients without endometriosis, those with endometriosis demonstrate a higher concentration of peripheral NK cells. The percentage of NK cells is greater, primarily in patients with advanced stages of endometriosis involving the rectosigmoid colon. Therefore, it may serve as a diagnostic marker for this type of severe endometriosis, in particular if considered in conjunction with the symptoms. Journal of Minimally Invasive Gynecology (2012) 19, 317-324 (C) 2012 AAGL. All rights reserved.
Resumo:
Purpose: Duplex system is one of the most common anomalies of upper urinary tract. Anatomical and clinical presentation determine its treatment. Usually, the upper moiety has a poor function and requires resection, but when it is not significantly impaired, preservation is recommended. Laparoscopic reconstruction with upper pole preservation is presented as an alternative treatment. Materials and Methods: Four female patients with duplex system, one presenting with recurrent urinary tract infection and the others with urinary incontinence associated to infrasphincteric ectopic ureter, were treated. Surgical procedure envolved a laparoscopic ureteropyeloanastomosis of the upper pole ureter to the pelvis of the lower moiety, with prior insertion of a double J stent. Results: Surgical time varied from 120 to 150 minutes, with minimal blood loss in all cases. Follow-up varied from 15 to 30 months, with resolution of the clinical symptoms and preservation of the upper moiety function. Conclusion: Laparoscopic ureteropyeloanatomosis is a feasible and safe minimally invasive option in the treatment of duplex system.
Resumo:
The Nuss procedure requires the creation of a substernal tunnel for bar positioning. This is a manoeuvre that can be dangerous, and cardiac perforation has occurred in a few cases. Our purpose was to describe two technical modifications that enable the prevention of these fatal complications. A series of 25 patients with pectus excavatum were treated with a modification of the Nuss procedure that included the entrance in the left haemithorax first, and the use of the retractor to lift the sternum, with the consequent lowering displacement of the heart. These modified techniques have certain advantages: (i) the narrow anterior mediastinum between the sternum and the pericardial sac is expanded by pulling up the sternum; (ii) the thoracoscopic visualization of the tip of the introducer during tunnel creation is improved; (iii) the rubbing of the introducer against the pericardium is minimized; (iv) the exit path of the introducer can be guided by the surgeon's finger and (v) haemostasis and integrity of the pericardial sac can be more easily confirmed. We observed that with these manoeuvres, the risk of pericardial sac and cardiac injury can be markedly reduced.
Resumo:
Molecular dynamics simulations of the model protein chignolin with explicit solvent were carried out, in order to analyze the influence of the Berendsen thermostat on the evolution and folding of the peptide. The dependence of the peptide behavior on temperature was tested with the commonly employed thermostat scheme consisting of one thermostat for the protein and another for the solvent. The thermostat coupling time of the protein was increased to infinity, when the protein is not in direct contact with the thermal bath, a situation known as minimally invasive thermostat. In agreement with other works, it was observed that only in the last situation the instantaneous temperature of the model protein obeys a canonical distribution. As for the folding studies, it was shown that, in the applications of the commonly utilized thermostat schemes, the systems are trapped in local minima regions from which it has difficulty escaping. With the minimally invasive thermostat the time that the protein needs to fold was reduced by two to three times. These results show that the obstacles to the evolution of the extended peptide to the folded structure can be overcome when the temperature of the peptide is not directly controlled.
Resumo:
Introduction The “eversion” technique for carotid endarterectomy (e-CEA), that involves the transection of the internal carotid artery at the carotid bulb and its eversion over the atherosclerotic plaque, has been associated with an increased risk of postoperative hypertension possibly due to a direct iatrogenic damage to the carotid sinus fibers. The aim of this study is to assess the long-term effect of the e-CEA on arterial baroreflex and peripheral chemoreflex function in humans. Methods A retrospective review was conducted on a prospectively compiled computerized database of 3128 CEAs performed on 2617 patients at our Center between January 2001 and March 2006. During this period, a total of 292 patients who had bilateral carotid stenosis ≥70% at the time of the first admission underwent staged bilateral CEAs. Of these, 93 patients had staged bilateral e-CEAs, 126 staged bilateral s- CEAs and 73 had different procedures on each carotid. CEAs were performed with either the eversion or the standard technique with routine Dacron patching in all cases. The study inclusion criteria were bilateral CEA with the same technique on both sides and an uneventful postoperative course after both procedures. We decided to enroll patients submitted to bilateral e-CEA to eliminate the background noise from contralateral carotid sinus fibers. Exclusion criteria were: age >70 years, diabetes mellitus, chronic pulmonary disease, symptomatic ischemic cardiac disease or medical therapy with b-blockers, cardiac arrhythmia, permanent neurologic deficits or an abnormal preoperative cerebral CT scan, carotid restenosis and previous neck or chest surgery or irradiation. Young and aged-matched healthy subjects were also recruited as controls. Patients were assessed by the 4 standard cardiovascular reflex tests, including Lying-to-standing, Orthostatic hypotension, Deep breathing, and Valsalva Maneuver. Indirect autonomic parameters were assessed with a non-invasive approach based on spectral analysis of EKG RR interval, systolic arterial pressure, and respiration variability, performed with an ad hoc software. From the analysis of these parameters the software provides the estimates of spontaneous baroreflex sensitivity (BRS). The ventilatory response to hypoxia was assessed in patients and controls by means of classic rebreathing tests. Results A total of 29 patients (16 males, age 62.4±8.0 years) were enrolled. Overall, 13 patients had undergone bilateral e-CEA (44.8%) and 16 bilateral s-CEA (55.2%) with a mean interval between the procedures of 62±56 days. No patient showed signs or symptoms of autonomic dysfunction, including labile hypertension, tachycardia, palpitations, headache, inappropriate diaphoresis, pallor or flushing. The results of standard cardiovascular autonomic tests showed no evidence of autonomic dysfunction in any of the enrolled patients. At spectral analysis, a residual baroreflex performance was shown in both patient groups, though reduced, as expected, compared to young controls. Notably, baroreflex function was better maintained in e-CEA, compared to standard CEA. (BRS at rest: young controls 19.93 ± 2.45 msec/mmHg; age-matched controls 7.75 ± 1.24; e-CEA 13.85 ± 5.14; s-CEA 4.93 ± 1.15; ANOVA P=0.001; BRS at stand: young controls 7.83 ± 0.66; age-matched controls 3.71 ± 0.35; e-CEA 7.04 ± 1.99; s-CEA 3.57 ± 1.20; ANOVA P=0.001). In all subjects ventilation (VÝ E) and oximetry data fitted a linear regression model with r values > 0.8. Oneway analysis of variance showed a significantly higher slope both for ΔVE/ΔSaO2 in controls compared with both patient groups which were not different from each other (-1.37 ± 0.33 compared with -0.33±0.08 and -0.29 ±0.13 l/min/%SaO2, p<0.05, Fig.). Similar results were observed for and ΔVE/ΔPetO2 (-0.20 ± 0.1 versus -0.01 ± 0.0 and -0.07 ± 0.02 l/min/mmHg, p<0.05). A regression model using treatment, age, baseline FiCO2 and minimum SaO2 achieved showed only treatment as a significant factor in explaining the variance in minute ventilation (R2= 25%). Conclusions Overall, we demonstrated that bilateral e-CEA does not imply a carotid sinus denervation. As a result of some expected degree of iatrogenic damage, such performance was lower than that of controls. Interestingly though, baroreflex performance appeared better maintained in e-CEA than in s-CEA. This may be related to the changes in the elastic properties of the carotid sinus vascular wall, as the patch is more rigid than the endarterectomized carotid wall that remains in the e-CEA. These data confirmed the safety of CEA irrespective of the surgical technique and have relevant clinical implication in the assessment of the frequent hemodynamic disturbances associated with carotid angioplasty stenting.
Resumo:
The dramatic impact that vascular diseases have on human life quality and expectancy nowadays is the reason why both medical and scientific communities put great effort in discovering new and effective ways to fight vascular pathologies. Among the many different treatments, endovascular surgery is a minimally-invasive technique that makes use of X-ray fluoroscopy to obtain real-time images of the patient during interventions. In this context radiopaque biomaterials, i.e. materials able to absorb X-ray radiation, play a fundamental role as they are employed both to enhance visibility of devices during interventions and to protect medical staff and patients from X-ray radiations. Organic-inorganic hybrids are materials that combine characteristics of organic polymers with those of inorganic metal oxides. These materials can be synthesized via the sol-gel process and can be easily applied as thin coatings on different kinds of substrates. Good radiopacity of organic-inorganic hybrids has been recently reported suggesting that these materials might find applications in medical fields where X-ray absorption and visibility is required. The present PhD thesis aimed at developing and characterizing new radiopaque organic-inorganic hybrid materials that can find application in the vascular surgery field as coatings for the improvement of medical devices traceability as well as for the production of X-ray shielding objects and garments. Novel organic-inorganic hybrids based on different polyesters (poly-lactic acid and poly-ε-caprolactone) and polycarbonate (poly-trimethylene carbonate) as the polymeric phase and on titanium oxide as the inorganic phase were synthesized. Study of the phase interactions in these materials allowed to demonstrate that Class II hybrids (where covalent bonds exists between the two phases) can be obtained starting from any kind of polyester or polycarbonate, without the need of polymer pre-functionalization, thanks to the occurrence of transesterification reactions operated by inorganic molecules on ester and carbonate moieties. Polyester based hybrids were successfully coated via dip coating on different kinds of textiles. Coated textiles showed improved radiopacity with respect to the plain fabric while remaining soft to the touch. The hybrid was able to coat single fibers of the yarn rather than coating the yarn as a whole. Openings between yarns were maintained and therefore fabric breathability was preserved. Such coatings are promising for the production of light-weight garments for X-ray protection of medical staff during interventional fluoroscopy, which will help preventing pathologies that stem from chronic X-ray exposure. A means to increase the protection capacity of hybrid-coated fabrics was also investigated and implemented in this thesis. By synthesizing the hybrid in the presence of a suspension of radiopaque tantalum nanoparticles, PDMS-titania hybrid materials with tunable radiopacity were developed and were successfully applied as coatings. A solution for enhancing medical device radiopacity was also successfully investigated. High metal radiopacity was associated with good mechanical and protective properties of organic-inorganic hybrids in the form of a double-layer coating. Tantalum was employed as the constituent of the first layer deposited on sample substrates by means of a sputtering technique. The second layer was composed of a hybrid whose constituents are well-known biocompatible organic and inorganic components, such as the two polymers PCL and PDMS, and titanium oxide, respectively. The metallic layer conferred to the substrate good X-ray visibility. A correlation between radiopacity and coating thickness derived during this study allows to tailor radiopacity simply by controlling the metal layer sputtering deposition time. The applied metal deposition technique also permits easy shaping of the radiopaque layer, allowing production of radiopaque markers for medical devices that can be unambiguously identified by surgeons during implantation and in subsequent radiological investigations. Synthesized PCL-titania and PDMS-titania hybrids strongly adhered to substrates and show good biocompatibility as highlighted by cytotoxicity tests. The PDMS-titania hybrid coating was also characterized by high flexibility that allows it to stand large substrate deformations without detaching nor cracking, thus being suitable for application on flexible medical devices.
Resumo:
Nel corso degli anni diverse sono le tecniche proposte per il trattamento delle lesioni osteocondrali, da quelle mini-invasive con stimolazione midollare fino a quelle più aggressive basate sul trapianto di tessuti autologhi o eterologhi. Tutti questi metodi hanno comunque dei difetti ed è questo il motivo per cui il trattamento delle lesioni osteocondrali rappresenta tuttora una sfida per il chirurgo ortopedico, in considerazione dell’alta specializzazione e del basso potere di guarigione del tessuto cartilagineo. Buoni risultati sono stati ottenuti con innesti bioingegnerizzati o matrici polimeriche impiantati nei siti danneggiati. La quantità di scaffolds in uso per la riparazione condrale ed osteocondrale è molto ampia; essi differiscono non solo per il tipo di materiali usati per la loro realizzazione, ma anche per la presenza di promotori di una o più linee cellulari , su base condrogenica o osteogenica. Quando ci si approccia ad una lesione condrale di grandi dimensioni, l’osso sub-condrale è anch’esso coinvolto e necessita di trattamento per ottenere il corretto ripristino degli strati articolari più superficiali. La scelta più giusta sembra essere un innesto osteocondrale bioingegnerizzato, pronto per l’uso ed immediatamente disponibile, che consenta di effettuare il trattamento in un unico tempo chirurgico. Sulla base di questo razionale, dopo uno studio preclinico animale e previa autorizzazione del comitato etico locale, abbiamo condotto uno studio clinico clinico pilota utilizzando un nuovo innesto biomimetico nanostrutturato per il trattamento di lesioni condrali ed osteocondrali del ginocchio; la sua sicurezza e maneggevolezza, così come la facile riproducibilità della tecnica chirurgica ed i risultati clinici ottenuti sono stati valutati nel tempo a 6, 12, 24, 36 e 48 mesi dall’impianto in modo da testare il suo potenziale intrinseco senza l’aggiunta di alcuna linea cellulare.
Resumo:
La chirurgia con ultrasuoni focalizzati guidati da MRI (MR-g-FUS) è un trattamento di minima invasività, guidato dal più sofisticato strumento di imaging a disposizione, che utilizza a scopo diagnostico e terapeutico forme di energia non ionizzante. Le sue caratteristiche portano a pensare un suo possibile e promettente utilizzo in numerose aree della patologia umana, in particolare scheletrica. L'osteoma osteoide affligge frequentemente pazienti di giovane età, è una patologia benigna, con origine ed evoluzione non chiare, e trova nella termoablazione con radiofrequenza continua sotto guida CT (CT-g-RFA) il suo trattamento di elezione. Questo lavoro ha valutato l’efficacia, gli effetti e la sicurezza del trattamento dell’osteoma osteoide con MR-g-FUS. Sono stati presi in considerazione pazienti arruolati per MR-g-FUS e, come gruppo di controllo, pazienti sottoposti a CT-g-RFA, che hanno raggiunto un follow-up minimo di 18 mesi (rispettivamente 6 e 24 pazienti). Due pazienti erano stati esclusi dal trattamento MR-g-FUS per claustrofobia (2/8). Tutti i trattamenti sono stati portati a termine con successo tecnico e clinico. Non sono state registrate complicanze o eventi avversi correlati all’anestesia o alle procedure di trattamento, e tutti i pazienti sono stati dimessi regolarmente dopo 12-24 ore. La durata media dei trattamenti di MR-g-FUS è stata di 40±21 min. Da valori di score VAS pre-trattamento oscillanti tra 6 e 10 (su scala 0-10), i trattamenti hanno condotto tutti i pazienti a VAS 0 (senza integrazioni farmacologiche). Nessun paziente ha manifestato segni di persistenza di malattia o di recidiva al follow-up. Nonostante la neurolisi e la risoluzione dei sintomi, la perfusione del nidus è stata ritrovata ancora presente in oltre il 70% dei casi sottoposti a MR-g-FUS (4/6 pazienti). I risultati derivati da un'analisi estesa a pazienti più recentemente arruolati confermano questi dati. Il trattamento con MR-g-FUS sembra essere efficace e sicuro nel risolvere la sintomatologia dell'osteoma osteoide.
Resumo:
The present research thesis was focused on the development of new biomaterials and devices for application in regenerative medicine, particularly in the repair/regeneration of bone and osteochondral regions affected by degenerative diseases such as Osteoarthritis and Osteoporosis or serious traumas. More specifically, the work was focused on the synthesis and physico-chemical-morphological characterization of: i) a new superparamagnetic apatite phase; ii) new biomimetic superparamagnetic bone and osteochondral scaffolds; iii) new bioactive bone cements for regenerative vertebroplasty. The new bio-devices were designed to exhibit high biomimicry with hard human tissues and with functionality promoting faster tissue repair and improved texturing. In particular, recent trends in tissue regeneration indicate magnetism as a new tool to stimulate cells towards tissue formation and organization; in this perspective a new superparamagnetic apatite was synthesized by doping apatite lattice with di-and trivalent iron ions during synthesis. This finding was the pin to synthesize newly conceived superparamagnetic bone and osteochondral scaffolds by reproducing in laboratory the biological processes yielding the formation of new bone, i.e. the self-assembly/organization of collagen fibrils and heterogeneous nucleation of nanosized, ionically substituted apatite mimicking the mineral part of bone. The new scaffolds can be magnetically switched on/off and function as workstations guiding fast tissue regeneration by minimally invasive and more efficient approaches. Moreover, in the view of specific treatments for patients affected by osteoporosis or traumas involving vertebrae weakening or fracture, the present work was also dedicated to the development of new self-setting injectable pastes based on strontium-substituted calcium phosphates, able to harden in vivo and transform into strontium-substituted hydroxyapatite. The addition of strontium may provide an anti-osteoporotic effect, aiding to restore the physiologic bone turnover. The ceramic-based paste was also added with bio-polymers, able to be progressively resorbed thus creating additional porosity in the cement body that favour cell colonization and osseointegration.
Resumo:
Articular cartilage lesions, with their inherent limited healing potential, are hard to treat and remain a challenging problem for orthopedic surgeons. Despite the development of several treatment strategies, the real potential of each procedure in terms of clinical benefit and effects on the joint degeneration processes is not clear. Aim of this PhD project was to evaluate the results, both in terms of clinical and imaging improvement, of new promising procedures developed to address the challenging cartilage pathology. Several studies have been followed in parallel and completed over the 3-year PhD, and are reported in detail in the following pages. In particular, the studies have been focused on the evaluation of the treatment indications of a scaffold based autologous chondrocyte implantation procedure, documenting its results for the classic indication of focal traumatic lesions, as well as its use for the treatment of more challenging patients, older, with degenerative lesions, or even as salvage procedure for more advanced stages of articular degeneration. The second field of study involved the analysis of the results obtained treating lesions of the articular surface with a new biomimetic osteochondral scaffold, which showed promise for the treatment of defects where the entire osteochondral unit is involved. Finally, a new minimally invasive procedure based on the use of growth factors derived from autologous platelets has been explored, showing results and underlining indicatios for the treatment of cartilage lesions and different stages of joint degeneration. These studies shed some light on the potential of the evaluated procedures, underlining good results as well as limits, they give some indications on the most appropriate candidates for their application, and document the current knowledge on cartilage treatment procedures suggesting the limitations that need to be addressed by future studies to improve the management of cartilage lesions.
Resumo:
Oggetto della tesi e' l'approfondimento su tecniche e metodiche di preservazione del polmone isolato per lo studio ecografico. E' discussa l'appropriatezza sull'uso degli ultrasuoni in corso di chirurgia mini invasiva polmonare, obiettivo di una ricerca sperimentale. Il razionale dello studio si fonda sull'indicazione all'exeresi chirurgica di noduli polmonari di diametro inferiore al centometro, ovvero di diametro superiore ma localizzati in aree centrali del polmone. Queste lesioni sono sempre piu' frequentente diagnosticate per mezzo di avanzate tecniche di imaging. L'atto chirurgico ha scopo terapeutico quando sia stata posta la diagnosi di neoplasia maligna, diagnostico-terapeutico quando non sia ancora ottenuta la tipizzazione istologica della lesione. La tecnica toracoscopica offre numerosi vantaggi rispetto alle tecniche chirurgiche tradizionali ma presenta il grave limite di non permettere la palpazione diretta del tessuto polmonare e la localizzazione della formazione tumorale quando essa non sia visibile macroscopicamente. Gli ultrasuoni sono stati utilizzati con successo per indirizzare la localizzazione del nodulo polmonare. Scopo dello studio sperimentale e' quello di confrontare tecniche diverse di preservazione del polmone isolato in un modello animale, comparando catatteristiche e prestazioni di sonde ecografiche differenti per tipologia. Del tutto recentemente, in ambito trapiantologico, sono state proposte tecniche di preservazione organica utili ai fini di uno studio anatomico sperimentale particolareggiato (EVLP) e moderna e' da considerarsi la concezione di mezzi tecnici specifici per la localizzazione di bersagli intrapolmonari. La tecnica clinica applicata allo studio del particolare ecografico, nel modello animale, ha reso comprensibile e meglio definito il ruolo delle sonde ecografiche nell'individuazione di forme tumorali suscettibili di exeresi definitiva.
Resumo:
Radiation metabolomics can be defined as the global profiling of biological fluids to uncover latent, endogenous small molecules whose concentrations change in a dose-response manner following exposure to ionizing radiation. In response to the potential threat of nuclear or radiological terrorism, the Center for High-Throughput Minimally Invasive Radiation Biodosimetry was established to develop field-deployable biodosimeters based, in part, on rapid analysis by mass spectrometry of readily and easily obtainable biofluids. In this review, we briefly summarize radiation biology and key events related to actual and potential nuclear disasters, discuss the important contributions the field of mass spectrometry has made to the field of radiation metabolomics, and summarize current discovery efforts to use mass spectrometry-based metabolomics to identify dose-responsive urinary constituents, and ultimately to build and deploy a noninvasive high-throughput biodosimeter.
Resumo:
Ever since the first percutaneous transluminal angioplasty (PTA) was carried out in Switzerland in 1977, restenosis remains a major drawback of this minimally invasive treatment intervention. Numerous attempts to increase vessel patency after PTA have included systemic medications and endovascular brachytherapy, but these techniques have not met our expectations in preventing restenosis. Nitinol stents have been shown to reduce rates of restenosis and target lesion revascularization in patients undergoing endovascular treatment of long femoropopliteal obstructions. Despite further technical refinements in nitinol stent technology, restenosis occurs in approximately every third patient undergoing femoropopliteal stenting. Similarly, initial clinical trials with drug-eluting stents have failed to indicate restenosis inhibition in femoropopliteal segment. Unfortunately, restenosis rates after below-the-knee PTA and stenting have been reported to be even higher than those following femoropopliteal revascularization. Current concepts for the prevention and treatment of restenosis after PTA or stenting include the sustained release of antiproliferative paclitaxel into the vessel wall. Drug eluting balloons are a promising, novel technology aimed at inhibiting restenosis after PTA. Its clinical efficacy in reducing restenosis has already been proven for coronary arteries as well as for the femoropopliteal segment. The purpose of this article is to review the clinical utility of drug-eluting balloons for lower limb endovascular interventions.