921 resultados para Immediate loading
Resumo:
The skin is constantly exposed to commensal microflora and pathogenic microbes. The stratum corneum of the outermost skin layer employs distinct tools such as harsh growth conditions and numerous antimicrobial peptides (AMPs) to discriminate between beneficial cutaneous microflora and harmful bacteria. How the skin deals with microbes that have gained access to the live part of the skin as a result of microinjuries is ill defined. In this study, we report that the chemokine CXCL14 is a broad-spectrum AMP with killing activity for cutaneous gram-positive bacteria and Candida albicans as well as the gram-negative enterobacterium Escherichia coli. Based on two separate bacteria-killing assays, CXCL14 compares favorably with other tested AMPs, including human beta-defensin and the chemokine CCL20. Increased salt concentrations and skin-typical pH conditions did not abrogate its AMP function. This novel AMP is highly abundant in the epidermis and dermis of healthy human skin but is down-modulated under conditions of inflammation and disease. We propose that CXCL14 fights bacteria at the earliest stage of infection, well before the establishment of inflammation, and thus fulfills a unique role in antimicrobial immunity.
Resumo:
PURPOSE: The aim of this prospective case series study was to evaluate the short-term success rates of titanium screw-type implants with a chemically modified sand-blasted and acid-etched (mod SLA) surface after 3 weeks of healing. MATERIAL AND METHODS: A total of 56 implants were inserted in the posterior mandible of 40 partially edentulous patients exhibiting bone densities of class I to III. After a healing period of 3 weeks, all implants were functionally loaded with a screw-retained crown or fixed dental prosthesis. The patients were recalled at weeks 4, 7, 12, and 26 for monitoring and assessment of clinical and radiological parameters, including implant stability quotient (ISQ) measurements. RESULTS: None of the implants failed to integrate. However, two implants were considered "spinners" at day 21 and left unloaded for an extended period. Therefore, 96.4% of the inserted implants were loaded according to the protocol tested. All 56 implants including the "spinners" showed favorable clinical and radiographic findings at the 6-month follow-up examination. The ISQ values increased steadily throughout the follow-up period. At the time of implant placement, the range of ISQ values exhibited a mean of 74.33, and by week 26, a mean value of 83.82 was recorded. Based on strict criteria, all 56 implants were considered successfully integrated, resulting in a 6-month survival and success rate of 100.0%. CONCLUSION: This prospective study using an early-loading protocol after 3 weeks of healing demonstrated that titanium implants with the modified SLA surface can achieve and maintain successful tissue integration over a period of at least 6 months. The ISQ method seems feasible to monitor implant stability during the initial wound-healing period.
Resumo:
AIM: To assess dimensional ridge alterations following immediate implant placement in molar extraction sites. MATERIAL AND METHODS: Twelve subjects received 12 immediate transmucosal implants in molar extraction sites. Peri-implant defects were treated according to the principles of Guided Bone Regeneration by means of a deproteinized bone substitute and a bioresorbable collagen membrane. Changes in vertical (IS-BD, CREST-BD) and horizontal distances (EC-I, IC-I) of alveolar bony walls to the bottom of the defects (BD) and to the implant surfaces (I) were compared between implant placement and surgical re-entry at 6 months. RESULTS: The implant survival rate at 6 months was 100%. Statistically significant differences (P<0.01) were observed in the mean changes in vertical distances IS-BD and CREST-BD between baseline and re-entry. At re-entry, all peri-implant marginal defects assessed from the internal socket wall to the implant surface (IC-I) were healed. The residual combined thickness of the buccal wall with the newly formed peri-implant bone at sites with an initial thickness of 1 mm was statistically significantly smaller (P<0.05) compared with that of sites with an initial buccal thickness of 2 mm (2.50 +/- 0.76 vs. 4+/-0 mm). CONCLUSIONS: The marginal defects around immediate implants placed in molar extraction sites were completely filled after 6 months of healing through de novo bone formation. Bone resorption was observed from the external aspects of the buccal and oral socket walls. Dimensional changes of the external socket walls were mostly pronounced at the buccal aspects.
Resumo:
AIM: To assess soft tissues healing at immediate transmucosal implants placed into molar extraction sites with buccal self-contained dehiscences. MATERIAL AND METHODS: For this 12-month controlled clinical trial, 15 subjects received immediate transmucosal tapered-effect (TE) implants placed in molar extraction sockets displaying a buccal bone dehiscence (test sites) with a height and a width of > or =3 mm, respectively. Peri-implant marginal defects were treated according to the principles of Guided Bone Regeneration (GBR) by means of deproteinized bovine bone mineral particles in conjunction with a bioresorbable collagen membrane. Fifteen subjects received implants in healed molar sites (control sites) with intact buccal alveolar walls following tooth extraction. In total, 30 TE implants with an endosseous diameter of 4.8 mm and a shoulder diameter of 6.5 mm were used. Flaps were repositioned and sutured, allowing non-submerged, transmucosal soft tissues healing. At the 12-month follow-up, pocket probing depths (PPD) and clinical attachment levels (CAL) were compared between implants placed in the test and the control sites, respectively. RESULTS: All subjects completed the 12-month follow-up period. All implants healed uneventfully, yielding a survival rate of 100%. After 12 months, statistically significantly higher (P<0.05) PPD and CAL values were recorded around implants placed in the test sites compared with those placed in the control sites. CONCLUSIONS: The findings of this controlled clinical trial showed that healing following immediate transmucosal implant installation in molar extraction sites with wide and shallow buccal dehiscences yielded less favorable outcomes compared with those of implants placed in healed sites, and resulted in lack of 'complete' osseointegration.
Resumo:
Clinical application of ozone gas has been shown to arrest the progression of dentinal caries in children. In this study, we compare the immediate effects of gaseous ozone and chlorhexidine gel on bacteria in cavitated carious lesions in children. Forty children, each with at least two open occlusal carious lesions, were enrolled in the study. Two teeth were chosen randomly. In one lesion, overlying soft biological material was removed, whilst the other lesion was not excavated. Cavities were rinsed with sterile water and dried with air. A standardised sample was taken from the mesial part of each lesion. Then, gaseous ozone (HealOzone) or 1% chlorhexidine gel (Corsodyl) was applied for 30 s on both lesions of 20 children each, and a second sample was taken from the distal part of each lesion. The anaerobic microbiota was cultivated; the number of colony forming units was calculated per milligram sample. The two-sided paired t test showed no significant (P > 0.05) differences in the reduction of total bacterial counts per milligram comparing samples before and after ozone or chlorhexidine application. The tests also showed no statistically significant difference whether the superficial decayed dentine had been removed before ozone or with chlorhexidine treatment or not. It can be concluded that gaseous ozone or chlorhexidine gel application for 30 s to deep occlusal carious cavities had no significant immediate antimicrobial effects whether the superficial decayed layers dentine were removed or not.
Resumo:
Diagnosis of drug allergy involves first the recognition of sometimes unusual symptoms as drug allergy and, second, the identification of the eliciting drug. This is an often difficult task, as the clinical picture and underlying pathomechanisms are heterogeneous. In clinical routine, physicians frequently have to rely upon a suggestive history and eventual provocation tests, both having their specific limitations. For this reason both in vivo (skin tests) and in vitro tests are investigated intensively as tools to identify the disease-eliciting drug. One of the tests evaluated in drug allergy is the basophil activation test (BAT). Basophils with their high-affinity IgE receptors are easily accessible and therefore can be used as indicator cells for IgE-mediated reactions. Upon allergen challenge and cross-linking of membrane-bound IgE antibodies (via Fc-epsilon-RI) basophils up-regulate certain activation markers on their surface such as CD63 and CD203c, as well as intracellular markers (eg, phosphorylated p38MAPK). In BAT, these alterations can be detected rapidly on a single-cell basis by multicolor flow cytometry using specific monoclonal antibodies. Combining this technique with in vitro passive sensitization of donor basophils with patients' serum, one can prove the IgE dependence of a drug reaction. This article summarizes the authors' current experience with the BAT in the diagnostic management of immediate-type drug allergy mediated by drug-specific IgE antibodies.
Resumo:
The aim of this research was to study the impact of loading on partial dentures within the supporting soft tissue with respect to different attachment techniques. A finite element model was developed to calculate the stress and strain distribution in this tissue. The model consisted of the left half of a mandible with three remaining teeth that had suffered an atrophy in the anterior region, and a partial denture over the toothless area that was connected at the left mandibular canine using an attachment system. Resulting stress/strain distributions are presented for different load cases using a commercially available prefabricated attachment system.
Resumo:
OBJECTIVE: The paper aims to define the parameters available before surgery which could predict immediate facial nerve function after excision of a vestibular schwannoma (VS). METHODS: Ninety-nine patients with VS operated consecutively by a single surgeon using an identical surgical technique have been evaluated retrospectively. Data were collected regarding patients' sex, age at onset of symptoms and at surgery, initial symptoms, neurological status at presentation, early post-operative neurological status and complications. The main radiological parameters included in the study were tumour extension pattern, diameters, shape, and volume, as well as extent of bony changes of the internal auditory canal. RESULTS: As the tumour stage and volume increase, facial nerve function is worse after surgery (p < 0.001 and p < 0.05, respectively). Concomitantly, larger extra-meatal tumour diameters in three dimensions (sagittal, coronal and axial) led to worse function (p < 0.01). Anterior and/or caudal tumour extension (p = 0.001 and p = 0.004, respectively) had more significant correlation than posterior and/or cranial extension (p = 0.022 and p = 0.353, respectively). Polycyclic VS had the worst prognosis, followed by the tumours with oval shape. The extent of intra-meatal tumour growth does not correlate with immediate facial nerve outcome. The different angles, lengths and diameters of the internal auditory channel showed no significant correlation with facial nerve outcome. Patients with headache as an initial symptom and those with gait instability and/or pre-operative poor facial nerve function had significantly worse immediate facial nerve outcome. CONCLUSION: Our data suggests that the analysis of the radiological and neurological patient data prior to surgery could give reliable clues regarding the immediate post-operative facial nerve function.
Resumo:
The calciuric response after an oral calcium load (1000 mg elemental calcium together with a standard breakfast) was studied in 13 healthy male controls and 21 recurrent idiopathic renal calcium stone formers, 12 with hypercalciuria (UCa x V > 7.50 mmol/24 h) and nine with normocalciuria. In controls, serum 1,25(OH)2 vitamin D3 (calcitriol) remained unchanged 6 h after oral calcium load (50.6 +/- 5.1 versus 50.9 +/- 5.0 pg/ml), whereas it tended to increase in hypercalciuric (from 53.6 +/- 3.2 to 60.6 +/- 5.4 pg/ml, P = 0.182) and fell in normocalciuric stone formers (from 45.9 +/- 2.6 to 38.1 +/- 3.3 pg/ml, P = 0.011). The total amount of urinary calcium excreted after OCL was 2.50 +/- 0.20 mmol in controls, 2.27 +/- 0.27 mmol in normocalciuric and 3.62 +/- 0.32 mmol in hypercalciuric stone formers (P = 0.005 versus controls and normocalciuric stone formers respectively); it positively correlated with serum calcitriol 6 h after calcium load (r = 0.392, P = 0.024). Maximum increase in urinary calcium excretion rate, delta Ca-Emax, was inversely related to intact PTH levels in the first 4 h after calcium load, i.e. more pronounced PTH suppression predicted a steeper increase in urinary calcium excretion rate. Twenty-four-hour urine calcium excretion rate was inversely related to the ratio of delta calcitriol/deltaPTHmax after calcium load (r = -0.653, P = 0.0001), indicating that an abnormally up-regulated synthesis of calcitriol and consecutive relative PTH suppression induce hypercalciuria.(ABSTRACT TRUNCATED AT 250 WORDS)
Resumo:
OBJECTIVES To evaluate the stabilizing function of atlanto-axial ligaments in dogs. STUDY DESIGN Cadaveric biomechanical study. ANIMALS Beagle dog cadavers (n = 10). METHODS The craniocervical region was collected from 10 Beagle cadavers, and the occipito-atlanto-axial region was prepared and freed from the surrounding muscles. Care was taken to preserve integrity of the atlantoaxial ligaments and atlantoaxial joint capsule. The atlanto-occipital joints were blocked with 2 diverging transarticular 1.8 mm positive threaded K-wires. Specimen extremities were embedded in polymethylmethacrylate (PMMA) and mounted on a simulator testing shear load at the atlantoaxial joint. Range of motion (ROM) and neutral zone (NZ) were determined with all ligaments intact, after cutting the apical ligament, both alar ligaments, the transverse ligaments and finally after cutting the dorsal atlantoaxial ligament. RESULTS ROM increased similarly and stepwise during testing. The most significant increase was observed after transection of the alar ligaments. CONCLUSION The alar ligaments seem to be the most important ligamentous structures for stabilization of the atlantoaxial joint under shear load.