980 resultados para Hudson


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Genome-wide association studies (GWASs) have been successful at identifying single-nucleotide polymorphisms (SNPs) highly associated with common traits; however, a great deal of the heritable variation associated with common traits remains unaccounted for within the genome. Genome-wide complex trait analysis (GCTA) is a statistical method that applies a linear mixed model to estimate phenotypic variance of complex traits explained by genome-wide SNPs, including those not associated with the trait in a GWAS. We applied GCTA to 8 cohorts containing 7096 case and 19 455 control individuals of European ancestry in order to examine the missing heritability present in Parkinson's disease (PD). We meta-analyzed our initial results to produce robust heritability estimates for PD types across cohorts. Our results identify 27% (95% CI 17-38, P = 8.08E - 08) phenotypic variance associated with all types of PD, 15% (95% CI -0.2 to 33, P = 0.09) phenotypic variance associated with early-onset PD and 31% (95% CI 17-44, P = 1.34E - 05) phenotypic variance associated with late-onset PD. This is a substantial increase from the genetic variance identified by top GWAS hits alone (between 3 and 5%) and indicates there are substantially more risk loci to be identified. Our results suggest that although GWASs are a useful tool in identifying the most common variants associated with complex disease, a great deal of common variants of small effect remain to be discovered. © Published by Oxford University Press 2012.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We performed a genome-wide association study (GWAS) in 1705 Parkinson's disease (PD) UK patients and 5175 UK controls, the largest sample size so far for a PD GWAS. Replication was attempted in an additional cohort of 1039 French PD cases and 1984 controls for the 27 regions showing the strongest evidence of association (P < 10 4). We replicated published associations in the 4q22/SNCA and 17q21/MAPT chromosome regions (P < 10 10) and found evidence for an additional independent association in 4q22/SNCA.A detailed analysis of the haplotype structure at 17q21 showed that there are three separate risk groups within this region. We found weak but consistent evidence of association for common variants located in three previously published associated regions (4p15/BST1, 4p16/GAK and 1q32/PARK16). We found no support for the previously reported SNP association in 12q12/LRRK2. We also found an association of the two SNPs in 4q22/SNCA with the age of onset of the disease. © The Author 2010. Published by Oxford University Press.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Chlamydia pneumoniae is an obligate intracellular bacterium implicated in a wide range of human diseases including atherosclerosis and Alzheimer's disease. Efforts to understand the relationships between C. pneumoniae detected in these diseases have been hindered by the availability of sequence data for non-respiratory strains. In this study, we sequenced the whole genomes for C. pneumoniae isolates from atherosclerosis and Alzheimer's disease, and compared these to previously published C. pneumoniae genomes. Phylogenetic analyses of these new C. pneumoniae strains indicate two sub-groups within human C. pneumoniae, and suggest that both recombination and mutation events have driven the evolution of human C. pneumoniae. Further fine-detailed analyses of these new C. pneumoniae sequences show several genetically variable loci. This suggests that similar strains of C. pneumoniae are found in the brain, lungs and cardiovascular system and that only minor genetic differences may contribute to the adaptation of particular strains in human disease.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In Australia, factors such as local planning processes, urban encroachment into rural areas and intensification of the poultry industry have increased the potential for odour and dust nuisance. At present, accurate estimates of odour emissions from mechanically ventilated poultry housing systems do not exist for Australian conditions. This has made the poultry industry vulnerable to unsubstantiated criticism. Recently, the Australian poultry industry have made a significant investment in research to obtain accurate estimates of odour, dust and volatile chemical emission rates from typical poultry housing systems. This paper describes the measurement of odour emissions from tunnel ventilated poultry housing systems in different climatic zones in Queensland and Victoria, Australia (humid sub-tropical and Mediterranean respectively) during two seasons (summer and winter). Samples were collected at defined intervals over typical batch production cycles to define the odour emission profiles. These samples were analysed using dynamic olfactometry according to the Australian Standard 4323.3 to derive the odour concentration values. Ventilation rates were measured concurrently, allowing the calculation of odour emission rates. Odour concentration and emission rates were assessed in terms of ventilation rate, ambient and shed air temperature and relative humidity and litter moisture status. Odour emission rates varied with bird age. Seasonal differences in odour emission rate were also observed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Continuous odour monitoring technologies are necessary to understand the complex odour-generating mechanisms within poultry housing as well as to identify strategies to reduce the impact of odour emissions on local communities. To evaluate electronic nose (EN) technologies for continuously assessing odour concentration in poultry housing, a mobile laboratory containing an electronic nose and an associated sample delivery system was deployed to a commercial poultry farm and tested over a broiler production cycle. The results demonstrated that it was possible to develop a model to allow an electronic nose to provide a semi-continuous measurement of odour concentrations. The electronic nose was also able to demonstrate the influence of shed conditions on odour emissions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universities and teacher employment bodies seek new, cost-effective ways for graduating classroom-ready teachers. This study involved 32 final-year preservice teachers in an innovative school-university partnership teacher education program titled, the School-Community Integrated Learning (SCIL) pathway. Data were collected using a five-part Likert scale survey with extended written responses. Survey results showed that preservice teachers involved in the SCIL pathway learnt more about the teaching profession, which extended their usual university coursework. Furthermore, written responses suggested ways for advancing their understandings to ensure preservice teachers receive a quality school experience towards readiness for teaching.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The selection of an odour sampling device may influence the composition of the resulting odour sample. Limited comparison of emission rates derived from turbulent and essentially quiescent sampling devices confirms that the emission rates derived from these devices are quite different. There is therefore compelling evidence that current odour sampling practice should have greater regard for fundamental physical and chemical principles, the nature of the odour source and the conditions created by the sampling device. Such consideration may identify the most appropriate situations under which the use of these devices may or may not be correct.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sampling devices differing greatly in shape, size and operating condition have been used to collect air samples to determine rates of emission of volatile substances, including odour. However, physical chemistry principles, in particular the partitioning of volatile substances between two phases as explained by Henrys Law and the relationship between wind velocity and emission rate, suggests that different devices cannot be expected to provide equivalent emission rate estimates. Thus several problems are associated with the use of static and dynamic emission chambers, but the more turbulent devices such as wind tunnels do not appear to be subject to these problems. In general, the ability to relate emission rate estimates obtained from wind tunnel measurements to those derived from device-independent techniques supports the use of wind tunnels to determine emission rates that can be used as input data for dispersion models.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Three anaerobic ponds used to store and treat piggery wastes were fully covered with permeable materials manufactured from polypropylene geofabric, polyethylene shade cloth and supported straw. The covers were assessed in terms of efficacy in reducing odour emission rates over a 40-month period. Odour samples were collected from the surface of the covers, the surface of the exposed liquor and from the surface of an uncovered (control) pond at one of the piggeries. Relative to the emission rate of the exposed liquor at each pond, the polypropylene, shade cloth and straw covers reduced average emission rates by 76%, 69% and 66%, respectively. At the piggery with an uncovered control pond, the polypropylene covers reduced average odour emission rates by 50% and 41%, respectively. A plausible hypothesis, consistent with likely mechanisms for the odour reduction and the olfactometric method used to quantifying the efficacy of the covers, is offered.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two commonly used sampling devices (a wind tunnel and the US EPA dynamic emission chamber), were used to collect paired samples of odorous air from a number of agricultural odour sources. The odour samples were assessed using triangular, forced-choice dynamic olfactometry. The odour concentration data was combined with the flushing rate data to calculate odour emission rates for both devices on all sources. Odour concentrations were consistently higher in samples collected with a flux chamber (ratio ranging from 10:7 to 5:1, relative to wind tunnel samples), whereas odour emission rates were consistently larger when derived from wind tunnels (ratio ranging from 60:1 to 240:1, relative to flux chamber values). A complex relationship existed between emission rate estimates derived from each device, apparently influenced by the nature of the emitting surface. These results have great significance for users of odour dispersion models, for which an odour emission rate is a key input parameter.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Odour emission rates were measured for seven different anaerobic ponds treating piggery wastes at six to nine discrete locations across the surface of each pond on each sampling occasion over a thirteen month period. Significant variability in emission rates were observed for each pond. Measurement of a number of water quality variables in pond liquor samples collected at the same time and from the same locations as the odour samples indicated that the composition of the pond liquor was also variable. The results indicated that spatial variability was a real phenomenon and could have a significant impact on odour assessment practices. Considerably more odour samples would be required to characterise pond emissions than currently recommended by most practitioners, or regulatory agencies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Odour emission rates were measured for seven different anaerobic ponds treating piggery wastes at six to nine discrete locations across the surface of each pond on each sampling occasion over a 14-month period. Emission rate values varied between ponds, between seasons for the same pond and even for the same pond on different days of a sampling week. Average seasonal emission rates ranged from 7.9 to 46.5 OU/m2 s, while average emission rates ranged from 16.0 to 29.0 OU/m2 s. Factors potentially responsible for the variability in emission rates were investigated, including air and pond liquor temperatures, time of day of sample collection, season and the impact of a prolonged drought.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A variety of materials were trialed as supported permeable covers using a series of laboratory-scale anaerobic digesters. Efficacy of cover performance was assessed in terms of impact on odour and greenhouse gas emission rate, and the characteristics of anaerobic liquor. Data were collected over a 12-month period. Initially the covers reduced the rate of odour emission 40-100 times relative to uncovered digesters. After about three months, this decreased to about a threefold reduction in odour emission rate, which was maintained over the remainder of the trial. The covers did not alter methane emission rates. Carbon dioxide emission rates varied according to cover type. Performance of the covers was attributed to the physical characteristics of the cover materials and changes in liquor composition. The reductions in odour emission indicate that these covers offer a cost-effective method for odour control.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The efficacy of supported covers was investigated under field conditions using a series of prototypes deployed on an anaerobic pond treating typical piggery waste. Research focused on identifying effective cover support materials and deployment methods, quantifying odour reduction, and estimating the life expectancy of various permeable cover materials. Over a 10-month period, median odour emission rates were five to eight times lower from supported straw cover surfaces and a non-woven, spun fibre polypropylene weed control material than from the adjacent uncovered pond surface. While the straw covers visually appeared to degrade very rapidly, they continued to reduce odour emissions effectively. The polypropylene cover appeared to offer advantages from the perspectives of cost, reduced maintenance and ease of manufacture.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A commercial non-specific gas sensor array system was evaluated in terms of its capability to monitor the odour abatement performance of a biofiltration system developed for treating emissions from a commercial piggery building. The biofiltration system was a modular system comprising an inlet ducting system, humidifier and closed-bed biofilter. It also included a gravimetric moisture monitoring and water application system for precise control of moisture content of an organic woodchip medium. Principal component analysis (PCA) of the sensor array measurements indicated that the biofilter outlet air was significantly different to both inlet air of the system and post-humidifier air. Data pre-processing techniques including normalising and outlier handling were applied to improve the odour discrimination performance of the non-specific gas sensor array. To develop an odour quantification model using the sensor array responses of the non-specific sensor array, PCA regression, artificial neural network (ANN) and partial least squares (PLS) modelling techniques were applied. The correlation coefficient (r(2)) values of the PCA, ANN, and PLS models were 0.44, 0.62 and 0.79, respectively.