896 resultados para Impulsive controls


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The stratotype section for the base of the Miocene is at a reversed (below) to normal (above) magnetic transition that is claimed to represent magnetic chron C6Cn.2n (o). Deep Sea Drilling Project (DSDP) Site 522 is the only location we are aware of that unambiguously records the three normal events of C6Cn. We have quantitatively determined the range of the short-lived nannofossil Sphenolithus delphix and the lower limit of S. disbelemnos in DSDP Holes 522 and 522A in order to calibrate their precise relationship to the magnetostratigraphy and to confirm the completeness of the record at this site. Astronomical tuning of Ocean Drilling Program (ODP) Sites 926, 928, and 929 shows that S. disbelemnos appears at 22.67 Ma and that the entire range of S. delphix is from about 22.98 Ma to 23.24 Ma. Using these ages, linear interpolation in DSDP Site 522 suggests that the age of C6Cn.2n (o) and of the Oligocene-Miocene boundary is 22.92+/-0.04 Ma. Our value, conservatively expressed as 22.9+/-0.1 Ma, is 0.9 m.y. younger than the currently accepted age of the Oligocene-Miocene boundary and of C6Cn.2n (o), which was assigned an age of 23.8 Ma, based on an estimate of 23.8+/-1 Ma for the Oligocene-Miocene boundary. The bulk-sediment carbon isotope data from DSDP Site 522 is correlated to the record from benthic foraminifera at ODP Site 929 to refine the calibration of magnetic reversals from C6Cn.1n (o) to C7n.2n (o) at DSDP Site 522 on the astronomical time scale.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Exhumed faults hosting hydrothermal systems provide direct insight into relationships between faulting and fluid flow, which in turn are valuable for making hydrogeological predictions in blind settings. The Grimsel Breccia Fault (Aar massif, Central Swiss Alps) is a late Neogene, exhumed dextral strike-slip fault with a maximum displacement of 25–45 m, and is associated with both fossil and active hydrothermal circulation. We mapped the fault system and modelled it in three dimensions, using the distinctive hydrothermal mineralisation as well as active thermal fluid discharge (the highest elevation documented in the Alps) to reveal the structural controls on fluid pathway extent and morphology. With progressive uplift and cooling, brittle deformation inherited the mylonitic shear zone network at Grimsel Pass; preconditioning fault geometry into segmented brittle reactivations of ductile shear zones and brittle inter-shear zone linkages. We describe ‘pipe’-like, vertically oriented fluid pathways: (1) within brittle fault linkage zones and (2) through alongstrike- restricted segments of formerly ductile shear zones reactivated by brittle deformation. In both cases, low-permeability mylonitic shear zones that escaped brittle reactivation provide important hydraulic seals. These observations show that fluid flow along brittle fault planes is not planar, but rather highly channelised into sub-vertical flow domains, with important implications for the exploration and exploitation of geothermal energy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A set of problems concerning the behaviour of a suddenly disturbed ideal floating zone is considered. Mathematical techniques of asymptotic expansions arc used to solve these problems. It is seen that many already available solutions, most of them concerning liquids enclosed in cavities, will be regarded as starting approximations which are valid except in the proximity of the free surface which laterally bounds the floating zone. In particular, the problem of the linear spin-up of an initially cylindrical floating zone is considered in some detail. The presence of a recircuiating fluid pattern near the free surface is detected. This configuration is attributed to the interplay between Coriolis forces and the azimuthal component of the viscous forces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The geochemical fingerprint of sediment retrieved from the banks of the River Manzanares as it passes through the City of Madrid is presented here. The river collects the effluent water from several Waste Water Treatment (WWT) plants in and around the city, such that, at low flows, up to 60% of the flow has been treated. A total of 18 bank-sediment cores were collected along the course of the river, down to its confluence with the Jarama river, to the south–east of Madrid. Trace and major elements in each sample were extracted following a double protocol: (a) “Total” digestion with HNO3, HClO4 and HF; (b) “Weak” digestion with sodium acetate buffered to pH=5 with acetic acid, under constant stirring. The digests thus obtained were subsequently analysed by ICP-AES, except for Hg which was extracted with aqua regia and sodium chloride-hydroxylamine sulfate, and analysed by Cold Vapour-AAS. X-ray diffraction was additionally employed to determine the mineralogical composition of the samples. Uni- and multivariate analyses of the chemical data reveal the influence of Madrid on the geochemistry of Manzanares' sediments, clearly manifested by a marked increase in the concentration of typically “urban” elements Ag, Cr, Cu, Pb and Zn, downstream of the intersection of the river with the city's perimeter. The highest concentrations of these elements appear to be associated with illegal or accidental dumping of waste materials, and with the uncontrolled incorporation of untreated urban runoff to the river. The natural matrix of the sediment is characterised by fairly constant concentrations of Ce, La and Y, whereas changes in the lithology intersected by the river cause corresponding variations in Ca–Mg and Al–Na contents. In the final stretch of the river, the presence of carbonate materials seems to exert a strong geochemical control on the amount of Zn and, to a lesser extent, Cu immobilised in the sediments. This fact suggests that a variable but significant proportion of both elements may be susceptible to reincorporation in the aqueous phase under realistic environmental conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High switching frequencies (several MHz) allow the integration of low power DC/DC converters. Although, in theory, a high switching frequency would make possible to implement a conventional Voltage Mode control (VMC) or Peak Current Mode control (PCMC) with very high bandwidth, in practice, parasitic effects and robustness limits the applicability of these control techniques. This paper compares VMC and CMC techniques with the V2IC control. This control is based on two loops. The fast internal loop has information of the output capacitor current and the error voltage, providing fast dynamic response under load and voltage reference steps, while the slow external voltage loop provides accurate steady state regulation. This paper shows the fast dynamic response of the V2IC control under load and output voltage reference steps and its robustness operating with additional output capacitors added by the customer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ripple-based controls can strongly reduce the required output capacitance in PowerSoC converter thanks to a very fast dynamic response. Unfortunately, these controls are prone to sub-harmonic oscillations and several parameters affect the stability of these systems. This paper derives and validates a simulation-based modeling and stability analysis of a closed-loop V 2Ic control applied to a 5 MHz Buck converter using discrete modeling and Floquet theory to predict stability. This allows the derivation of sensitivity analysis to design robust systems. The work is extended to different V 2 architectures using the same methodology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The problem of optimal impulsive collision avoidance between two colliding objects in 3-dimensional elliptical Keplerian orbits is investigated with the purpose of establishing the optimal impulse direction and orbit location that give rise to the maximum miss distance following the maneuver. Closed-form analytical expressions are provided that predicts such distance and can be employed to perform a full optimization analysis. After verifying the accuracy of the expression for any orbital eccentricity and encounter geometry the optimum maneuver direction is derived as a function of the arc length separation between the maneuver point and the predicted collision point. The provided formulas can be used for high accuracy instantaneous estimation of the outcome of a generic impulsive collision avoidance maneuver and its optimization

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three components of carbon allocation, biomass, flux, and partitioning, were measured in two contrasting Amazon forests growing under similar climatic conditions. Allocation to aboveground compartments was highest in a high-stature forest growing on clay soils, while allocation to fine roots was higher in a short-stature forest growing on white sands. Differences in carbon allocation components where not proportional between the two forests, with soils controlling a trade-off between allocation to fine roots versus aboveground parts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The design and development of a new method for performing fracture toughness tests under impulsive loadings using explosives is presented. The experimental set-up was complemented with pressure transducers and strain gauges in order to measure, respectively, the blast wave that reached the specimen and the loading history. Fracture toughness tests on a 7017-T73 aluminium alloy were carried out by using this device under impulsive loadings. Previous studies reported that such aluminium alloy had very little strain rate sensitivity, which made it an ideal candidate for comparison at different loading rates. The fracture-initiation toughness values of the 7017-T73 aluminium alloy obtained at impulsive loadings did not exhibit a significant variation from the cases studied at lower loading rates. Therefore, the method and device developed for measuring the dynamic fracture-initiation toughness under impulsive loadings was considered suitable for such a purpose

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La electrónica digital moderna presenta un desafío a los diseñadores de sistemas de potencia. El creciente alto rendimiento de microprocesadores, FPGAs y ASICs necesitan sistemas de alimentación que cumplan con requirimientos dinámicos y estáticos muy estrictos. Específicamente, estas alimentaciones son convertidores DC-DC de baja tensión y alta corriente que necesitan ser diseñados para tener un pequeño rizado de tensión y una pequeña desviación de tensión de salida bajo transitorios de carga de una alta pendiente. Además, dependiendo de la aplicación, se necesita cumplir con otros requerimientos tal y como proveer a la carga con ”Escalado dinámico de tensión”, donde el convertidor necesitar cambiar su tensión de salida tan rápidamente posible sin sobreoscilaciones, o ”Posicionado Adaptativo de la Tensión” donde la tensión de salida se reduce ligeramente cuanto más grande sea la potencia de salida. Por supuesto, desde el punto de vista de la industria, las figuras de mérito de estos convertidores son el coste, la eficiencia y el tamaño/peso. Idealmente, la industria necesita un convertidor que es más barato, más eficiente, más pequeño y que aún así cumpla con los requerimienos dinámicos de la aplicación. En este contexto, varios enfoques para mejorar la figuras de mérito de estos convertidores se han seguido por la industria y la academia tales como mejorar la topología del convertidor, mejorar la tecnología de semiconducores y mejorar el control. En efecto, el control es una parte fundamental en estas aplicaciones ya que un control muy rápido hace que sea más fácil que una determinada topología cumpla con los estrictos requerimientos dinámicos y, consecuentemente, le da al diseñador un margen de libertar más amplio para mejorar el coste, la eficiencia y/o el tamaño del sistema de potencia. En esta tesis, se investiga cómo diseñar e implementar controles muy rápidos para el convertidor tipo Buck. En esta tesis se demuestra que medir la tensión de salida es todo lo que se necesita para lograr una respuesta casi óptima y se propone una guía de diseño unificada para controles que sólo miden la tensión de salida Luego, para asegurar robustez en controles muy rápidos, se proponen un modelado y un análisis de estabilidad muy precisos de convertidores DC-DC que tienen en cuenta circuitería para sensado y elementos parásitos críticos. También, usando este modelado, se propone una algoritmo de optimización que tiene en cuenta las tolerancias de los componentes y sensados distorsionados. Us ando este algoritmo, se comparan controles muy rápidos del estado del arte y su capacidad para lograr una rápida respuesta dinámica se posiciona según el condensador de salida utilizado. Además, se propone una técnica para mejorar la respuesta dinámica de los controladores. Todas las propuestas se han corroborado por extensas simulaciones y prototipos experimentales. Con todo, esta tesis sirve como una metodología para ingenieros para diseñar e implementar controles rápidos y robustos de convertidores tipo Buck. ABSTRACT Modern digital electronics present a challenge to designers of power systems. The increasingly high-performance of microprocessors, FPGAs (Field Programmable Gate Array) and ASICs (Application-Specific Integrated Circuit) require power supplies to comply with very demanding static and dynamic requirements. Specifically, these power supplies are low-voltage/high-current DC-DC converters that need to be designed to exhibit low voltage ripple and low voltage deviation under high slew-rate load transients. Additionally, depending on the application, other requirements need to be met such as to provide to the load ”Dynamic Voltage Scaling” (DVS), where the converter needs to change the output voltage as fast as possible without underdamping, or ”Adaptive Voltage Positioning” (AVP) where the output voltage is slightly reduced the greater the output power. Of course, from the point of view of the industry, the figures of merit of these converters are the cost, efficiency and size/weight. Ideally, the industry needs a converter that is cheaper, more efficient, smaller and that can still meet the dynamic requirements of the application. In this context, several approaches to improve the figures of merit of these power supplies are followed in the industry and academia such as improving the topology of the converter, improving the semiconductor technology and improving the control. Indeed, the control is a fundamental part in these applications as a very fast control makes it easier for the topology to comply with the strict dynamic requirements and, consequently, gives the designer a larger margin of freedom to improve the cost, efficiency and/or size of the power supply. In this thesis, how to design and implement very fast controls for the Buck converter is investigated. This thesis proves that sensing the output voltage is all that is needed to achieve an almost time-optimal response and a unified design guideline for controls that only sense the output voltage is proposed. Then, in order to assure robustness in very fast controls, a very accurate modeling and stability analysis of DC-DC converters is proposed that takes into account sensing networks and critical parasitic elements. Also, using this modeling approach, an optimization algorithm that takes into account tolerances of components and distorted measurements is proposed. With the use of the algorithm, very fast analog controls of the state-of-the-art are compared and their capabilities to achieve a fast dynamic response are positioned de pending on the output capacitor. Additionally, a technique to improve the dynamic response of controllers is also proposed. All the proposals are corroborated by extensive simulations and experimental prototypes. Overall, this thesis serves as a methodology for engineers to design and implement fast and robust controls for Buck-type converters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

V2Ic control provides very fast dynamic performance to the Buck converter both under load steps and under voltage reference steps. However, the design of this control is complex since it is prone to subharmonic oscillations and several parameters affect the stability of the system. This paper derives and validates a very accurate modeling and stability analysis of a closed-loop V2Ic control using the Floquet theory. This allows the derivation of sensitivity analysis to design a robust converter. The proposed methodology is validated on a 5-MHz Buck converter. The work is also extended to V2 control using the same methodology, showing high accuracy and robustness. The paper also demonstrates, on the V2 control, that even a low bandwidth-linear controller can affect the stability of a ripple-based control.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Exposure of cells to protein tyrosine phosphatase (PTP) inhibitors causes an increase in the phosphotyrosine content of many cellular proteins. However, the level at which the primary signaling event is affected is still unclear. We show that Jaks are activated by tyrosine phosphorylation in cells that are briefly exposed to the PTP inhibitor pervanadate (PV), resulting in tyrosine phosphorylation and functional activation of Stat6 (in addition to other Stats). Mutant cell lines that lack Jak1 activity fail to support PV-mediated [or interleukin 4 (IL-4)-dependent] activation of Stat6 but can be rescued by complementation with functional Jak1. The docking sites for both Jak1 and Stat6 reside in the cytoplasmic domain of the IL-4 receptor α-chain (IL-4Rα). The glioblastoma-derived cell lines T98G, GRE, and M007, which do not express the IL-4Rα chain, fail to support Stat6 activation in response to either IL-4 or PV. Complementation of T98G cells with the IL-4Rα restores both PV-mediated and IL-4-dependent Stat6 activation. Murine L929 cells, which do not express the γ common chain of the IL-4 receptor, support PV-mediated but not IL-4-dependent Stat6 activation. Thus, Stat6 activation by PV is an IL-4Rα-mediated, Jak1-dependent event that is independent of receptor dimerization. We propose that receptor-associated constitutive PTP activity functions to down-regulate persistent, receptor-linked kinase activity. Inhibition or deletion of PTP activity results in constitutive activation of cytokine signaling pathways.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Open Access funded by Parkinson's UK Financial support: This study was funded by Parkinson’s UK, the Scottish Chief Scientist Office, NHS Grampian endowments, the BMA Doris Hillier award, RS Macdonald Trust, the BUPA Foundation, and SPRING. The funders had no involvement in the study. We acknowledge funding for the PINE study from Parkinson’s UK (G-0502, G-0914 G-1302), the Scottish Chief Scientist Office (CAF/12/05), the BMA Doris Hillier award, RS Macdonald Trust, the BUPA Foundation, NHS Grampian endowments and SPRING. We thank the patients and controls for their participation and the research staff who collected data and supported the study database.