531 resultados para Ferrita de cobalto-manganês


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEIS

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Snakes from Bothrops genus are responsible for more than 90% of the ophidian accidents in Brazil. One of the main complications from this kind of accident is muscular necrosis, which is related to the action of phospholipases A2 and metalloproteases, two groups of enzymes found in the venom of these animals. Although this complication cannot be solved by serum therapy administration, a great number of studies have been performed with the attempt to know the pharmacological sites of these toxins aiming, in the future, the development of complementary treatments to serum therapy. This work proposes structural studies of bothropic phospholipases A2 (PLA2s) in the presence of ions relevant to their activity, using the X-ray crystallography technique. Recently, it was demonstrated ions, as manganese, calcium and others, interfere in the biological activity of the PLA2s. Particularly, Lys49-PLA2s in the presence of manganese ions have miotoxicity reduced. Asp49-PLA2s show catalytic activity dependent of calcium, although structural studies with a miotoxic Asp49-PLA2, BthTX-II, suggest a possible catalytic mechanism independent of calcium. Therefore, co-crystallization of BthTX-II in the presence of calcium ions and of PrTX-I in the presence of manganese ions were performed. Comparative structural studies among obtained results and others already published in the literature were performed aiming a better understanding of the structure-function relationship of these toxins. The BthTX-II with the presence of calcium do not show this ion in the loop of coordination of calcium, presence necessary to develop the catalyses. After comparison of this model with the native one, only one distortion was found, but no apparent relationship with the residues responsible for its activity. In the PrTX-I structure, regions candidates of manganese ions were also found... (Complete abstract click electronic access below)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AC Biosusceptometry (ACB) is a low-cost biomagnetic tool that has been successfully applied on pharmaceutical research to evaluate performance of solid dosage forms. The aim of this work was to evaluate the Horn & Shunck method to access tablet disintegration. To evaluate the HS results was record on video a test with a objet moving in a rail with a constant velocity. The desintegration was recorded on video and ACB, which used have seven pairs of detection coils and a pair of excitation coils to mensure the magnetic ux variation. The signals were ampli ed and digitalized to create images, which were restored by Wiener lter, while the video images are converted to gray scale, both are normalized and binarized and had the optical ow estimation calculated by Horn & Schunck (HS) algorithm. All signals and images are processed and developed algorithm on Matlab. During the tests the ve tablets (500mg ferrite, 375mg excipients, compression 10 to 50 kN) were on a becker between of the ACB system and of the video system, and only touching the surface of the water. With all OF maps calculated was realized the sum of the resultants of each, to get a disintegration process resultant for each compression. Whit that was possible observed the disintegration behaves. For the compression force study the HS components of each sequence was sum, take mean and normalized for sequence's max modulo, therefore can be observed a high growing on less compression tablets. We can conclude the HS algorithm is viable to tablets disintegration data collection and whit that was possible to create a tablets disintegration analyzes protocol, which would be useful on desintegration kinetics study

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Um bloco de poliuretano recebeu três implantes de hexagono externo, no posicionamento compensado. Para cada implante foi conectado o pilar protético microunit. Foram realizados cinco enceramentos com três coifas plásticas cada um, que foram fundidos em monobloco numa liga de cobalto-cromo. Foram colados quatro extensomêtros tangenciando cada implante, sendo dois extensomêtros para o implante central. Após o acabamento, as estruturas foram fixadas nos respectivos locais com o parafuso de retenção com torque de 10 Ncm, obtidos com um torquímetro. Para aplicação de carga sobre os corpos-de-prova foram selecionados cinco pontos de aplicação de carga. O dispositivo de aplicação de carga–DAC foi utilizado 30 kg de cargas verticais estáticas, empregando uma ponta esférica de 2 mm de diamêtro, durante 10 segundos em cada um dos pontos estabelecidos, sendo, neste instante registradas as micro deformações de cada extensômetro. Foi utilizado o teste de análise de variância T Student e o nível de significância foi o valor convencional de 5%. Para cada implante foi analisada a microdeformação ocorrida. Os resultados obtidos mostraram que houve uma diferença estatisticamente significativa entre os pontos não-axiais D e E (t = 5,21 df = 4, p = 0,006 < 0,05) e não foi estatisticamente significativa para os dados axial entre os pontos B e C (t = 6, 57, df = 4, p = 0,003 < 0,05 / 3). Conclui-se que,a aplicação de carga ao redor de três implantes de hexágono externo no posicionamento compensado,mostra que os pontos não-axiais sofrem maior micro deformação do que os pontos axiais

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this experiment was evaluate the effect of the bioestimulant administered in grafted and non-grafted japanese cucumber (Cucumis sativus L.) plants, under greenhouse conditions, in gas exchanges during the development of the plant and in the increase of yield. The experiment was carried out in the experimental area of Agronomic Sciences University of UNESP, Campus of Botucatu, São Paulo State, Brazil. The experiment design was completely randomized, in a factorial arrangement of 2x5, grafted and non-grafted plants and 5 treatments with bioestimulant: control, indolbutyric acid 0,0005% + citocinine 0,0009% + gibberelic acid 0,005% 250 mL ha-1; indolbutyric acid 0,0005% + citocinine 0,0009% + gibberelic acid 0,005% 375 mL ha-1; indolbutyric acid 0,0005% + citocinine 0,0009% + gibberelic acid 0,005% 500 mL ha-1; Yuca extract (Yucca elephantipes) + manganese + iron + copper + sulfur 375 mL ha-1 applied 15 days after the transplant, in intervals of 7 days between the applications, via leaf. The effect of the treatments were evaluated through the observations of the following characteristics: production of fruits (number and mass), average mass of the fruit and measures of gas exchanges. It can be concluded that indolbutyric acid 0,0005% + citocinine 0,0009% + gibberelic acid 0,005% 250 mL ha-1 increased CO2 assimilation rate and the water efficiency, influencing in addition to increase the quantity of the fruits

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Biosusceptometry AC (BAC) is a research tool that has been extensively explored by the group Biomagnetism IBB-UNESP for monitoring of the gastrointestinal tract, its response to a known drug or in vivo performance of solid dosage forms. During this period the BAC, which has the characteristics of high sensitivity and low cost, has been developed primarily for recording signals contraction of activity and traffic human gastrointestinal tract. With the possibility of producing images with this instrumentation, it was possible to evaluate different situations in vitro and in vivo for physiological studies and pharmaceuticals. Considering the good performance of this system to produce planar images, the first aim of the BAC system tomography (TBAC) was to evaluate the system performance of BAC to produce tomographic images of phantoms ferromagnetic for a single channel system. All these applications were only possible because of their sensitivity to materials of high magnetic suscepitibility as ferrite, which allow to produce an electrical signal proportional to the variation of the magnetic flux generated by the presence of magnetic marker next to a first-order gradiometer. Measuring this variation at various points was possible to generate planar images that recently came to be produced in systems with multiple detectors, said multi-channels. From planar images, also producing tomographic images of simulators BAC bars in a system of 13 channels using only the center channel, with good results when applied to simple objects as one and two bars. When testing the resolution of the system with more elaborate forms the quality and resolution of images reconstructed is not satisfactory, which would be solved by increasing the spatial sampling rate and hence the acquisition time. The present system works with an acquisition time of about five hours. Whereas this system will be applied for in vivo experiments, the acquisition time became a ...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O câncer é uma patologia crescente entre a população atual e segundo a Organização Mundial da Saúde (OMS) está entre as principais causa de morte mundialmente. A relevância do perfil epidemiológico dessa doença desperta interesse em desenvolver materiais que forneçam qualidade de diagnóstico e tratamento. Na busca pela qualidade da saúde, o desenvolvimento de materiais que possam liberar fármacos de forma controlada e em um sítio alvo, tem se tornado cada vez mais intensa, pois estes materiais podem diminuir os efeitos colaterais além de aumentar a porcentagem do medicamento em ação direta com o sítio alvo. Neste contexto, materiais poliméricos híbridos orgânico-inorgânicos do tipo ureasil-poliéter que são biocompatíveis, transparentes e flexíveis permitem a incorporação de uma série de compostos, dentre os quais, nanopartículas e fármacos. Com base nestes argumentos, neste trabalho foi desenvolvido dispositivo de liberação controlada de fármacos formado por materiais poliméricos ureasil-poliéter contendo nanopartículas de ZnO dopadas com cobalto. A conjugação destes diferentes materiais teve como objetivo conferir as propriedades individuais de cada componente no mesmo material: o cobalto devido as suas propriedades magnéticas pode guiar o dispositivo de liberação de fármaco até o órgão doente; o ZnO devido às propriedades luminescentes permite monitorar a posição do dispositivo dentro do corpo humano.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The studies of this work aimed to determine the labile fractions of manganese (Mn) in natural and drainage water samples collected around the Osamu Utsumi uranium mine, located in the municipality of Caldas, south-central region of Poços de Caldas- MG, using the technique of diffusion gradient in thin films (DGT). The DGT devices were mounted with Chelex-100 resin, polyacrylamide-agarose hydrogel (conventional porosity) and cellulose acetate membrane. The device were deployed up to 48 hours in six water samples collected from different areas around the uranium mine (075, 076, 022-E, 025-E, 014, and 041). The DGT devices immersed in each sample were gradually removed after 4, 8, 12, 24 and 48 hours. The pH of the samples ranged from 3.0 to 10.5, which influenced the lability and the sampling of the analyte by the Chelex-100 resin. The results showed a linear relationship between accumulated mass and sampling time (immersion curve) for samples 014 and 025-E (pH between 6 and 8) suggesting the ability of the DGT technique for sampling the analyte. The results obtained for samples 075 and 076 (pH<5) and samples 041 and 022-E (pH around 10) were characterized by nonlinear relationships. The values obtained by DGT were compared with Solid Phase Extraction (SPE) technique using Chelex-100. For samples 014 and 025-E, there was a good agreement between the results obtained by both techniques

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The study of mechanical properties of high-alloy special steels is of great interest of the steel industry due to the great demand by companies that manufacture automotive components of high criticality, and also because of its high commercial value. However, the development of this type of alloy metals demand highly technical knowledge. Among these extremely important kinds of steel, the subject which is the interest of this study is the special steel modified by niobium. The manganese and niobium are the main alloying elements in the composition of these steels, both of them increase the stability of the austenite region, however, manganese increases the hardenability and tensile yield strength, and niobium increases the mechanical strength and promotes refining the grain. The mechanical characterization of steel SAE 1312 modified the niobium was made in order to gain a better understanding of the influence on the mechanical properties caused by aging at different temperatures and for different reductions in the drawing of gauge material. This characterization was made by means of tensile test and hardness. This material showed an increase in yield strength and hardness when gauge with large reductions during the wiredrawing, but when subjected to aging temperatures higher than 300 ° C had a slight loss of these properties

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The gastrointestinal tract is the main route of nutrients absorption and drugs delivery. Is important to know the parameters related to the tract, like gastric emptying and gastrointestinal transit, in order to better understand the behavior of different kind of meals or drugs passing through the GIT. Many techniques are used to study these parameters, such as manometry, scintigraphy, phenol red, activated charcoal and carbon-13 reading. However, these methods use radiation, are invasive and require animal sacrifice. As an alternative proposal, the Alternate Current Biosusceptometry (ACB), a magnetic technique, has proved to be effective for these studies with small animals, in a noninvasive way, low cost, radiation free and avoiding the animal death. Associating the ACB to magnetic micro or nanoparticles used as tracers, it is possible to observe the meal behavior inside of the GIT. Focusing meanly on liquid meals digestion, this paper had the objective to evaluate the efficiency of the ACB technique in gastric emptying and gastrointestinal transit evaluation of liquid meals in rats. To perform the experiments, magnetic nanoparticles (ferrite, MgFe2O4) were used on a 1,5 ml solution introduced by gavage on similar weight and age rats. The sensor made by 2 pairs of coils, capable of generating and detecting magnetic fields, creates a field on the interest place and when this field is in contact with the marked meal, it changes, resulting on a variation of the measured voltage. The voltage variation is analyzed and is obtained a particle concentration on the interest region. The results showed that is possible to apply the ACB technique on the GIT evaluation of liquid particles digestion, gastric emptying and meal cecum arrival time curves were obtained and from that, is possible to observe a pattern of gastrointestinal transit. Both mean process time values were acquired, proving the technique capability of ...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this in vitro study was quantify the micro strain development around the internal hexagon implants, varying the type of prosthetic coping. For This reason, three implants of internal hexagon were inserted into one polyurethane block in line placement. Microunit abutments were screwed onto the implants. Tangentially the implants were bonded the strain gauges, two to the center implant. Ten structures, each one containing three copings were cast in Co-Cr alloy, that were divided into groups in the first group, plastic copings were used, and in the second group machined copings were used. The superstructure’s occlusal screws were tightened onto Microunit abutments with 10 Ncm torque, the magnitude of micro strain was recorded. The mean values of each strain gauge of each plastic copings were 363,37 ± 237,66 and the machined copings were 338,12 ± 223,01. The data were analyzed statistically by t- Student test. No statistically significant difference was found between the prosthetic copings (p= 0,867). It was concluded that to internal hexagon implants in line placement, the type of copings presented similar magnitude of micro strain after prosthetic occlusal screw was tightened