Lasers are widely used tools in many therapeutic modalities in medical lasers and can be divided into low and high intensity. For the treatment of periodontal disease, lowintensity lasers are related to reduce the number of bacteria and to induce inflammatory and analgesic properties. The high intensity lasers can be used in surgical procedures, improving hemostasis, promoting more accurate cuts, removal of dental calculus as well as thermomechanical and photochemical interactions with tissue. The high-intensity laser Erbium impregnated with chromium: YSGG laser has shown satisfactory results when applied in endodontic, restorative denstistry, surgical procedures and non-surgical periodontal treatment. The purpose of this review is to evaluate the studies that investigated the effects of Er, Cr: YSGG laser on the morphology and biocompatibility of titanium and root surfaces irradiated with these lasers, even beyond the effect on the treatment of periodontitis and periimplantitis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to evaluate the effect of Er:YAG (L) and diamond drills (DD) on: 1) the microshear bond strength (MPa); 2) the adhesive interface of two-step (TS) – Adper Scotchbond Multipurpose and one-step (OS) adhesives – Adper EasyOne, both from 3M ESPE. Material and methods: According to the preparation condition and adhesives, the samples were divided into four groups: DD_TS (control); DD_OS; L_TS and L_OS. 60 bovine incisors were randomly divided into experimental and groups: 40 for microshear bond strength (n = 10) and 20 for the adhesive interface morphology [6 to measure the thickness of the hybrid layer (HL) and length of tags (t) by CLSM (n = 3); 12 to the adhesive interface morphology by SEM (n = 3) and 2 to illustrate the effect of the instruments on dentine by SEM (n = 1)]. To conduct the microshear bond strength test, four cylinders (0.7 mm in diameter and 1 mm in height with area of adhesion of 0.38 mm) were constructed with resin composite (Filtek Z350 XT – 3M ESPE) on each dentin surface treated by either L or DD and after adhesives application. Microshear bond strength was performed in universal testing machine (EMIC 2000) with load cell of 500 kgf and a crosshead speed of 0.5 mm / min. Adhesive interface was characterized by thickness of hybrid layer (HL) and length of tags (t) in nm, with the aid of UTHSCSA ImageTool software. Results: Microshear bond strength values were: L_TS 34.10 ± 19.07, DD_TS 24.26 ± 9.35, L_OS 33.18 ± 12.46, DD_OS 21.24 ± 13.96. Two-way ANOVA resulted in statistically significant differences only for instruments (p = 0.047). Mann-Whitney identified the instruments which determined significant differences for HL thickness and tag length (t). Concerning to the adhesive types, these differences were only observed for (t). Conclusion: It can be concluded that 1) laser Er:YAG results in higher microshear bond strength values regardless of the adhesive system (TS and OS); 2) the tags did not significant affect the microshear bond strength; 3) the adhesive interface was affected by both the instruments for cavity preparation and the type of adhesive system used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ideally projected to be applied on soft tissues, infrared lasers were improved by restorative dentistry to be used in hard dental tissues cavity preparations-namely enamel and dentin. This paper evidentiates the relevant aspects of infrared Erbium laser's action mechanism and its effects, and characterizes the different effects deriving from the laser's beams emission. The criteria for use and selection of optimal parameters for the correct application of laser systems and infuence of supporting factors on the process, such as water amount and its presence in the ablation process, protection exerted by the plasma shielding and structural factors, which are indispensable in dental tissues cavity preparation related to restorative technique, are subordinated to optical modifcations caused by the interaction of the energy dissipated by these laser light emission systems in the targeted tissue substrate. Clinical relevance: Differences in the action of infrared Erbium laser system in regard to the nature of the ablation process and variations on the morphological aspects observed in the super-fcial structure of the target tissue irradiated, may be correlated to the structural optical modifcations of the substrate produced by an interaction of the energy propagated by laser systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The laser has been widely used in many specialties of dentistry and several wavelengths have been investigated as a substitute for high-speed handpiece. The purpose of this paper is to review the literature about the use of Er:YAG and Er,Cr:YSGG lasers in cavity preparation for dental tissues. Despite the differences in wavelength, pulse duration and energy, the morphological characteristics of the irradiated dentin surface with these lasers are comparable, as well as its effects as methods of dental caries prevention. Thus, Er:YAG and Er,Cr:YSGG lasers prepared cavities with similar effects on the dental tissue, however, further investigations about ideal irradiation conditions are needed for both lasers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the effect of Er,Cr:YSGG laser irradiation on the external adaptation of composite resin restorations in caries-affected cavities. Mixed class V cavity preparations were performed in 36 intact human third molars, in half of which caries was artificially induced. Both healthy and carious dentin were etched with 35% phosphoric acid (Ultradent Products Inc., South Jordan, Utah, USA), and the teeth were divided into three groups, i.e., (a) untreated etched dentin, (b) application of the Er, Cr:YSGG laser and (c) use of chlorhexidine as an adjunct in the bonding process. Restorations were fabricated with Z350 XT FiltekTM composite resin (3M ESPE) and subsequently the specimens were subjected to thermocycling to simulate artificial ageing. Quantitative analysis of external adaptation was performed by scanning electron microscopy in both healthy and affected dentin using epoxy resin replicas. It was concluded that the application of laser and chlorhexidine did not affect the percentages of marginal adaptation of class V restorations. Furthermore, thermocycling may influence adaptation values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effects of different power parameters of an Erbium, Cromium: Yttrium, Scandium, Gallium, Garnet laser (Er,Cr:YSGG laser) on the morphology, attachment of blood components (ABC), roughness, and wear on irradiated root surfaces. Sixty-five incisive bovine teeth were used in this study, 35 of which were used for the analysis of root surface morphology and ABC. The remaining 30 teeth were used for roughness and root wear analysis. The samples were randomly allocated into seven groups: G1: Er,Cr:YSGG laser, 0.5 W; G2: Er,Cr:YSGG laser, 1.0 W; G3: Er,Cr:YSGG laser, 1.5 W; G4: Er,Cr:YSGG laser, 2.0 W; G5: Er,Cr:YSGG laser, 2.5 W; G6: Er,Cr:YSGG laser, 3.0 W; G7: scaling and root planning (SRP) with manual curettes. The root surfaces irradiated by Er,Cr:YSGG at 1.0 W and scaling with manual curettes presented the highest degrees of ABC. The samples irradiated by the Er,Cr:YSGG laser were rougher than the samples treated by the manual curette, and increasing the laser power parameters caused more root wear and greater roughness on the root surface. The Er,Cr:YSGG laser is safe to use for periodontal treatment, but it is not appropriate to use irradiation greater than 1.0 W for this purpose. Microsc. Res. Tech. 78:529–535, 2015. © 2015 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the influence of the surface pretreatment of indirect resin composite (Signum, Admira Lab and Sinfony) on the microtensile bond strength of a resin cement. Sixty samples made of each brand were divided into 6 groups, according to surface treatment: (1) control; (2) controlled-air abrasion with Al2O3; (3) Er:YAG Laser 200 mJ, 10 Hz, for 10s; (4) Er: YAG Laser 300 mJ, 10 Hz, for 10 s; (5) Nd:YAG 80 mJ, S15Hz for 1 min; (6) Nd:YAG 120mJ, 15 Hz for 1 min. After treatments, all the groups received an application of 37% phosphoric acid and adhesive. The pair of blocks of the same brand were cemented to each other with dual resin cement. The blocks were sectioned to obtain resin-resin sticks (1 x1 mm) and analyzed by microtensile bond testing. The bond strength values were statistically different, irrespective of the surface treatment performed, with highest values for Sinfony (43.81 MPa) and lowest values for Signum (32.33 MPA). The groups treated with the Nd:YAG laser showed the lowest bond strength values and power did not interfere in the results, both for Nd:YAG laser and Er:YAG. Controlled-air abrasion with Al203 is an efficient surface treatment method and the use of the Nd:YAG and Er:YAG lasers reduced bond strength, irrespective of the intensity of energy used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to investigate the effects of Er:YAG and Nd:YAG lasers on the shear bond strength of composite resin to dentin. The coronal portion of 56 human molars was divided into three parts, and the dentin thickness was standardized at 2 mm. A 3-mm hole was marked in the center of each tooth with sealing tape paper. The specimens (n = 14) were then divided into four groups: (1) acid etching + Single Bond (SB) (control), (2) acid etching + SB + Nd:YAG laser irradiation (before adhesive curing), (3) thermal etching with the Er:YAG laser + SB, and (4) thermal etching with the Er:YAG laser + SB + Nd:YAG laser irradiation (before adhesive curing). A composite resin cylinder was built into the delimited area for conducting the shear bond strength test on the universal testing machine. The means ± standard deviations were: group 1, 17.05 ± 4.15 MPa; group 2, 16.90 ± 3.36 MPa; group 3, 12.12 ± 3.85 MPa; and group 4, 12.92 ± 2.73 MPa. Groups 1 and 2 presented significantly higher values than groups 3 and 4. It was concluded that conventional etching with 37% phosphoric acid yielded significantly higher bond strength values compared to thermal etching with the Er:YAG laser. The Nd:YAG laser did not significantly influence the bond strength.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Prostate physiology is highly dependent on oestrogenic and androgenic homeostasis. Interferences in this equilibrium, especially in early periods of life, may disrupt the prostate and increase the susceptibility to the development of diseases with ageing. Taking this into account, and considering the increase of environmental chemicals with endocrine-disrupting potential such as bisphenol-A (BPA), this study aimed to evaluate the prostates of adult female gerbils exposed to BPA and BPA plus testosterone from pubertal to adult periods. Morphological, stereological and chemical analyses revealed that long-term BPA exposure, even in environmental dosages, increases the proliferative status of the prostate, increases the number of ERα-positive stromal cells and elicits the development of prostatic hyperplasia in adult female gerbils. Moreover, we also observed that the association with testosterone did not increase the proliferative status of the gland, which shows that low levels of BPA are enough to cause an oestrogenic disruption of the prostate in young adults. This evidence suggests that this oestrogenic endocrine disruptor may increase the susceptibility to prostatic disorders with ageing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to compare temperature increases produced by a well-known equipment, the high-speed handpieces, with a relatively new instrument, the Er:YAG laser (350 mJ/10 Hz). Thirty-five bovine mandibular incisors, which were reduced to an enamel/dentin thickness of 2,5 mm, were used. Cavity preparation was done till a depth of 2, 5 mm. A thermocouple was placed to read the temperature inside of the pulp chamber. Analysis was performed in these groups: I - high-speed handpiece without water-cooling (n=10); II - high-speed handpiece with water-cooling (n=10); III - Er:YAG laser without water-cooling (n=5); IV- Er:YAG laser with water-cooling (n=10) Group III had only 5 teeth because it was impossible to properly make the cavity preparations by the laser equipment without water cooling. The temperature increases were recorded in a computer linked to the thermocouples and the data of the groups I, II and IV were submitted to Dunn's multiple comparison test (p<0,05). The medium temperature increases were: 11,64ºC for group I, 0,96ºC for group II, 40,86ºC for group III and 2,9°C for group IV. There were no statistical differences between groups lI and IV, and these were different from group I. The cavity preparations made by the high-speed and the laser equipment generated very similar heat increases under water-cooling. The water-cooling is essential to avoid aggressive temperature increases, both when using the high-speed and the laser equipment, and with laser it is especially necessary for ablation of enamel

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Odontologia Restauradora - ICT

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A polymeric precursor solution was used to deposit pure and Mg doped LiNbO3 thin films on sapphire substrates by spin-coating. The effects of magnesium addition on crystallinity, morphology and optical properties of the annealed films were investigated. X-ray diffraction patterns indicate the oriented growth of the films. Phi-scan diffraction evidenced the epitaxial growth with two in-plane variants. AFM studies show that the films are very homogeneous, dense and present smooth surfaces. The refractive index and optical losses obtained by the prism coupling method were influenced by the magnesium addition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The objective of this study was to evaluate the effect of Er: YAG laser on the formation of CaF2, after the application of acidulated phosphate fluoride (APF), and its influence on the anti-cariogenic action in human dental enamel. Background Data: Er:YAG laser was designed to promote ablation of the enamel. However, the possibility of using this energy to increase the enamel's resistance to caries has hardly been explored, and neither has its interaction with the use of fluorides. Materials and Methods: One hundred and twenty blocks of enamel were allocated to four groups of 30 blocks each: (1) C, control group; (2) Er:YAG, laser; (3) APF; and (4) Er:YAG+APF. Of these, 80 blocks were submitted to pH cycling for 14 days. In the other 40 blocks, fluoride (CaF2) was measured before cycling. After pH cycling, surface microhardness (SMH), microhardness in cross-section (converted to mineral contents % vol. min.), and fluoride after cycling (40 blocks) were also determined. Results: SMH decreased in all groups. The control group showed the highest decrease, and Er:YAG+APF showed the lowest decrease (p < 0.05). Groups APF and Er:YAG showed the same results (p > 0.05). Mineral content at depths 10, 20, and 40 μm was lower in the control and Er:YAG groups, and higher in groups APF and Er:YAG+APF. CaF2 (μgF/cm2) deposited before pH cycling was higher in the APF group when compared to the Er:YAG+APF group. Control and Er:YAG groups showed the lowest values (p > 0.05). Conclusion: It was concluded that Er:YAG laser influenced the deposition of CaF2 on the enamel and showed a superficial anti-cariogenic action, but not in depth.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The use of Er:YAG laser operating in the 3 μm range with adjustable power and pulses has become popular for dental and medical practice due to its high photoablative capacity, surgical precision and antimicrobial action. Background data: The existing fiberoptic tips irradiate lasers parallel to the long axes of the tooth limiting its efficiency in the root canal. Methods: We evaluated hollow fiberoptic tips obtained from silicate glass as a means of Er:YAG laser conduction in dental procedures. The fiber tips were molded from capillary tubes with different profiles so that their ends would have cylindric, conical or spherical shapes. The performance of the three fibers as a means of propagation of Er:YAG (λ = 2.94 μm) laser radiation was compared to that of a solid sapphire fiber at 10 Hz and 200 mJ and of 20 Hz and 500 mJ. The profiles of frontal and lateral burning were visualized on thermal paper. Results: Analysis of these profiles demonstrated that the sapphire tip and the hollow fiber of cylindric section did not differ significantly in the profiles of frontal burning, and no lateral burning was detected. The fibers of the conical and spherical sections, although presenting attenuation in the frontal output power, showed a larger burning area in the frontal profile, in addition to producing lateral burning. Conclusions: The results indicate that commercial hollow fiberoptics have advantages such as easy manufacture of the different tip shapes, great adaptability, low cost, and a low loss of transmission. © Mary Ann Liebert, Inc.