988 resultados para Imaging system
Resumo:
PURPOSE The purpose of this study was to describe autofluorescence lifetime characteristics in Stargardt disease (STGD) using fluorescence lifetime imaging ophthalmoscopy (FLIO) and to investigate potential prognostic markers for disease activity and progression. METHODS Fluorescence lifetime data of 16 patients with STGD (mean age, 40 years; range, 22-56 years) and 15 age-matched controls were acquired using a fluorescence lifetime imaging ophthalmoscope based on a Heidelberg Engineering Spectralis system. Autofluorescence was excited with a 473-nm laser, and decay times were measured in a short (498-560 nm) and long (560-720 nm) spectral channel. Clinical features, autofluorescence lifetimes and intensity, and corresponding optical coherence tomography images were analyzed. One-year follow-up examination was performed in eight STGD patients. Acquired data were correlated with in vitro measured decay times of all-trans retinal and N-retinylidene-N-retinylethanolamine. RESULTS Patients with STGD displayed characteristic autofluorescence lifetimes within yellow flecks (446 ps) compared with 297 ps in unaffected areas. In 15% of the STGD eyes, some flecks showed very short fluorescence lifetimes (242 ps). Atrophic areas were characterized by long lifetimes (474 ps), with some remaining areas of normal to short lifetimes (322 ps) toward the macular center. CONCLUSIONS Patients with recent disease onset showed flecks with very short autofluorescence lifetimes, which is possible evidence of accumulation of retinoids deriving from the visual cycle. During the study period, many of these flecks changed to longer lifetimes, possibly due to accumulation of lipofuscin. Therefore, FLIO might serve as a useful tool for monitoring of disease progression. (ClinicalTrials.gov number, NCT01981148.).
Resumo:
Io's plasma and neutral tori play significant roles in the Jovian magnetosphere. We present feasibility studies of measuring low-energy energetic neutral atoms (LENAs) generated from the Io tori. We calculate the LENA flux between 10 eV and 3 keV. The energy range includes the corotational plasma flow energy. The expected differential flux at Ganymede distance is typically 10(3)-10(5) cm(-2) s(-1) sr(-1) eV(-1) near the energy of the corotation. It is above the detection level of the planned LENA sensor that is to be flown to the Jupiter system with integration times of 0.01-1 s. The flux has strong asymmetry with respective to the Io phase. The observations will exhibit periodicities, which can be attributed to the Jovian magnetosphere rotation and the rotation of Io around Jupiter. The energy spectra will exhibit dispersion signatures, because of the non-negligible flight time of the LENAs from Io to the satellite. In 2030, the Jupiter exploration mission JUICE will conduct a LENA measurement with a LENA instrument, the Jovian Neutrals Analyzer (JNA). From the LENA observations collected by JNA, we will be able to derive characteristic quantities, such as the density, velocity, velocity distribution function, and composition of plasma-torus particles. We also discuss the possible physics to be explored by JNA in addition to the constraints for operating the sensor and analyzing the obtained dataset. (C) 2015 Elsevier Ltd. All rights reserved.
Resumo:
BACKGROUND: Bioluminescence imaging is widely used for cell-based assays and animal imaging studies, both in biomedical research and drug development. Its main advantages include its high-throughput applicability, affordability, high sensitivity, operational simplicity, and quantitative outputs. In malaria research, bioluminescence has been used for drug discovery in vivo and in vitro, exploring host-pathogen interactions, and studying multiple aspects of Plasmodium biology. While the number of fluorescent proteins available for imaging has undergone a great expansion over the last two decades, enabling simultaneous visualization of multiple molecular and cellular events, expansion of available luciferases has lagged behind. The most widely used bioluminescent probe in malaria research is the Photinus pyralis firefly luciferase, followed by the more recently introduced Click-beetle and Renilla luciferases. Ultra-sensitive imaging of Plasmodium at low parasite densities has not been previously achieved. With the purpose of overcoming these challenges, a Plasmodium berghei line expressing the novel ultra-bright luciferase enzyme NanoLuc, called PbNLuc has been generated, and is presented in this work. RESULTS: NanoLuc shows at least 150 times brighter signal than firefly luciferase in vitro, allowing single parasite detection in mosquito, liver, and sexual and asexual blood stages. As a proof-of-concept, the PbNLuc parasites were used to image parasite development in the mosquito, liver and blood stages of infection, and to specifically explore parasite liver stage egress, and pre-patency period in vivo. CONCLUSIONS: PbNLuc is a suitable parasite line for sensitive imaging of the entire Plasmodium life cycle. Its sensitivity makes it a promising line to be used as a reference for drug candidate testing, as well as the characterization of mutant parasites to explore the function of parasite proteins, host-parasite interactions, and the better understanding of Plasmodium biology. Since the substrate requirements of NanoLuc are different from those of firefly luciferase, dual bioluminescence imaging for the simultaneous characterization of two lines, or two separate biological processes, is possible, as demonstrated in this work.
Resumo:
We have developed an empirically based simulation system to create images equivalent in SNR and SPR to those that would be acquired with various possible SEDR configurations. This system uses a collection of spot collimated full-field images (SCFFIs) of an anthropomorphic chest phantom, taken at high exposure levels and rescaled in noise and intensity, then digitally collimated and combined to produce the simulated SEDR images. This system allows for the study of design trade-offs between different equalization feedback schemes and scatter rejection geometries in addition to estimating the clinical benefits of SEDR over traditional imaging techniques. Data from this simulation system has demonstrated that SEDR techniques offer potential significant improvements over currently used digital radiography techniques for chest imaging. ^
Resumo:
The oceans play a critical role in the Earth's climate, but unfortunately, the extent of this role is only partially understood. One major obstacle is the difficulty associated with making high-quality, globally distributed observations, a feat that is nearly impossible using only ships and other ocean-based platforms. The data collected by satellite-borne ocean color instruments, however, provide environmental scientists a synoptic look at the productivity and variability of the Earth's oceans and atmosphere, respectively, on high-resolution temporal and spatial scales. Three such instruments, the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) onboard ORBIMAGE's OrbView-2 satellite, and two Moderate Resolution Imaging Spectroradiometers (MODIS) onboard the National Aeronautic and Space Administration's (NASA) Terra and Aqua satellites, have been in continuous operation since September 1997, February 2000, and June 2002, respectively. To facilitate the assembly of a suitably accurate data set for climate research, members of the NASA Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) Project and SeaWiFS Project Offices devote significant attention to the calibration and validation of these and other ocean color instruments. This article briefly presents results from the SIMBIOS and SeaWiFS Project Office's (SSPO) satellite ocean color validation activities and describes the SeaWiFS Bio-optical Archive and Storage System (SeaBASS), a state-of-the-art system for archiving, cataloging, and distributing the in situ data used in these activities.