864 resultados para Illinois. Energy Efficiency Trust Fund Program.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The castor bean crop (Ricinus communis L.) has acquired prestige due to industries interest in the oil quality and recently for new sources of energy demand. The experiment that served as basis for the data used in this study was conducted at the Lageado Experimental Farm, in Botucatu - SP, 2008. This study aimed to avaluate the crop viability through energy balance and energy efficiency since the implantation until biodiesel production using parameters of consumption in operational management for installation and maintenance of culture harvest and oil production. The soil management operations, sow and harvest consumed the total of 266.20 MJ ha(-1), gathering with the fertilizers, pesticides, fuels, lubricants, labor, seed and industrial processing totaled 56,808 MJ ha(-1) of energy inputs. The energy production was 72,814.00 MJ ha(-1). The industry still lacks studies thal would contribution data collection and more specific energy coefficients. The castor beans cultivation was considered efficient allowing again of 15983.44 MJ ha(-1) equivalent to about 415 liters of diesel oil.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Foi avaliado o desempenho energético da suinocultura integrada à produção de milho em grão em sistema de plantio direto mecanizado. Nesta concepção de integração proposta, os dejetos suínos são utilizados como fertilizantes na produção de milho. O sistema foi delimitado envolvendo as atividades associadas ao manejo dos suínos e de produção do milho (manejo do solo, cultivo e colheita). O período de análise considerado foi de um ano, o que possibilita a produção de três lotes de suínos e duas safras de milho. Para avaliar o desempenho energético, foram criados três indicadores: eficiência energética, eficiência de uso de fontes não renováveis e o custo de energia não renovável para a produção de proteína. As entradas energéticas são compostas pelos insumos e pela infraestrutura, utilizados na criação dos suínos e na produção de milho, e pela radiação solar incidente no agrossistema. Já as saídas são representadas pelos seus produtos (suínos terminados e o milho). Os resultados obtidos nas simulações apontam que a integração melhora o desempenho energético das granjas suinícolas, aumentando a eficiência energética (186%) e a eficiência não renovável (352%), além de reduzir o custo de energia não renovável para a produção de proteína (‑58%).
Resumo:
The efficiency of energy transfer (ET) between Pr3+ ions in a fluoroindate glass is determined. ET rates, WET, were determined for dilute samples and the results show a dependence of WET on the Pr3+ concentration. ET processes which contribute to resonance fluorescence and frequency upconversion emission were studied. The origin of the interaction energy among the Pr3+ ions was determined to be dipole - dipole. © 1998 Elsevier Science B.V. All rights reserved.
Resumo:
It was evaluated the energetic efficiency and operational parameters of a windrowing and prismatic baling, both from CASE NEW HOLLAND® operations in sugarcane vegetal residues (green leaves, dry leaves and tops) picked mechanically in green cane. The area belongs to COSTA PINTO MILL (COSAN® Group) which was harvested mechanically by combines in the State of Sao Paulo, Brazil. The geographic location of the area is: Latitude 22°40'30S, Longitude 47°36'38W and Altitude of 605m. The variety was RB 82-5336, planted in 1.40m row spacing, with 78t.ha-1 yield. The vegetal residues analysis obtained 69.93% of leaves, 21.44% of stalks fractions, 2.27% of tops and 6.36% of total strange matter. The vegetal residues values were: gross heat of 18.43MJ.kg-1, low heat of 17.00MJ.kg'1 and useful heat of 12.94MJ.kg-1. The vegetal residues average energetic potential was 342.48GJ.ha-1. The treatments were simple, double and triple windrowing. The use of the rake and prismatic baler to pick up the residues was viable. The simple windrowing treatment presented the best results: effective capacity of 83.06t.ha-1, fuel consumption of 0.18L.t -1 and 99.95% of positive energetic efficiency. The bales obtained in the treatment of triple windrowing presented the largest specific mass average of 221.11kg.m-3. The soil amount in the bales increased with successive windrowing. The baling operation in the triple windrowing treatment obtained better results, presenting the effective capacities of 20.29t.h -1 and 1.45ha.h-1 and fuel consumption of for baled in 1.37L.t-1. The high total energetic efficiency of 99.53% indicates that is technically viable the withdrawal of the vegetal residues.
Resumo:
The objective of this study was to analyze the sugar cane vegetal residues collection, as well as determining its energetic potential, using a rake and cylindrical baler, both from NEW HOLLAND® under two different windrowing process (simple and double). The field tests were carried out in an area that belongs to COSTA PINTO MILL (COSAN® Group) in the city of Piracicaba, Sao Paulo State, Brazil. The geographic location of the area is: Latitude 22°4030'S, Longitude 47°3633'W and altitude of 605m. From the trash analysis, before the baling, the following average results were obtained: 69.93% of leaves; 2.27% of stalks fractions; 21.44% of tops and 6.36% of total strange matter. The estimated residues yield was 27.01 tons.ha -1 with a gross heat of 18.43 MJ.kg-1, low heat of 17.01 MJ.kg-1, useful heat of 13.32 MJ.kg-1, average moisture of 20.76% and an energetic potential of 494,875.09 MJ.ha-1. In the windrowing operations (simple and double) the averages of the 5 out of 13 analyzed variable presented differences between them in a 1% level of significance in the Tukey Test. The averages comparison of the results for bale's specific mass and the effective capacities (ton.h-1) e (ha.h-1) had been significant at a 5% level in the Tukey Test. The comparisons of the averages for the results had been significant to 1% level. The strange matter averages of the bales did not differed between them.
Resumo:
The sugar cane crop according to several authors can generate, besides the industrialized stalks, an amount of crop residues from the order of 15 to 30% in weight of the aerial part of the plants, depending on the field conditions. The sugar cane area in Brazil is around 5.5×106 hectares, with an amount of 400.106 tons of stalks, with stalks yield of 72 tons.ha-1 (Unica, 2005). This study took place in a sugar cane plot (Latitude 22°46'S, Longitude 47°23'W and 600m of altitude) with 3% of slope, located in São Paulo State. The sugar cane variety was SP 80-1816, in its forth cut, 11 months old and with a planted row spacing of 1.40m. By other side, several sugar mills are bringing the crop residue to their patio to produce energy with the bagasse. One way for that is the baling operation to bring the crop residue at the sugar mill. Some fundamental variables were obtained to define the best set of machines to work with in sugar cane crop residue removal in the baling system among the studied ones, some of the variables were: Soil Index (T1 = 0.83%, T2 = 0.46%, T3 = 0.65%, T4 = 0.57%); Energy Efficiency (T1 = 82.48%, T2 = 83.88%, T3 = 82.83% and T4 = 82.97%) of the system and Effective Cost for Equivalent Energy in US$.EBP-1 (T1 = 11.10, T2= 10.46, T3 = 11.47 and T4 = 10.57) of the baled trash delivered at the sugar mill.
Resumo:
Includes bibliography
Resumo:
Includes bibliography
Resumo:
Includes bibliography
Resumo:
The traditional operational and hazard control paradigm of an electrical installation has several issues pertaining to the diversity of equipment. A large maintenance inventory is a reason for concern for any manager, but the arc flash hazard is a particularly new phenomenon and the effects of equipment diversity on this phenomenon are even newer. The class of arc hazard can be increased, simply by changing the fuse link or circuit breaker manufacturer. Management pressure to operate as well as non-standard practices and installations are also partly responsible. The aim of this study is to take a typical situation in an industrial plant and to statistically simulate, by means of a dedicated software program, the fuse arc flash interruption performance of various manufacturers. The purpose of this study is to obtain a more objective indication of the influence of different fuse link manufacturers on arc flash incident energy. © 2011 IEEE.
Resumo:
The traditional operational and hazard control paradigm of an electrical installation has several issues pertaining to the diversity of equipment. A large maintenance inventory is a reason for concern for any manager, but the arc-flash hazard is a particularly new phenomenon, and the effects of equipment diversity on this phenomenon are even newer. The class of arc hazard can be simply increased by changing the fuse link or circuit breaker manufacturer. Management pressure to operate as well as nonstandard practices and installations are also partly responsible. The aim of this article is to take a typical situation in an industrial plant and to statistically simulate, by means of a dedicated software program, the fuse arc-flash interruption performance of various manufacturers. The purpose of this article is to obtain a more objective indication of the influence of different fuse link manufacturers on arc-flash incident energy. © 1975-2012 IEEE.
Resumo:
Brazil is the world's largest producer of sugar cane and which in the state of São Paulo concentrate the greatest amount of sugar cane field of the country. The sugar-alcohol sector has the capacity to produce sufficient thermal and electrical energy to be used in their process of production and commercialize of surplus in electricity distribution network. Therefore it is necessary to evaluate the energy efficiency and rationality within the mill. Accordingly this research proposed analyze the sugar-alcohol mill's sectors globally and individually, located in the west center of the São Paulo state, using the valuation methodology employed by the Agência Nacional de Energia Elétrica (ANEEL) in the industries that do not have systems of cogeneration. In this analysis, the hyperboloids of load and potency were applied based on the indexes of potency factor and load factor that allow estimate the efficiency and rationality. © 2013 IEEE.
Resumo:
Pós-graduação em Engenharia Elétrica - FEB