968 resultados para MV PHOTONS
Resumo:
Context.Massive stars form in dense and massive molecular cores. The exact formation mechanism is unclear, but it is possible that some massive stars are formed by processes similar to those that produce the low-mass stars, with accretion/ejection phenomena occurring at some point of the evolution of the protostar. This picture seems to be supported by the detection of a collimated stellar wind emanating from the massive protostar IRAS 16547-4247. A triple radio source is associated with the protostar: a compact core and two radio lobes. The emission of the southern lobe is clearly non-thermal. Such emission is interpreted as synchrotron radiation produced by relativistic electrons locally accelerated at the termination point of a thermal jet. Since the ambient medium is determined by the properties of the molecular cloud in which the whole system is embedded, we can expect high densities of particles and infrared photons. Because of the confirmed presence of relativistic electrons, inverse Compton and relativistic Bremsstrahlung interactions are unavoidable. Aims.We aim to make quantitative predictions of the spectral energy distribution of the non-thermal spots generated by massive young stellar objects, with emphasis on the particular case of IRAS 16547-4247. Methods.We study the high-energy emission generated by the relativistic electrons which produce the non-thermal radio source in IRAS 16547-4247. We also study the result of proton acceleration at the terminal shock of the thermal jet and make estimates of the secondary gamma rays and electron-positron pairs produced by pion decay. Results.We present spectral energy distributions for the southern lobe of IRAS 16547-4247, for a variety of conditions. We show that high-energy emission might be detectable from this object in the gamma-ray domain. The source may also be detectable in X-rays through long exposures with current X-ray instruments. Conclusions.Gamma-ray telescopes such as GLAST, and even ground-based Cherenkov arrays of new generation can be used to study non-thermal processes occurring during the formation of massive stars.
Resumo:
INTRODUCTION: Mitral isthmus (MI) ablation is an effective option in patients undergoing ablation for persistent atrial fibrillation (AF). Achieving bidirectional conduction block across the MI is challenging, and predictors of MI ablation success remain incompletely understood. We sought to determine the impact of anatomical location of the ablation line on the efficacy of MI ablation. METHODS AND RESULTS: A total of 40 consecutive patients (87% male; 54 ± 10 years) undergoing stepwise AF ablation were included. MI ablation was performed in sinus rhythm. MI ablation was performed from the left inferior PV to either the posterior (group 1) or the anterolateral (group 2) mitral annulus depending on randomization. The length of the MI line (measured with the 3D mapping system) and the amplitude of the EGMs at 3 positions on the MI were measured in each patient. MI block was achieved in 14/19 (74%) patients in group 1 and 15/21 (71%) patients in group 2 (P = NS). Total MI radiofrequency time (18 ± 7 min vs. 17 ± 8 min; P = NS) was similar between groups. Patients with incomplete MI block had a longer MI length (34 ± 6 mm vs. 24 ± 5 mm; P < 0.001), a higher bipolar voltage along the MI (1.75 ± 0.74 mV vs. 1.05 ± 0.69 mV; P < 0.01), and a longer history of continuous AF (19 ± 17 months vs. 10 ± 10 months; P < 0.05). In multivariate analysis, decreased length of the MI was an independent predictor of successful MI block (OR 1.5; 95% CI 1.1-2.1; P < 0.05). CONCLUSIONS: Increased length but not anatomical location of the MI predicts failure to achieve bidirectional MI block during ablation of persistent AF.
Resumo:
The recent production of synthetic magnetic fields acting on electroneutral particles, such as atoms or photons, has boosted interest in the quantum Hall physics of bosons. Adding pseudospin 1/2 to the bosons greatly enriches the scenario, as it allows them to form an interacting integer quantum Hall (IQH) phase with no fermionic counterpart. Here we show that, for a small two-component Bose gas on a disk, the complete strongly correlated regime, extending from the integer phase at filling factor ν = 2 to the Halperin phase at filling factor ν = 2 / 3, is well described by composite fermionization of the bosons. Moreover we study the edge excitations of the IQH state, which, in agreement with expectations from topological field theory, are found to consist of forward-moving charge excitations and backward-moving spin excitations. Finally, we demonstrate how pair-correlation functions allow one to experimentally distinguish the IQH state from competing states, such as non-Abelian spin singlet (NASS) states.
Resumo:
Fluorescent proteins that can switch between distinct colors have contributed significantly to modern biomedical imaging technologies and molecular cell biology. Here we report the identification and biochemical analysis of a green-shifted red fluorescent protein variant GmKate, produced by the introduction of two mutations into mKate. Although the mutations decrease the overall brightness of the protein, GmKate is subject to pH-dependent, reversible green-to-red color conversion. At physiological pH, GmKate absorbs blue light (445 nm) and emits green fluorescence (525 nm). At pH above 9.0, GmKate absorbs 598 nm light and emits 646 nm, far-red fluorescence, similar to its sequence homolog mNeptune. Based on optical spectra and crystal structures of GmKate in its green and red states, the reversible color transition is attributed to the different protonation states of the cis-chromophore, an interpretation that was confirmed by quantum chemical calculations. Crystal structures reveal potential hydrogen bond networks around the chromophore that may facilitate the protonation switch, and indicate a molecular basis for the unusual bathochromic shift observed at high pH. This study provides mechanistic insights into the color tuning of mKate variants, which may aid the development of green-to-red color-convertible fluorescent sensors, and suggests GmKate as a prototype of genetically encoded pH sensors for biological studies.
Resumo:
Measles, caused by measles virus (MV), is a highly contagious viral disease causing severe respiratory infection and a typical rash. Despite the availability of a protective vaccine, measles is still the leading vaccine-preventable cause of childhood mortality worldwide. The high mortality associated with the disease is mainly due to an increased susceptibility to secondary infections during the period of immunosuppression that continues for several weeks after recovery. The present study was undertaken to elucidate the role of cytoskeletal components in the regulation of MV infection. The most interesting finding was that MV replication was activated in unstimulated peripheral blood mononuclear cells (PBMC) when globular actin was converted into the filamentous form with jasplakinolide. This provides a new aspect in our understanding of MV infection in PBMC. In the second part of the thesis we investigated MV-induced structural changes of cellular nuclear matrix, which is a proteinaceous framework of the nucleus similar to the cytoskeleton in the cytoplasm. We showed that cleavage of nuclear markers was virusspecific and a general caspase inhibitor rescued MV-infected cells from cell death. Furthermore, we studied MV-induced innate immune mechanisms in lung epithelial and endothelial cells. Our results showed that MV infection resulted in activation of the double stranded RNA (dsRNA) binding molecules melanoma differentiation-associated gene 5 (mda-5), retinoic acid inducible gene I (RIG-I), and toll-like receptor 3 (TLR3) gene expression, followed by high expression of antiviral cytokine mRNA.
Resumo:
OBJETIVO: Desenvolvimento e implementação de um programa, fundamentado no algoritmo de cálculo manual, para verificação dos cálculos de unidades monitoras em radioterapia e estabelecimento de patamares de aceitação, como mecanismo de garantia da qualidade. MATERIAIS E MÉTODOS: Os dados apresentados foram obtidos a partir dos aceleradores lineares modelo Clinac 600C e 2100C, da Varian, e o sistema de planejamento de tratamento computadorizado utilizado foi o CadPlan™. RESULTADOS: Para os feixes de 6 MV os patamares de aceitação para desvios entre os cálculos de unidades monitoras, separados por região de tratamento, foram: mama (0,0% ± 1,7%), cabeça e pescoço (1,5% ± 0,5%), hipófise (-1,7% ± 0,5%), pelve (2,1% ± 2,1%) e tórax (0,2% ± 1,3%). Para os feixes de 15 MV, o patamar sugerido para pelve em todas as técnicas de tratamento foi de (3,2% ± 1,3%). CONCLUSÃO: Os dados são suficientes para justificar seu uso na prática clínica como ferramenta no programa de garantia da qualidade.
Resumo:
We present a model for transport in multiply scattering media based on a three-dimensional generalization of the persistent random walk. The model assumes that photons move along directions that are parallel to the axes. Although this hypothesis is not realistic, it allows us to solve exactly the problem of multiple scattering propagation in a thin slab. Among other quantities, the transmission probability and the mean transmission time can be calculated exactly. Besides being completely solvable, the model could be used as a benchmark for approximation schemes to multiple light scattering.
Resumo:
OBJETIVO: Avaliar a reprodutibilidade do posicionamento de pacientes com diagnóstico de câncer de próstata submetidos a radioterapia conformada. MATERIAIS E MÉTODOS: Foram avaliados 960 (posições anterior e lateral) filmes radiológicos, de um total de 120 pacientes que receberam radioterapia conformada na próstata com técnica isocêntrica. As imagens foram obtidas em acelerador linear de partículas 6 MV. Aplicou-se protocolo específico para planejamento e tratamento da próstata, com o paciente em posição supina, mãos colocadas sobre o tórax, pés apoiados em suporte apropriado. Diariamente, os pacientes foram posicionados conforme demarcações na pele, coincidentes com os lasers da sala. Os filmes radiológicos foram comparados com as radiografias reconstruídas digitalmente (digitally reconstructed radiography - DRR) em sistema de planejamento computadorizado Eclipse, a partir das tomografias. As radiografias de posicionamento foram realizadas no primeiro dia e após, semanalmente, até o término do tratamento. RESULTADOS: As médias dos deslocamentos observados foram de 1,99 ± 1,25 mm no sentido crânio-caudal, 1,37 ± 0,84 mm no látero-lateral e 1,94 ± 1,10 mm no ântero-posterior. CONCLUSÃO: O uso de protocolos específicos para posicionamento dos pacientes é possível na prática clínica, possibilita reprodutibilidade adequada e rápida correção dos possíveis erros.
Resumo:
Prompt production of charmonium χ c0, χ c1 and χ c2 mesons is studied using proton-proton collisions at the LHC at a centre-of-mass energy of TeX TeV. The χ c mesons are identified through their decay to J/ψγ, with J/ψ → μ + μ − using photons that converted in the detector. A data sample, corresponding to an integrated luminosity of 1.0 fb−1 collected by the LHCb detector, is used to measure the relative prompt production rate of χ c1 and χ c2 in the rapidity range 2.0 < y < 4.5 as a function of the J/ψ transverse momentum from 3 to 20 GeV/c. First evidence for χ c0 meson production at a high-energy hadron collider is also presented.
Resumo:
OBJETIVO: Este trabalho foi realizado com o objetivo de caracterizar o detector de diamante, bem como observar seu comportamento. MATERIAIS E MÉTODOS: As características dosimétricas de feixes de fótons de 6 MV de energia foram medidas utilizando o sistema automático de varredura MP3 da PTW com um detector de diamante e foram comparadas com medidas usando uma câmara de ionização 31010 da PTW. RESULTADOS: As características dosimétricas do detector de diamante foram observadas por meio de medidas de linearidade com a dose, dependência com a taxa de dose e distribuições de dose em profundidade, bem como perfis. CONCLUSÃO: Algumas medidas com diamante e câmara de ionização foram validadas com resultados publicados na literatura, o que demonstrou um bom comportamento do detector de diamante na comparação com a câmara de ionização, muito utilizada para dosimetria em radioterapia, evidenciando que o diamante é uma boa escolha de detector para dosimetria de campos pequenos.
Resumo:
OBJETIVO: Estimar a dose extracraniana nos olhos, tireoide, tórax e pelve em pacientes submetidos a radiocirurgia com acelerador linear de 6 MV. MATERIAIS E MÉTODOS: Foram avaliados 11 pacientes com tumores cerebrais primários (7 pacientes) e secundários (4 pacientes), sendo que dois destes apresentavam duas lesões. Para a estimativa da dose extracraniana, foram utilizados dosímetros termoluminescentes. Foram utilizados cones de 1,50 a 3,75 cm e as doses de radiação variaram de 1300 a 2000 cGy. RESULTADOS: A idade média dos pacientes foi de 52 anos, sendo 63,6% do sexo feminino e 36,4% do sexo masculino. As localizações das lesões foram: nervo acústico direito (1), frontal (2), parietal (5), occipital direito (1), cerebelar (2) e parassagitais (2). Os valores médios das doses recebidas na região entre os olhos foram de 5,1 cGy; no olho direito, de 4,8 cGy; no olho esquerdo, de 6,5 cGy; na tireoide, de 4,2 cGy; no tórax, de 1,65 cGy; e na pelve, de 0,45 cGy. CONCLUSÃO: Estes resultados mostram que embora as doses não ultrapassem os limites de tolerância para ocorrência da opacidade do cristalino, é importante que os médicos radioterapeutas considerem os riscos de dose de radiação nessas regiões durante o planejamento de procedimentos de radiocirurgia craniana.
Resumo:
The construction of a tubular hydrogen ion-selective potentiometric electrode without inner reference solution, based on the tridodecylamine (TDDA) ionophore, and its evaluation in a flow system are described. TDDA was dissolved in 2-nitrophenyl octyl ether, dispersed in a PVC membrane and applied directly to a conducting support which consisted of an epoxy resin and graphite mixture. The electrode was designed with a tubular geometry to effort facilities to be coupled as part of a flow injection network. The main working characteristics such as response time, linear pH range, selectivity and life time were evaluated and compared with those obtained which a conventionally shaped electrode based on the same sensor. The electrode showed a slope of 51-52 mV dec-1 within a linear pH range from 4.0 up to 12.0.
Resumo:
Tässä diplomityössä tutkitaan erilaisia keskijänniteverkon kehittämismenetelmiä sekä suunnittelua haja-asutusalueelle. Suunnittelumetodiikan perustana on vertailla sähköverkon käyttövarmuuden tunnuslukujen sekä kokonaiskustannusten kehittymistä erilaisilla investointiratkaisuilla. Lähemmässä tarkastelussa ovat erilaiset kaapelointimenetelmät sekä automaatiolaitteet kuten maastoon sijoitettavat katkaisijat sekä kauko-ohjattavat erottimet. Kehittämisratkaisujen vertailemiseksi sähköverkosta muodostetaan laskentaa varten malli, jonka avulla on mahdollista tarkastella mm. käyttövarmuuden tunnuslukujen sekä verkon kustannusten kehittymistä. Verkon kustannuksissa otetaan huomioon investointikustannukset, käyttö- ja kunnossapitokustannukset, viankorjauskustannukset sekä keskeytyskustannukset. Keskeytysten laskentaa varten toteutetaan erilliset laskentalohkot, jotta keskeytyskustannukset saadaan mallinnettua tarkasti. Kaapelointistrategia-analyysissä vertaillaan kaapeloinnin erilaisia toteuttamisperiaatteita. Erilaisia tutkittavia kaapelointimenetelmiä ovat vyörytysmenetelmä, vikaherkimpien kohteiden uusinta, vanhimpien kohteiden uusinta, täydellinen kaapelointi sekä optimiverkostoratkaisu, jossa on hyödynnetty keskijännitejohtojen kaapeloinnin lisäksi mm. automaatioratkaisuja ja 1000 V tekniikkaa. Kaapelointimenetelmiä vertailtaessa on havaittu, että vikaherkimmistä kohteista aloitettava saneeraus tuottaa parhaimman tuloksen, jos optimiratkaisua ei oteta huomioon.
Resumo:
The results and discussions in this thesis are based on my studies about selfassembled thiol layers on gold, platinum, silver and copper surfaces. These kinds of layers are two-dimensional, one molecule thick and covalently organized at the surface. They are an easy way to modify surface properties. Self-assembly is today an intensive research field because of the promise it holds for producing new technology at nanoscale, the scale of atoms and molecules. These kinds of films have applications for example, in the fields of physics, biology, engineering, chemistry and computer science. Compared to the extensive literature concerning self-assembled monolayers (SAMs) on gold, little is known about the structure and properties of thiolbased SAMs on other metals. In this thesis I have focused on thiol layers on gold, platinum, silver and copper substrates. These studies can be regarded as a basic study of SAMs. Nevertheless, an understanding of the physical and chemical nature of SAMs allows the correlation between atomic structure and macroscopic properties. The results can be used as a starting point for many practical applications. X-ray photoelectron spectroscopy (XPS) and synchrotron radiation excited high resolution photoelectron spectroscopy (HR-XPS) together with time-offlight secondary ion mass spectrometry (ToF-SIMS) were applied to investigate thin organic films formed by the spontaneous adsorption of molecules on metal surfaces. Photoelectron spectroscopy was the main method used in these studies. In photoelectron spectroscopy, the sample is irradiated with photons and emitted photoelectrons are energy-analyzed. The obtained spectra give information about the atomic composition of the surface and about the chemical state of the detected elements. It is widely used in the study of thin layers and is a very powerful tool for this purpose. Some XPS results were complemented with ToF-SIMS measurements. It provides information on the chemical composition and molecular structure of the samples. Thiol (1-Dodecanethiol, CH3(CH2)11SH) solution was used to create SAMs on metal substrates. Uniform layers were formed on most of the studied metal surfaces. On platinum, surface aligned molecules were also detected in investigations by XPS and ToF-SIMS. The influence of radiation on the layer structure was studied, leading to the conclusion that parts of the hydrocarbon chains break off due to radiation and the rest of the layer is deformed. The results obtained showed differences depending on the substrate material. The influence of oxygen on layer formation was also studied. Thiol molecules were found to replace some of the oxygen from the metal surfaces.
Resumo:
Early repolarization, which is characterized by an elevation of the J-point on 12-lead electrocardiography, is a common finding that has been considered as benign for decades. However, in the last years, it has been related with vulnerability to idiopathic ventricular fibrillation and with cardiac mortality in the general population. Recently, 4 potential ECG predictors that could differentiate the benign from the malignant form of early repolarization have been suggested. Any previous study about early repolarization has been done in Spain. Aim. To ascertain whether the presence of early repolarization pattern in a resting electrocardiogram is associated with a major risk of cardiac death in a Spanish general population and to determine whether the presence of potential predictors of malignancy in a resting electrocardiogram increases the risk of cardiac mortality in patients with early repolarization pattern. Methods. We will analyse the presence of early repolarization and the occurrence of cardiac mortality in a retrospective cohort study of 4,279 participants aged 25 to 74 years in the province of Girona. This cohort has been followed during a mean of 9.8 years. Early repolarization will be stratified according to the degree of J-point elevation (≥0.1 mV or ≥0.2 mV), the morphology of the J-wave (slurring, notching or any of these two), the ST-segment pattern (ascending or descending) and the localization (inferior leads, lateral leads, or both). Association of early repolarization with cardiac death will be assessed by adjusted Cox-proportional hazards models