941 resultados para Log-linear model
Resumo:
The modal and nonmodal linear properties of the Hasegawa-Wakatani system are examined. This linear model for plasma drift waves is nonnormal in the sense of not having a complete set of orthogonal eigenvectors. A consequence of nonnormality is that finite-time nonmodal growth rates can be larger than modal growth rates. In this system, the nonmodal time-dependent behavior depends strongly on the adiabatic parameter and the time scale of interest. For small values of the adiabatic parameter and short time scales, the nonmodal growth rates, wave number, and phase shifts (between the density and potential fluctuations) are time dependent and differ from those obtained by normal mode analysis. On a given time scale, when the adiabatic parameter is less than a critical value, the drift waves are dominated by nonmodal effects while for values of the adiabatic parameter greater than the critical value, the behavior is that given by normal mode analysis. The critical adiabatic parameter decreases with time and modal behavior eventually dominates. The nonmodal linear properties of the Hasegawa-Wakatani system may help to explain features of the full system previously attributed to nonlinearity.
Resumo:
Substitution of fuzzy logic control in an electrical system normally controlled by proportional-integral frequency was studied and analyzed. A linear model of an electrical system, the concepts which govern the theory of fuzzy logic, and the application of this theory to systems control, are briefly presented. The methodology of fuzzy logic was then applied to develop a model for an electrical energy system. The results of the simulation demonstrated that fuzzy logic control eliminated the area frequency error and permitted that only the area experiencing an increase in charge responds to this variation. Based on the results, it is concluded that control based on fuzzy logic is simple, is easy to maintain, is of low cost, and can be used to substitute traditional velocity controllers.
Resumo:
The effect of nitrate concentration on giant river prawn, Macrobrachium rosenbergii, larvae was investigated. Survival rate, weight gain, and larval development were evaluated for different concentrations of nitrate in three experiments. The experiments were divided i n to two phases. In the first phase, larvae from stages I through VIII were analysed, while in the second phase larvae from stage VIII through post-larvae metamorphosis were analysed. Oxygen consumption was also determined for zoea I, II, and VIII exposed to 0, 700, and 1,000 mg/L of nitrate-N. No effect was observed for concentrations up to 180 mg/L NO3-N (experiments I and II), and nitrate levels as 1,000 mg/L NO3-N did not affect survival in the first phase of the third experiment. On the other hand, larval stage index (LSI) and weight gain decreased as nitrate-N concentration increased from 0 to 1,000 mg/L. In the second phase, survival and metamorphosis rate decreased as nitrate concentration increased, according to a linear model. The effect of nitrate levels on weight gain followed a curvilinear pattern. Larval respiration decreased in the water where nitrate was added, but only during stage II. The results demonstrated that nitrate presents extremely low toxicity for giant river prawn larvae, and data were related to the levels of nitrate that usually occur in larviculture systems also discussed. Therefore, nitrate is not a limiting factor for giant river prawn larviculture. © 2003 by The Haworth Press, Inc. All rights reserved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Objective: To measure 2-week postoperative sensitivity in Class II composite restorations placed with a self-etching adhesive (Clearfil SE Bond) or a total-etch adhesive (Prime&Bond NT) with or without a flowable composite as cervical increment. Method and materials: Upon approval by the University of Guarulhos Committee on Human Subjects, 100 restorations were inserted in 46 patients who required Class II restorations in their molars and premolars. Enamel and dentin walls were conditioned with a self-etching primer (for Clearfil SE Bond) or etched with 34% phosphoric acid (for Prime&Bond NT). A 1- to 2-mm-thick increment of a flowable composite (Filtek Flow) was used in the proximal box in 50% of the restorations of each adhesive. Preparations were restored with a packable composite (Surefil). The restorations were evaluated preoperatively and 2 weeks postoperatively for sensitivity to cold, air, and masticatory forces using a visual analog scale. Marginal integrity of the accessible margins was also evaluated. Statistical analysis used a mixed linear model with subject as a random effect. Results: Ninety-eight teeth from 44 subjects were observed at 2 weeks. The type of adhesive and use of flowable composite had no significant effects or interaction for any of the four outcomes of interest, ie, change from baseline to 2 weeks in sensitivity and response time for the cold or air stimulus. For the air stimulus, the overall average change from baseline was not significant for either sensitivity or response time. For the cold stimulus, the overall average change from baseline was significant for both sensitivity and response time. No case of sensitivity to masticatory forces was observed. Conclusion: No differences in postoperative sensitivity were observed between a self-etch adhesive and a total-etch adhesive at 2 weeks. The use of flowable composite did not decrease postoperative sensitivity.
Resumo:
This work deals with the effects of the series compensation on the electric power system for small-signal stability studies. Therefore, the system is modeled admitting the existence of the compensation and then, the equations are linearized and a linear model is obtained for a single machine-infinite bus power system with a compensator installed. The resulting model with nine defined constants is very similar to the Heffron & Phillips linear model widely used on the existent literature. Finally, simulations are executed for an example system, to analyze the behavior of these constants when loading the system. © 2004 IEEE.
Resumo:
Wood is generally considered an anisotropic material. In terms of engineering elastic models, wood is usually treated as an orthotropic material. This paper presents an analysis of two principal anisotropic elastic models that are usually applied to wood. The first one, the linear orthotropic model, where the material axes L (Longitudinal), R(radial) and T(tangential) are coincident with the Cartesian axes (x, y, z), is more accepted as wood elastic model. The other one, the cylindrical orthotropic model is more adequate of the growth caracteristics of wood but more mathematically complex to be adopted in practical terms. Specifically due to its importance in wood elastic parameters, this paper deals with the fiber orientation influence in these models through adequate transformation of coordinates. As a final result, some examples of the linear model, which show the variation of elastic moduli, i.e., Young's modulus and shear modulus, with fiber orientation are presented.
Resumo:
ResumoThe main idea of this work is based on the analysis of the electric torque through the acting of the PS in the power system, provided of a control for the compensation degree (PSC). A linear model of the single machine-infinite bus system is used with a PS installed (SMIB/PS system). The variable that represents the presence of PS in the net is associated to the phase displacement introduced in the terminal voltage of the synchronous machine by PS. For the input signals of the PSC are evaluated variations of the angular speed of the rotor, the current magnitude and the active power through the line where the PS is located. The simulations are accomplished to analyze the influence of the PS in the torque formation (synchronizing and damping), of the SMIB/PS system. The analysis are developed in the time and frequency domain.
Resumo:
Hearing loss and tinnitus impact the lives of workers in every instance of their lives. Aim: this paper aims to investigate the existence of a dose-response relationship between hearing loss and tinnitus by determining whether higher levels of hearing loss can be associated with increased tinnitus-related discomfort. Materials and method: this cross-sectional case study assessed 284 workers exposed to occupational noise through pure tone audiometry. Test results were categorized as defined by Merluzzi. Individuals complaining of tinnitus answered the adapted and validated Brazilian Portuguese version of the Tinnitus Handicap Inventory. A generalized linear model was adjusted for binomial data to test the interaction between these factors. Results: over 60% of the ears analyzed had hearing loss, while more than 46% of them had tinnitus. Tinnitus prevalence and risk rates increased as pure tone audiometry results got worse. The association between both, considering all hearing loss degrees, was statistically significant. Conclusion: the results point to a statistical association between hearing loss and tinnitus; the greater the hearing loss, the greater the discomfort introduced by tinnitus. 2009 © Revista Brasileira de Otorrinolaringologia.
Resumo:
Transmission expansion planning (TEP) is a non-convex optimization problem that can be solved via different heuristic algorithms. A variety of classical as well as heuristic algorithms in literature are addressed to solve TEP problem. In this paper a modified constructive heuristic algorithm (CHA) is proposed for solving such a crucial problem. Most of research papers handle TEP problem by linearization of the non-linear mathematical model while in this research TEP problem is solved via CHA using non-linear model. The proposed methodology is based upon Garver's algorithm capable of applying to a DC model. Simulation studies and tests results on the well known transmission network such as: Garver and IEEE 24-bus systems are carried out to show the significant performance as well as the effectiveness of the proposed algorithm. © 2011 IEEE.
Resumo:
This study was aimed to verify if chicks from eggs injected with ascorbic acid and subjected to thermal stress would have higher immunity than chicks from incubation at thermoneutrality without injection of ascorbic acid. The parameters evaluated were temperature on oxygen saturation in hemoglobin, glucose, number of erythrocytes, hematocrit rate and number of hemoglobins of newly hatched male chicks, hatched from eggs injected with ascorbic acid (AA) and subjected to thermal stress during incubation. The experimental design was completely randomized in factorial scheme 5 (application levels of ascorbic acid) x 2 (incubation temperatures). The data were subjected to analysis of variance using the General Linear Model procedure (GLM) of SAS ®. For the parameters (number of erythrocytes, rate of hematrocit and values of hemoglobin), there was significant interaction (p <0.05) between treatments in egg and incubation temperatures. Analyzing the interactions for these parameters, it was observed that the application of 0% ascorbic acid in egg minimized the effect of heat stress when compared with treatment without injection. The application of ascorbic acid levels in eggs incubated under heat stress failed to maximize the immunity of newly hatched chicks. It is assumed that the increased liquid in the amniotic fluid, in those embryos injected with water, favored the lower heat conductance for these embryos, thus helping in their development in relation to immunity. Considering that hemoglobin is related to the transport of gases, these data suggest that increasing the concentration of AA solution inoculated may influence the respiratory rates of eggs.
Resumo:
This study aimed to verify that chicks from eggs injected with ascorbic acid and subjected to heat stress would have changes in acid-base balance, compared to chicks incubated at thermoneutral without injection of ascorbic acid. The parameters evaluated were blood pressure of carbon dioxide and oxygen, base excess, total carbon dioxide, concentration of sodium, potassium, ionized calcium, bicarbonate and pH of newly hatched male chicks, hatched from eggs injected with acid ascorbic acid (AA) and subjected to heat stress during incubation. The experimental design was completely randomized in factorial scheme 5 (application levels of ascorbic acid) x 2 (incubation temperatures). The data were subjected to analysis of variance using the General Linear Model procedure (GLM) of SAS ®. For the blood pH was observed significant interaction (p <0.05) between treatments with application in eggs and incubation temperatures. For the other parameters were not significant effects (p< 0.05) of AA level and neither temperature of incubation. Analyzing the unfolding of the interaction to pH was observed that chicks from eggs injected with 6% ascorbic acid and subjected to heat stress during incubation had a higher pH value compared with the thermoneutral temperature incubated (p <0.05). Therefore, it is suggested that the incubation of eggs in high temperature (39°C) can alter the metabolic rate of these embryos.
Resumo:
This paper presents a mixed-integer linear programming model to solve the conductor size selection and reconductoring problem in radial distribution systems. In the proposed model, the steady-state operation of the radial distribution system is modeled through linear expressions. The use of a mixed-integer linear model guarantees convergence to optimality using existing optimization software. The proposed model and a heuristic are used to obtain the Pareto front of the conductor size selection and reconductoring problem considering two different objective functions. The results of one test system and two real distribution systems are presented in order to show the accuracy as well as the efficiency of the proposed solution technique. © 1969-2012 IEEE.
Resumo:
Objectives: The aim of this study was to compare cone beam CT (CBCT) in a small field of view (FOV) with a solid-state sensor and a photostimulable phosphor plate system for detection of cavitated approximal surfaces. Methods: 257 non-filled approximal surfaces from human permanent premolars and molars were recorded by two intraoral digital receptors, a storage phosphor plate (Digora Optime, Soredex) and a solid-state CMOS sensor (Digora Toto, Soredex), and scanned in a cone beam CT unit (3D Accuitomo FPD80, Morita) with a FOV of 4 cm and a voxel size of 0.08 mm. Image sections were carried out in the axial and mesiodistal tooth planes. Six observers recorded surface cavitation in all images. Validation of the true absence or presence of surface cavitation was performed by inspecting the surfaces under strong light with the naked eye. Differences in sensitivity, specificity and agreement were estimated by analysing the binary data in a generalized linear model using an identity link function. Results: A significantly higher sensitivity was obtained by all observers with CBCT (p,0.001), which was not compromised by a lower specificity. Therefore, a significantly higher overall agreement was obtained with CBCT (p,0.001). There were no significant differences between the Digora Optime phosphor plate system and the Digora Toto CMOS sensor for any parameter. Conclusions: CBCT was much more accurate in the detection of surface cavitation in approximal surfaces than intraoral receptors. The differences are interpreted as clinically significant. A CBCT examination performed for other reasons should also be assessed for approximal surface cavities in teeth without restorations. © 2013 The British Institute of Radiology.
Electroglottographic analysis of actresses and nonactresses' voices in different levels of intensity
Resumo:
Background: Previous studies with long-term average spectrum (LTAS) showed the importance of the glottal source for understanding the projected voices of actresses. In this study, electroglottographic (EGG) analysis was used to investigate the contribution of the glottal source to the projected voice, comparing actresses and nonactresses' voices, in different levels of intensity. Method: Thirty actresses and 30 nonactresses sustained vowels in habitual, moderate, and loud intensity levels. The EGG variables were contact quotient (CQ), closing quotient (QCQ), and opening quotient (QOQ). Other variables were sound pressure level (SPL) and fundamental frequency (F0). A KayPENTAX EGG was used. Variables were inputted in a general linear model. Results/Discussion: Actresses showed significantly higher values for SPL, in all levels, and both groups increased SPL significantly while changing from habitual to moderate and further to loud. There were no significant differences between groups for EGG quotients. There were significant differences between the levels only for F0 and CQ for both groups. Conclusion: SPL was significantly higher among actresses in all intensity levels, but in the EGG analysis, no differences were found. This apparently weak contribution of the glottal source in the supposedly projected voices of actresses, contrary to previous LTAS studies, might be because of a higher subglottal pressure or perhaps greater vocal tract contribution in SPL. Results from the present study suggest that trained subjects did not produce a significant higher SPL than untrained individuals by increasing the cost in terms of higher vocal fold collision and hence more impact stress. Future researches should explore the difference between trained and nontrained voices by aerodynamic measurements to evaluate the relationship between physiologic findings and the acoustic and EGG data. Moreover, further studies should consider both types of vocal tasks, sustained vowel and running speech, for both EGG and LTAS analysis. © 2013 The Voice Foundation.