951 resultados para Infrared Visualization
Resumo:
We report on a study of the CH3OD molecule in a search for new far-infrared (FIR) laser lines. For optical pumping of large offset vibrational absorption transitions, a continuous-wave waveguide CO2 laser with 300 MHz tunability around each line was used for the first time. As a consequence, 17. new far-infrared laser emissions were observed. For these lines, we also present data on wavelength, intensity, offset, relative polarization, and optimum operation pressure.
Resumo:
We present the results of a study on vinyl bromide for the search for new far infrared (FIR) laser lines. As the pump source, we use a CW waveguide CO2 laser with a tunability of 290 MHz around each line in order to pump large offset vibrational transitions. As a consequence, we obtained 28 new FIR laser emissions; 24 of them have wavelengths greater than 500 mum and are, therefore, suitable to be used in high-field EPR spectroscopy, For each of the new lines, we give the wavelength, the offset of the pumping transition with respect to the center Frequency of the CO2 emission, the polarization relative to that of the pumping laser line, the operating pressure, and the relative intensity. We also present a catalog including data of all of the FIR laser lines observed from this molecule up to now.
Resumo:
The purpose of the present work is to report studies on structural phase transition for PMN-xPT ferroelectric, with melt PbTiO3 composition around the MPB (x = 0.35 mol %), using infrared spectroscopy technique. The study was centered on monitoring the behavior of the 1-(NbO), 1-(TiO) and 1-(MgO) stretching modes as a function of temperature. The increasing as a function of temperature for 1-(TiO) and 1-(MgO) modes, observed between 230 and 300 K, can be related to the monoclinic (MC) + tetragonal (T) phase coexistence in the PMN-PT.
Resumo:
Infrared spectroscopy is one of the most widely used techniques for measurement of conversion degree in dental composites. However, to obtain good quality spectra and quantitative analysis from spectral data, appropriate expertise and knowledge of the technique are mandatory. This paper presents important details to use infrared spectroscopy for determination of the conversion degree.
Resumo:
The natural gas (NG) is a clean energy source and found in the underground of porous rocks, associated or not to oil. Its basic composition includes methane, ethane, propane and other components, like carbon dioxide, nitrogen, hydrogen sulphide and water. H2S is one of the natural pollutants of the natural gas. It is considered critical concerning corrosion. Its presence depends on origin, as well as of the process used in the gas treatment. It can cause problems in the tubing materials and final applications of the NG. The Agência Nacional do Petróleo sets out that the maximum concentration of H2S in the natural gas, originally national or imported, commercialized in Brazil must contain 10 -15 mg/cm3. In the Processing Units of Natural Gas, there are used different methods in the removal of H2S, for instance, adsorption towers filled with activated coal, zeolites and sulfatreat (solid, dry, granular and based on iron oxide). In this work, ion exchange resins were used as adsorbing materials. The resins were characterized by thermo gravimetric analysis, infrared spectroscopy and sweeping electronic microscopy. The adsorption tests were performed in a system linked to a gas-powered chromatograph. The present H2S in the exit of this system was monitored by a photometrical detector of pulsing flame. The electronic microscopy analyzes showed that the topography and morphology of the resins favor the adsorption process. Some characteristics were found such as, macro behavior, particles of variable sizes, spherical geometries, without the visualization of any pores in the surface. The infrared specters presented the main frequencies of vibration associated to the functional group of the amines and polymeric matrixes. When the resins are compared with sulfatreat, under the same experimental conditions, they showed a similar performance in retention times and adsorption capacities, making them competitive ones for the desulphurization process of the natural gas
Resumo:
The natural gas (NG) is a clean energy source and found in the underground of porous rocks, associated or not to oil. Its basic composition includes methane, ethane, propane and other components, like carbon dioxide, nitrogen, hydrogen sulphide and water. H2S is one of the natural pollutants of the natural gas. It is considered critical concerning corrosion. Its presence depends on origin, as well as of the process used in the gas treatment. It can cause problems in the tubing materials and final applications of the NG. The Agência Nacional do Petróleo sets out that the maximum concentration of H2S in the natural gas, originally national or imported, commercialized in Brazil must contain 10 -15 mg/cm3. In the Processing Units of Natural Gas, there are used different methods in the removal of H2S, for instance, adsorption towers filled with activated coal, zeolites and sulfatreat (solid, dry, granular and based on iron oxide). In this work, ion exchange resins were used as adsorbing materials. The resins were characterized by thermo gravimetric analysis, infrared spectroscopy and sweeping electronic microscopy. The adsorption tests were performed in a system linked to a gas-powered chromatograph. The present H2S in the exit of this system was monitored by a photometrical detector of pulsing flame. The electronic microscopy analyzes showed that the topography and morphology of the resins favor the adsorption process. Some characteristics were found such as, macro behavior, particles of variable sizes, spherical geometries, without the visualization of any pores in the surface. The infrared specters presented the main frequencies of vibration associated to the functional group of the amines and polymeric matrixes. When the resins are compared with sulfatreat, under the same experimental conditions, they showed a similar performance in retention times and adsorption capacities, making them competitive ones for the desulphurization process of the natural gas
Resumo:
The objective of this meta-analysis was to investigate the influence of meiotic spindle visualization in human oocytes on intracytoplasmic sperm injection (ICSI) outcomes. Search strategies included on-line Surveys of databases (MEDLINE, em BASE, Science Citation Index, Cochrane Controlled Trials Register and Ovid). The fixed effect was used for odds ratio. Ten trials fulfilled the inclusion criteria comparing in-vitro and clinical ICSI outcomes with or without visualization of meiotic spindle in fresh and in-vivo matured oocytes. According to the meta-analysis, the results showed statistically significant higher fertilization rate (P < 0.0001) when the meiotic spindle was viewed than when it was not. Moreover, the percentage of pro-nuclear-stage embyros with good morphology (P = 0.003), cleavage rate (P < 0.0001), percentage of day-3 top-quality embryos (P = 0.003) and percentage of embryos that reached the blastocyst stage (P < 0.0001) were statistically significantly better among, embryos derived from oocytes in which meiotic spindle was viewed compared with those in which meiotic spindle was not observed. However, these differences were not observed in the clinical pregnancy or implantation rates. This observation has clinical relevance mainly in countries where there is a legal limit on the number of oocytes to be fertilized. However, additional controlled trials are needed to further confirm these results.
Resumo:
The aim of this in vitro study was to evaluate the influence of pit and fissure sealants on fluorescence readings using lasers. We selected 166 permanent molars and randomly divided them into 4 groups which were each treated with a different sealant (a commercially available clear sealant, 2 opaque sealants and an experimental nanofilled clear sealant). The teeth were independently measured twice by 2 experienced dentists using conventional laser fluorescence (LF) and a laser fluorescence pen device (LFpen), before and after sealing, and again after thermocycling to simulate the thermal stressing between the tooth and the dental materials. Friedman test showed no statistically significant changes using LF and LFpen for the commercial clear sealant group, although values tended to increase after sealing. However, the values increased significantly after thermocycling. There was a statistically significant decrease in fluorescence after application of opaque sealants. After application of the experimental nanofilled clear sealant, LF values increased only after thermocycling, whereas the LFpen values increased after sealing and after thermocycling as well. The intraclass correlation coefficient ranged from 0.87 to 0.96 for interexaminer and 0.82 to 0.94 for intraexaminer reproducibility. It was shown that pit and fissure sealants influence LF and LFpen readings, with the values increasing or decreasing according to the material used. In conclusion, both laser fluorescence devices could be useful as an adjunct to detect occlusal caries under unfilled clear sealants. Nevertheless, surfaces sealed with clear nanofilled material could be assessed using only the LF device. Copyright (C) 2008 S. Karger AG, Basel.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Nas talassemias alfa, a HbH pode ser detectada, nos eritrócitos do sangue periférico como inclusões celulares quando coradas com azul crezil brillante. Este teste simples é útil para o diagnóstico de talassemia alfa, no entanto, a identificação dos corpos de inclusão de HbH é um processo laborioso e os resultados são altamente dependentes do observador. No intuito de melhorar a identificação das inclusões, foi testado um método alternativo para espalhar as amostras nas lâminas. Amostras de sangue foram espalhadas nas lâminas usando-se o método clássico e o método alternativo. O método alternativo permitiu uma melhor identificação das inclusões de HbH do que o método clássico. Nossos resultados mostraram que o método alternativo é uma opção útil para a pesquisa dos corpúsculos de inclusão de HbH naquelas amostras onde o método clássico não o permite.
Resumo:
The analysis of large amounts of data is better performed by humans when represented in a graphical format. Therefore, a new research area called the Visual Data Mining is being developed endeavoring to use the number crunching power of computers to prepare data for visualization, allied to the ability of humans to interpret data presented graphically.This work presents the results of applying a visual data mining tool, called FastMapDB to detect the behavioral pattern exhibited by a dataset of clinical information about hemoglobinopathies known as thalassemia. FastMapDB is a visual data mining tool that get tabular data stored in a relational database such as dates, numbers and texts, and by considering them as points in a multidimensional space, maps them to a three-dimensional space. The intuitive three-dimensional representation of objects enables a data analyst to see the behavior of the characteristics from abnormal forms of hemoglobin, highlighting the differences when compared to data from a group without alteration.