827 resultados para Femoral shaft Fractures


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The most widely accepted treatment for comminuted fractures of the radial head is either the excision or open reduction and internal fixation. The purpose of the present study is to evaluate the value of an 'on-table' reconstruction technique in severely comminuted fractures of the radial head. In this study, two patients with a Mason type-III and four patients with a Mason type-IV radial-head fracture were treated with 'on-table' reconstruction and fixation using low-profile mini-plates. After a mean follow-up of 112 months (47-154 months), the mean elbow motion was 0-6-141 degrees extension flexion with 79 degrees of pronation and 70 degrees of supination. The mean Broberg and Morrey functional rating score was 97.0 points, the Mayo Elbow Performance Index was 99.2 points and the mean Disabilities of the Arm, Shoulder, and Hand (DASH) Outcome Measure score was 1.94 points. One patient had symptoms of degenerative changes, with a slight joint-space narrowing. There were no radiographic signs of devitalisation at final examination. Comminuted fractures of the radial head, which would otherwise require excision, can be successfully treated with an 'on-table' reconstruction technique.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Residual acetabular dysplasia of the hip in most patients can be corrected by periacetabular osteotomy. However, some patients have intraarticular abnormalities causing insufficient coverage, containment or congruency after periacetabular osteotomy, or extraarticular abnormalities that limit either acetabular correction or hip motion. For these patients, we believe an additional proximal femoral osteotomy can improve coverage, containment, congruency and/or motion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: The treatment of paediatric fractures is the concern of several different surgical specialties. There has been no scientific investigation on the different concepts of paediatric (PS) and adult surgeons (AS). METHODS: 62 paediatric traumatologists were asked concerning their experience with physeal fractures of the leg, including ten cases. RESULTS: Growth disturbances was estimated to be more rare by PS. On evaluation of the examples there were no significant differences in the judgement of degree and direction of the displacement. For displaced fractures, PS rather preferred closed reduction and immobilisation, whereas AS favoured osteosynthesis. DISCUSSION: There were no basic differences between PS and AS in the treatment of lower limb fractures. AS tend to act more invasively. At the same time they are more concerned about growth disturbances.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Proximal humerus fractures (pHF) are common. In this retrospective study intra-operative and postoperative data and complications of patients stabilized with conventional semirigid techniques (pins, n=30; helix wire, n=19) or a novel semirigid technique, the intramedullary claw (IMC, n=82) were compared. The type and frequency of postoperative complications differed between the groups (p<0.001). The IMC is a novel semirigid technique to stabilize pHF and seems to result in fewer complications than pins or helix wire. The frequency and relevance of a loss of repositioning in patients after IMC implantation need to be elucidated in long-term studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Therapy of metacarpal neck fractures depending on radiographically measured palmar angulation is discussed controversially in the literature. Some authors describe normal hand function of malunited metacarpal neck fractures with a palmar angulation up to 70°; others define 30° as the uppermost limit to maintain normal hand function. However, the methods of measuring palmar angulation are not clearly defined. Here, we present a new method to measure palmar angulation using ultrasound. The aim of this prospective study is to compare the radiographic methods of measuring palmar angulation with the ultrasound method. PATIENTS/MATERIAL AND METHOD: 20 patients with a neck fracture of the metacarpals IV or V were treated either conservatively or operatively. 2 weeks after trauma or operation, an x-ray was performed. 2 examiners measured the palmar angulation on the oblique and lateral projections using 2 different methods (medullary canal and dorsal cortex methods). At the same time, the 2 examiners performed measurements of palmar angulation using ultrasound. The measurements obtained with the different methods as well as by the 2 examiners at 2 different terms were compared. Intra- and interobserver reliability of each method was calculated, and for the ultrasound method a test for accuracy of the measured angles was performed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Apart from one article published by Rabl and Sigrist in 1992 (Rechtsmedizin 2:156-158), there are no further reports on secondary skull fractures in shots from captive bolt guns. Up to now, the pertinent literature places particular emphasis on the absence of indirect lesions away from the impact point, when dealing with the wounding capacity of slaughterer's guns. The recent observation of two suicidal head injuries accompanied by skull fractures far away from the bolt's path gave occasion to experimental studies using simulants (glycerin soap, balls from gelatin) and skull brain models. As far as ballistic soap was concerned, the dimensions of the bolt's channel were assessed by multi-slice computed tomography before cutting the blocks open. The test shots to gelatin balls and to skull-brain models were documented by means of a high-speed motion camera. As expected, the typical temporary cavity effect of bullets fired from conventional guns could not be observed when captive bolt stunners were discharged. Nevertheless, the visualized transfer of kinetic energy justifies the assumption that the secondary fractures seen in thin parts of the skull were caused by a hydraulic burst effect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES:: Metacarpal juxta-articular bone is altered in Rheumatoid Arthritis (RA). However, a detailed analysis of disease related geometrical adaptations of the metacarpal shaft is missing. The aim of the present study was to assess the role of RA disease, forearm muscle cross-sectional area (CSA), age and sex on bone geometry at the metacarpal shaft. METHODS:: In 64 RA patients and 128 control subjects geometric properties of the third metacarpal bone mid-shaft and forearm muscle CSA were measured by peripheral quantitative computed tomography (pQCT). Linear models were performed for cortical CSA, total bone CSA, polar stress-strain Index (polar SSI, a surrogate for bone's resistance to bending and torsion), cortical thickness and Metacarpal Index (MI=cortical CSA/total CSA) with explanatory variables muscle CSA, age, RA status and sex. RESULTS:: Forearm muscle CSA was associated with cortical and total metacarpal CSA, and polar SSI. RA group status was associated with all bone parameters except cortical CSA. There was a significant interaction between RA status and age, indicating that the RA group had a greater age-related decrease in cortical CSA, cortical thickness and MI. CONCLUSIONS:: Bone geometry of the metacarpal shaft is altered in RA patients compared to healthy controls. While bone mass of the metacarpal shaft is adapted to forearm muscle mass, cortical thickness and MI are reduced but outer bone shaft circumference and polar SSI increased in RA patients. These adaptations correspond to an enhanced aging pattern in RA patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the clinical efficacy of endovascular therapy of symptomatic obstructions of the common femoral artery (CFA).