825 resultados para Fault Tolerance
Resumo:
YBaCuO-coated conductors offer great potential in terms of performance and cost-saving for superconducting fault current limiter (SFCL). A resistive SFCL based on coated conductors can be made from several tapes connected in parallel or in series. Ideally, the current and voltage are shared uniformly by the tapes when quench occurs. However, due to the non-uniformity of property of the tapes and the relative positions of the tapes, the currents and the voltages of the tapes are different. In this paper, a numerical model is developed to investigate the current and voltage sharing problem for the resistive SFCL. This model is able to simulate the dynamic response of YBCO tapes in normal and quench conditions. Firstly, four tapes with different Jc 's and n values in E-J power law are connected in parallel to carry the fault current. The model demonstrates how the currents are distributed among the four tapes. These four tapes are then connected in series to withstand the line voltage. In this case, the model investigates the voltage sharing between the tapes. Several factors that would affect the process of quenches are discussed including the field dependency of Jc, the magnetic coupling between the tapes and the relative positions of the tapes. © 2010 IEEE.
Resumo:
Salt tolerance of selected cultures of Pseudomonas, Moraxella, Vibrio, Micrococcus, Acinetobacter and Flavobacteria/ Cytophaga was determined. More than 80% of the cultures belonging to each of the above genera, were capable of growth in presence of 1.5 to 3.5% salt (NaCl) and at least 25 to 30% of the cultures in each group required 1.5 to 3.5% salt for growth. 40% each of Pseudomonas and Vibrio strains and 30% each of Moraxella, Micrococcus and Flavobacteria/Cytophaga strains tolerated 10% salt. Majority of the cultures belonging to the genera Pseudomonas, Vibrio, Moraxella, Micrococcus, Acinetobacter and Flavobacteria/Cytophaga were slightly halophilic (2 to 5% salt tolerant), about 25% especially of Micrococcus spp. moderately halophilic (5 to 20% salt tolerant) and none from Pseudomonas, Vibrio, Moraxella, Acinetobacter and Flavobacteria/Cytophaga spp. extremely halophilic (20 to 32% salt tolerant).
Resumo:
Copper is used to deter the growth of bacterial, fungal and protozoan disease organism in fishes. Zoeae (Z SUB-1 ), myses (M SUB-1 ) and postlarvae (P SUB-1 ) were exposed to copper sulfate at concentrations of 0 . 025, 0 . 05, 0 . 75, 0 . 1 and 0 . 2 ppm from 24 to 96 hours. The number of surviving larvae were counted at the end of each 24-hour period and the percentage of survival is determined for each dose level. The LC SUB-50 for each of the larval stages was interpolated from the data whenever possible. Three trials with 2 replicates per trial were conducted. The physico-chemical characteristics of the bath taken before and at the end of the experimental period show insignificant differences between initial and final values in each trial. Results indicate that mortality rates of all larval stages increased with exposure time and that mortality rates of the experimental group is higher than the control. Interpolation of the LC SUB-50 is possible only for the 48-h and 72-h exposure times for both zoeae and myses and for the 48-h exposure time for the postlarvae. This is due to the high survival percentage of the 24-h group and the low survival percentage (below 50%) of the larvae exposed for 96 hours. The 48-hour LC SUB-50 for Z SUB-1 , M SUB-1 and P SUB-1 are 0 . 225, 0 . 350 and 0 . 125 ppm respectively. Postlarvae seem to be more sensitive than either of the 2 larval stages having a lower 48-h LC SUB-50 and a low survival rate after 72 hours. The larvae were observed to lose their balance and were lethargic, producing few swimming movements so that they were mostly confined to the bottom of the aquaria. Moribund larvae observed under the microscope had a faster but weak heartbeat compared to healthy larvae. Slight or complete loss of feeding ability indicated by empty guts and delayed molting of Z SUB-1 to Z SUB-2 were also noted.
Resumo:
Four size groups of milkfish were tested, 4-18 g, 20-34 g, 35-95 g and 200-300 g. A number of fish from each group were placed separately in identical 1.2 m2 wooden tanks containing seawater filled up to 30 cm depth. The aggregate weight of fish per size group was approximately 1 kg. The fish were held for 72 h, fed with lab-lab and provided with continuous aeration to allow recovery from stress during transport and handling. After the recovery period, aeration was stopped and 200 g of the fine rice bran was spread over the water in each tank creating a film of bran particles on the water surface. This was designed to speed up depletion of dissolved oxygen considering the combined effects of the screening-off of sunlight, the reduction of air-water interface and the breakdown of the bran particles. It is probable that stress on milkfish in brackishwater ponds could start when oxygen level drops to about 1.4 ppm. A further decrease to 0.04 ppm could produce a total kill of all specimens above 4 grams with marketable size and bigger size fish dying first.
Resumo:
Investigating the activities of the prefrontal cortex (PFC) in the process of addiction is valuable for understanding the neural mechanism underlying the impairments of the PFC after drug abuse. However, limited data are obtained from primate animals and few studies analyze Electroencephalogram (EEG) in the gamma band, which plays an important role in cognitive functions. In addition, it is yet unclear whether drug abuse affects the orbitofrontal cortex (OFC) and dorsolateral PFC (DLPFC) - the two most important subregions of the PFC - in similar ways or not. The aim of this study is to address these issues. We recorded EEG in the OFC and DLPFC in three rhesus monkeys. All animals received a course of saline (NaCl 0.9%, 2 ml) injection (5 days) followed by 10 days of morphine injection (every 12 h), and then a further series of saline injection (7 days). A main finding in the present study was that morphine decreased EEG power in all frequency bands in a short period after injection in both the OFC and DLPFC in monkeys. And gamma power decreased not just in short period after morphine injection but lasted to 12 h after injection. Moreover, we found that although the changes in EEG activities in the OFC and DLPFC at 30-35 min after injection were similar, the DLPFC was more sensitive to the effect of morphine than the OFC. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
Nowadays, control systems are involved in nearly all aspects of our lives. They are all around us, but their presence is not always really apparent. They are in our kitchens, in our DVD-players, computers and our cars. They are found in elevators, ships, aircraft and spacecraft. Control systems are present in every industry, they are used to control chemical reactors, distillation columns, and nuclear power plants. They are constantly and inexhaustibly working, making our life more comfortable and more efficient...until the system fails. © 2010 Springer-Verlag Berlin Heidelberg.
Resumo:
We discuss solvability issues of H_-/H_2/infinity optimal fault detection problems in the most general setting. A solution approach is presented which successively reduces the initial problem to simpler ones. The last computational step generally may involve the solution of a non-standard H_-/H_2/infinity optimization problem for which we discuss possible solution approaches. Using an appropriate definition of the H- index, we provide a complete solution of this problem in the case of H2-norm. Furthermore, we discuss the solvability issues in the case of H-infinity-norm.
Resumo:
We discuss solvability issues of ℍ -/ℍ 2/∞ optimal fault detection problems in the most general setting. A solution approach is presented which successively reduces the initial problem to simpler ones. The last computational step generally may involve the solution of a non-standard ℍ -/ ℍ 2/∞ optimization problem for which we discuss possible solution approaches. Using an appropriate definition of the ℍ -- index, we provide a complete solution of this problem in the case of ℍ 2-norm. Furthermore, we discuss the solvability issues in the case of ℍ ∞-norm. © 2011 IEEE.
Resumo:
A superconducting fault current limiter (SFCL) for 6.6 kV and 400 A installed in a cubicle for a distribution network substation was conceptually designed. The SFCL consists of parallel- and series-connected superconducting YBCO elements and a limiting resistor. Before designing the SFCL, some tests were carried out. The width and length of each element used in the tests are 30 mm and 210 mm, respectively. The element consists of YBCO thin film of about 200 nm in thickness on cerium dioxide (CeO2) as a cap-layer on a sapphire substrate by metal-organic deposition with a protective metal coat. In the tests, characteristics of each element, such as over-current, withstand-voltage, and so on, were obtained. From these characteristics, series and parallel connections of the elements, called units, were considered. The characteristics of the units were obtained by tests. From the test results, a single phase prototype SFCL was manufactured and tested. Thus, an SFCL rated at 6.6 kV and 400 A can be designed. © 2009 IEEE.
Resumo:
Superconducting Fault Current Limiters (SFCLs) are able to reduce fault currents to an acceptable value, reducing potential mechanical and thermal damage to power system apparatus and allowing more flexibility in power system design and operation. The device can also help avoid replacing circuit breakers whose capacity has been exceeded. Due to limitations in current YBCO thin film manufacturing processes, it is not easy to obtain one large thin film that satisfies the specifications for high voltage and large current applications. The combination of standardized thin films has merit to reduce costs and maintain device quality, and it is necessary to connect these thin films in different series and parallel configurations in order to meet these specifications. In this paper, the design of a resistive type SFCL using parallel-connected YBCO thin films is discussed, including the role of a parallel resistor and the influence of individual thin film characteristics, based on both theory and experimental results. © 2009 IEEE.
Resumo:
This paper aims to solve the fault tolerant control problem of a wind turbine benchmark. A hierarchical controller with model predictive pre-compensators, a global model predictive controller and a supervisory controller is proposed. In the model predictive pre-compensator, an extended Kalman Filter is designed to estimate the system states and various fault parameters. Based on the estimation, a group of model predictive controllers are designed to compensate the fault effects for each component of the wind turbine. The global MPC is used to schedule the operation of the components and exploit potential system-level redundancies. Extensive simulations of various fault conditions show that the proposed controller has small transients when faults occur and uses smoother and smaller generator torque and pitch angle inputs than the default controller. This paper shows that MPC can be a good candidate for fault tolerant controllers, especially the one with an adaptive internal model combined with a parameter estimation and update mechanism, such as an extended Kalman Filter. © 2012 IFAC.